Displaying publications 21 - 40 of 86 in total

Abstract:
Sort:
  1. Abdullah J, Saffie N, Sjasri FA, Husin A, Abdul-Rahman Z, Ismail A, et al.
    Braz J Microbiol, 2014;45(4):1385-91.
    PMID: 25763045
    An in-house loop-mediated isothermal amplification (LAMP) reaction was established and evaluated for sensitivity and specificity in detecting the presence of Salmonella Typhi (S. Typhi) isolates from Kelantan, Malaysia. Three sets of primers consisting of two outer and 4 inner were designed based on locus STBHUCCB_38510 of chaperone PapD of S. Typhi genes. The reaction was optimised using genomic DNA of S. Typhi ATCC7251 as the template. The products were visualised directly by colour changes of the reaction. Positive results were indicated by green fluorescence and negative by orange colour. The test was further evaluated for specificity, sensitivity and application on field samples. The results were compared with those obtained by gold standard culture method and Polymerase Chain Reaction (PCR). This method was highly specific and -10 times more sensitive in detecting S. Typhi compared to the optimised conventional polymerase chain reaction (PCR) method.
    Matched MeSH terms: Nucleic Acid Amplification Techniques/methods*
  2. Wee YC, Tan KL, Tan PC, Yap SF, Tan JAMA
    Med J Malaysia, 2005 Oct;60(4):447-53.
    PMID: 16570706
    Haemoglobin Bart's hydrops foetalis syndrome (--SEA/--SEA) is not compatible with life and contributes to a majority of the hydropic foetuses in the Malaysian Chinese alpha-thalassaemia carriers who possess the 2-alpha-gene deletion in cis (--SEA/alphaalpha). A duplex-PCR which simultaneously amplifies a normal 136 bp sequence between the psialpha-alpha2-globin genes and a 730 bp Southeast Asian deletion-specific sequence (--SEA) between the psialpha2-theta1-globin genes was established. The duplex-PCR which detects the --SEA deletion in both chromosomes serves as a rapid and cost-effective confirmatory test in the antenatal diagnosis of Haemoglobin Bart's hydrops foetalis syndrome in Malaysia. In addition, the duplex-PCR is simple to perform as both the normal and deletion-specific alpha-globin gene sequences are amplified in the same PCR reaction.
    Matched MeSH terms: Nucleic Acid Amplification Techniques
  3. Lai MY, Ooi CH, Lau YL
    Am J Trop Med Hyg, 2017 Nov;97(5):1597-1599.
    PMID: 28820700 DOI: 10.4269/ajtmh.17-0427
    In this study, we developed a recombinase polymerase amplification (RPA) assay for specific diagnosis of Plasmodium knowlesi. Genomic DNA was extracted from whole blood samples using a commercial kit. With incubation at 37°C, the samples were successfully amplified within 20 minutes. The end product of RPA was further examined by loading onto agarose gel and a specific band was observed with a size of 128 bp. The RPA assay exhibited high sensitivity with limits of detection down to one copy of the plasmid. From the specificity experiments, it was demonstrated that all P. knowlesi samples (N = 45) were positive while other Plasmodium spp. (N = 42) and negative samples (N = 6) were negative. Therefore, the RPA assay is a highly promising approach with the potential to be used in resource-limited settings. This assay can be further optimized for bedside and on field application.
    Matched MeSH terms: Nucleic Acid Amplification Techniques*
  4. Nurul Najian AB, Foo PC, Ismail N, Kim-Fatt L, Yean CY
    Mol Cell Probes, 2019 04;44:63-68.
    PMID: 30876924 DOI: 10.1016/j.mcp.2019.03.001
    This study highlighted the performance of the developed integrated loop-mediated isothermal amplification (LAMP) coupled with a colorimetric DNA-based magnetogenosensor. The biosensor operates through a DNA hybridization system in which a specific designed probe captures the target LAMP amplicons. We demonstrated the magnetogenosensor assay by detecting pathogenic Leptospira, which causes leptospirosis. The color change of the assay from brown to blue indicated a positive result, whereas a negative result was indicated by the assay maintaining its brown color. The DNA biosensor was able to detect DNA at a concentration as low as 200 fg/μl, which is equivalent to 80 genomes/reaction. The specificity of the biosensor assay was 100% when it was evaluated with 172 bacterial strains. An integrated LAMP and probe-specific magnetogenosensor was successfully developed, promising simple and rapid visual detection in clinical diagnostics and service as a point-of-care device.
    Matched MeSH terms: Nucleic Acid Amplification Techniques/methods*
  5. Yeoh CA, Chan CL, Chin CC, Tan WC
    Med J Malaysia, 2020 03;75(2):103-109.
    PMID: 32281589
    INTRODUCTION: Chlamydia trachomatis is one of the most common sexually transmitted diseases (STDs) globally. However, data on its prevalence and risk factors in Malaysia is still scarce.

