Method: Maxillary CBCT images of two-hundred-and-fifty-seven consecutive patients (163 men, 94 women, mean age 42 years) were analyzed. Samples were later divided into dentate (n = 142) and posteriorly edentulous (n = 115) jaws. Using both alveolar ridge and tooth location as reference points, the distance and diameter of IA were assessed.
Result: The IA was seen in 63.7% of all sinuses with 68.2% in dentate and 62.4% in edentulous. Mean distance and diameter of IA across the posterior tooth locations were 17.9 ± 3.0 mm and 1.4 ± 0.5 mm (dentate) and 15.1 ± 3.0 mm and 1.0 ± 0.5 mm (posteriorly edentulous), respectively. In each sample, there were no significant differences in distance-alveolar ridge and no significant correlations in diameter-tooth location. A statistically significant Pearson coefficient correlation between diameter and distance in dentate state was observed (r = -0.6).
Conclusion: This study reveals that dentate maxillary jaws present larger diameters as compared to posteriorly edentulous jaws, although the IA course remains the same. As these canal structures contain neurovascular bundles with diameters that may be large enough to cause clinically substantial complications, a thorough pre-surgical planning is therefore highly advisable.
METHODS: Five single maxillary premolar extraction sockets received PRF-CS grafts and five single maxillary premolar sockets received PRF-X grafts. Linear (horizontal and vertical) measurements were accomplished using Cone Beam Computed Tomography (CBCT) images and volumetric changes were assessed using MIMICS software. Soft tissue level changes were measured using Stonecast models. All measurements were recorded at baseline (before extraction) and at 5-months post-extraction.
RESULTS: Significant reduction in vertical and horizontal dimensions were observed in both groups except for distal bone height (DBH = 0.44 ± 0.45 mm, p = 0.09) and palatal bone height (PBH = 0.39 ± 0.34 mm, p = 0.06) in PRF-X group. PRF-CS group demonstrated mean horizontal shrinkage of 1.27 ± 0.82 mm (p = 0.02), when compared with PRF-X group (1.40 ± 0.85 mm, p = 0.02). Vertical resorption for mesial bone height (MBH = 0.56 ± 0.25 mm, p = 0.008), buccal bone height (BBH = 1.62 ± 0.91 mm, p = 0.01) and palatal bone height (PBH = 1.39 ± 0.87 mm, p = 0.02) in PRF-CS group was more than resorption in PRF-X group (MBH = 0.28 ± 0.14 mm, p = 0.01, BBH = 0.63 ± 0.39 mm, p = 0.02 and PBH = 0.39 ± 0.34 mm, p = 0.06). Volumetric bone resorption was significant within both groups (PRF-CS = 168.33 ± 63.68 mm3, p = 0.004; PRF-X = 102.88 ± 32.93 mm3, p = 0.002), though not significant (p = 0.08) when compared between groups. In PRF-X group, the distal soft tissue level (DSH = 1.00 ± 0.50 mm, p = 0.03) demonstrated almost 2 times more reduction when compared with PRF-CS group (DSH = 1.00 ± 1.00 mm, 0.08). The reduction of the buccal soft tissue level was pronounced in PRF-CS group (BSH = 2.00 ± 2.00 mm, p = 0.06) when compared with PRF-X group (BSH = 1.00 ± 1.50 mm, p = 0.05).
CONCLUSIONS: PRF-CS grafted sites showed no significant difference with PRF-X grafted sites in linear and volumetric dimensional changes and might show clinical benefits for socket augmentation. The study is officially registered with ClinicalTrials.gov Registration (NCT03851289).
OBJECTIVES: The aim of the study was to evaluate the deviation of implant placement performed with a surgical guide fabricated by means of the rapid prototyping technique (the PolyJet™ technology).
MATERIAL AND METHODS: Twenty sheep mandibles were used in the study. Pre-surgical cone-beam computed tomography (CBCT) scans were acquired for the mandibles by using the Kodak 9000 3D cone-beam system. Two implants with dimensions of 4 mm in diameter and 10 mm in length were virtually planned on the 3D models of each mandible by using the Mimics software, v. 16.0. Twenty surgical guides were designed and printed using the PolyJet technology. A total of 40 implants were placed using the surgical guides, 1 on each side of the mandible (2 implants per mandible). The post-surgical CBCT scans of the mandibles were performed and superimposed on the pre-surgical CBCT scans. The amount of deviation between the virtually planned placement and the actual implant placement was measured, and a descriptive analysis was done.
RESULTS: The results showed that the mean deviation at the implant coronal position was 1.82 ±0.74 mm, the mean deviation at the implant apex was 1.54 ±0.88 mm, the mean depth deviation was 0.44 ±0.32 mm, and the mean angular deviation was 3.01 ±1.98°.
