Displaying publications 21 - 40 of 76 in total

Abstract:
Sort:
  1. Ismail B, Redzuwan Y, Chua RS, Shafiee W
    Appl Radiat Isot, 2001 Mar;54(3):393-7.
    PMID: 11214872
    The processing of amang (one of a number of tin-tailing products) for its valuable minerals has associated with the radiological and environmental problems. The processing and stockpiling of amang and ilmenite in open-air spaces, subject as it is to environmental influences, gives rise to a potential for affecting residents in adjacent area. A case study was carried out in a residential area neighbouring a typical amang plant to investigate the radiological impact to the residents. The average Effective Dose rates, calculated based on the contributions of Effective Dose rates from inhaled suspended radioactive dust, radon-thoron and their progeny, and external gamma radiation, were determined for selected houses. Results show that the occupants of those houses received Effective Dose rate, which cannot be differentiated from background. The major contributor to the average Effective Dose rate came from external radiation sources. Inhaled radon and its progeny was the second major contributor.
    Matched MeSH terms: Air Pollution, Indoor/adverse effects; Air Pollution, Indoor/analysis
  2. Khamal R, Isa ZM, Sutan R, Noraini NMR, Ghazi HF
    Ann Glob Health, 2019 01 22;85(1).
    PMID: 30741516 DOI: 10.5334/aogh.2425
    INTRODUCTION: Indoor air quality in day care centers (DCCs) is an emerging research topic nowadays. Indoor air pollutants such as particulate matter (PM) and microbes have been linked to respiratory health effects in children, particularly asthma-related symptoms such as night coughs and wheezing due to early exposure to indoor air contaminants.

    OBJECTIVE: The aim of this study was to determine the association between wheezing symptoms among toddlers attending DCCs and indoor particulate matter, PM10, PM2.5, and microbial count level in urban DCCs in the District of Seremban, Malaysia.

    METHODS: Data collection was carried out at 10 DCCs located in the urban area of Seremban. Modified validated questionnaires were distributed to parents to obtain their children's health symptoms. The parameters measured were indoor PM2.5, PM10, carbon monoxide, total bacteria count, total fungus count, temperature, air velocity, and relative humidity using the National Institute for Occupational Safety and Health analytical method.

    RESULTS: All 10 DCCs investigated had at least one indoor air quality parameter exceeding the acceptable level of standard guidelines. The prevalence of toddlers having wheezing symptoms was 18.9%. There was a significant different in mean concentration of PM2.5 and total bacteria count between those with and those without wheezing symptoms (P = 0.02, P = 0.006).

    CONCLUSIONS: Urban DCCs are exposed to many air pollutants that may enter their buildings from various adjacent sources. The particle concentrations and presence of microbes in DCCs might increase the risk of exposed children for respiratory diseases, particularly asthma, in their later life.

    Matched MeSH terms: Air Pollution, Indoor/analysis; Air Pollution, Indoor/prevention & control
  3. Lim FL, Hashim Z, Md Said S, Than LT, Hashim JH, Norbäck D
    Sci Total Environ, 2015 Dec 1;536:353-61.
