Displaying publications 41 - 60 of 77 in total

Abstract:
Sort:
  1. Kabbashi NA, Atieh MA, Al-Mamun A, Mirghami ME, Alam MD, Yahya N
    J Environ Sci (China), 2009;21(4):539-44.
    PMID: 19634432
    The capability of carbon nanotubes (CNTs) to adsorb lead (Pb) in aqueous solution was investigated. Batch mode adsorption experiment was conducted to determine the effects of pH, agitation speed, CNTs dosage and contact time. The removal of Pb(II) reached maximum value 85% or 83% at pH 5 or 40 mg/L of CNTs, respectively. Higher correlation coefficients from Langmuir isotherm model indicates the strong adsorptions of Pb(II) on the surface of CNTs (adsorption capacity Xm = 102.04 mg/g). The results indicates that the highest percentage removal of Pb (96.03%) can be achieved at pH 5, 40 mg/L of CNTs, contact time 80 min, and agitation speed 50 r/min.
  2. Yahya N, Ebert MA, Bulsara M, House MJ, Kennedy A, Joseph DJ, et al.
    Radiother Oncol, 2015 Nov;117(2):277-82.
    PMID: 26476560 DOI: 10.1016/j.radonc.2015.10.003
    This study aimed to compare urinary dose-symptom correlates after external beam radiotherapy of the prostate using commonly utilised peak-symptom models to multiple-event and event-count models which account for repeated events.
  3. Singh SK, Yahya N, Misiran K, Masdar A, Nor NM, Yee LC
    Rev Bras Anestesiol, 2016 May-Jun;66(3):259-64.
    PMID: 26993410 DOI: 10.1016/j.bjan.2014.09.009
    Combined spinal-epidural (CSE) has become an increasingly popular alternative to traditional labour epidural due to its rapid onset and reliable analgesia provided. This was a prospective, convenient sampling study to determine the effects of CSE analgesia on labour outcome.
  4. Wan Ibadullah WH, Yahya N, Ghazali SS, Kamaruzaman E, Yong LC, Dan A, et al.
    Rev Bras Anestesiol, 2016 Jul-Aug;66(4):363-8.
    PMID: 27157205 DOI: 10.1016/j.bjan.2016.04.007
    BACKGROUND AND OBJECTIVE: This was a prospective, randomized clinical study to compare the success rate of nasogastric tube insertion by using GlideScope™ visualization versus direct MacIntosh laryngoscope assistance in anesthetized and intubated patients.
    METHODS: Ninety-six ASA I or II patients, aged 18-70 years were recruited and randomized into two groups using either technique. The time taken from insertion of the nasogastric tube from the nostril until the calculated length of tube had been inserted was recorded. The success rate of nasogastric tube insertion was evaluated in terms of successful insertion in the first attempt. Complications associated with the insertion techniques were recorded.
    RESULTS: The results showed success rates of 74.5% in the GlideScope™ Group as compared to 58.3% in the MacIntosh Group (p=0.10). For the failed attempts, the nasogastric tube was successfully inserted in all cases using rescue techniques. The duration taken in the first attempt for both techniques was not statistically significant; Group A was 17.2±9.3s as compared to Group B, with a duration of 18.9±13.0s (p=0.57). A total of 33 patients developed complications during insertion of the nasogastric tube, 39.4% in Group A and 60.6% in Group B (p=0.15). The most common complications, which occurred, were coiling, followed by bleeding and kinking.
    CONCLUSION: This study showed that using the GlideScope™ to facilitate nasogastric tube insertion was comparable to the use of the MacIntosh laryngoscope in terms of successful rate of insertion and complications.
    KEYWORDS: Complications; Complicações; Direct laryngoscope; Laringoscopia direta; Nasogastric tube; Sonda nasogástrica; Videolaringoscópio; Videolaryngoscope
  5. Yahya N, Ebert MA, Bulsara M, House MJ, Kennedy A, Joseph DJ, et al.
    Med Phys, 2016 May;43(5):2040.
    PMID: 27147316 DOI: 10.1118/1.4944738
    Given the paucity of available data concerning radiotherapy-induced urinary toxicity, it is important to ensure derivation of the most robust models with superior predictive performance. This work explores multiple statistical-learning strategies for prediction of urinary symptoms following external beam radiotherapy of the prostate.
  6. Yahya N, Ebert MA, Bulsara M, Haworth A, Kennedy A, Joseph DJ, et al.
    Radiother Oncol, 2015 Jul;116(1):112-8.
    PMID: 26163088 DOI: 10.1016/j.radonc.2015.06.011
    To identify dosimetry, clinical factors and medication intake impacting urinary symptoms after prostate radiotherapy.
  7. Voon NS, Lau FN, Zakaria R, Md Rani SA, Ismail F, Manan HA, et al.
    Cancer Radiother, 2021 Feb;25(1):62-71.
    PMID: 33414057 DOI: 10.1016/j.canrad.2020.07.008
    PURPOSE: Nasopharyngeal carcinoma (NPC) radiotherapy (RT) irradiates parts of the brain which may cause cerebral tissue changes. This study aimed to systematically review the brain microstructure changes using MRI-based measures, diffusion tensor imaging (DTI), diffusion kurtosis imaging (DKI) and voxel-based morphometry (VBM) and the impact of dose and latency following RT.