    OBJECTIVE: We aimed to identify the prevalence and risk factors of genitourinary C.trachomatis infection among patients attending STD clinics in northern Peninsular Malaysia.

    METHODS: A hospital-based cross-sectional study was conducted in STD clinics of Hospital Pulau Pinang and Hospital Sultanah Bahiyah, Kedah from January to November 2014. Participants were individually interviewed using a structured data collection form followed by a physical examination and laboratory tests. Nucleic Acid Amplification Test (NAAT) was used to detect C.trachomatis infection. Analysis was carried out using SPSS Version 15.

    RESULTS: Eighty-three sexually active patients were enrolled, consisting of 51 males and 32 females. The median age was 28.0 years. In general, 32.5% patients were asymptomatic, the remaining presented with genital discharge (41.0%), genital warty lesion (25.3%), genital ulcer (13.3%), dysuria (13.3%), dyspareunia (2.4%), urine hesistancy (1.2%) and genital swelling (1.2%). The prevalence of genitourinary C.trachomatis infection was 21.7% in the study population; 17.6% in males and 28.1% in females. Among the infected females, 44.4% were pregnant. Of those infected 56.6% did not show any symptoms of genital infection, and 77.8% were aged between 18 and 30 years, of which most were females. Among newly diagnosed HIV patients, the prevalence was 14.3%. From multivariable logistic regression analysis, age under 28 years, being married and engagement in oral sex had significantly increased odds of C.trachomatis infection.

    CONCLUSIONS: C.trachomatis infection was common among patients attending STD clinics in northern Penisular Malaysia especially in the younger age groups. Majority of the infected patients were asymptomatic.

