Displaying publications 21 - 40 of 75 in total

Abstract:
Sort:
  1. Yi Wen L, Singh S, Mohamad NFB, Toh YF, Khalil AAK
    Ophthalmic Plast Reconstr Surg, 2020 5 20;37(1):e23-e25.
    PMID: 32427737 DOI: 10.1097/IOP.0000000000001713
    Simple bone cyst is a benign osteolytic lesion, found primarily in the mandible, occasionally in the maxilla, and rarely in the zygoma. A 17-year-old male patient with 6-month history of left facial mass presented with worsening proptosis and displacement of left eyeball associated with reduced OS vision. The lesion was painless to start with, but with time, he reported OS pain. There was no history of any trauma. CT scan and MRI of orbit performed revealed cystic bony lesion involving greater wing of sphenoid. He subsequently had excision of the left facial mass with exenteration of OS due to poor visual prognosis, followed by reconstruction with osteomyocutaneous flap from left scapular region. The histopathologic features were consistent with a diagnosis of simple bone cyst of zygomatic arch.
    Matched MeSH terms: Orbit
  2. Saad AZM, Nordin NR, Sulaiman WAW, Jamayet N, Johar SFNM, Hussein A
    Arch Plast Surg, 2021 Jan;48(1):80-83.
    PMID: 33503749 DOI: 10.5999/aps.2020.00206
    Eye socket contracture is a well-known late complication of enucleation surgery, and the additional insult of radiotherapy at an early age causes even further fibrosis and scarring of the socket. Management of the contracted socket is challenging, and several methods have been proposed. We report a case of eye socket contracture after enucleation and radiotherapy in which multiple reconstructive procedures failed. The recurrent contracture caused difficulty in housing and retaining the eye prosthesis. We reconstructed the lower eyelid with a facial artery myomucosal flap and nasolabial flap, and the upper eyelid with a Fricke flap following reconstruction of the orbital rims (supraorbital and infraorbital rims with a calvarial bone graft, and further augmentation of the infraorbital rim with a rib bone graft). Cosmesis post-reconstruction was acceptable and the prosthesis was retained very well.
    Matched MeSH terms: Orbit
  3. Ruhana Hassan, Nur Fatimah Mohd Azizi, Muhammad Amirul Arib Md Adzhar, Mohd Izwan Zulaini Abdul Gani, Rambli Ahmad, Charles Leh Moi Ung
    MyJurnal
    This study documented details of the dentitions, skulls and other skeletal remains of Crocodylus porosus and Tomistoma schlegelii, from western part of Sarawak, Malaysian Borneo. The remains of both reptiles were exhumed, followed by standard cleaning procedures and then detail morphological assessments were carried out accordingly. Both species show similar structure of vertebral columns, but T. schlegelii has the following unique structures: a long and narrower snout, D-shaped eye sockets, long and sharp pointed protruding quadratojugal bones, straight maxillae and dentary, a smooth surfaced skull, elongated triangular suborbital fenestrae, round shaped internal nares and visible supraoccipital from a dorsal view. C. porosus has heterodont dentition with blunt-pointed and irregular size of teeth whereas T. schlegelii has almost homodont dentition with sharp and similar size teeth. This is the first collection of teeth, skulls and other skeletal remains of both species obtained from Sarawak, and the materials have been used regularly to educate the public through science exhibitions, hoping they will spark the interests of young budding scientists to be involved in wildlife taphonomic studies in the future.
    Matched MeSH terms: Orbit
  4. Hisamuddin Shah, N.H., Lim, H.S., Mat Jafri, M.Z.
    MyJurnal
    Ultraviolet radiation is at shorter wavelengths than the visible spectrum (400 to 700 nm) and is divided into three components: UV-A (315 to 400 nm), UV-B (280 to 315 nm), and UV-C (less than 280 nm). Global increases in UV-B fluxes from decreasing stratospheric ozone amounts caused by anthropogenic chlorine releasing gases (mostly chlorofluorocarbons) have been a matter of public concern for the past 20 years. This surface UV irradiance data retrieved from Ozone Monitoring Instrument (OMI) from AURA spacecraft with the filename OMUVB. OMUVB contains surface UV irradiance data along with supplementary information generated using the OMI global mode measurements. In this mode each file contains the sunlit portion of a single orbit from pole-to-pole, with an approximately 2600 km wide swath composed of 60 ground pixels. The OMI measurements are used to estimate the ultraviolet (UV) radiation reaching the Earth’s surface. The product contains spectral irradiances at 305.1, 310.1, 324.1, and 380.1 nm corresponding to both the overpass time and the local solar noon. Using the correspondence latitude and longitude of Peninsular Malaysia, we can develop the pattern of distribution of UV irradiance interpolations using Sigma Plot and Adobe Photoshop.
    Matched MeSH terms: Orbit
  5. Norhani Mohidin, Chia, Jho Yan, Mohd Norhafizun Mohd Saman, Nazeem Desai
    MyJurnal
    Patients who lost their eyes as results of accidents or diseases (e.g. retinoblastoma) usually underwent enucleation or evisceration. They were then fi tted with ocular prosthesis to prevent collapse of the globe and also for cosmetic effects. Custom made ocular prosthesis is almost unheard of in this country for most hospitals supply ready-made (stock) prosthesis. The cosmetic results of stock prosthesis are often unsatisfactory. Besides being uncomfortable, stock prosthesis may also induce allergic reaction that may lead to papillary conjunctivitis. The Optometry Clinic at UKM started its custom made prosthetic service in 2010. We described here two cases of patients who complained of discomfort with their old stock prosthesis and re-fitted with custom made prosthesis. We also highlight the importance of proper hygiene and maintenance so that ocular prosthesis can be used for as long as possible. This article aims to create awareness among eye care practitioners and showcase the cosmetic benefi ts of custom made ocular prosthesis.
    Study site: Optometry clinic, Universiti Kebangsaan Malaysia, Kuala Lumpur, Malaysia