    METHODS: PubMed and Scopus databases were searched based on PRISMA guideline to determine studies focusing on changes following NPC RT.

    RESULTS: Eleven studies fulfilled the inclusion criteria. Microstructural changes occur most consistently in the temporal region. The changes were correlated with latency in seven studies; fractional anisotropy (FA) and gray matter (GM) volume remained low even after a longer period following RT and areas beyond irradiation site with reduced FA and GM measures. For dosage, only one study showed correlation, thus requiring further investigations.

    CONCLUSION: DTI, DKI and VBM may be used as a surveillance tool in detecting brain microstructural changes of NPC patients which correlates to latency and brain areas following RT.

  8. Yahya N, Akhtar MN, Nasir N, Shafie A, Jabeli MS, Koziol K
    J Nanosci Nanotechnol, 2012 Oct;12(10):8100-9.
    PMID: 23421185
    In seabed logging the magnitude of electromagnetic (EM) waves for the detection of a hydrocarbon reservoir in the marine environment is very important. Having a strong EM source for exploration target 4000 m below the sea floor is a very challenging task. A new carbon nanotubes (CNT) fibres/aluminium based EM transmitter is developed and NiZn ferrite as magnetic feeders was used in a scaled tank to evaluate the presence of oil. Resistive scaled tank experiments with a scale factor of 2000 were carried out. X-ray Diffraction (XRD), Raman Spectroscopy and Field Emission Scanning Electron Microscope (FESEM) were done to characterize the synthesized magnetic feeders. Single phase Ni0.76Mg0.04Zn0.2Fe2O4, obtained by the sol-gel method and sintered at 700 degrees C in air, has a [311] major peak. FESEM results show nanoparticles with average diameters of 17-45 nm. Samples which have a high Q-factor (approximately 50) was used as magnetic feeders for the EM transmitter. The magnitude of the EM waves of this new EM transmitter increases up to 400%. A curve fitting method using MATLAB software was done to evaluate the performance of the new EM transmitter. The correlation value with CNT fibres/aluminium-NiZnFe2O4 base transmitter shows a 152.5% increase of the magnetic field strength in the presence of oil. Modelling of the scale tank which replicates the marine environment was done using the Finite Element Method (FEM). In conclusion, FEM was able to delineate the presence of oil with greater magnitude of E-field (16.89%) and the B field (4.20%) due to the new EM transmitter.
  9. Yahya N, Al Habashi RM, Koziol K, Borkowski RD, Akhtar MN, Kashif M, et al.
    J Nanosci Nanotechnol, 2011 Mar;11(3):2652-6.
    PMID: 21449447
    Aluminum substituted yttrium iron garnet nano particles with compositional variation of Y(3.0-x) A1(x)Fe5O12, where x = 0.0, 0.5, 1.0, 1.5, 2.0, 2.5 and 3.0 were prepared using sol gel technique. The X-ray diffraction results showed that the best garnet phase appeared when the sintering temperature was 800 degrees C. Nano-crystalline particles with high purity and sizes ranging from 20 to 100 nm were obtained. It was found that the aluminum substitution had resulted in a sharp fall of the d-spacing when x = 2, which we speculated is due to the preference of the aluminum atoms to the smaller tetrahedron and octahedron sites instead of the much larger dodecahedron site. High resolution transmission electron microscope (HRTEM) and electron diffraction (ED) patterns showed single crystal nanoparticles were obtained from this method. The magnetic measurement gave moderate values of initial permeability; the highest value of 5.3 was shown by sample Y3Fe5O12 at more than 100 MHz which was attributed to the morphology of the microstructure which appeared to be homogeneous. This had resulted in an easy movement of domain walls. The substitution of aluminum for yttrium is speculated to cause a cubic to rhombodedral structural change and had weakened the super-exchange interactions thus a fall of real permeability was observed. This might have created a strain in the sub-lattices and had subsequently caused a shift of resonance frequencies to more than 1.8 GHz when x > 0.5.