    Matched MeSH terms: Nucleic Acid Amplification Techniques
  6. Hamidah NH, Munirah AR, Hafiza A, Farisah AR, Shuhaila A, Norzilawati MN, et al.
    Malays J Pathol, 2014 Dec;36(3):163-8.
    PMID: 25500514 MyJurnal
    Prenatal diagnosis is essential in the new era of diagnosis and management of genetic diseases in obstetrics. Multiple ligation-dependent probe amplification (MLPA) is a recent technique for prenatal diagnosis for the relative quantification of 40 different nucleic acid sequences in one single reaction. We had utilized the MLPA technique in detecting aneuploidies in amniotic fluid samples from 25 pregnant women from the Obstetrics and Gynaecology Department UKMMC, versus the quantitative fluorescent polymerase chain reaction (QF-PCR) method. Conclusive results were obtained in 18 cases and all were concordant with that of the QF-PCR. All four cases of trisomies were correctly identified including one case with maternal cell contamination.
    Matched MeSH terms: Nucleic Acid Amplification Techniques/methods*
  7. Choi JR, Liu Z, Hu J, Tang R, Gong Y, Feng S, et al.
    Anal Chem, 2016 06 21;88(12):6254-64.
    PMID: 27012657 DOI: 10.1021/acs.analchem.6b00195
    In nucleic acid testing (NAT), gold nanoparticle (AuNP)-based lateral flow assays (LFAs) have received significant attention due to their cost-effectiveness, rapidity, and the ability to produce a simple colorimetric readout. However, the poor sensitivity of AuNP-based LFAs limits its widespread applications. Even though various efforts have been made to improve the assay sensitivity, most methods are inappropriate for integration into LFA for sample-to-answer NAT at the point-of-care (POC), usually due to the complicated fabrication processes or incompatible chemicals used. To address this, we propose a novel strategy of integrating a simple fluidic control strategy into LFA. The strategy involves incorporating a piece of paper-based shunt and a polydimethylsiloxane (PDMS) barrier to the strip to achieve optimum fluidic delays for LFA signal enhancement, resulting in 10-fold signal enhancement over unmodified LFA. The phenomena of fluidic delay were also evaluated by mathematical simulation, through which we found the movement of fluid throughout the shunt and the tortuosity effects in the presence of PDMS barrier, which significantly affect the detection sensitivity. To demonstrate the potential of integrating this strategy into a LFA with sample-in-answer-out capability, we further applied this strategy into our prototype sample-to-answer LFA to sensitively detect the Hepatitis B virus (HBV) in clinical blood samples. The proposed strategy offers great potential for highly sensitive detection of various targets for wide application in the near future.
    Matched MeSH terms: Nucleic Acid Amplification Techniques
  8. Ramlah Zainudin, Augustine Gawin, Dency Flenny
    MyJurnal
    Limnonectes kuhlii and Limnonectes leporinus are two of the Bornean fanged frogs (without advertisement call) which are widely distributed, thus thought to exhibit different evolutionary lineages and the existence of genetically cryptic species. Yet, the two species are still under study especially at the molecular level. Hence, cytochrome c oxidase I (COI) of mitochondrial gene was used to investigate suitable parameters for DNA amplification using the Polymerase Chain Reaction (PCR) method. Three PCR programmes (varied in the temperatures and period of each PCR step) were employed to identify the most efficient parameters in amplifying PCR products for both species. From the three programmes, Programme B (Initial denaturation: 96°C for 5 min; denaturation: 95°C for 45 sec; annealing: 48-53°C for 1 min 30 sec; extension: 72°C for 1 min 30 sec; final extension: 72°C for 10 min, 30 cycles) showed the highest percentage (53%) of optimal PCR products. The other two programmes showed non-specific products or “primer-dimers”. The results also suggest that the annealing temperature of 52°C, 0.025-0.05 units/µl of 1.5mM Taq polymerase, 0.04 mM of
    dNTPs mix and optimal concentrations of magnesium in 50 µl of reaction mixture were sufficient enough to amplify high quality PCR products for both species. However, using Programme B, the re-amplification of the PCR products yielded “primer-dimer”. In addition, a ‘Hot-Start’ PCR method was also applied and mostly yielded in an optimal PCR amplification. Nevertheless, further research on the second amplification of the two species should be conducted to determine the causes of the primer-dimer production.
    Matched MeSH terms: Nucleic Acid Amplification Techniques
  9. Abd Rahim MR, Kho SL, Kuppusamy UR, Tan JA
    Clin. Lab., 2015;61(9):1325-30.
    PMID: 26554253
    BACKGROUND: Beta-thalassemia is the most common genetic disorder in Malaysia. Confirmation of the β-globin gene mutations involved in thalassemia is usually carried out by molecular analysis of DNA extracted from leukocytes in whole blood. Molecular analysis is generally carried out when affected children are around 1 - 2 years as clinical symptoms are expressed during this period. Blood taking at this age can be distressing for the child. High yield and pure DNA extracted from non-invasive sampling methods can serve as alternative samples in molecular studies for genetic diseases especially in pediatric cases.

    METHODS: In this study, mouthwash, saliva, and buccal cytobrush samples were collected from β-thalassemia major patients who had previously been characterized using DNA extracted from peripheral blood. DNA was extracted from mouthwash, saliva, and buccal cytobrush samples using the conventional inexpensive phenol-chloroform method and was measured by spectrophotometry for yield and purity. Molecular characterization of β-globin gene mutations was carried out using the amplification refractory mutation system (ARMS).

    RESULTS: DNA extracted from mouthwash, saliva, and buccal cytobrush samples produced high concentration and pure DNA. The purified DNA was successfully amplified using ARMS. Results of the β-globin gene mutations using DNA from the three non-invasive samples were in 100% concordance with results from DNA extracted from peripheral blood.

    CONCLUSIONS: The conventional in-house developed methods for non-invasive sample collection and DNA extraction from these samples are effective and negate the use of more expensive commercial kits. In conclusion, DNA extracted from mouthwash, saliva, and buccal cytobrush samples provided sufficiently high amounts of pure DNA suitable for molecular analysis of β-thalassemia.

