Displaying publications 21 - 40 of 2911 in total

Abstract:
Sort:
  1. Yiin CL, Quitain AT, Yusup S, Uemura Y, Sasaki M, Kida T
    Bioresour Technol, 2018 Aug;261:361-369.
    PMID: 29680702 DOI: 10.1016/j.biortech.2018.04.039
    Natural hydro-low-transition-temperature mixtures (NH-LTTMs) tend to be the most favorable next-generation green solvents for biomass pretreatment, as they are cheap and environmental friendly. The amount of water bound into the NH-LTTMs greatly affected their thermal stability, whereby the highest thermal stability was observed with the water content of 7.6 wt%. It is worth noting that, the highest molar transition energy of NH-LTTMs (47.57 kcal mol-1), which indicated the highest solubility, was optimized with the molar ratio of hydrogen bond donor (HBD)-hydrogen bond acceptor (HBA)-water (2:4:3) at a temperature of 60 °C. Hydrogen bonding networks of the NH-LTTMs, which led to the dissolution of biomass, were confirmed by the alteration in the peaks of the involved bonds and resonance signal to lower field through FTIR and 1H NMR spectra, respectively. The components evidenced in high-resolution mass spectra of extracted lignin showed its high potential to be valorized into useful fuels and chemicals.
    Matched MeSH terms: Temperature; Transition Temperature*
  2. Mustafa Hj. Abdullah, Ahmad Nazlim Yusoff
    The electrical resistivity of Mg0.6Zn0.4Fe2O4 ferrite was measured as a function of temperature in the range 300-630 K. Two anomalies are observed in the resistivity curves for measurements during heating up. These anomalies are identified as a magnetic anomaly at the Neel temperature, TN = 598 K, while the other one at TOt = 445 K is discussed as due to the contribution of conduction from the tetrahedral sites. The anomaly at Tot was reduced in the measurements during recooling, while the anomaly at TN was disappeared completely during recooling and second cycle. These effects are discussed as due to the increase of Fe2+ ions at the octahedral sites as a result of cation redistribution at higher temperatures. A relatively small anomaly at Tot still can be observed during the second run. This is possible if the Fe2+ ions have a preference to be relocated at the tetrahedral sites at lower temperatures.
    Kerintangan elektrik Mg0.6Zn0.4Fe2O4 ferit telah diukur sebagai fungsi suhu dalam julat 300 - 630 K. Dua anomali dapat dicerap pada lengkung kerintangan bagi pengukuran semasa pemanasan. Dua anomali tersebut dikenalpasti sebagai anomali magnet pada suhu Neel, TN = 598 K, manakala yang satu lagi pada Tot = 445 K dibincangkan sebagai berpunca daripada sumbangan kekonduksian pada tapak tetrahedron. Anomali pada Tot mengurang dalam pengukuran semasa penyejukan semula pada julat suhu yang sarna, manakala anomali pada TN terus lenyap dalam pengukuran semasa penyejukan semula dan juga semasa kitar kedua. Kesan ini dibincangkan sebagai disebabkan oleh peningkatan ion Fe2+ pada tapak oktahedron daripada proses taburan semula kation pada suhu tinggi. Anomali yang berkurang pada Tot masih boleh dicerap semasa pengukuran kitar kedua. Keadaan seperti ini adalah mungkin jika ion Fe2+ mempunyai kecenderongan untuk bertempat semula pada tapak tetrahedron apabila suhu menurun.
    Matched MeSH terms: Cold Temperature; Hot Temperature; Temperature
  3. Syazwani Mohd Zokri, Nur Syamilah Arifin, Muhammad Khairul Anuar Mohamed, Abdul Rahman Mohd Kasim, Mohd Zuki Salleh, Nurul Farahain Mohammad
    Sains Malaysiana, 2018;47:1607-1615.