CONCLUSIONS: The deviation of dental implant placement performed with a 3D-printed surgical guide (the PolyJet technology) is within the acceptable 2-millimeter limit reported in the literature.
METHODOLOGY: A total of 700 maxillary premolars were examined using CBCT in an Egyptian subpopulation. The number of roots was identified, and root canal configurations were classified according to Vertucci's classification and a new system for classifying root and canal morphology. In addition, the position where roots bifurcated and the levels where canals merged or diverged were identified. Fisher's exact test and independent t-test were used for statistical analysis, and the level of significance was set at 0.05 (P = 0.05).
RESULTS: More than half of maxillary first premolars were double-rooted, and the majority of maxillary second premolars were single-rooted (P
Methods: Retrospective analysis of 100 CBCT scans (n = 200) was performed on both sides of the mandible. Cross-sectional and panoramic images were reconstructed. The length of the MIC and the horizontal distances between the MIC and the buccal and the lingual cortical plates were measured at the three different points (starting, mid-, end points). Independent samples t-test and one-way ANOVA test were used to analyse the variation in the length and course of the MIC in gender, age, dental status and Malaysian races.
Results: The mean length of the MIC was 11.31 ± 2.65 mm, with the Malays having the longest MIC, followed by the Chinese and the Indians (p
METHODS: Five sectioned maxilla of adult Dorper male sheep were scanned using a CBCT system with a resolution of 76 μm3 (Kodak 9000). The CBCT images were reconstructed using different reconstruction parameters and analysed. The effect of reconstruction voxel size (76, 100 and 200 μm3) and threshold values (±15% from the global threshold value) on trabecular bone microstructure measurement was assessed using image analysis software (CT analyser version 1.15).
RESULTS: There was no significant difference in trabecular bone microstructure measurement between the reconstruction voxel sizes, but a significant difference (Tb.N = 0.03, Tb.Sp = 0.04, Tb.Th = 0.01, BV/TV = 0.00) was apparent when the global threshold value was decreased by 15%.
CONCLUSIONS: Trabecular bone microstructure measurements are not compromised by changing the CBCT reconstruction voxel size. However, measurements can be affected when applying a threshold value of less than 15% of the recommended global value.
Materials and Methods: Freshly extracted mandibular teeth with sample size of thirty were carefully chosen and instrumented using the 2Shape and WOG rotary files. Preoperative and postinstrumentation cone-beam computed tomographic scans were done to accomplish mesial and distal dentin walls' measurements and volume of removed dentin calculations, apical transportation, and centering ratio. Statistical analysis was performed and confirmed by independent t-test. Statistical significance was set at 5%.
Results: When shaping ability of 2Shape and WOG was evaluated, it was reported that there was no statistically significant differences noted among the groups in relation to the total volume of removed dentin, apical transportation, and centering ratio.
Conclusion: It can be concluded that 2Shape and WOG preserved the original canal anatomy well and did not eliminate excess dentin during shaping and cleaning. Rotary nickel-titanium files which work on the principle of rotary movement attained an outcome analogous to that of the rotary files working on reciprocating motion in relation to alteration in angle.
DESIGN: A digitally derived 3-dimensional maxillary model incorporating the palatal defect was generated from the patient's existing cone beam computerized tomography data and compared with the scanned cast from the conventional impression for linear dimensions, area, and volume. The digitally derived cast was 3-dimensionally printed and the obturator fabricated using traditional techniques. Similarly, an obturator was fabricated from the conventional cast and the fit of both final obturator bulbs were compared in vivo.
RESULTS: The digitally derived model produced more accurate volumes and surface areas within the defect. The defect margins and peripheries were overestimated which was reflected clinically.
CONCLUSION: The digitally derived model provided advantages in the fabrication of the palatal obturator; however, further clinical research is required to refine consistency.
METHODS: In 24 participants, 140-200 g of force was applied for mandibular canine retraction. Three MOPs were made according to the scheduled intervals of the 3 different groups: group 1 (MOP 4 weeks), group 2 (MOP 8 weeks), and group 3 (MOP 12 weeks) directly at the mandibular buccal cortical bone of extracted first premolars sites. Cone-beam computed tomography scans were obtained at the 12th week after MOP application. Computed tomography Analyzer software (version 1.11.0.0; Skyscan, Kontich, Belgium) was used to compute the trabecular alveolar BV/TV ratio.