    Matched MeSH terms: Nucleic Acid Amplification Techniques
  10. Tay BY, Ahmad N, Hashim R, Mohamed Zahidi J, Thong KL, Koh XP, et al.
    BMC Infect Dis, 2015;15:220.
    PMID: 26033227 DOI: 10.1186/s12879-015-0958-0
    Brucellosis is one of the most common zoonotic diseases worldwide. It can cause acute febrile illness in human and is a major health problem. Studies in human brucellosis in Malaysia is limited and so far no genotyping studies has been done on Brucella isolates. The aim of the study was to determine the genetic diversity among Brucella species isolated from human brucellosis, obtained over a 6-year period (2009-2014).
    Matched MeSH terms: Nucleic Acid Amplification Techniques
  11. Al-Marzooq F, Mohd Yusof MY, Tay ST
    Biomed Res Int, 2014;2014:601630.
    PMID: 24860827 DOI: 10.1155/2014/601630
    Ninety-three Malaysian extended-spectrum β-lactamase (ESBL)-producing Klebsiella pneumoniae isolates were investigated for ciprofloxacin resistance. Two mismatch amplification mutation (MAMA) assays were developed and used to facilitate rapid detection of gyrA and parC mutations. The isolates were also screened for plasmid-mediated quinolone resistance (PMQR) genes including aac(6')-Ib-cr, qepA, and qnr. Ciprofloxacin resistance (MICs 4- ≥ 32  μ g/mL) was noted in 34 (37%) isolates, of which 33 isolates had multiple mutations either in gyrA alone (n = 1) or in both gyrA and parC regions (n = 32). aac(6')-Ib-cr was the most common PMQR gene detected in this study (n = 61), followed by qnrB and qnrS (n = 55 and 1, resp.). Low-level ciprofloxacin resistance (MICs 1-2  μ g/mL) was noted in 40 (43%) isolates carrying qnrB accompanied by either aac(6')-Ib-cr (n = 34) or a single gyrA 83 mutation (n = 6). Ciprofloxacin resistance was significantly associated with the presence of multiple mutations in gyrA and parC regions. While the isolates harbouring gyrA and/or parC alteration were distributed into 11 PFGE clusters, no specific clusters were associated with isolates carrying PMQR genes. The high prevalence of ciprofloxacin resistance amongst the Malaysian ESBL-producing K. pneumoniae isolates suggests the need for more effective infection control measures to limit the spread of these resistant organisms in the hospital.
    Matched MeSH terms: Nucleic Acid Amplification Techniques/methods
  12. Martín Ramírez A, Barón Argos L, Lanza Suárez M, Carmona Rubio C, Pérez-Ayala A, Hisam SR, et al.
    Pathog Glob Health, 2024 Feb;118(1):80-90.
    PMID: 37415348 DOI: 10.1080/20477724.2023.2232595
    Malaria is a parasitic disease distributed in tropical areas but with a high number of imported cases in non-endemic countries. The most specific and sensitive malaria diagnostic methods are PCR and LAMP. However, both require specific equipment, extraction procedures and a cold chain. This study aims to solve some limitations of LAMP method with the optimization and validation of six LAMP assays, genus and species-specific, using an easy and fast extraction method, the incorporation of a reaction control assay, two ways (Dual) of result reading and reagent lyophilization. The Dual-LAMP assays were validated against the Nested-Multiplex Malaria PCR. A conventional column and saline extraction methods, and the use of lyophilized reaction tubes were also assessed. A new reaction control Dual-LAMP-RC assay was designed. Dual-LAMP-Pspp assay showed no cross-reactivity with other parasites, repeatability and reproducibility of 100%, a significant correlation between parasite concentration and time to amplification and a LoD of 1.22 parasites/µl and 5.82 parasites/µl using column and saline extraction methods, respectively. Sensitivity and specificity of the six Dual-LAMP assays reach values of 100% or close to this, being lower for the Dual-LAMP-Pm. The Dual-LAMP-RC assay worked as expected. Lyophilized Dual-LAMP results were concordant with the reference method. Dual-LAMP malaria assays with the addition of a new reaction control LAMP assay and the use of a fast and easy saline extraction method, provided low limit of detection, no cross-reactivity, and good sensitivity and specificity. Furthermore, the reagent lyophilization and the dual result reading allow their use in most settings.
    Matched MeSH terms: Nucleic Acid Amplification Techniques/methods
  13. Lim KT, Teh CS, Thong KL
    Biomed Res Int, 2013;2013:895816.
    PMID: 23509796 DOI: 10.1155/2013/895816