    This paper delves into the problem of mixed convection boundary layer flow from a horizontal circular cylinder filled in
    a Jeffrey fluid with viscous dissipation effect. Both cases of cooled and heated cylinders are discussed. The governing
    equations which have been converted into a dimensionless form using the appropriate non-dimensional variables are solved
    numerically through the Keller-box method. A comparative study is performed and authentication of the present results
    with documented outcomes from formerly published works is excellently achieved. Tabular and graphical representations
    of the numerical results are executed for the specified distributions, considering the mixed convection parameter, Jeffrey
    fluid parameters and the Prandtl and Eckert numbers. Interestingly, boundary layer separation for mixed convection
    parameter happens for some positive (assisting flow) and negative (opposing flow) values. Strong assisting flow means
    the cylinder is heated, which causes the delay in boundary layer separation, whereas strong opposing flow means the
    cylinder is cooled, which conveys the separation point close to the lower stagnation point. Contradictory behaviours
    of both Jeffrey fluid parameters are observed over the velocity and temperature profiles together with the skin friction
    coefficient and Nusselt number. The increase of the Prandtl number leads to the decrement of the temperature profile,
    while the increase of the Eckert number results in the slight increment of the skin friction coefficient and decrement of
    the Nusselt number. Both velocity and temperature profiles of Eckert number show no effects at the lower stagnation
    point of the cylinder.
    Matched MeSH terms: Cold Temperature; Hot Temperature; Temperature
  4. Haibo Jiang, Zuguo Mo, Xiongbin Hou, Haijuan Wang
    Sains Malaysiana, 2017;46:2205-2213.
    The mechanical properties of fractured rock mass are largely dependent on the fracture structure under the coupling of freeze-thaw cycles and large temperature difference. Based on the traditional macroscopic continuum theory, the thermal and mechanical model and the corresponding theories ignore the material internal structure characteristics, which add difficulty in describing the mesoscopic thermal and mechanical behavior of the fractured rock mass among different phases. In order to uncover the inherent relationship and laws among the internal crack development, structural change and the physical and mechanical properties of rock under strong cold and frost weathering in cold area, typical granite and sandstone in cold region were analyzed in laboratory tests. The SEM scanning technology was introduced to record the microstructural change of rock samples subject to freeze-thaw cycles and large temperature difference. Association rules between the microstructure and the physical mechanical properties of rock mass were analyzed. The results indicated that, with the increase of the cyclic number, the macroscopic physical and mechanical indexes and the microscopic fracture index of granite and sandstone continuously and gradually deteriorate. The width of original micro crack continues to expand and extend and new local micro cracks are generated and continue to expand. The fracture area and width of the rock increase and the strength of the rock is continuously damaged. In particular, the strength and elastic modulus of granite decrease by 20.2% and 33.36%, respectively; the strength and elastic modulus of sandstone decrease by 33.4% and 36.43%, respectively.
    Matched MeSH terms: Body Temperature; Cold Temperature; Temperature
  5. Tao H, Hashim BM, Heddam S, Goliatt L, Tan ML, Sa'adi Z, et al.
    Environ Sci Pollut Res Int, 2023 Mar;30(11):30984-31034.
    PMID: 36441299 DOI: 10.1007/s11356-022-24153-8
    Urban areas are quickly established, and the overwhelming population pressure is triggering heat stress in the metropolitan cities. Climate change impact is the key aspect for maintaining the urban areas and building proper urban planning because spreading of the urban area destroyed the vegetated land and increased heat variation. Remote sensing-based on Landsat images are used for investigating the vegetation circumstances, thermal variation, urban expansion, and surface urban heat island or SUHI in the three megacities of Iraq like Baghdad, Erbil, and Basrah. Four satellite imageries are used aimed at land use and land cover (LULC) study from 1990 to 2020, which indicate the land transformation of those three major cities in Iraq. The average annually temperature is increased during  30 years like Baghdad (0.16 °C), Basrah (0.44 °C), and Erbil (0.32 °C). The built-up area is increased 147.1 km2 (Erbil), 217.86 km2 (Baghdad), and 294.43 km2 (Erbil), which indicated the SUHI affects the entire area of the three cities. The bare land is increased in Baghdad city, which indicated the local climatic condition and affected the livelihood. Basrah City is affected by anthropogenic activities and most areas of Basrah were converted into built-up land in the last 30 years. In Erbil, agricultural land (295.81 km2) is increased. The SUHI study results indicated the climate change effect in those three cities in Iraq. This study's results are more useful for planning, management, and sustainable development of urban areas.