    PMID: 26225741 DOI: 10.1016/j.scitotenv.2015.06.137
    There are few studies on sick building syndrome (SBS) including clinical measurements for atopy and fractional exhaled nitric oxide (FeNO). Our aim was to study associations between SBS symptoms, selected personal factors, office characteristics and indoor office exposures among office workers from a university in Malaysia. Health data were collected by a questionnaire (n=695), skin prick test (SPT) (n=463) and FeNO test (n=460). Office settled dust was vacuumed and analyzed for endotoxin, (1,3)-β-glucan and house dust mites (HDM) allergens group 1 namely Dermatophagoides pteronyssinus (Der p 1) and Dermatophagoides farinae (Der f 1). Office indoor temperature, relative air humidity (RH), carbon monoxide (CO) and carbon dioxide (CO2) were measured by a direct reading instrument. Associations were studied by two-levels multiple logistic regression with mutual adjustment and stratified analysis. The prevalence of weekly dermal, mucosal and general symptoms was 11.9%, 16.0% and 23.0% respectively. A combination of SPT positivity (allergy to HDM or cat) and high FeNO level (≥25 ppb) was associated with dermal (p=0.002), mucosal (p<0.001) and general symptoms (p=0.05). Der f1 level in dust was associated with dermal (p<0.001), mucosal (p<0.001) and general (p=0.02) symptoms. Among those with allergy to D. farinae, associations were found between Der f 1 levels in dust and dermal (p=0.003), mucosal (p=0.001) and general symptoms (p=0.007). Office-related symptoms were associated with Der f 1 levels in dust (p=0.02), low relative air humidity (p=0.04) and high office temperature (p=0.05). In conclusion, a combination of allergy to cat or HDM and high FeNO is a risk factor for SBS symptoms. Der f 1 allergen in dust can be a risk factor for SBS in the office environment, particularly among those sensitized to Der f 1 allergen.
    Matched MeSH terms: Air Pollution, Indoor/analysis*; Air Pollution, Indoor/statistics & numerical data
  4. Sasnila Pakpahan, Bambang Wispriyono, Budi Hartono, Juliana Jalaludin
    MyJurnal
    Introduction: School environment represents an important microenvironment for students who spend 6-8 hours in classrooms. Indoor air quality is linked to several respiratory diseases in the school age group. This research aims to study indoor air quality of schools at different environmental characteristic and assess its health risks to students. Methods: This research measured air quality (PM2.5, PM10, CO2 , and HCHO) in three junior high schools and followed by health risk assessment. Results: This research found that the mean or median level of indoor PM2.5 and PM10 in all three schools exceeded the standard value with health risks (HQ> 1) for PM2.5 in all three schools and PM10 in two schools. Whereas carbon dioxide and formaldehyde concentrations were still safe and did not inflict health risks (HQ < 1). The scenario for managing the health risk of PM2.5 and PM10 exposure was to control the exposure at a safe threshold of PM2.5 0.035 mg/m3 ; 0.043 mg/m3 and PM10 0.144 mg/m3 for most of the population at normal school time. Conclusion: It was concluded that the level of indoor particulate matters indicates poor indoor air quality in all three schools at different environmental characteristic and inflicts health risk on students so that the health risk management is required.
    Matched MeSH terms: Air Pollution, Indoor
  5. Al-Shamiry, Faisal Mohammed Seif, Desa Ahmad
    MyJurnal
    Natural ventilation is defined as the number of air exchanges per hour per unit floor area necessary
    to reduce high indoor air temperature and humidity. In addition, it maintains the concentration of carbon dioxide. Natural ventilation is preferred in mechanical system as the ventilation opening is built into the greenhouse, with lower construction cost and no energy and maintenance inputs are required. A mathematical model to quantify natural ventilation rates was developed and verified in large-scale greenhouse structures. For this purpose, four Naturally Ventilated Tropical Greenhouse Structures were designed and constructed at the Malaysian Agricultural Research and Development Institute (MARDI). These were single, double, triple, and quadruple span structures with floor areas of 500 m2, 1000 m2, 1500 m2 and 2000 m2, respectively. This paper presents the validation of a mathematical model which was developed to quantify natural ventilation rates which are very crucial to reduce high in-house temperature built up in the tropics. Regression equations of natural ventilation against wind speed were found to be Φw = 0.0632V, Φw= 0.0395V, Φw= 0.0316Vand Φw=0.0276V for the single, double, triple and quadruple spans, respectively. Meanwhile, coefficients of determination showed strong relationships between ventilation rate and wind speed, with R2 = 0.9999 for all structures. Larger floor area was found to have higher in-house temperature than smaller ones. Ventilation rate inside the single-span structure was found to be higher compared to the multi-span structures, which increased linearly with the increasing wind speed at the eaves of structure.
    Matched MeSH terms: Air Pollution, Indoor
  6. Salamone F, Belussi L, Danza L, Galanos T, Ghellere M, Meroni I
    Sensors (Basel), 2017 May 04;17(5).
