Displaying publications 41 - 60 of 73 in total

Abstract:
Sort:
  1. Mohd Hussain RH, Afiqah WN, Abdul Ghani MK, Khan NA, Siddiqui R, Anuar TS
    Saudi J Biol Sci, 2021 Apr;28(4):2352-2359.
    PMID: 33911949 DOI: 10.1016/j.sjbs.2021.01.030
    The incidence of Acanthamoeba keratitis has been increasing since the previous decades, especially among contact lens users. This infection is majorly caused by the use of ineffective contact lens disinfecting solution. Thus, this study was conducted to evaluate the in vitro effects of multi-purpose disinfecting solutions (MPDS) against Acanthamoeba trophozoites and cysts. Acanthamoeba genotype T4 isolated from contact lens paraphernalia and an environmental strains were propagated for trophozoite or cyst-containing culture and adjusted in final concentration of 1 × 105 cells/ml. Amoebicidal and cysticidal assays were conducted by incubating trophozoites and cysts with OPTI-FREE® Express®, ReNu® Fresh™, Complete® Multi-Purpose Solution and AVIZOR Unica® Sensitive according to the manufacturer's minimum recommended disinfectant time (MMRDT) for up to 12 h at 30 ⁰C. Trypan blue hemocytometer-based microscopic counts determined amoebicidal and cysticidal effects. The viability of Acanthamoeba trophozoites and cysts was confirmed by re-inoculated them in the 1.5% non-nutrient agar plates. It was found that none of the MPDS showed amoebicidal and cysticidal effects during the MMRDT. However, OPTI-FREE® Express® demonstrated a significant differences in average cell reduction for both stages within MMRDT. When subjected to 12 h exposure, both OPTI-FREE® Express® and ReNu® Fresh™ led to significant reduction in the number of trophozoite and cyst cells. Notably, Complete® Multi-Purpose Solution and AVIZOR Unica® Sensitive did appreciably improve the solution effectiveness towards trophozoite cells when incubated for 12 h. All MPDS were largely ineffective, with 100% survival of all isolates at MMRDT, while OPTI-FREE® Express® showed limited amoebicidal activity against the contact lens paraphernalia isolate, however, it was more against the environmental strains after 12 h incubation time. The commercially available MPDS employed in this research offered minimal effectiveness against the protozoa despite the contact time. Improvement or development of new solution should consider the adjustment of the appropriate disinfectant concentration, adequate exposure time or the incorporation of novel chemical elements, which are effective against Acanthamoeba for accelerated disinfecting and more reduction of potential exposure of contact lens users to Acanthamoeba keratitis.
    Matched MeSH terms: Disinfection
  2. Das A, Barua A, Mohimin MA, Abedin J, Khandaker MU, Al-Mugren KS
    Healthcare (Basel), 2021 Apr 10;9(4).
    PMID: 33920290 DOI: 10.3390/healthcare9040445
    BACKGROUND: The use of a touchless automated hand sanitizer dispenser may play a key role to reduce contagious diseases. The key problem of the conventional ultrasonic and infra-red-based dispensers is their malfunctioning due to the interference of sunlight, vehicle sound, etc. when deployed in busy public places. To overcome such limitations, this study introduced a laser-based sensing device to dispense sanitizer in an automated touchless process.

    METHOD: The dispensing system is based on an Arduino circuit breadboard where an ATmega328p microcontroller was pre-installed. To sense the proximity, a light-dependent resistor (LDR) is used where the laser light is to be blocked after the placement of human hands, hence produced a sharp decrease in the LDR sensor value. Once the LDR sensor value exceeds the lower threshold, the pump is actuated by the microcontroller, and the sanitizer dispenses through the nozzle.

    RESULTS AND DISCUSSION: A novel design and subsequent fabrication of a low-cost, touchless, automated sanitizer dispenser to be used in public places, was demonstrated. The overall performance of the manufactured device was analyzed based on the cost and power consumption, and environmental factors by deploying it in busy public places as well as in indoor environment in major cities in Bangladesh, and found to be more efficient and cost-effective compared to other dispensers available in the market. A comprehensive discussion on this unique design compared to the conventional ultrasonic and infra-red based dispensers, is presented to show its suitability over the commercial ones. The guidelines of the World Health Organization are followed for the preparation of sanitizer liquid. A clear demonstration of the circuitry connections is presented herein, which facilitates the interested individual to manufacture a cost-effective dispenser device in a relatively short time and use it accordingly. Conclusion: This study reveals that the LDR-based automated hand sanitizer dispenser system is a novel concept, and it is cost-effective compared to the conventional ones. The presented device is expected to play a key role in contactless hand disinfection in public places, and reduce the spread of infectious diseases in society.