    Matched MeSH terms: Hot Temperature*; Temperature
  6. Hamed MM, Salehie O, Nashwan MS, Shahid S
    Environ Sci Pollut Res Int, 2023 Mar;30(13):38063-38075.
    PMID: 36576621 DOI: 10.1007/s11356-022-24985-4
    Global warming has amplified the frequency of temperature extremes, especially in hot dry countries, which could have serious consequences for the natural and built environments. Egypt is one of the hot desert climate regions that are more susceptible to climate change and associated hazards. This study attempted to project the changes in temperature extremes for three Shared Socioeconomic Pathways (SSPs), namely, SSP1-2.6, SSP2-4.5, and SSP5-8.5 and two future periods (early future: 2020-2059 and late future: 2060-2099) by using daily maximum (Tmax) and minimum temperature (Tmin) of general circulation model (GCMs) of Coupled Model Inter-comparison Project phase 6 (CMIP6). The findings showed that most temperature extreme indices would increase especially by the end of the century. In the late future, the change in the mean Tmin (4.3 °C) was projected to be higher than the mean Tmax (3.7 °C). Annual maximum Tmax, temperature above 95th percentile of Tmax, and the number of hot days above 40 °C and 45 °C were projected to increase in the range 3.0‒5.4 °C, 1.5‒4.8 °C, 20‒95 days, and 10‒52 days, respectively. In contrast, the annual minimum of Tmin, temperature below the 5th percentile, and the annual percentage of cold nights were projected to change in the range of 2.95‒5.0 °C, 1.4‒3.6 °C, and - 0.1‒0.1%, respectively. In all the cases, the lowest changes would be for SSP1-2.6 in the early period and the greatest changes for SSP5-8.5 in the late period. The study indicates that the country is likely to experience a rise in hot extremes and a decline in cold extremes. Therefore, Egypt should take long-term adaptation plans to build social resiliency to rising hot extremes.
    Matched MeSH terms: Hot Temperature*; Temperature
  7. Kheimi M, K Salamah S, A Maddah H, Mustafa Al Bakri Abdullah M
    Chemosphere, 2023 Sep;335:139036.
    PMID: 37245592 DOI: 10.1016/j.chemosphere.2023.139036
    Considering the limitation of fossil fuel resources and their environmental effects, the use of renewable energies is increasing. In the current research, a combined cooling and power production (CCPP) system is investigated, the energy source of which is solar energy. Solar energy absorbs by solar flat plate collectors (SFPC). The system produces power with the help of an organic Rankine cycle (ORC). An ejector refrigeration cycle (ERC) system is considered to provide cooling capacity. The motive flow is supplied from the expander extraction in the ERC system. Various working fluids have been applied so far for the ORC-ERC cogeneration system. This research investigates the effect of using two working fluids R-11 and R-2545fa, and the zeotropic mixtures obtained by mixing these two fluids. A multiobjective optimization process is considered to select the appropriate working fluid. In the optimization design process, the goal is to minimize the total cost rate (TCR) and maximize the exergy efficiency of the system. The design variables are the quantity of SFPC, heat recovery vapor generator (HRVG) pressure, ejector motive flow pressure, evaporator pressure, condenser pressure, and entertainment ratio. Finally, it is observed that using zeotropic mixtures obtained from these two refrigerants has a better result than using pure refrigerants. Finally, it is observed that the best performance is achieved when R-11 and R245fa are mixed with a ratio of 80 to 20%, respectively and led to 8.5% improvement in exergy efficiency, while the increase in TCR is only 1.5%.
