Displaying publications 21 - 40 of 69 in total

Abstract:
Sort:
  1. Tamin SS, Hussin A, Za I, Halmey N, Azman W
    Pacing Clin Electrophysiol, 2007 Feb;30(2):276-9.
    PMID: 17338728
    Coronary sinus perforation is a relatively uncommon but much feared complication that may occur during the placement of left ventricular pacing lead. Coronary sinus perforation, especially in the presence of an obstructive flap, usually indicates the need to abandon the implantation attempt, as there are difficulties in crossing the obstructive flap as well as uncertainty of whether the lead is in the true lumen or into the pericardial space. We describe our experience in successfully placing the left ventricular lead safely despite the problems arising from these circumstances.
    Matched MeSH terms: Prosthesis Implantation/adverse effects*; Prosthesis Implantation/methods*
  2. El-Chami MF, Clementy N, Garweg C, Omar R, Duray GZ, Gornick CC, et al.
    JACC Clin Electrophysiol, 2019 02;5(2):162-170.
    PMID: 30784685 DOI: 10.1016/j.jacep.2018.12.008
    OBJECTIVES: This study sought to report periprocedural outcomes and intermediate-term follow-up of hemodialysis patients undergoing Micra implantation.

    BACKGROUND: Leadless pacemakers may be preferred in patients with limited vascular access and high-infection risk, such as patients on hemodialysis.

    METHODS: Patients on hemodialysis at the time of Micra implantation attempt (n = 201 of 2,819; 7%) from the Micra Transcatheter Pacing Study investigational device exemption trial, Micra Transcatheter Pacing System Continued Access Study Protocol, and Micra Transcatheter Pacing System Post-Approval Registry were included in the analysis. Baseline characteristics, periprocedural outcomes, and intermediate-term follow-up were summarized.

    RESULTS: Patients on hemodialysis at the time of Micra implantation attempt were on average 70.5 ± 13.5 years of age and 59.2% were male. The dialysis patients commonly had hypertension (80%), diabetes (61%), coronary artery disease (39%), and congestive heart failure (27%), and 72% had a condition that the implanting physician felt precluded the use of a transvenous pacemaker. Micra was successfully implanted in 197 patients (98.0%). Reasons for unsuccessful implantation included inadequate thresholds (n = 2) and pericardial effusion (n = 2). The median implantation time was 27 min (interquartile range: 20 to 39 min). There were 3 procedure-related deaths: 1 due to metabolic acidosis following a prolonged procedure duration in a patient undergoing concomitant atrioventricular nodal ablation and 2 deaths occurred in patients who needed surgical repair after perforation. Average follow-up was 6.2 months (range 0 to 26.7 months). No patients had a device-related infection or required device removal because of bacteremia.

    CONCLUSIONS: Leadless pacemakers represent an effective pacing option in this challenging patient population on chronic hemodialysis. The risk of infection appears low with an acceptable safety profile. (Micra Transcatheter Pacing Study; NCT02004873; Micra Transcatheter Pacing System Continued Access Study Protocol; NCT02488681; Micra Transcatheter Pacing System Post-Approval Registry; NCT02536118).

    Matched MeSH terms: Prosthesis Implantation/adverse effects; Prosthesis Implantation/instrumentation; Prosthesis Implantation/mortality; Prosthesis Implantation/statistics & numerical data
  3. Qureshi AU, Abbaker AE, Sivalingam S, Latiff HA
    PMID: 24668992 DOI: 10.1177/2150135113509819
    Valved bovine jugular vein (Contegra) conduit is considered a suitable choice for pediatric population with congenital heart defect requiring right ventricle to main pulmonary artery connection. Intermediate follow-up studies have shown the propensity of developing distal conduit stenosis and valve thrombosis. We present a rare case of aneurysmal dilatation of the conduit leading to valve failure requiring conduit explantation.
    Matched MeSH terms: Blood Vessel Prosthesis Implantation/adverse effects*; Heart Valve Prosthesis Implantation/adverse effects*
  4. Jamayet NB, Kirangi JK, Husein A, Alam MK
    Eur J Dent, 2017 4 25;11(1):130-134.
    PMID: 28435380 DOI: 10.4103/1305-7456.202636
    Enucleation and evisceration are the most common surgical procedures that are performed to manage tumor, trauma, and infection. Given the consequences of surgical intervention, the conditions of the remaining eye socket may affect future prosthetic rehabilitation. A custom-made ocular prosthesis can be used to help restore the esthetics and functional defects and to improve the quality of life of patients with such conditions. An assessment must be performed on the prosthetic outcome before rehabilitation. The etiology of defect, type of surgery, condition of the remaining socket, and patient's age should all be considered. This report discusses three different etiological eye defects that have undergone enucleation and evisceration and describes the factors that have a significant role in the esthetic and functional outcome of the prosthesis. This report should serve as a helpful aid for maxillofacial prosthodontists to understand the primary objective of rehabilitating each eye defect and to meet patient expectations.
    Matched MeSH terms: Prosthesis Implantation
  5. Sologashvili T, Saat SA, Tille JC, De Valence S, Mugnai D, Giliberto JP, et al.
    Eur J Pharm Biopharm, 2019 Jun;139:272-278.
    PMID: 31004790 DOI: 10.1016/j.ejpb.2019.04.012
    OBJECTIVE: Vascular prostheses for small caliber bypass grafts in cardiac and vascular diseases or for access surgery are still missing. Poly (Ɛ-caprolactone) (PCL) has been previously investigated by our group and showed good biocompatibility and mechanical properties in vitro and rapid endothelialisation, cellular infiltration and vascularisation in vivo yielding optimal patency in the abdominal aortic position. The aim of the present study is to evaluate our PCL graft in the carotid position and to compare its outcome to the grafts implanted in the abdominal aortic position.

