DESIGN: In this phase III, double-blind, multicentre study, patients with endoscopically confirmed EO were randomised 1:1 to receive vonoprazan 20 mg or lansoprazole 30 mg, once daily for up to 8 weeks. The primary endpoint was EO healing rate at 8 weeks. The secondary endpoints were EO healing rates at 2 and 4 weeks. Safety endpoints included treatment-emergent adverse events (TEAEs).
RESULTS: In the vonoprazan (n=238) and lansoprazole (n=230) arms, 8-week EO healing rates were 92.4% and 91.3%, respectively (difference 1.1% (95% CI -3.822% to 6.087%)). The respective 2-week EO healing rates were 75.0% and 67.8% (difference 7.2% (95% CI -1.054% to 15.371%)), and the respective 4-week EO healing rates were 85.3% and 83.5% (difference 1.8% (95% CI -4.763% to 8.395%)). In patients with baseline Los Angeles classification grade C/D, 2-week, 4-week and 8-week EO healing rates were higher with vonoprazan versus lansoprazole (2 weeks: 62.2% vs 51.5%, difference 10.6% (95% CI -5.708% to 27.002%); 4 weeks: 73.3% vs 67.2%, difference 6.2% (95% CI -8.884 to 21.223); and 8 weeks: 84.0% vs 80.6%, difference 3.4% (95% CI -9.187% to 15.993%)). Overall, EO healing rates appeared higher with vonoprazan versus lansoprazole. TEAE rates were 38.1% and 36.6% in the vonoprazan and lansoprazole group, respectively.
CONCLUSION: Our findings demonstrate the non-inferior efficacy of vonoprazan versus lansoprazole in terms of EO healing rate at 8 weeks in this population. Safety outcomes were similar in the two treatment arms.
TRIAL REGISTRATION NUMBER: NCT02388724.
METHODS: Two-year post-discharge follow-up data were analyzed from 8757 ACS PCI patients from EPICOR Asia (218 centers, eight countries). Major adverse cardiovascular events (MACE; death, non-fatal myocardial infarction [MI], non-fatal ischemic stroke), PCI characteristics, and AMPs were recorded. For MACE, time - to - event was analyzed using Cox regression.
RESULTS: Primary PCI was performed in 62.0% of ST-segment elevation MI (STEMI), 38.7% of non-STEMI (NSTEMI), and 24.2% of unstable angina (UA) patients. At 12 months, 88.1% of patients were on dual antiplatelet therapy (DAPT), with no differences by index event. Most (61.5%) still received DAPT at 2 years. Two-year incidences of mortality, composite MACE, and bleeding were 3.6%, 6.2%, and 6.6%, respectively. Risk of death and MACE was increased with STEMI and NSTEMI vs. UA. Patients from East Asia showed lower mortality and more bleeding vs. Southeast Asia/India.
CONCLUSIONS: Many patients in EPICOR Asia underwent PCI and received DAPT up to 2 years post-discharge. These real-world findings improve our understanding of AMP impact on outcomes in Asian patients with ACS undergoing PCI.
OBJECTIVE: The purpose of this report was to describe the prespecified long-term safety objective of Micra at 12 months and electrical performance through 24 months.
METHODS: The Micra Transcatheter Pacing Study was a prospective single-arm study designed to assess the safety and efficacy of the Micra VVIR leadless/intracardiac pacemaker. Enrolled patients met class I or II guideline recommendations for de novo ventricular pacing. The long-term safety objective was freedom from a system- or procedure-related major complication at 12 months. A predefined historical control group of 2667 patients with transvenous pacemakers was used to compare major complication rates.
RESULTS: The long-term safety objective was achieved with a freedom from major complication rate of 96.0% at 12 months (95% confidence interval 94.2%-97.2%; P < .0001 vs performance goal). The risk of major complications for patients with Micra (N = 726) was 48% lower than that for patients with transvenous systems through 12 months postimplant (hazard ratio 0.52; 95% confidence interval 0.35-0.77; P = .001). Across subgroups of age, sex, and comorbidities, Micra reduced the risk of major complications compared to transvenous systems. Electrical performance was excellent through 24 months, with a projected battery longevity of 12.1 years.
CONCLUSION: Long-term performance of the Micra transcatheter pacemaker remains consistent with previously reported data. Few patients experienced major complications through 12 months of follow-up, and all patient subgroups benefited as compared to transvenous pacemaker historical control group.
OBJECTIVE: To summarize reasons for ICD or cardiac resynchronization therapy defibrillator implant refusal by patients at risk for sudden cardiac arrest (Improve SCA) in developing countries.
METHODS: Primary prevention (PP) and secondary prevention (SP) patients from countries where ICD use is low were enrolled. PP patients with additional risk factors (syncope, ejection fraction