    Staphylococcus aureus, including methicillin-resistant S. aureus (MRSA), is an important human pathogen that produces a variety of toxins and causes a wide range of infections, including soft-tissue infections, bacteremia, and staphylococcal food poisoning. A loop-mediated isothermal amplification (LAMP) assay targeting the arcC gene of S. aureus was developed and evaluated with 119 S. aureus and 25 non-S. aureus strains. The usefulness of the assay was compared with the PCR method that targets spa and arcC genes. The optimal temperature for the LAMP assay was 58.5°C with a detection limit of 2.5 ng/μL and 10(2) CFU/mL when compared to 12.5 ng/μL and 10(3) CFU/mL for PCR (spa and arcC). Both LAMP and PCR assays were 100% specific, 100% sensitive, 100% positive predictive value (PPV), and 100% negative predictive value (NPV). When tested on 30 spiked blood specimens (21 MRSA, eight non-S. aureus and one negative control), the performance of LAMP and PCR was comparable: 100% specific, 100% sensitive, 100% PPV, and 100% NPV. In conclusion, the LAMP assay was equally specific with a shorter detection time when compared to PCR in the identification of S. aureus. The LAMP assay is a promising alternative method for the rapid identification of S. aureus and could be used in resource-limited laboratories and fields.
    Matched MeSH terms: Nucleic Acid Amplification Techniques/methods*
  14. Teh CS, Chua KH, Lim YA, Lee SC, Thong KL
    ScientificWorldJournal, 2014;2014:457839.
    PMID: 24967435 DOI: 10.1155/2014/457839
    We have successfully developed a Loop-mediated isothermal amplification (LAMP) assay that could specifically detect generic Escherichia coli (E. coli). This assay was tested on 85 bacterial strains and successfully identified 54 E. coli strains (average threshold time, Tt = 21.26). The sensitivity of this assay was evaluated on serial dilutions of bacterial cultures and spiked faeces. The assay could detect 10(2) CFU/mL for bacterial culture with Tt = 33.30 while the detection limit for spiked faeces was 10(3) CFU/mL (Tt = 31.12). We have also detected 46 generic E. coli from 50 faecal samples obtained from indigenous individuals with 16% of the positive samples being verocytotoxin-producing E. coli (VTEC) positive. VT1/VT2 allele was present in one faecal sample while the ratio of VT1 to VT2 was 6 : 1. Overall, our study had demonstrated high risk of VTEC infection among the indigenous community and most of the asymptomatic infection occurred among those aged below 15 years. The role of asymptomatic human carriers as a source of dissemination should not be underestimated. Large scale screening of the VTEC infection among indigenous populations and the potential contamination sources will be possible and easy with the aid of this newly developed rapid and simple LAMP assay.
    Matched MeSH terms: Nucleic Acid Amplification Techniques/methods*
  15. Wong YP, Othman S, Lau YL, Radu S, Chee HY
    J Appl Microbiol, 2018 Mar;124(3):626-643.
    PMID: 29165905 DOI: 10.1111/jam.13647
    Loop-mediated isothermal amplification (LAMP) amplifies DNA with high specificity, efficiency and rapidity under isothermal conditions by using a DNA polymerase with high displacement strand activity and a set of specifically designed primers to amplify targeted DNA strands. Following its first discovery by Notomi et al. ( Nucleic Acids Res 28: E63), LAMP was further developed over the years which involved the combination of this technique with other molecular approaches, such as reverse transcription and multiplex amplification for the detection of infectious diseases caused by micro-organisms in humans, livestock and plants. In this review, available types of LAMP techniques will be discussed together with their applications in detection of various micro-organisms. Up to date, there are varieties of LAMP detection methods available including colorimetric and fluorescent detection, real-time monitoring using turbidity metre and detection using lateral flow device which will also be highlighted in this review. Apart from that, commercialization of LAMP technique had also been reported such as lyophilized form of LAMP reagents kit and LAMP primer sets for detection of pathogenic micro-organisms. On top of that, advantages and limitations of this molecular detection method are also described together with its future potential as a diagnostic method for infectious disease.
    Matched MeSH terms: Nucleic Acid Amplification Techniques/methods*
  16. Yon JLT, Htet NH, Naing C, Tung WS, Aung HH, Mak JW
    Malar J, 2022 Dec 22;21(1):391.
    PMID: 36550507 DOI: 10.1186/s12936-022-04419-9
    BACKGROUND: Due to relatively low malaria parasitaemia in pregnancy, an appropriate field test that can adequately detect infections in pregnant women presenting with illness or for malaria screening during antenatal care is crucially important. The objective was to evaluate the diagnostic accuracy of loop-mediated isothermal amplification (LAMP) for the detection of uncomplicated malaria in pregnancy.