    Matched MeSH terms: Orbit
  6. Irfan, M., Dinsuhaimi, S., Roselinda, A.R., Rani, A.S.
    MyJurnal
    Mucoceles are expansile masses originating in the sinuses. They are relatively unusual, occurring most frequently at fronto-ethmoidal region. They are locally destructive. This expansile lesion caused bony erosion and displaces the adjacent structures. We report a case of a patient who presented to our clinic with bulging of his left eye and worsening of the left vision. This was preceded by history of sport injury to his left supraorbital ridge. CT scan revealed that there was an extraconal lesion at the superolateral part of the left orbital cavity which pushed the orbit inferomedially, which consistent with left frontomucocele. He underwent enucleation of the lesion via 3 windows created namely at the left supraorbital ridge, anterior table of left frontal sinus and through the septum separating the frontal sinuses.
    Matched MeSH terms: Orbit
  7. Mansharan Kaur Chainchel Singh
    MyJurnal
    Solitary fibrous tumours (SFTs) are unusual mesenchymal tumours that were first described as primary spindle-cell neoplasms of the pleura. These tumours have been described in many other locations, including the urogenital system, orbit, mediastinum, and upper respiratory tract. These tumours are generally benign in nature, however some of them can be locally invasive and have the potential to be malignant. Although about 12%-15% of them occur in the head and neck area, SFT of the nasal cavity and paranasal sinuses are extremely rare. We present a case of a solitary fibrous tumour arising from the right maxillary sinus in a 50 year old Chinese man.
    Matched MeSH terms: Orbit
  8. El Rassi E, Adappa ND, Battaglia P, Castelnuovo P, Dallan I, Freitag SK, et al.
    Int Forum Allergy Rhinol, 2019 07;9(7):804-812.
    PMID: 30809970 DOI: 10.1002/alr.22316
    BACKGROUND: Orbital cavernous hemangiomas (OCH) are the most common adult orbital tumor and represent an ideal index lesion for endonasal orbital tumor surgery. In order to standardize outcomes reporting, an anatomic-based staging system was developed.

    METHODS: An international, multidisciplinary panel of 23 experts in orbital tumor surgery was formed. A modified Delphi method was used to develop the cavernous hemangioma exclusively endonasal resection (CHEER) staging system with a total of 2 rounds being completed.