    PMID: 28471398 DOI: 10.3390/s17051021
    The article describes the results of the project "open source smart lamp" aimed at designing and developing a smart object able to manage and control the indoor environmental quality (IEQ) of the built environment. A first version of this smart object, built following a do-it-yourself (DIY) approach using a microcontroller, an integrated temperature and relative humidity sensor, and techniques of additive manufacturing, allows the adjustment of the indoor thermal comfort quality (ICQ), by interacting directly with the air conditioner. As is well known, the IEQ is a holistic concept including indoor air quality (IAQ), indoor lighting quality (ILQ) and acoustic comfort, besides thermal comfort. The upgrade of the smart lamp bridges the gap of the first version of the device providing the possibility of interaction with the air exchange unit and lighting system in order to get an overview of the potential of a nearable device in the management of the IEQ. The upgraded version was tested in a real office equipped with mechanical ventilation and an air conditioning system. This office was occupied by four workers. The experiment is compared with a baseline scenario and the results show how the application of the nearable device effectively optimizes both IAQ and ILQ.
    Matched MeSH terms: Air Pollution, Indoor
  7. Ambu, Stephen, Chu, Wan-Loy, Mak, Joon-Wah, Wong, Shew-Fung, Chan, Li-Li, Wong, Siew-Tung
    MyJurnal
    Malaysia has good environmental laws to protect the outdoor environment and public health. However there are no laws governing indoor air quality (IAQ) and the knowledge among the public about its importance is also lacking. Environmental professionals think it is not a priority and this influences the policy decisions in the country. Therefore there is a need to create awareness by way of research, education and other promotional activities. What is much needed at this time is the establishment of standards for the conduct of risk assessment studies. To establish standards we need reliable data which can be used to develop appropriate guidelines for the purpose of mitigation and adaptation programmes. IAQ can have significant influence on health resulting in drop in productivity and economy of a country. It has been estimated that in the US, building related illnesses (BRI) symptoms have a relationship with decrease (3 to 5%) in work performance in an affected population resulting in an annual loss of US$60 billion in revenue. However, based on efficient management programmes they have also projected that the potential annual savings can be in the region of US$10 to 30 billion. This establishes that fact that good management programmes based on efficient guidelines is of economic value to a country and wellbeing of the population. The IMU has embarked on a research programme to collect the much-needed data for the framing of a good IAQ guideline for Malaysia.
    Matched MeSH terms: Air Pollution, Indoor
  8. Masitah Alias, Zaini Hamzah
    MyJurnal
    The growing concern over the workers safety and health has lead many factories and organizations do the air monitoring to ensure the airborne at their workplace is safe for the worker’s health and complying the Occupational Safety and Health Act 1994 (Act 514). In this study, the monitoring covers an indoor air quality and chemical exposure to the workers in one of the power plant repair shop. A few workers from different sections namely blasting, welding, grinding, fitting and maintenance area were chosen to assist in the personal monitoring for 8 hours measurement. PM10 were measured at a few sampling points to collect dusts for 24 hours duration. The samples were brought back to the laboratory for gravimetric and SEM-EDAX analysis. The results were certainly exceed the limit for air quality, and many elements were detected such as Fe, Ni, Al, Si, Ca, K, Ba, S, Cr, Zn and Cl. The present of these elements shows that exposure to these particulate matters is quite risky and some measure needs to be taken for remedial action.
    Matched MeSH terms: Air Pollution, Indoor
  9. Nor Mohd Razif Noraini, Leman, A.M., Ahmad Sayuti Zainal Abidin
    MyJurnal
    A preliminary study has been conducted in a new constructed 8 stories building (2 level of Hostels facility, 3 level of Training Room, 2 Level of Offices and 1 level of Exhibition Halls and Rooms) in Bandar Baru Bangi, Selangor. The Hostels facility is a floor tile and furnished with build in locker and use split air conditioning system while the Training Room and Exhibition Rooms used floor tile. The Offices and Exhibition Hall are carpeted furnished. All these spaces were using centralized air conditioning systems. A pre-commissioning assessment on 5 chemical parameters of indoor air pollutants such Total Volatile Organic Compounds (TVOC), Formaldehyde, Respirable Particulates (PM!