    METHODS: PCL grafts (1 mm ID/10 mm long) were implanted into the left common carotid artery in 20 Sprague-Dawley rats and compared to our previously published series of abdominal aortic implants. The animals were followed up to 3, 6, 12 and 24 weeks. At each time point, in vivo compliance, angiography and histological examination with morphology were performed.

    RESULTS: PCL grafts showed good mechanical properties and ease of handling. The average graft compliance was 14.5 ± 1.7%/ mmHg compared to 7.8 ± 0.9% for the abdominal position and 45.1 ± 3.2%/ mmHg for the native carotid artery. The overall patency for the carotid position was 65% as compared to 100% in the abdominal position. Complete endothelialisation was achieved at 3 weeks and cell invasion was more rapid than in the aortic position. In contrast, intimal hyperplasia (IH) and vascular density were less pronounced than in the aortic position.

    CONCLUSION: Our PCL grafts in the carotid position were well endothelialised with early cellular infiltration, higher compliance, lower IH and calcification compared to the similar grafts implanted in the aortic position. However, there was a higher occlusion rate compared to our abdominal aorta series. Anatomical position, compliance mismatch, flow conditions may answer the difference in patency seen.

    Matched MeSH terms: Blood Vessel Prosthesis Implantation/adverse effects; Blood Vessel Prosthesis Implantation/instrumentation; Blood Vessel Prosthesis Implantation/methods*
  6. Farook TH, Abdullah JY, Jamayet NB, Alam MK
    J Prosthet Dent, 2021 Feb 15.
    PMID: 33602541 DOI: 10.1016/j.prosdent.2020.07.039
    STATEMENT OF PROBLEM: Computer-aided design (CAD) of maxillofacial prostheses is a hardware-intensive process. The greater the mesh detail is, the more processing power is required from the computer. A reduction in mesh quality has been shown to reduce workload on computers, yet no reference value of reduction is present for intraoral prostheses that can be applied during the design.

    PURPOSE: The purpose of this simulation study was to establish a reference percentage value that can be used to effectively reduce the size and polygons of the 3D mesh without drastically affecting the dimensions of the prosthesis itself.

    MATERIAL AND METHODS: Fifteen different maxillary palatal defects were simulated on a dental cast and scanned to create 3D casts. Digital bulbs were fabricated from the casts. Conventional bulbs for the defects were fabricated, scanned, and compared with the digital bulb to serve as a control. The polygon parameters of digital bulbs were then reduced by different percentages (75%, 50%, 25%, 10%, 5%, and 1% of the original mesh) which created a total of 105 meshes across 7 mesh groups. The reduced mesh files were compared individually with the original design in an open-source point cloud comparison software program. The parameters of comparison used in this study were Hausdorff distance (HD), Dice similarity coefficient (DSC), and volume.