    Matched MeSH terms: Cold Temperature; Hot Temperature*
  8. Hai T, Alsubai S, Yahya RO, Gemeay E, Sharma K, Alqahtani A, et al.
    Chemosphere, 2023 Oct;338:139371.
    PMID: 37442387 DOI: 10.1016/j.chemosphere.2023.139371
    Combined cooling, heating and power (CCHP) is one of methods for enhancing the efficiency of the energy conversion systems. In this study a CCHP system consisting of a gas turbin (GT) as the topping cycle, and an organic Rankine cycle (ORC) associated with double-effect absorbtion chiller (DEACH) is decisioned as the bottoming cycle to recover the waste heat from GT exhaust gas. The considered CCHP system is investigated to maintain electricity, heating and cooling demand of a town. A parametric study is investigated and the effect decision variables on the performance indicators including exergy efficiency, total cost rate (TCR), cooling capacity, and ORC power generation is examined. Decision variables of the ORC system consist of HRVG pressure, and condenser pressure and the DEACH including evaporator pressure, condseser pressure, concentration of the concentrated solution, concentration of the weak solution, and solution mass flow rate. Finally a multi-objective optimization performed using Genetic Algorithm (GA) and the optimal design point is selected. It is observed at the optimum point the exergy efficiency, TCR, and sustainability index are 17.56%, 74.49 $/h, and 1.21, respectively.
    Matched MeSH terms: Cold Temperature*; Hot Temperature
  9. Barrett RJ, Lucas RH
    Soc Sci Med, 1994 Jan;38(2):383-93.
    PMID: 8140465
    Iban categories of hot and cold are examined in the context of humoral medical systems in southeast Asia. These categories are more than binary and oppositional: they are also contradictory and can only be understood in terms of their capacity for transformation in 'depth'. Analysis of the Iban epistemology of temperature sensation reveals the limitations of reductionist empirical approaches to hot and cold. Illness is apprehended, at one level, in terms of unusual conjunctions of opposite temperatures which signify a deeper disturbance in the relationship between body and soul, humans and spirits. Iban therapy redefines and relocates these categories in their proper place and at their appropriate level. It progresses from hot lay treatments to cool ritual treatments, yet cannot be accounted for within a limited framework of homeostatic balance. This paper develops an ethnographically grounded definition of humoralism which emphasizes non-reductive logic, cultural practice and transformation. The key element, transformation, is defined as a transition between categories and a shift in the level of interpretation which fundamentally alter the Iban experience of body and illness.
    Matched MeSH terms: Cold Temperature; Hot Temperature; Temperature*
  10. von Tunzelmann EW
    Matched MeSH terms: Temperature
  11. Lum CY, Ong LH, ÄŒepic M
    Sains Malaysiana, 2011;40:1123-1127.
    The transition of orthogonal smectic A (SmA) phase to the tilted phases, upon lowering the temperature, is explored with a discrete phenomenological model and the phase diagrams are presented. The results show that the transition of SmA to uniplanar structures can be affected by the effect of chirality. The areas showing the uniplanar phase in the phase diagrams diminish with the increase in effect of chirality.
    Matched MeSH terms: Temperature
  12. Mahdi RI, Gan WC, Abd Majid WH
    Sensors (Basel), 2014;14(10):19115-27.