    Matched MeSH terms: Air Pollution, Indoor
  10. Shoffian Amin Jaafar, Suhaily Amran, Mohd Norhafsham Maghpor, Ahmad Sayuti Zainal, Nurzuhairah Jamil, Naemah Tajul Arus, et al.
    MyJurnal
    Indoor air quality is a term which refers to the air quality in and around buildings and structures, in which it
    is related to the health and comfort of those who are in the building. The study aims to identify the relationship
    between environmental factors with microbe growth by investigating the concentration of airborne bacteria and
    fungi at National Institute of Occupational Safety and Health (NIOSH) and to determine whether indoor bacteria and
    fungi concentration were associated with environmental factors such as temperature relative humidity and carbon
    dioxide concentration. This research was conducted concurrently with indoor air quality sampling as per requirement
    under the Malaysian Code of Practice of Indoor Air Quality (COP IAQ). The COP IAQ requires minimum of one
    sample to be taken from each area. If an area consists of a few separated rooms, each room is sampled and measured
    independently. Also this approach was used to determine whether there is a difference of indoor bacteria and fungi
    in different microenvironments. Results show that there is a significant correlation between humidity and bacteria
    concentration and fungi concentration; and between temperature and bacteria concentration. However, there is no
    significant correlation between temperature and fungi concentration. This study has also established significant
    difference on bacteria concentration and fungi concentration between microenvironments.
    Matched MeSH terms: Air Pollution, Indoor
  11. Mohd Mahathir Suhaimi Shamsuri, Leman, A.M.
    MyJurnal
    Indoor pollution increasingly becomes a public concern. These concerns are related to energy efficiency in a
    building. There are various ways in which it can ensure energy conservation can be achieved, including superinsulation
    and reduced fresh air exchange. As a result, indoor air becomes stagnant and odours, thereafter contaminants of air will
    accumulate and will certainly disrupt human health. It is quite difficult to make people comfortable in a building with
    consumption of energy-saving and human health guaranteed. Indoor plants are one of the alternative solutions that
    have been studied since the last three decades. This paper intends to review the abilities of indoor plants to purify air,
    and the ways used by previous researchers to prove that indoor plants can treat the air. In general, it can be stated that
    indoor plants are able to absorb various types of volatile organic compounds (VOCs). An advantage of indoor plants
    to cure air from carcinogen gas is greatly needed for human health. Therefore, studies on indoor plants to neutralize
    the air are gaining attention. Enclosed space or chamber is often used by researchers to test the ability of indoor plants
    absorb gaseous toxins in their study; because it is easy to handle and can quickly determine the absorption rate. In the
    other hand, environmental factors such as temperature, humidity, and light are important to be taken into consideration
    during the study. As a conclusion, it can be stated that the existence of indoor plants in a building is very reasonable,
    because it can give positive impacts on human health and the total energy consumption.
    Matched MeSH terms: Air Pollution, Indoor
  12. Abdullah S, Abd Hamid FF, Ismail M, Ahmed AN, Wan Mansor WN
    Data Brief, 2019 Aug;25:103969.
    PMID: 31198825 DOI: 10.1016/j.dib.2019.103969
    The aim of the measurement of this data is to evaluate the Indoor Air Quality (IAQ) in terms of chemical and physical parameters. Data were collected at three different kindergartens having different surrounding activities (industrial, institutional, residential area). The chemical parameters measured were respirable suspended particulates of PM10, PM2.5, PM1, carbon monoxide and carbon dioxide, and the concentrations are within the acceptable limit. Physical parameters of wind speed are within the standard, while temperature and relative humidity exceeded the acceptable limit. A strong correlation was found between the chemical IAQ parameters with thermal comfort parameters (temperature and relative humidity). The concentration of IAQ pollutants is higher in order of residential > institutional > industrial.