    Matched MeSH terms: Hand Disinfection
  3. FARAH EILYANA MOHAMED
    MyJurnal
    Solar photocatalysis is a green technology that takes advantage of sustainable solar energy for enhancing oxidation process of numerous harmful water contaminants. In this study, a custom solar driven zinc oxide (ZnO)-mediated photocatalytic system was developed and its efficiency to remove organic contaminants as well as to disinfect selected bacteria was investigated. Methylene blue (MB) dye was used as the model organic contaminant, while Escherichia coli(E.coli) was used as the model fecal coliform bacteria in contaminated water. A series of photodegradation experiments were conducted on water contaminated with either 10 mg/L of MB or ~1010CFU/ml of E.coli. The experiments were completed under sunlight irradiation in the presence of 1 g/L of nano ZnO photocatalyst for up to 6 hours. Using a solar thermal collector, the photoreactor operated in the temperature range of 25 to 50 oC. The findings revealed that the combination of solar thermal with solar photocatalysis usingZnO intensified the degradation of MB and disinfection of E.coli. 98.08% of MB dye and 99.99% of E.coliwere successfully removed from the water within the first 3 hours of treatment. Almost complete removal was eventually achieved after 6 hours of treatment. It is therefore suggested that ZnO-based solar photocatalytic system developed in this study is highly efficient at enhancing water decontamination process.
    Matched MeSH terms: Disinfection
  4. R.A. Al-Naggar, Al-Jashamy, K.
    MyJurnal
    Hand hygiene is the single, most critical measure for reducing the risk of transmitting organisms to patients and health care providers. To our knowledge, none of such study on Malaysian university student exists in the literature. Therefore, the objective was to explore the perceptions and barriers of hand's hygiene practice among university students. Methods: Focus group discussion conducted in January-2010 among 40 medical science students from Management and Science University (MSU). Simple random sampling was used, and the ethics were obtained from participants. The students were divided into five focus groups; the number of each group ranged between 8-10 members. The data obtained were classified into various categories, and the data was analyzed manually. Results: The majority of the participants mentioned that they frequently washed their hands using soap. Some of the participants washed the hands only with plain water. However, the majority of the participants mentioned that the laziness was their main barrier of frequent hand washing, followed by lack of nearby water supply and then the feeling that their hands are not dirty enough to be infected. The majority of the participants agreed that hand washing is clinically significant in reducing the spread of infectious diseases; some of them disagreed. The Majority of the participants knew the hand washing technique in the university. Conclusion: Medical science students still have some misconception and negative attitude towards hand hygiene practice. Multidisciplinary strategies needed to improve hand hygiene among students.
    Matched MeSH terms: Hand Disinfection
  5. S. Sulaiha S.A., Wee, Yun Ling, Lie, Joo Chin, Eow, Wei-Liang, Muhamad Faiz, S., Chien, Noris Fook Tan
    MyJurnal
    Background: Nosocomial infection is among the leading problem in many major hospitals resulting in soaring cost expenditure in managing its affect.Hand washing practice is a crucial preventive way to contain such mischief but many ignored its importance. This is perhaps due to lack of appropriate role modeling from senior practitioners.
    Subjects and methods: Our study examined the prevalence of hand washing practice among medical students from year 3 to 5 and compared it to their knowledge and level of awareness on its importance in clinical practice. 142 students were randomly observed during their clinical work in the wards on this practice and questionnaires were later distributed to 268 students from all semesters on their knowledge on the technique and awareness on its importance.
    Results: Out of 142, almost 80% washed their hands but only 41.6% performed effective hand washing. In contrary, 80 to 90% showed good level of knowledge and awareness as well as perception about its importance in clinical practice.
    Conclusions: The contradictory findings between the actual practice of hand washing and knowledge as well as awareness suggest that enforcement on the practice is necessary. This requires motivation and cooperation from all health alliances and higher authority in the health system. Remedial measures are much needed in order to contain high incidence of nosocomial infection in our local practice.
    Matched MeSH terms: Hand Disinfection
  6. Norhani Mohidin, Tee, Lee Fung
    MyJurnal
    This survey represents an initial examination of contact lens practice in Malaysia. It is based on a questionnaire that was sent to selected members of the Association of the Malaysian Optometrists to survey the prescribing habits of g contact lenses and care products. Questions included types of lenses prescribed, care systems frequently recommended and types of complications seen. Optometrists in Malaysia prescribed an average of 90 new pairs of contact lenses per year. Soft lenses made up 84% of the prescription followed by 14% of rigid gas permeable lenses and 1.5% of polymethymethacrylate lenses. Disposable/frequent replacement lenses accounted for 60% of the soft lenses prescribed. The most commonly prescribed disinfecting system was chemical disinfection. The most common complication seen during aftercare consultation was dry eye-related problems.
    Matched MeSH terms: Disinfection
  7. Mansor NA, Tay KS
    Sci Total Environ, 2020 Apr 20;714:136745.
    PMID: 31982754 DOI: 10.1016/j.scitotenv.2020.136745
    Chlorination is a common disinfection method in water treatment. This method can be converted into an advanced oxidation process by incorporating UV irradiation during water treatment. This study investigated the degradation of hydrochlorothiazide (HCTZ) by chlorination and UV/chlorination in water. HCTZ is a diuretic medication that has been frequently detected in wastewater. For chlorination, the second-order rate constant for the reaction between HCTZ with free available chlorine was found to increase with increasing pH from 5 to 8 due to the increase of the anionic HCTZ fraction. UV/chlorination was found to be more efficient in removing HCTZ as compared with chlorination due to the presence of reactive radical species such as hydroxyl radicals. For transformation by-products, chlorination was found to produce two by-products via chlorination and hydroxylation reactions that occurred at the aromatic ring of HCTZ. For UV/chlorination, an additional by-product formed through a radical reaction at the heterocyclic moiety of HCTZ was detected. Based on the Escherichia coli inhibition study, chlorination and UV/chlorination were found to increase the toxicity of the HCTZ solution. This result indicated that even UV/chlorination showed higher effectiveness in removing HCTZ; however, it also has the potential to generate toxic by-products and effluent.
    Matched MeSH terms: Disinfection
  8. Chum JD, Lim DJZ, Sheriff SO, Pulikkotil SJ, Suresh A, Davamani F
    Restor Dent Endod, 2019 Feb;44(1):e8.
    PMID: 30834230 DOI: 10.5395/rde.2019.44.e8
    Objectives: Irrigants are imperative in endodontic therapy for the elimination of pathogens from the infected root canal. The present study compared the antimicrobial efficacy of octenidine dihydrochloride (OCT) with chlorhexidine (CHX) and sodium hypochlorite (NaOCl) against Staphylococcus epidermidis (S. epidermidis) for root canal disinfection.