    METHODS: This was a meta-analysis of diagnostic accuracy. Relevant studies that assessed the diagnostic performance of LAMP for the detection of malaria in pregnancy were searched in health-related electronic databases including PubMed, Ovid, and Google Scholar. The methodological quality of the studies included was evaluated using the QUADAS-2 tool.

    RESULTS: Of the 372 studies identified, eight studies involving 2999 pregnant women in five endemic countries that assessed the accuracy of LAMP were identified. With three types of PCR as reference tests, the pooled sensitivity of LAMP was 91% (95%CI 67-98%) and pooled specificity was 99% (95%CI 83-100%, 4 studies), and the negative likelihood ratio was 9% (2-40%). Caution is needed in the interpretation as there was substantial between-study heterogeneity (I2: 80%), and a low probability that a person without infection is tested negative. With microscopy as a reference, the pooled sensitivity of LAMP was 95% (95%CI 26-100%) and pooled specificity was 100% (95%CI 94-100%, 4 studies). There was a wide range of sensitivity and substantial between-study heterogeneity (I2: 83.5-98.4%). To investigate the source of heterogeneity, a meta-regression analysis was performed with covariates. Of these potential confounding factors, reference test (p: 0.03) and study design (p:0.03) had affected the diagnostic accuracy of LAMP in malaria in pregnancy. Overall, there was a low certainty of the evidence in accuracy estimates.

    CONCLUSION: The findings suggest that LAMP is more sensitive than traditional tests used at facilities, but the utility of detecting and treating these low-density infections is not well understood. Due to the limited number of studies with bias in their methodological quality, variation in the study design, and different types of reference tests further research is likely to change the estimate. Well-conceived large prospective studies with blinding of the index test results are recommenced.

    Matched MeSH terms: Nucleic Acid Amplification Techniques/methods
  17. Selvarajah D, Naing C, Htet NH, Mak JW
    Malar J, 2020 Jun 19;19(1):211.
    PMID: 32560728 DOI: 10.1186/s12936-020-03283-9
    BACKGROUND: The global malaria decline has stalled and only a few countries are pushing towards pre-elimination. The aim of the malaria elimination phase is interruption of local transmission of a specified malaria parasite in a defined geographical area. New and improved screening tools and strategies are required for detection and management of very low-density parasitaemia in the field. The objective of this study was to synthesize evidence on the diagnostic accuracy of loop-mediated isothermal amplification (LAMP) test for the detection of malaria parasites among people living in endemic areas.

    METHODS: This study adhered to the Preferred Reporting Items for Systematic Reviews and Meta-Analysis for Diagnostic Test Accuracy (PRISMA-DTA) guideline. Relevant studies in the health-related electronic databases were searched. According to the criteria set for this study, eligible studies were identified. The quality of included studies was evaluated with the use of a quality assessment checklist. A summary performance estimates such as pooled sensitivity and specificity were stratified by type of LAMP. Bivariate model for data analyses was applied. Summary receiver operating characteristics plots were created to display the results of individual studies in a receiver operating characteristics space. Meta-regression analysis was performed to investigate the sources of heterogeneity among individual studies.

    RESULTS: Twenty-seven studies across 17 endemic countries were identified. The vast majority of studies were with unclear risk of bias in the selection of index test. Overall, the pooled test performances were high for Pan LAMP (sensitivity: 0.95, 95% CI 0.91 to 0.97; specificity: 0.98, 95% CI 0.95 to 0.99), Plasmodium falciparum (Pf) LAMP (sensitivity: 0.96, 95% CI 0.94 to 0.98; specificity: 0.99, 95% CI 0.96 to 1.00) or for Plasmodium vivax (Pv) LAMP from 6 studies (sensitivity: 0.98, 95% CI 0.92 to 0.99; specificity: 0.99, 95% CI 0.72 to 1.00). The area under the curve for Pan LAMP (0.99, 95% CI 0.98-1.00), Pf LAMP (0.99, 95% CI 0.97-0.99) and Pv LAMP was (1.00, 95% CI 0.98-1.00) indicated that the diagnostic performance of these tests were within the excellent accuracy range. Meta-regression analysis showed that sample size had the greatest impact on test performance, among other factors.