    RESULTS: Tumors medial to a plane along the long axis of the optic nerve may be considered amenable for an exclusively endonasal resection. In select cases, tumors may extend inferolaterally if the tumor remains below a plane from the contralateral naris through the long axis of the optic nerve (ie, plane of resectability [POR]). This definition reached consensus with 91.3% of panelists in agreement. Five stages were designed based on increasing technical resection difficulty and potential for morbidity. Stages were based on the relationship of the tumor to the extraocular muscles, the inferomedial muscular trunk of the ophthalmic artery (IMT), and orbital foramina. Staging by anatomic location also reached consensus with 87.0% of panelists in agreement. Size was not included in the staging system due to the lack of agreement on the contribution of size to resection difficulty.

    CONCLUSION: Endoscopic orbital tumor surgery is a nascent field with a growing, yet heterogeneous, body of literature. The CHEER staging system is designed to facilitate international, high-quality, standardized studies establishing the safety, efficacy, and outcomes of endonasal resection of OCH.

    Matched MeSH terms: Orbit; Orbital Neoplasms
  9. Hashim SE, Fatisha A, Nazri MN
    MyJurnal
    Subperiosteal haematoma of the orbit is an uncommon complication of maxillofacial trauma, hence easily missed. It usually presents subacutely with proptosis and diplopia. In our case, the subperiosteal haematoma is complicated with high intraocular pressure, necessisating measures to reduce the intraocular pressure. Unresponsive to only medical treatment, surgical evacuation was carried out in this patient. Removal of the clot finally relieved the intraocular pressure and simultaneously improved the proptosis and the cumbersome diplopia.
    Matched MeSH terms: Orbit
  10. Gendeh BS
    Indian J Otolaryngol Head Neck Surg, 2010 Sep;62(3):264-76.
    PMID: 23120724 DOI: 10.1007/s12070-010-0077-6
    Sinus surgery has the potential of allowing ENT surgeons to encroach the boundaries of our colleagues in ophthalmology and neurosurgery. The advent of nasal endoscope and lately powered instrumentation and computer-assisted navigational systems has avoided the use of the conventional and more radical approaches by the ENT surgeon for the treatment of inflammatory pathology or tumors of the orbit and skull base. As rhinologists have gained more experience in endoscopic surgery, more areas related to the orbit and the anterior skull base are accessible and surgery is safer.
    Matched MeSH terms: Orbit
  11. Chong AW, Prepageran N, Rahmat O, Subrayan V, Jalaludin MA
    Ear Nose Throat J, 2011 Feb;90(2):E13.
    PMID: 21328215
    We report the rare occurrence of bilateral asymmetrical mucoceles of the paranasal sinuses that resulted in a unilateral orbital complication. The patient was a 47-year-old woman who presented with complaints of diplopia, blurred vision, and protrusion of her right eye that had progressed over a period of several months following an upper respiratory tract infection. Computed tomography detected the presence of two large, asymmetrical mucoceles. The lesion on the right involved the frontal and ethmoid sinuses, and the one on the left involved the ethmoid sinus. The mucoceles were locally expansile and had eroded the surrounding bony structures on the right. The expansile nature of the right-sided mass had displaced the right orbit, which was the cause of the vision deterioration. Transnasal endoscopic surgery was performed to excise and marsupialize the mucoceles. This modality was preferred over conventional open surgery because it affords good visualization, it is safe, and it is a less morbid procedure. The patient's recovery was uneventful, and she was discharged home on the third postoperative day. On continuing follow-up, her vision had improved, her intraocular pressure had returned to normal, and her orbits were in their normal position. Based on our literature search, no case of bilateral frontal and ethmoid sinus mucoceles has been previously reported.
    Matched MeSH terms: Orbit/radiography
  12. Ramli N, Kala S, Samsudin A, Rahmat K, Abidin ZZ
    Orbit, 2015;34(5):257-62.
    PMID: 26186249 DOI: 10.3109/01676830.2015.1057291
    To determine the correlation and agreement between Hertel exophthalmometry and computed tomography (CT) of the orbits in measuring proptosis.
    Matched MeSH terms: Orbit/radiography*
  13. Shriwas SR, Kinzha AZ
    Indian J Ophthalmol, 1993 Oct;41(3):129-30.
    PMID: 8125546
    Matched MeSH terms: Orbit/injuries*
  14. Jaais F, Habib ZA
    Med J Malaysia, 1994 Dec;49(4):416-8.
    PMID: 7674980
    A patient on oral contraceptives over several years developed unilateral proptosis, haemorrhagic retinopathy and increase in intraocular pressure. An orbital vein venogram confirmed the diagnosis of right superior ophthalmic vein thrombosis. There was complete resolution of thrombosis and eye signs and symptoms with discontinuation of the oral contraceptive.
    Matched MeSH terms: Orbit/blood supply*
  15. Singh J, Rahman RA, Rajion ZA, Abdullah J, Mohamad I
    J Craniofac Surg, 2017 Jan;28(1):e64-e70.
    PMID: 27922969 DOI: 10.1097/SCS.0000000000003218
    INTRODUCTION: The human orbit is a complex anatomic region, which plays predominant role in the evaluation of craniofacial complex. A thorough understanding of the relationship of the distance from orbital rim to the important vital structures of the orbital apex is required for the surgeon to perform safe and effective surgery.