    RESULTS: The reduction in file size was directly proportional to the amount of mesh reduction. There were minute yet insignificant differences in volume (P>.05) across all mesh groups, with significant differences (P

    Matched MeSH terms: Prosthesis Implantation
  7. Norhani Mohidin, Chia, Jho Yan, Mohd Norhafizun Mohd Saman, Nazeem Desai
    MyJurnal
    Patients who lost their eyes as results of accidents or diseases (e.g. retinoblastoma) usually underwent enucleation or evisceration. They were then fi tted with ocular prosthesis to prevent collapse of the globe and also for cosmetic effects. Custom made ocular prosthesis is almost unheard of in this country for most hospitals supply ready-made (stock) prosthesis. The cosmetic results of stock prosthesis are often unsatisfactory. Besides being uncomfortable, stock prosthesis may also induce allergic reaction that may lead to papillary conjunctivitis. The Optometry Clinic at UKM started its custom made prosthetic service in 2010. We described here two cases of patients who complained of discomfort with their old stock prosthesis and re-fitted with custom made prosthesis. We also highlight the importance of proper hygiene and maintenance so that ocular prosthesis can be used for as long as possible. This article aims to create awareness among eye care practitioners and showcase the cosmetic benefi ts of custom made ocular prosthesis.
    Study site: Optometry clinic, Universiti Kebangsaan Malaysia, Kuala Lumpur, Malaysia