    Matched MeSH terms: Air Pollution, Indoor
  13. Mohamad N, Latif MT, Khan MF
    Ecotoxicol Environ Saf, 2016 Feb;124:351-362.
    PMID: 26590697 DOI: 10.1016/j.ecoenv.2015.11.002
    This study aimed to investigate the chemical composition and potential sources of PM10 as well as assess the potential health hazards it posed to school children. PM10 samples were taken from classrooms at a school in Kuala Lumpur's city centre (S1) and one in the suburban city of Putrajaya (S2) over a period of eight hours using a low volume sampler (LVS). The composition of the major ions and trace metals in PM10 were then analysed using ion chromatography (IC) and inductively coupled plasma-mass spectrometry (ICP-MS), respectively. The results showed that the average PM10 concentration inside the classroom at the city centre school (82µg/m(3)) was higher than that from the suburban school (77µg/m(3)). Principal component analysis-absolute principal component scores (PCA-APCS) revealed that road dust was the major source of indoor PM10 at both school in the city centre (36%) and the suburban location (55%). The total hazard quotient (HQ) calculated, based on the formula suggested by the United States Environmental Protection Agency (USEPA), was found to be slightly higher than the acceptable level of 1, indicating that inhalation exposure to particle-bound non-carcinogenic metals of PM10, particularly Cr exposure by children and adults occupying the school environment, was far from negligible.
    Matched MeSH terms: Air Pollution, Indoor/analysis*
  14. Awang N, Jamaluddin F
    J Environ Public Health, 2014;2014:408275.
    PMID: 25136371 DOI: 10.1155/2014/408275
    This study was carried out to determine the concentration of lead (Pb), anions, and cations at six primary schools located around Kuala Lumpur. Low volume sampler (MiniVol PM10) was used to collect the suspended particulates in indoor and outdoor air. Results showed that the concentration of Pb in indoor air was in the range of 5.18 ± 1.08 μg/g-7.01 ± 0.08 μg/g. All the concentrations of Pb in indoor air were higher than in outdoor air at all sampling stations. The concentrations of cations and anions were higher in outdoor air than in indoor air. The concentration of Ca(2+) (39.51 ± 5.01 mg/g-65.13 ± 9.42 mg/g) was the highest because the cation existed naturally in soil dusts, while the concentrations of NO3 (-) and SO4 (2-) were higher in outdoor air because there were more sources of exposure for anions in outdoor air, such as highly congested traffic and motor vehicles emissions. In comparison, the concentration of NO3 (-) (29.72 ± 0.31 μg/g-32.00 ± 0.75 μg/g) was slightly higher than SO4 (2-). The concentrations of most of the parameters in this study, such as Mg(2+), Ca(2+), NO3 (-), SO4 (2-), and Pb(2+), were higher in outdoor air than in indoor air at all sampling stations.
    Matched MeSH terms: Air Pollution, Indoor/analysis*
  15. Jie Y, Ismail NH, Jie X, Isa ZM
    J Formos Med Assoc, 2011 Sep;110(9):555-63.
    PMID: 21930065 DOI: 10.1016/j.jfma.2011.07.003
    This review summarizes the results of epidemiological studies focusing on the detrimental effects of home environmental factors on asthma morbidity in adults. We reviewed the literature on indoor air quality (IAQ), physical and sociodemographic factors, and asthma morbidity in homes, and identified commonly reported asthma, allergic, and respiratory symptoms involving the home environment. Reported IAQ and asthma morbidity data strongly indicated positive associations between indoor air pollution and adverse health effects in most studies. Indoor factors most consistently associated with asthma and asthma-related symptoms in adults included fuel combustion, mold growth, and environmental tobacco smoke. Environmental exposure may increase an adult's risk of developing asthma and also may increase the risk of asthma exacerbations. Evaluation of present IAQ levels, exposure characteristics, and the role of exposure to these factors in relation to asthma morbidity is important for improving our understanding, identifying the burden, and for developing and implementing interventions aimed at reducing asthma morbidity.