  10. Nasir N, Yahya N, Kashif M, Daud H, Akhtar MN, Zaid HM, et al.
    J Nanosci Nanotechnol, 2011 Mar;11(3):2551-4.
    PMID: 21449424
    This is our initial response towards preparation of nano-inductors garnet for high operating frequencies strontium iron garnet (Sr3Fe5O12) denoted as SrIG and yttrium iron garnet (Y3Fe5O12) denoted as YIG. The garnet nano crystals were prepared by novel sol-gel technique. The phase and crystal structure of the prepared samples were identified by using X-ray diffraction analysis. SEM images were done to reveal the surface morphology of the samples. Raman spectra was taken for yttrium iron garnet (Y3Fe5O12). The magnetic properties of the samples namely initial permeability (micro), relative loss factor (RLF) and quality factor (Q-Factor) were done by using LCR meter. From the XRD profile, both of the Y3Fe5O12 and Sr3Fe5O12 samples showed single phase garnet and crystallization had completely occurred at 900 degrees C for the SrIG and 950 degrees C for the YIG samples. The YIG sample showed extremely low RLF value (0.0082) and high density 4.623 g/cm3. Interesting however is the high Q factor (20-60) shown by the Sr3Fe5O12 sample from 20-100 MHz. This high performance magnetic property is attributed to the homogenous and cubical-like microstructure. The YIG particles were used as magnetic feeder for EM transmitter. It was observed that YIG magnetic feeder with the EM transmitter gave 39% higher magnetic field than without YIG magnetic feeder.
  11. Yusof ZYM, Mohamed NH, Radzi Z, Yahya NA, Ramli AS, Abdul Kadir R
    Ann Dent, 2007;14(1):31-38.
    MyJurnal
    Background: The high prevalence and impacts of orofacial pain (OFP) have caused major sufferings to individuals and society. The purpose of the study was to investigate the problems and impacts of OFP among a group of Malaysian aborigines. The objectives were to determine (i) the prevalence, aetiology, duration, severity, types and persistence of OFP during the past 3 months preceding the study; (ii) its associated impact on daily performance; and (iii) the measures taken for pain relief.
    Methods: This is a cross sectional study carried out in Kuala Lipis, Pahang involving 6 villages of Orang Asli Bateq and Semai. Study sample was chosen using convenient sampling including adults aged 16 years and above. Participants were invited for an interview using structured questionnaire followed by clinical examination. Data analysis was carried out using SPSS ver12.
    Results: Response rate was low at 20% (n = 140). Over one-quarter (26.4%) of the sample experienced OFP in the previous 3 months. Toothache was found to be the main aetiology (83.3%) followed by gingival pain (18.9%), temporomandibular joint (10.8%) and facial pain (8.1%). Mean duration of pain was 9.8 days for toothache, 162.4 days for gingival pain, 7.3 days for TMJ and 5.7 days for facial pain. Of those who had OFP, over half rated the pain as moderate (37.8%) and severe (29.7%) and most of the pain was ‘intermittent’ in nature (81.1%). Over half (62.2%) admitted the pain had disappeared during the interview. In terms of pain relief, 56.8% of the sample used traditional medicine. The pain had impacted on the chewing ability (70.3%, p=0.01), ability to sleep at night (73.0%, p<0.001), levels of anxiety (70.3%), ability to perform daily chores (33.3%) and social life (35.1%) of the Orang Asli sample.
    Conclusion: This study suggests the prevalence of OFP was high among the Orang Asli sample, which imposed considerable physical and psychological impacts on daily life.
    Key words: orofacial pain; impacts; quality of life; Malaysian aborigines
  12. Yahya N, Ebert MA, Bulsara M, Kennedy A, Joseph DJ, Denham JW
    Radiother Oncol, 2016 08;120(2):339-45.
    PMID: 27370204 DOI: 10.1016/j.radonc.2016.05.010
    BACKGROUND AND PURPOSE: Most predictive models are not sufficiently validated for prospective use. We performed independent external validation of published predictive models for urinary dysfunctions following radiotherapy of the prostate.