    PMID: 25317763 DOI: 10.3390/s141019115
    Ferroelectric poly(vinylidene fluoride-trifluoroethylene) (P(VDF-TrFE)) copolymer 70/30 thin films are prepared by spin coating. The crystalline structure of these films is investigated by varying the annealing temperature from the ferroelectric phase to the paraelectric phase. A hot plate was used to produce a direct and an efficient annealing effect on the thin film. The dielectric, ferroelectric and pyroelectric properties of the P(VDF-TrFE) thin films are measured as a function of different annealing temperatures (80 to 140 °C). It was found that an annealing temperature of 100 °C (slightly above the Curie temperature, Tc) has induced a highly crystalline β phase with a rod-like crystal structure, as examined by X-ray. Such a crystal structure yields a high remanent polarization, Pr = 94 mC/m2, and pyroelectric constant, p = 24 μC/m2K. A higher annealing temperature exhibits an elongated needle-like crystal domain, resulting in a decrease in the crystalline structure and the functional electrical properties. This study revealed that highly crystalline P(VDF-TrFE) thin films could be induced at 100 °C by annealing the thin film with a simple and cheap method.
    Matched MeSH terms: Body Temperature; Temperature
  13. Hussanan A, Zuki Salleh M, Tahar RM, Khan I
    PLoS One, 2014;9(10):e108763.
    PMID: 25302782 DOI: 10.1371/journal.pone.0108763
    In this paper, the heat transfer effect on the unsteady boundary layer flow of a Casson fluid past an infinite oscillating vertical plate with Newtonian heating is investigated. The governing equations are transformed to a systems of linear partial differential equations using appropriate non-dimensional variables. The resulting equations are solved analytically by using the Laplace transform method and the expressions for velocity and temperature are obtained. They satisfy all imposed initial and boundary conditions and reduce to some well-known solutions for Newtonian fluids. Numerical results for velocity, temperature, skin friction and Nusselt number are shown in various graphs and discussed for embedded flow parameters. It is found that velocity decreases as Casson parameters increases and thermal boundary layer thickness increases with increasing Newtonian heating parameter.
    Matched MeSH terms: Hot Temperature; Temperature
  14. Salman SD, Kadhum AA, Takriff MS, Mohamad AB
    ScientificWorldJournal, 2013;2013:492762.
    PMID: 24078795 DOI: 10.1155/2013/492762
    Numerical investigation of the heat transfer and friction factor characteristics of a circular fitted with V-cut twisted tape (VCT) insert with twist ratio (y = 2.93) and different cut depths (w = 0.5, 1, and 1.5 cm) were studied for laminar flow using CFD package (FLUENT-6.3.26). The data obtained from plain tube were verified with the literature correlation to ensure the validation of simulation results. Classical twisted tape (CTT) with different twist ratios (y = 2.93, 3.91, 4.89) were also studied for comparison. The results show that the enhancement of heat transfer rate induced by the classical and V-cut twisted tape inserts increases with the Reynolds number and decreases with twist ratio. The results also revealed that the V-cut twisted tape with twist ratio y = 2.93 and cut depth w = 0.5 cm offered higher heat transfer rate with significant increases in friction factor than other tapes. In addition the results of V-cut twist tape compared with experimental and simulated data of right-left helical tape inserts (RLT), it is found that the V-cut twist tape offered better thermal contact between the surface and the fluid which ultimately leads to a high heat transfer coefficient. Consequently, 107% of maximum heat transfer was obtained by using this configuration.
    Matched MeSH terms: Hot Temperature*
  15. Goh CS, Tan HT, Lee KT
    Bioresour Technol, 2012 Apr;110:662-9.
    PMID: 22326327 DOI: 10.1016/j.biortech.2012.01.083
    The influence of reaction temperature (160-200°C), residence time (45-90min), and liquid-solid ratio (8-16v/w) on oil palm frond (OPF) pre-treated with hot compressed water (HCW) was evaluated using severity factors. Effect of the process parameters studied on pulps composition and digestibility were found to be complex. The results revealed that digestibility could not be predicted merely according to composition. Severity factor was correlated with compositional changes and digestibility with good R-squared values at varied liquid-solid ratios (8-16v/w), but not with overall glucose yield. HCW pretreatment significantly improved the overall glucose yield up to 83.72% with severity of 3.31 and liquid-solid ratio of 8.0 compared to untreated raw OPF which only recorded an overall glucose yield of 30.97%. HCW is therefore an effective method for pretreatment of OPF for glucose recovery.