    Matched MeSH terms: Air Pollution, Indoor/adverse effects*
  16. Latif MT, Baharudin NH, Velayutham P, Awang N, Hamdan H, Mohamad R, et al.
    Environ Monit Assess, 2011 Oct;181(1-4):479-89.
    PMID: 21181256 DOI: 10.1007/s10661-010-1843-3
    The renovation of a building will certainly affect the quality of air in the vicinity of where associated activities were undertaken, this includes the quality of air inside the building. Indoor air pollutants such as particulate matter, heavy metals, and fine fibers are likely to be emitted during renovation work. This study was conducted to determine the concentration of heavy metals, asbestos and suspended particulates in the Biology Building, at the Universiti Kebangsaan, Malaysia (UKM). Renovation activities were carried out widely in the laboratories which were located in this building. A low-volume sampler was used to collect suspended particulate matter of a diameter size less than 10 μm (PM₁₀) and an air sampling pump, fitted with a cellulose ester membrane filter, were used for asbestos sampling. Dust was collected using a small brush and scope. The concentration of heavy metals was determined through the use of inductively coupled plasma-mass spectroscopy and the fibers were counted through a phase contrast microscope. The concentrations of PM₁₀ recorded in the building during renovation action (ranging from 166 to 542 μg m⁻³) were higher than the value set by the Department of Safety and Health for respirable dust (150 μg m⁻³). Additionally, they were higher than the value of PM₁₀ recorded in indoor environments from other studies. The composition of heavy metals in PM₁₀ and indoor dust were found to be dominated by Zn and results also showed that the concentration of heavy metals in indoor dust and PM₁₀ in this study was higher than levels recorded in other similar studies. The asbestos concentration was 0.0038 ± 0.0011 fibers/cc. This was lower than the value set by the Malaysian Department of Occupational, Safety and Health (DOSH) regulations of 0.1 fibers/cc, but higher than the background value usually recorded in indoor environments. This study strongly suggests that renovation issues need to be considered seriously by relevant stakeholders within the university in order to ensure that the associated risks toward humans and indoor environment are eliminated, or where this is not feasible, minimized as far as possible.
    Matched MeSH terms: Air Pollution, Indoor/statistics & numerical data*
  17. Mirmohammadi M, Hakimi Ibrahim M, Ahmad A, Kadir MO, Mohammadyan M, Mirashrafi SB
    Environ Monit Assess, 2010 Jun;165(1-4):341-7.
    PMID: 19444630 DOI: 10.1007/s10661-009-0950-5
    Today, many raw materials used in factories may have a dangerous effect on the physiological system of workers. One of them which is widely used in the polyurethane factories is diisocyanates. These compounds are widely used in surface coatings, polyurethane foams, adhesives, resins, elastomers, binders, and sealants. Exposure to diisocyanates causes irritation to the skin, mucous membranes, eyes, and respiratory tract. Hexamethylene diamine (HDA) is metabolite of hexamethylene diisocyanate (HDI). It is an excretory material by worker's urine who is exposed to HDI. Around 100 air samples were collected from five defined factories by midget impinger which contained dimethyl sulfoxide absorbent as a solvent and tryptamine as reagent. Samples were analyzed by high-performance liquid chromatography with EC\UV detector using NIOSH 5522 method of sampling. Also, 50 urine samples collected from workers were also analyzed using William's biological analysis method. The concentration of HDI into all air samples were more than 88 microg/m(3), and they have shown high concentration of pollutant in the workplaces in comparison with NIOSH standard, and all of the workers' urine were contaminated by HDA. The correlation and regression test were used to obtain statistical model for HDI and HDA, which is useful for the prediction of diisocyanates pollution situation in the polyurethane factories.