    MATERIALS/METHODS: Multivariable models developed to predict atomised and generalised urinary symptoms, both acute and late, were considered for validation using a dataset representing 754 participants from the TROG 03.04-RADAR trial. Endpoints and features were harmonised to match the predictive models. The overall performance, calibration and discrimination were assessed.

    RESULTS: 14 models from four publications were validated. The discrimination of the predictive models in an independent external validation cohort, measured using the area under the receiver operating characteristic (ROC) curve, ranged from 0.473 to 0.695, generally lower than in internal validation. 4 models had ROC >0.6. Shrinkage was required for all predictive models' coefficients ranging from -0.309 (prediction probability was inverse to observed proportion) to 0.823. Predictive models which include baseline symptoms as a feature produced the highest discrimination. Two models produced a predicted probability of 0 and 1 for all patients.

    CONCLUSIONS: Predictive models vary in performance and transferability illustrating the need for improvements in model development and reporting. Several models showed reasonable potential but efforts should be increased to improve performance. Baseline symptoms should always be considered as potential features for predictive models.

  13. Yahya N, Sukiman NK, Suhaimi NA, Azmi NA, Manan HA
    PLoS One, 2019;14(3):e0213583.
    PMID: 30897166 DOI: 10.1371/journal.pone.0213583
    BACKGROUND: The accessibility to radiotherapy facilities may affect the willingness to undergo treatment. We sought to quantify the distance and travel time of Malaysian population to the closest radiotherapy centre and to estimate the megavoltage unit (MV)/million population based on the regions.

    MATERIALS & METHODS: Data for subdistricts in Malaysia and radiotherapy services were extracted from Department of Statistics Malaysia and Directory of Radiotherapy Centres (DIRAC). Data from DIRAC were validated by direct communication with centres. Locations of radiotherapy centres, distance and travel time to the nearest radiotherapy were estimated using web mapping service, Google Map.

    RESULTS: The average distance and travel time from Malaysian population to the closest radiotherapy centre were 82.5km and 83.4mins, respectively. The average distance and travel were not homogenous; East Malaysia (228.1km, 236.1mins), Central (14.4km, 20.1mins), East Coast (124.2km, 108.8mins), Northern (42.9km, 42.8mins) and Southern (36.0km, 39.8mins). The MV/million population for the country is 2.47, East Malaysia (1.76), Central (4.19), East Coast (0.54), Northern (2.40), Southern (2.36). About 25% of the population needs to travel >100 km to get to the closest radiotherapy facility.

    CONCLUSION: On average, Malaysians need to travel far and long to reach radiotherapy facilities. The accessibility to radiotherapy facilities is not equitable. The disparity may be reduced by adding centres in East Malaysia and the East Coast.

  14. Yahya N, Ebert MA, House MJ, Kennedy A, Matthews J, Joseph DJ, et al.
    Int J Radiat Oncol Biol Phys, 2017 02 01;97(2):420-426.
    PMID: 28068247 DOI: 10.1016/j.ijrobp.2016.10.024
    PURPOSE: We assessed the association of the spatial distribution of dose to the bladder surface, described using dose-surface maps, with the risk of urinary dysfunction.

    METHODS AND MATERIALS: The bladder dose-surface maps of 754 participants from the TROG 03.04-RADAR trial were generated from the volumetric data by virtually cutting the bladder at the sagittal slice, intersecting the bladder center-of-mass through to the bladder posterior and projecting the dose information on a 2-dimensional plane. Pixelwise dose comparisons were performed between patients with and without symptoms (dysuria, hematuria, incontinence, and an International Prostate Symptom Score increase of ≥10 [ΔIPSS10]). The results with and without permutation-based multiple-comparison adjustments are reported. The pixelwise multivariate analysis findings (peak-event model for dysuria, hematuria, and ΔIPSS10; event-count model for incontinence), with adjustments for clinical factors, are also reported.

    RESULTS: The associations of the spatially specific dose measures to urinary dysfunction were dependent on the presence of specific symptoms. The doses received by the anteroinferior and, to lesser extent, posterosuperior surface of the bladder had the strongest relationship with the incidence of dysuria, hematuria, and ΔIPSS10, both with and without adjustment for clinical factors. For the doses to the posteroinferior region corresponding to the area of the trigone, the only symptom with significance was incontinence.

    CONCLUSIONS: A spatially variable response of the bladder surface to the dose was found for symptoms of urinary dysfunction. Limiting the dose extending anteriorly might help reduce the risk of urinary dysfunction.