RESULTS: A significant difference was observed in the rate of canine movement between control and MOP. Paired t test analysis showed a significant difference (P = 0.001) in the mean BV/TV ratio between control and MOP sides in all the frequency intervals groups. However, the difference was significant only in group 1 (P = 0.014). A strong negative correlation (r = -0.86) was observed between the rate of canine tooth movement and the BV/TV ratio at the MOP side for group 1 and all frequency intervals together (r = -0.42).
CONCLUSIONS: The rate of orthodontic tooth movement can be accelerated by the MOP technique with frequently repeated MOPs throughout the treatment.
METHODOLOGY: A literature search was performed in Elsevier's Scopus database to locate all the publications of the International Endodontic Journal. Various bibliometric software packages including the open-source visualization software Gephi and Biblioshiny (version 2.0) were employed for data visualization and analysis.
RESULTS: A total of 3739 records with citation and bibliographic details were selected and retrieved to allow a bibliometric analysis to be performed. The bibliometric analysis indicates that the IEJ has grown both in terms of productivity and influence. Over time, the journal has been associated with an increase in the number of manuscripts published and the citations they have attracted, but with minor downward fluctuations in citations in the last few years. Bibliographic coupling of the IEJ articles revealed that the major research themes published in the journal include 'endodontics', 'root canal treatment', 'calcium hydroxide', 'apical periodontitis', 'mineral trioxide aggregate', 'microbiology', 'cyclic fatigue', 'cone-beam computed tomography' and 'micro-computed tomography'. Authors affiliated to institutions in the UK were the major contributors to the journal and were linked with other countries such as Brazil, USA and Malaysia. The largest number of publications were from the University of São Paulo, Brazil.
CONCLUSION: The IEJ is one of the leading journals in Endodontology and has been providing a platform for innovative research and clinical reports for more than 50 years. Publications have been associated with a wide range of authors, institutions and countries around the world.
METHODS: Six hemi-mandible samples were scanned using the i-CAT CBCT system. The scanned data was transferred to the OsiriX software for measurement protocol and subsequently into Mimics software to fabricate customized cutting jigs and 3D biomodels based on rapid prototyping technology. The hemi-mandibles were segmented into 5 dentoalveolar blocks using the customized jigs. Digital calliper was used to measure six distances surrounding the mandibular canal on each section. The same distances were measured on the corresponding cross-sectional OsiriX images and the 3D biomodels of each dentoalveolar block.
RESULTS: Statistically no significant difference was found when measurements from OsiriX images and 3D biomodels were compared to the "gold standard" -direct digital calliper measurement of the cadaveric dentoalveolar blocks. Moreover, the mean value difference of the various measurements between the different study components was also minimal.
CONCLUSION: Various distances surrounding the mandibular canal from 3D biomodels produced from the CBCT scanned data was similar to that of direct digital calliper measurements of the cadaveric specimens.
Materials and Methods: A 3D prototype of a mandibular premolar was generated by Digital Imaging and Communications in Medicine (DICOM) images obtained from the cone beam computed tomography and imported to 3D modeling software tool, SpaceClaim. The four distinct load magnitudes of 100, 150, 200, and 250N were applied as a pressure load perpendicular to the lingual plane of the lingual cusp of the occlusal surface (normal load) and at 45° to same (oblique load). The stress distribution patterns and the maximum von Mises stresses were analyzed and compared.
Results: The occlusal stresses were distributed from the force loading point in an approximate actinomorphic pattern, and when the force load was close to the margin, the stress was much greater.
Conclusion: Ovoid cavity showed lesser stress concentration and deformation for each of the tested restorative material.
METHODOLOGY: The Web of Science database was searched to retrieve all the manuscripts published in the IEJ and JOE between 1980 and 2019. The articles were analysed using the VOS viewer software and the terms within the titles extracted. The top-10 terms were categorized according to the number of occurrences and the decade of publication. Maps were created using the text data for each decade of publication. Classic papers were identified when the number of citations was >400. During the same period of time, highly cited studies were identified including the authors, institutions and countries associated with these papers.
RESULTS: Terms such as canal, molar and periapical lesion were the most commonly used in titles between 1980 and 1999. The terms instruments, expression, case report and cell were the most often terms used between 2000 and 2019. During the last 10 years, an increase in the number of reviews and papers on cone beam computed tomography occurred. The organizations with the largest number of citations in each decade were University of São Paulo, University College London, Loma Linda University and United States Army. The country with the largest number of citations and greatest number of top 10 and top 100 manuscripts was the United States. A paper had to be associated with more than 167 citations to be included in the top-100 most-cited list; at least 14 papers met the criteria to be categorized as a citation classic (>400 citations).
CONCLUSION: While many diverse areas of endodontics have been explored in the last 40 years within the IEJ and JOE, only a relatively few topics are highly cited and can be considered as classics.