    Matched MeSH terms: Air Pollution, Indoor*
  18. Edimansyah BA, Rusli BN, Naing L, Azwan BA, Aziah BD
    PMID: 19323052
    The purpose of this study was to determine the indoor air quality (IAQ) status of an automotive assembly plant in Rawang, Selangor, Malaysia using selected IAQ parameters, such as carbon dioxide (CO2), carbon monoxide (CO), temperature, relative humidity (RH) and respirable particulate matter (PM10). A cross-sectional study was conducted in the paint shop and body shop sections of the plant in March 2005. The Q-TRAK Plus IAQ Monitor was used to record the patterns of CO, CO2, RH and temperature; whilst PM10 was measured using DUSTTRAK Aerosol Monitor over an 8-hour time weight average (8-TWA). It was found that the average temperatures, RH and PM10 in the paint shop section and body shop sections exceeded the Department of Safety and Health (DOSH) standards. The average concentrations of RH and CO were slightly higher in the body shop section than in the paint shop section, while the average concentrations of temperature and CO2 were slightly higher in the paint shop section than in the body shop section. There was no difference in the average concentrations of PM10 between the two sections.
    Matched MeSH terms: Air Pollution, Indoor/analysis*
  19. Assunta M, Fields N, Knight J, Chapman S
    Tob Control, 2004 Dec;13 Suppl 2:ii4-12.
    PMID: 15564219
    STUDY OBJECTIVE: To review the tobacco industry's Asian environmental tobacco smoke (ETS) consultants programme, focusing on three key nations: China, Hong Kong, and Malaysia.
    METHODS: Systematic keyword and opportunistic website searches of formerly private internal industry documents.
    MAIN RESULTS: The release of the 1986 US Surgeon General's report on second hand smoke provoked tobacco companies to prepare for a major threat to their industry. Asian programme activities included conducting national/international symposiums, consultant "road shows" and extensive lobbying and media activities. The industry exploited confounding factors said to be unique to Asian societies such as diet, culture and urban pollution to downplay the health risks of ETS. The industry consultants were said to be "..prepared to do the kinds of things they were recruited to do".
    CONCLUSIONS: The programme was successful in blurring the science on ETS and keeping the controversy alive both nationally and internationally. For the duration of the project, it also successfully dissuaded national policy makers from instituting comprehensive bans on smoking in public places.
    Matched MeSH terms: Air Pollution, Indoor/adverse effects
  20. Othman M, Latif MT, Matsumi Y
    Ecotoxicol Environ Saf, 2019 Apr 15;170:739-749.
    PMID: 30583285 DOI: 10.1016/j.ecoenv.2018.12.042
    It is important to assess indoor air quality in school classrooms where the air quality may significantly influence school children's health and performance. This study aims to determine the concentrations of PM2.5 and dust chemical compositions in indoor and outdoor school classroom located in Kuala Lumpur City Centre. The PM2.5 concentration was measured from 19th September 2017-16th February 2018 using an optical PM2.5 sensor. Indoor and outdoor dust was also collected from the school classrooms and ion and trace metal concentrations were analysed using ion chromatography (IC) and inductively couple plasma-mass spectrometry (ICP-MS) respectively. This study showed that the average indoor and outdoor 24 h PM2.5 was 11.2 ± 0.45 µg m-3 and 11.4 ± 0.44 µg m-3 respectively. The 8 h PM2.5 concentration ranged between 3.2 and 28 µg m-3 for indoor and 3.2 and 19 µg m-3 for outdoor classrooms. The highest ion concentration in indoor dust was Ca2+ with an average concentration of 38.5 ± 35.0 µg g-1 while for outdoor dust SO42- recorded the highest ion concentration with an average concentration of 30.6 ± 9.37 µg g-1. Dominant trace metals in both indoor and outdoor dust were Al, Fe and Zn. Principle component analysis-multiple linear regression (PCA-MLR) demonstrated that the major source of indoor dust was road dust (69%), while soil dominated the outdoor dust (74%). Health risk assessment showed that the hazard quotient (HQ) value for non-carcinogenic trace metals was indoor and outdoor dust through dermal and inhalation pathways, but not the ingestion pathway. This study suggests indoor contributions of PM2.5 concentrations are due to the activities of the school children while the compositions of indoor and outdoor dust are greatly influenced by the soil/earth source plus industrial and traffic contribution.
    Matched MeSH terms: Air Pollution, Indoor/analysis*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)