  15. Wan Mat WR, Yahya N, Izaham A, Abdul Rahman R, Abdul Manap N, Md Zain J
    Int J Risk Saf Med, 2014;26(2):57-60.
    PMID: 24902502 DOI: 10.3233/JRS-140611
    Acute pain service (APS) ensures provision of effective and safe postoperative pain relief. The following cases describe a potentially fatal error in managing patients who receive epidural analgesia postoperatively.
  16. Awais MA, Yusoff MZ, Khan DM, Yahya N, Kamel N, Ebrahim M
    Sensors (Basel), 2021 Sep 30;21(19).
    PMID: 34640888 DOI: 10.3390/s21196570
    Motor imagery (MI)-based brain-computer interfaces have gained much attention in the last few years. They provide the ability to control external devices, such as prosthetic arms and wheelchairs, by using brain activities. Several researchers have reported the inter-communication of multiple brain regions during motor tasks, thus making it difficult to isolate one or two brain regions in which motor activities take place. Therefore, a deeper understanding of the brain's neural patterns is important for BCI in order to provide more useful and insightful features. Thus, brain connectivity provides a promising approach to solving the stated shortcomings by considering inter-channel/region relationships during motor imagination. This study used effective connectivity in the brain in terms of the partial directed coherence (PDC) and directed transfer function (DTF) as intensively unconventional feature sets for motor imagery (MI) classification. MANOVA-based analysis was performed to identify statistically significant connectivity pairs. Furthermore, the study sought to predict MI patterns by using four classification algorithms-an SVM, KNN, decision tree, and probabilistic neural network. The study provides a comparative analysis of all of the classification methods using two-class MI data extracted from the PhysioNet EEG database. The proposed techniques based on a probabilistic neural network (PNN) as a classifier and PDC as a feature set outperformed the other classification and feature extraction techniques with a superior classification accuracy and a lower error rate. The research findings indicate that when the PDC was used as a feature set, the PNN attained the greatest overall average accuracy of 98.65%, whereas the same classifier was used to attain the greatest accuracy of 82.81% with the DTF. This study validates the activation of multiple brain regions during a motor task by achieving better classification outcomes through brain connectivity as compared to conventional features. Since the PDC outperformed the DTF as a feature set with its superior classification accuracy and low error rate, it has great potential for application in MI-based brain-computer interfaces.
  17. Singh SK, Yahya N, Misiran K, Masdar A, Nor NM, Yee LC
    Braz J Anesthesiol, 2016 May-Jun;66(3):259-64.
    PMID: 27108822 DOI: 10.1016/j.bjane.2014.09.006
    BACKGROUND AND OBJECTIVES: Combined spinal-epidural (CSE) has become an increasingly popular alternative to traditional labour epidural due to its rapid onset and reliable analgesia provided. This was a prospective, convenient sampling study to determine the effects of CSE analgesia on labour outcome.

    METHODS: One hundred and ten healthy primigravida parturients with a singleton pregnancy of ≥37 weeks gestation and in the active phase of labour were studied. They were enrolled to the CSE (n=55) or Non-CSE (n=55) group based on whether they consented to CSE analgesia. Non-CSE parturients were offered other methods of labour analgesia. The duration of the first and second stage of labour, rate of instrumental vaginal delivery and emergency cesarean section, and Apgar scores were compared.

    RESULTS: The mean duration of the first and second stage of labour was not significantly different between both groups. Instrumental delivery rates between the groups were not significantly different (CSE group, 11% versus Non-CSE group, 16%). The slightly higher incidence of cesarean section in the CSE group (16% versus 15% in the Non-CSE group) was not statistically significant. Neonatal outcome in terms of Apgar score of less than 7 at 1 and 5min was similar in both groups.

    CONCLUSION: There were no significant differences in the duration of labour, rate of instrumental vaginal delivery and emergency cesarean section, and neonatal outcome in parturients who received compared to those who did not receive CSE for labour analgesia.
  18. Wan Ibadullah WH, Yahya N, Ghazali SS, Kamaruzaman E, Yong LC, Dan A, et al.
    Braz J Anesthesiol, 2016 Jul-Aug;66(4):363-8.
    PMID: 27343785 DOI: 10.1016/j.bjane.2014.11.013
    BACKGROUND AND OBJECTIVE: This was a prospective, randomized clinical study to compare the success rate of nasogastric tube insertion by using GlideScope™ visualization versus direct MacIntosh laryngoscope assistance in anesthetized and intubated patients.