    Matched MeSH terms: Prosthesis Implantation
  8. Zainuddin NAMN, Razak NAA, Karim MSA, Osman NAA
    Sci Rep, 2023 Feb 15;13(1):2664.
    PMID: 36792914 DOI: 10.1038/s41598-022-21990-y
    Acrylic and epoxy are common types of resin used in fabricating sockets. Different types of resin will affect the internal surface of a laminated socket. This paper is to determine the best combination of ratio for epoxy and acrylic resin for a laminated prosthesis socket and to evaluate the surface profile analysis of different combinations of laminated prosthetic sockets for surface roughness. Transfemoral sockets were created using various resin-to-hardener ratios of 2:1, 3:1, 3:2, 2:3, and 1:3 for epoxy resin and 100:1, 100:2, 100:3, 100:4, and 100:5 for acrylic resin. Eight layers of stockinette consisting of four elastic stockinette and four Perlon stockinette were used. A sample with a size of 4 cm × 6 cm was cut out from the socket on the lateral side below the Greater Trochanter area. The Mitutoyo Sj-210 Surface Tester stylus was run through the sample and gave the Average Surface Roughness value (Ra), Root Mean Square Roughness value (Rq), and Ten-Point Mean Roughness value (Rz). Epoxy resin shows a smoother surface compared to acrylic resin with Ra values of is 0.766 µm, 0.9716 µm, 0.9847 µm and 1.5461 µm with 3:2, 3:1, 2:1 and 2:3 ratio respectively. However, for epoxy resin with ratio 1:3, the resin does not cure with the hardener. As for acrylic resin the Ra values are 1.0086 µm, 2.362 µm, 3.372 µm, 4.762 µm and 6.074 µm with 100: 1, 100:2, 100:5, 100:4 and 100:3 ratios, respectively. Epoxy resin is a better choice in fabricating a laminated socket considering the surface produced is smoother.
    Matched MeSH terms: Prosthesis Implantation
  9. Buzayan MM
    Prosthet Orthot Int, 2014 Feb;38(1):62-7.
    PMID: 23625838 DOI: 10.1177/0309364613484052
    Mid-facial defect is one of the most disfiguring and impairing defects. A design of prosthesis that is aesthetic and stable can be precious to a patient who has lost part of his face due to surgical excision. Prosthesis can restore the patients' self-esteem and confidence, which affects the patients and their life style. The aim of this case report is to describe a technique of mid-facial silicone prosthesis fabrication.
    Matched MeSH terms: Prosthesis Implantation*
  10. Wong HS, Then KY, Ramli R
    Med J Malaysia, 2011 Oct;66(4):369-70.
    PMID: 22299563 MyJurnal
    We report the first case of Osteo-odonto-keratoprosthesis (OOKP) who successfully underwent surgery in Malaysia following a grade 4 (severe) chemical injury in both eyes in 2006. The patient's left eye was eviscerated and his right eye underwent penetrating keratoplasty. However, the corneal graft failed and became opaque. His right eye could only perceive light. The OOKP was offered to him hoping to recover some functional vision. He underwent a 2-stage surgery to implant the OOKP into his right eye. However, 2 months post-operation, he developed vitreous haemorrhage. A successful pars plana vitrectomy (PPV) was performed via the limited view through the lens. He attained a final visual acuity of 6/60 (N36). He was able to mobilize more independently, feed, dress himself and read large print.
    Matched MeSH terms: Prosthesis Implantation*
  11. Sachithanandan A, Badmanaban B
    Interact Cardiovasc Thorac Surg, 2011 Jul;13(1):100.
    PMID: 21697404 DOI: 10.1510/icvts.2010.265264A
    Matched MeSH terms: Blood Vessel Prosthesis Implantation*
  12. Izham IN, Zamrin DM, Joanna OS, Ramzisham AR, Hairolfaizi H, Ishamuddin IM, et al.
    Clin Ter, 2011;162(6):521-5.
    PMID: 22262321
    The effect of the duration of ischaemic myocardial time to left ventricular ejection fraction (LVEF) after valve replacement surgery has been attributed. This study aims to look at the correlation between myocardial ischaemic time and changes LVEF post valve replacement surgery up to 6 months period.
    Matched MeSH terms: Heart Valve Prosthesis Implantation*
  13. Irfan M, Shahid H, Baharudin A, Friedrich G
    Med J Malaysia, 2009 Mar;64(1):89-90.
    PMID: 19852333 MyJurnal
    Vocal cord palsy secondary to recurrent laryngeal nerve injury may be attributable to trauma, infiltrating neoplasm, congenital cardiac anomaly and others. Regardless the causes, majority of unilateral adductor palsy cases are usually managed by speech rehabilitation in order to allow compensation. In selected cases, medialization procedure may be required to achieve a complete glottal closure during phonation. Multiple techniques have been developed to achieve this goal. This case report illustrates the recent advancement in vocal fold medialization procedure, which has not been widely practiced in Malaysia.
    Matched MeSH terms: Prosthesis Implantation/methods*
  14. Pang YK, Liam CK, Leow CH, Shyamala P, Zal AR
    Med J Malaysia, 2006 Jun;61(2):147-50.
    PMID: 16898303 MyJurnal
    Many studies have shown that tracheobronchial stenting is effective in relieving respiratory distress secondary to major airway obstruction due to lung or oesophageal cancer. A retrospective review on the benefits and complications of self-expandable metallic stent (SEMS) insertion through flexible bronchoscopy for the palliative treatment of upper airway obstruction in University Malaya Medical Centre was performed. Ten patients underwent this procedure. Relief of dyspnoea was immediate following stent insertion in all patients. Stent migration occurred in one patient and three patients had restenosis of the central airway. We conclude that tracheobronchial stenting via flexible bronchoscopy is feasible and safe.
    Matched MeSH terms: Prosthesis Implantation/instrumentation*
  15. Razman J, Shaharin S, Lukman MR, Sukumar N, Jasmi AY
    Med J Malaysia, 2006 Jun;61(2):142-6.
    PMID: 16898302 MyJurnal
    Laparoscopic repair of ventral and incisional hernia has become increasingly popular as compared to open repair. The procedure has the advantages of minimal access surgery, reduction of post operative pain and the recurrence rate. A prospective study of laparoscopic incisional hernia repair was performed in our center from August 2002 to April 2004. Eighteen cases (n: 18) were performed during the study period. Fifteen cases (n: 15) had open hernia repair previously. Sixteen patients (n: 16) had successful repair of the hernia with the laparoscopic approach and two cases were converted to open repair. The mean hernia defect size was 156cm2. There was no intraoperative or immediate postoperative complication. The mean operating time was 100 +/- 34 minutes (75 - 180 minutes). The postoperative pain was graded as mild to moderate according to visual analogue score. The mean day of discharge after surgery was two days (1 - 3 days). During follow up, three patients (16.7%) developed seroma at the hernia sac which was resolved with conservative management after three weeks. One (5.6%) patient developed recurrence six months after surgery. In conclusion, laparoscopic repair of incisional hernia particularly recurrent hernia has been shown to be safe and effective in our centre. However, careful patient selection and acquiring the necessary advanced laparoscopic surgical skills coupled with the proper use of equipment are mandatory before embarking on this procedure.
    Matched MeSH terms: Prosthesis Implantation/methods*
  16. Hafeez YM, Zuki AB, Loqman MY, Yusof N, Asnah H, Noordin MM
    Med J Malaysia, 2004 May;59 Suppl B:117-8.
    PMID: 15468846
    The aim of this study was to evaluate bovine pericardium surgical patch in rat model. Bovine pericardial sacs collected from local abattoir were cleaned, disinfected and cut into pieces of 3 by 2.5cm and preserved in 99.5% glycerol. Full thickness abdominal wall defects of 3 by 2.5 cm were created in 30 adult male Sprague Dawley rats and repaired with glycerol preserved pieces. The rats were serially sacrificed in a group of six rats at 1,3,6,9 and 18 weeks post-surgical intervals for morphological and tensometeric study. Macroscopically, no mortality or postoperative surgical complications was encountered except slight adhesions between implanted grafts and some visceral organs in 10% of the rats. Microscopically no calcification or foreign body giant cell formation was found in the explanted grafts. The implanted grafts were replaced gradually with recipient tissue, which made mainly of dense collagenous bundles. The healing strength between the implanted grafts and the recipient abdominal wall was gradually increased with time. The results of this study showed that glycerol preserved bovine pericardium act as scaffold for transformation into living tissue without clinical complications such as that associated with prostheses.
    Matched MeSH terms: Prosthesis Implantation*
  17. Khang NC, Zainal AA
    Med J Malaysia, 2016 02;71(1):17-22.
    PMID: 27130738
    BACKGROUND: This is a single institutional review of aortoiliac pseudoaneurysm of various aetiologies managed with endovascular stent graft repair.