    Matched MeSH terms: Hot Temperature*
  16. Iffa ED, Aziz AR, Malik AS
    Appl Opt, 2011 Feb 10;50(5):618-25.
    PMID: 21343981 DOI: 10.1364/AO.50.000618
    This paper utilizes the background oriented schlieren (BOS) technique to measure the velocity field of a variable density round jet. The density field of the jet is computed based on the light deflection created during the passage of light through the understudy jet. The deflection vector estimation was carried out using phase-based optical flow algorithms. The density field is further exploited to extract the axial and radial velocity vectors with the aid of continuity and energy equations. The experiment is conducted at six different jet-exit temperature values. Additional turbulence parameters, such as velocity variance and power spectral density of the vector field, are also computed. Finally, the measured velocity parameters are compared with the hot wire anemometer measurements and their correlation is displayed.
    Matched MeSH terms: Body Temperature; Temperature
  17. Jesudason CG
    PLoS One, 2016;11(1):e0145026.
    PMID: 26760507 DOI: 10.1371/journal.pone.0145026
    The Carnot cycle and its deduction of maximum conversion efficiency of heat inputted and outputted isothermally at different temperatures necessitated the construction of isothermal and adiabatic pathways within the cycle that were mechanically "reversible", leading eventually to the Kelvin-Clausius development of the entropy function S with differential dS = dq/T such that [symbol: see text]C dS = 0 where the heat absorption occurs at the isothermal paths of the elementary Carnot cycle. Another required condition is that the heat transfer processes take place infinitely slowly and "reversibly", implying that rates of transfer are not explicitly featured in the theory. The definition of 'heat' as that form of energy that is transferred as a result of a temperature difference suggests that the local mode of transfer of "heat" in the isothermal segments of the pathway implies a Fourier-like heat conduction mechanism which is apparently irreversible, leading to an increase in entropy of the combined reservoirs at either end of the conducting material, and which is deemed reversible mechanically. These paradoxes are circumvented here by first clarifying the terms used before modeling heat transfer as a thermodynamically reversible but mechanically irreversible process and applied to a one dimensional atomic lattice chain of interacting particles subjected to a temperature difference exemplifying Fourier heat conduction. The basis of a "recoverable trajectory" i.e. that which follows a zero entropy trajectory is identified. The Second Law is strictly maintained in this development. A corollary to this zero entropy trajectory is the generalization of the Zeroth law for steady state non-equilibrium systems with varying temperature, and thus to a statement about "equilibrium" in steady state non-thermostatic conditions. An energy transfer rate term is explicitly identified for each particle and agrees quantitatively (and independently) with the rate of heat absorbed at the reservoirs held at different temperatures and located at the two ends of the lattice chain in MD simulations, where all energy terms in the simulation refer to a single particle interacting with its neighbors. These results validate the theoretical model and provides the necessary boundary conditions (for instance with regard to temperature differentials and force fields) that thermodynamical variables must comply with to satisfy the conditions for a recoverable trajectory, and thus determines the solution of the differential and integral equations that are used to model these processes. These developments and results, if fully pursued would imply that not only can the Carnot cycle be viewed as describing a local process of energy-work conversion by a single interacting particle which feature rates of energy transfer and conversion not possible in the classical Carnot development, but that even irreversible local processes might be brought within the scope of this cycle, implying a unified treatment of thermodynamically (i) irreversible (ii) reversible (iii) isothermal and (iv) adiabatic processes by conflating the classically distinct concept of work and heat energy into a single particle interactional process. A resolution to the fundamental and long-standing conjecture of Benofy and Quay concerning the Fourier principle is one consequence of the analysis.