    CONCLUSIONS: The current findings suggest that LAMP-based assays are appropriate for detecting low-level malaria parasite infections in the field and would become valuable tools for malaria control and elimination programmes. Future well-designed larger sample studies on LAMP assessment in passive and active malaria surveillances that use PCR as the reference standard and provide sufficient data to construct 2 × 2 diagnostic table are needed.

    Matched MeSH terms: Nucleic Acid Amplification Techniques/methods*
  18. Foo PC, Nurul Najian AB, Muhamad NA, Ahamad M, Mohamed M, Yean Yean C, et al.
    BMC Biotechnol, 2020 Jun 22;20(1):34.
    PMID: 32571286 DOI: 10.1186/s12896-020-00629-8
    BACKGROUND: This study reports the analytical sensitivity and specificity of a Loop-mediated isothermal amplification (LAMP) and compares its amplification performance with conventional PCR, nested PCR (nPCR) and real-time PCR (qPCR). All the assays demonstrated in this study were developed based on Serine-rich Entamoeba histolytica protein (SREHP) gene as study model.

    RESULTS: A set of SREHP gene specific LAMP primers were designed for the specific detection of Entamoeba histolytica. This set of primers recorded 100% specificity when it was evaluated against 3 medically important Entamoeba species and 75 other pathogenic microorganisms. These primers were later modified for conventional PCR, nPCR and qPCR applications. Besides, 3 different post-LAMP analyses including agarose gel electrophoresis, nucleic acid lateral flow immunoassay and calcein-manganese dye techniques were used to compare their limit of detection (LoD). One E. histolytica trophozoite was recorded as the LoD for all the 3 post-LAMP analysis methods when tested with E. histolytica DNA extracted from spiked stool samples. In contrast, none of the PCR method outperformed LAMP as both qPCR and nPCR recorded LoD of 100 trophozoites while the LoD of conventional PCR was 1000 trophozoites.

    CONCLUSIONS: The analytical sensitivity comparison among the conventional PCR, nPCR, qPCR and LAMP reveals that the LAMP outperformed the others in terms of LoD and amplification time. Hence, LAMP is a relevant alternative DNA-based amplification platform for sensitive and specific detection of pathogens.

    Matched MeSH terms: Nucleic Acid Amplification Techniques
  19. Lau YL, Lai MY, Fong MY, Jelip J, Mahmud R
    Am J Trop Med Hyg, 2016 Feb;94(2):336-339.
    PMID: 26598573 DOI: 10.4269/ajtmh.15-0569
    The lack of rapid, affordable, and accurate diagnostic tests represents the primary hurdle affecting malaria surveillance in resource- and expertise-limited areas. Loop-mediated isothermal amplification (LAMP) is a sensitive, rapid, and cheap diagnostic method. Five species-specific LAMP assays were developed based on 18S rRNA gene. Sensitivity and specificity of LAMP results were calculated as compared with microscopic examination and nested polymerase chain reaction. LAMP reactions were highly sensitive with the detection limit of one copy for Plasmodium vivax, Plasmodium falciparum, and Plasmodium malariae and 10 copies for Plasmodium knowlesi and Plasmodium ovale. LAMP positively detected all human malaria species in all positive samples (N = 134; sensitivity = 100%) within 35 minutes. All negative samples were not amplified by LAMP (N = 67; specificity = 100%). LAMP successfully detected two samples with very low parasitemia. LAMP may offer a rapid, simple, and reliable test for the diagnosis of malaria in areas where malaria is prevalent.
    Matched MeSH terms: Nucleic Acid Amplification Techniques
  20. Chua EW, Maggo S, Kennedy MA
    Methods Mol Biol, 2017;1620:65-74.
    PMID: 28540699 DOI: 10.1007/978-1-4939-7060-5_3
    Polymerase chain reaction (PCR) is an oft-used preparatory technique in amplifying specific DNA regions for downstream analysis. The size of an amplicon was initially limited by errors in nucleotide polymerization and template deterioration during thermal cycling. A variant of PCR, designated long-range PCR, was devised to counter these drawbacks and enable the amplification of large fragments exceeding a few kb. In this chapter we describe a protocol for long-range PCR, which we have adopted to obtain products of 6.6, 7.2, 13, and 20 kb from human genomic DNA samples.
    Matched MeSH terms: Nucleic Acid Amplification Techniques/methods*