    METHODS: From 2009 to 2014, 16 patients had endovascular stent graft inserted for pseudoaneurysm of the thoracic aorta, abdominal aorta and iliac arteries in Hospital Kuala Lumpur. Co-morbidity, causative agents, in-hospital mortality, complications and outcomes were examined.

    RESULTS: The average age was 59.1 years (range 36-77). Comorbidities include hypertension, diabetes mellitus, tuberculosis, prior infection and previous open aneurysmal repair. All patients had raised WBC (>10.0x10(9) /L), ESR or Creactive protein on admission while 50% of patients had fever. Blood cultures were positive in 4 patients. All patients were given antibiotics. Only one in-hospital mortality was noted at day-47 post-procedure. Two patients died of aortoenteric fistula at district hospital eight and 16 months later. One patient died of chronic graft infection two years later. One died of unrelated cause. One patient developed type IB endoleak from internal iliac artery two years later and surgical ligation was performed. The average follow up was 15.8 months.

    CONCLUSION: Endovascular stent graft repair for pseudoaneurysm is a viable option compared to open surgery. It is less invasive, has lower operative morbidity and fair outcomes. However, some cases may be due to inflammatory aortitis instead of infective pseudoaneurysm, given the frequent culture-negative results. In order to obtain high yield of bacteria culture for infected pseudoaneurysm, open repair with tissue culture is still the main mode of treatment especially for patients with low comorbidity.
    Matched MeSH terms: Blood Vessel Prosthesis Implantation*
  18. Abdullah F, Adeeb S
    Heart Surg Forum, 2003;6(3):E50-1.
    PMID: 12821439
    An alternative technique of superior vena cava obstruction bypass using bovine pericardial conduit is described. The patient in this case had recurrent bilateral thrombophlebitis and thrombosed saphenous veins. Most of the surgical techniques reported in the literature so far have described the use of polyethylene terephthalate (Dacron) graft, polytetrafluoroethylene graft, autologous pericardial patch, and spiral vein graft. The use of synthetic grafts has been plagued with high rates of thrombosis. The pathology, clinical presentation, surgical technique, and outcome are discussed.
    Matched MeSH terms: Blood Vessel Prosthesis Implantation/methods*
  19. Abdulhadi LM
    Chin J Dent Res, 2010;13(1):61-6.
    PMID: 20936194
    A 70-year-old man who suffered from extensive extra and intraoral defects was rehabilitated with a prosthesis using multiple retaining means. The treatment was performed in two parts: externally involving the construction of an episthesis supported only by the remaining intact boundaries of the defect and retained by mini-dental implants and spectacle frame with a modified ear hook; and intraorally by an acrylic resin obturator to restore the function of the hemi-sectioned hard and soft palate. The episthesis was securely retained with minimal movement and/or dislodgment of the prosthesis during function. Multiple retentive techniques may be used to fix heavy external prostheses as an alternative to conventional implants or biological adhesives.
    Matched MeSH terms: Maxillofacial Prosthesis Implantation*
  20. Krishna Moorthy PS, Saat SA, Sakijan AS
    Med J Malaysia, 2019 02;74(1):94-96.
    PMID: 30846673
    This is a case report of single-stage total thoracic aortic repair by the frozen elephant trunk technique for a 75-yearold female with a complex aortic pathology of mega-aorta extending from the ascending aorta to the descending aorta. We used a Thora flex™ Hybrid device, a frozen elephant trunk device with four branched grafts and the distal stent graft. The distal stent graft was inserted into the downstream descending aorta via an aortic arch and positioned 15 cm beyond the left subclavian artery after total arch replacement had been performed using a four-branch graft. The postoperative course was unremarkable with no complications. A post procedural computed tomography scan demonstrated complete exclusion of the descending thoracic aneurysm without endoleak. Therefore, fixing the whole mega-aorta in a single stage using the frozen elephant trunk was effective and safe.
    Matched MeSH terms: Blood Vessel Prosthesis Implantation/methods