    Matched MeSH terms: Hot Temperature*
  18. Pazikadin AR, Rifai D, Ali K, Mamat NH, Khamsah N
    Sensors (Basel), 2020 Nov 25;20(23).
    PMID: 33255797 DOI: 10.3390/s20236744
    Photovoltaic (PV) systems need measurements of incident solar irradiance and PV surface temperature for performance analysis and monitoring purposes. Ground-based network sensor measurement is preferred in many near real-time operations such as forecasting and photovoltaic (PV) performance evaluation on the ground. Hence, this study proposed a Fuzzy compensation scheme for temperature and solar irradiance wireless sensor network (WSN) measurement on stand-alone solar photovoltaic (PV) system to improve the sensor measurement. The WSN installation through an Internet of Things (IoT) platform for solar irradiance and PV surface temperature measurement was fabricated. The simulation for the solar irradiance Fuzzy Logic compensation (SIFLC) scheme and Temperature Fuzzy Logic compensation (TFLC) scheme was conducted using Matlab/Simulink. The simulation result identified that the scheme was used to compensate for the error temperature and solar irradiance sensor measurements over a variation temperature and solar irradiance range from 20 to 60 °C and from zero up to 2000 W/m2. The experimental results show that the Fuzzy Logic compensation scheme can reduce the sensor measurement error up to 17% and 20% for solar irradiance and PV temperature measurement.
    Matched MeSH terms: Body Temperature; Temperature
  19. Chan WP, Veksha A, Lei J, Oh WD, Dou X, Giannis A, et al.
    J Environ Manage, 2019 Mar 15;234:65-74.
    PMID: 30616190 DOI: 10.1016/j.jenvman.2018.12.107
    A novel, cost-effective and real-time process monitoring and control system was developed to maintain stable operation of waste-to-energy gasification process. It comprised a feedback loop control that utilized the differential temperatures of the oxidation and reduction zones in the gasifier to determine the regional heat-flow (endothermic or exothermic), to assess the availability of oxidizing agent (for instance, air or O2) at the char bed and to calculate the fuel feeding rate. Based on the correlations developed, the air-to-fuel ratio or the equivalence air ratio (ER) for air gasification could be instantaneously adjusted to maintain stable operation of the gasifier. This study demonstrated a simplification of complex reaction dynamics in the gasification process to differential temperature profiling of the gasifier. The monitoring and control system was tested for more than 70 h of continuous operation in a downdraft fixed-bed gasifier with refuse-derived fuel (RDF) prepared from municipal solid wastes (MSW). With the system, fuel feeding rate could be adjusted accurately to stabilize the operating temperature and ER in the gasifier and generate syngas with consistent properties. Significant reductions in the fluctuations of temperature profiles at oxidation and reduction zones (from higher than 100 °C to lower than 50 °C), differential temperatures (from ±200 to ±50 °C) in gasifier and the flow rate (from 16 ± 6.5 to 12 ± 1.8 L/min), composition of main gas components, LHV (from 6.2 ± 3.1 to 5.7 ± 1.6 MJ/Nm3) and tar content (from 8.0 ± 9.7 to 7.5 ± 4.2 g/Nm3) of syngas were demonstrated. The developed gasifier monitoring and control system is adaptable to various types (updraft, downdraft, and fluidized-bed) and scales (lab, pilot, large scale) of gasifiers with different types of fuel.
    Matched MeSH terms: Hot Temperature; Temperature
  20. Zainazlan Md Zain1, Mohd Nasir Taib, Shahrizam M. S. Baki, Azni Zain Ahmed
    MyJurnal
    This paper examines the temperature profile of a building material and also a
    built space. The study directly examines the influence of solar radiation on
    building material and the heat it generated and diffuses into the built space.
    Two experiments are presented. The first look at a simple technique for
    evaluating heat performance of a building material, and the second evaluates
    the performance of a cross-ventilated built space with respect to solar radiation.
    Matched MeSH terms: Hot Temperature; Temperature
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links