    OBJECTIVES: To evaluate and compare the depth and distances from various points of the orbital rim to the fissures and foramina of the orbital apex between genders in the local population.

    METHODOLOGY: Linear measurements were conducted on 60 orbits from 30 patients who had undergone head computed tomography scan. These measurements were done utilizing the multiplanar reconstruction modes on computed tomography images with minimum slice thickness of 1 mm.

    RESULTS: Males have statistically significant larger orbits than females with higher mean measurements in all parameters, except for the distance from posterior ethmoidal foramen to the optic canal which was the same. However, there were no significant differences in all parameters between the right and left orbits.

    CONCLUSION: This study provides the absolute limit of safe internal orbital dissection in respect to the local population. Despite males having larger orbits than females, it is clinically negligible.

    Matched MeSH terms: Orbit/anatomy & histology*
  16. Kumaran A, Chan A, Yong K, Shen S
    Orbit, 2019 Apr;38(2):95-102.
    PMID: 29482415 DOI: 10.1080/01676830.2018.1441316
    AIM: To describe differences in the deep lateral orbital wall (specifically, trigone) between Chinese, Malay, Indian and Caucasian subjects Methods: Single-centre retrospective Computed Tomogram (CT)-based study; 20 subjects of each ethnicity were used from existing databases, matched for gender, average age and laterality. Subjects below 16 years of age were excluded. DICOM image viewing software CARESTREAM Vue PACS (Carestream Health Inc., USA) and OsiriX version 7.5 (Pixmeo., Switzerland) were used to measure deep lateral wall length, thickness and volume, as well as orbital depth and statistical analyses performed using Statistical Package for Social Sciences version 21 (IBM, USA).

    RESULTS: In each group, there were 12 males (60%) and average age was not significantly different (p = 0.682-0.987). Using Chinese subjects as a reference, in Chinese, Malay, Indian and Caucasian subjects, mean trigone thickness was 13.68, 14.02, 11.60 (p orbital depth was 27.54, 24.97, 22.12 (p = 0.001) and 25.93 mm and diagonal orbital depth was 34.19, 33.27, 29.48 (p = 0.01) and 34.63 mm respectively.

    CONCLUSIONS: Indian and, to a lesser extent, Caucasian subjects have smaller trigones compared to their Chinese and Malay counterparts. Indian subjects also have shallower orbits and due care should be taken during decompression surgery.