    METHODS: Ninety-six ASA I or II patients, aged 18-70 years were recruited and randomized into two groups using either technique. The time taken from insertion of the nasogastric tube from the nostril until the calculated length of tube had been inserted was recorded. The success rate of nasogastric tube insertion was evaluated in terms of successful insertion in the first attempt. Complications associated with the insertion techniques were recorded.

    RESULTS: The results showed success rates of 74.5% in the GlideScope™ Group as compared to 58.3% in the MacIntosh Group (p=0.10). For the failed attempts, the nasogastric tube was successfully inserted in all cases using rescue techniques. The duration taken in the first attempt for both techniques was not statistically significant; Group A was 17.2±9.3s as compared to Group B, with a duration of 18.9±13.0s (p=0.57). A total of 33 patients developed complications during insertion of the nasogastric tube, 39.4% in Group A and 60.6% in Group B (p=0.15). The most common complications, which occurred, were coiling, followed by bleeding and kinking.

    CONCLUSION: This study showed that using the GlideScope™ to facilitate nasogastric tube insertion was comparable to the use of the MacIntosh laryngoscope in terms of successful rate of insertion and complications.
  19. Nattabi HA, Sharif NM, Yahya N, Ahmad R, Mohamad M, Zaki FM, et al.
    Acad Radiol, 2017 Oct 18.
    PMID: 29054676 DOI: 10.1016/j.acra.2017.09.002
    RATIONALE AND OBJECTIVE: This study is a dedicated 2D-shear wave elastography (2D-SWE) review aimed at systematically eliciting up-to-date evidence of its clinical value in differential diagnosis of benign and malignant thyroid nodules.

    METHODS: PubMed, Web of Science, and Scopus databases were searched for studies assessing the diagnostic value of 2D-SWE for thyroid malignancy risk stratification published until December 2016. The retrieved titles and abstracts were screened and evaluated according to the predefined inclusion and exclusion criteria. Methodological quality of the studies was assessed using the Quality Assessment of Studies of Diagnostic Accuracy included in Systematic Review 2 (QUADAS-2) tool. Extracted 2D-SWE diagnostic performance data were meta-analyzed to assess the summary sensitivity, specificity, and area under the receiver operating characteristic curve.

    RESULTS: After stepwise review, 14 studies in which 2D-SWE was used to evaluate 2851 thyroid nodules (1092 malignant, 1759 benign) from 2139 patients were selected for the current study. Study quality on QUADAS-2 assessment was moderate to high. The summary sensitivity, specificity and area under the receiver operating characteristic curve of 2D-SWE for differential diagnosis of benign and malignant thyroid nodules were 0.66 (95% confidence interval [CI]: 0.64-0.69), 0.78 (CI: 0.76-0.80), and 0.851 (Q* = 0.85), respectively. The pooled diagnostic odds ratio, negative likelihood ratio, and positive likelihood ratio were 12.73 (CI: 8.80-18.43), 0.31 (CI: 0.22-0.44), and 3.87 (CI: 2.83-5.29), respectively.

    CONCLUSION: Diagnostic performance of quantitative 2D-SWE for malignancy risk stratification of thyroid nodules is suboptimal with mediocre sensitivity and specificity, contrary to earlier reports of excellence.

  20. Kuziel AW, Milowska KZ, Chau PL, Boncel S, Koziol KK, Yahya N, et al.
    Adv Mater, 2020 Aug;32(34):e2000608.
    PMID: 32672882 DOI: 10.1002/adma.202000608
    The fundamental colloidal properties of pristine graphene flakes remain incompletely understood, with conflicting reports about their chemical character, hindering potential applications that could exploit the extraordinary electronic, thermal, and mechanical properties of graphene. Here, the true amphipathic nature of pristine graphene flakes is demonstrated through wet-chemistry testing, optical microscopy, electron microscopy, and density functional theory, molecular dynamics, and Monte Carlo calculations, and it is shown how this fact paves the way for the formation of ultrastable water/oil emulsions. In contrast to commonly used graphene oxide flakes, pristine graphene flakes possess well-defined hydrophobic and hydrophilic regions: the basal plane and edges, respectively, the interplay of which allows small flakes to be utilized as stabilizers with an amphipathic strength that depends on the edge-to-surface ratio. The interactions between flakes can be also controlled by varying the oil-to-water ratio. In addition, it is predicted that graphene flakes can be efficiently used as a new-generation stabilizer that is active under high pressure, high temperature, and in saline solutions, greatly enhancing the efficiency and functionality of applications based on this material.
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links