    Matched MeSH terms: Orbit/anatomy & histology*; Orbit/surgery
  17. Manuel AM, Kalimuthu S, Pathmanathan SS, Narayanan P, Zainal Abidin Z, Azmi K, et al.
    Asian J Surg, 2017 Apr;40(2):158-162.
    PMID: 24210537 DOI: 10.1016/j.asjsur.2013.09.011
    Arteriovenous malformations are congenital lesions that may evolve with time and manifest in a plethora of presentations. They can occur as torrential epistaxis when it extensively involves the facial region. Multi-imaging modalities are available to assist in characterizing the structure of the lesion as well as its location and extent. This complex disease requires a multidisciplinary team approach with preoperative embolization and surgery. We present a rare cause of life-threatening epistaxis in a gentleman with a longstanding orbital and hemifacial arteriovenous malformation and discuss the complexities involved in its management.
    Matched MeSH terms: Orbit/blood supply; Orbit Evisceration/methods
  18. Ng YS, Gan YK, Tupang L
    Turk J Ophthalmol, 2021 Feb 25;51(1):62-65.
    PMID: 33631919 DOI: 10.4274/tjo.galenos.2020.00225
    An 88-year-old woman was brought to the hospital immediately after her neighbours noticed that she was bleeding from her right eye. On examination, her right eye was phthisic with maggot infestation of her right orbit. Over a hundred live maggots were extracted using forceps. Computed tomography scan revealed the infestation was confined to the right orbit. The patient underwent exenteration of the right orbit under general anaesthesia. The species was identified by an entomologist as Chrysomya bezziana, which has aggressive larvae that eat living tissue. This case report demonstrates that orbital myiasis caused by C. bezziana poses a very real risk of intracranial invasion as they feed on living tissues. Adjacent tissue destruction can be very rapid and definitive treatment involves urgent removal of its larvae via surgical debridement. To our knowledge, we are reporting the first case of orbital myiasis from a patient in Malaysia. Therefore, our case report may be helpful in the management of similar case of orbital myiasis.
    Matched MeSH terms: Orbit
  19. Razali NR, Choo YM
    Malays Fam Physician, 2021 Mar 25;16(1):136-138.
    PMID: 33948155 DOI: 10.51866/cr1010
    Acute ptosis due to preseptal cellulitis requires urgent medical attention, as the infection can extend posteriorly into the orbit, leading to significant visual and cerebral complications. We report a case of a 58-year-old woman with uncontrolled diabetes mellitus presenting with acute ptosis due to preseptal cellulitis. After initial resolution of fever with intravenous amoxicillin-clavulanate, she experienced a seizure due to cerebral abscess a week later and was treated with intravenous ceftriaxone. Preseptal cellulitis is usually treated on an outpatient basis with oral antibiotics, as it rarely extends posteriorly to cause cerebral complications. We wish to highlight the importance of admitting patients with preseptal cellulitis in patients with uncontrolled diabetes for intravenous antibiotics due to the potential for visual and cerebral complications.
    Matched MeSH terms: Orbit
  20. Sadacharan CM, Packirisamy V
    J Craniofac Surg, 2020 Jul 14.
    PMID: 32675767 DOI: 10.1097/SCS.0000000000006757
    In cosmetic surgery, knowledge of the average dimensions of periorbital features based on gender and ethnicity is essential to improve the patient appearance and maintain the ethnicity. The aim the study was to establish gender-specific periorbital anthropometric and anthroposcopic data for Indian Americans (IA) and to assess the statistically ethnic differences by comparing with published data of Malaysian Indians (MI). Evaluation of periorbital features was done on the standardized frontal photographs of 400 IA, aged 18 to 26 years. The measured values were evaluated by an independent t-test. Sexual dimorphism was found in all 15 measurements. The eyebrow height, combined height of the orbit and eyebrow, eyebrow apex inclination, apex to lateral canthus distance, medial end of brow to medial canthus distance, lateral end of brow to lateral canthus distance; pretarsal skin height, palpebral fissure height, palpebral fissure inclination (PFI), and medial canthus tilt were significantly greater in female than the males. In males, eyebrow apex hairline distance, apex to lateral limbus distance, eyebrow apex angle (EAA), lower eyelid height, and interpupillary distance was significantly greater than the females. Significant ethnic difference was found between IA and MI for eyebrow height, apex to lateral limbus distance, EAA, palpebral fissure height, and PFI in male group. In female group, EAA, medial canthus tilt, and PFI were significantly greater in MI. Four types of epicanthus were observed and the brow apex between lateral limbus and lateral canthus was the most common position. The generated normative data may be useful during diagnosis and treatment planning.
    Matched MeSH terms: Orbit
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links