    Materials and Methods: The minimum inhibitory concentration (MIC) was obtained using serial dilution method. The agar diffusion method was then used to determine the zones of inhibition for each irrigant. Lastly, forty 6-mm dentin blocks were prepared from human mandibular premolars and inoculated with S. epidermidis. Samples were randomly divided into 4 groups of 10 blocks and irrigated for 3 minutes with saline (control), 2% CHX, 3% NaOCl, or 0.1% OCT. Dentin samples were then collected immediately for microbial analysis, including an analysis of colony-forming units (CFUs).

    Results: The MICs of each tested irrigant were 0.05% for CHX, 0.25% for NaOCl, and 0.0125% for OCT. All tested irrigants showed concentration-dependent increase in zones of inhibition, and 3% NaOCl showed the largest zone of inhibition amongst all tested irrigants (p < 0.05). There were no significant differences among the CFU measurements of 2% CHX, 3% NaOCl, and 0.1% OCT showing complete elimination of S. epidermidis in all samples.

    Conclusions: This study showed that OCT was comparable to or even more effective than CHX and NaOCl, demonstrating antimicrobial activity at low concentrations against S. epidermidis.

    Matched MeSH terms: Disinfection
  9. Ng IS, Ooi CW, Liu BL, Peng CT, Chiu CY, Chang YK
    Int J Biol Macromol, 2020 Jul 01;154:844-854.
    PMID: 32194127 DOI: 10.1016/j.ijbiomac.2020.03.127
    In this study, polyacrylonitrile (PAN) nanofiber membrane was prepared by an electrospinning technique. After alkaline hydrolysis, the ion-exchange nanofiber membrane (P-COOH) was grafted with chitosan molecules to form a chitosan-modified nanofiber membrane (P-COOH-CS). Poly(hexamethylene biguanide) (PHMB) was then covalently immobilized on P-COOH and P-COOH-CS to form P-COOH-PHMB and P-COOH-CS-PHMB, respectively. The nanofiber membranes were subjected to various surface analyses as well as to the evaluations of antibacterial activity against Escherichia coli. The optimal modification conditions for P-COOH-CS-PHMB were attained by water-soluble chitosan at 50 kDa of molecular weight, coupling pH at 7, and 0.05% (w/w) of PHMB. Within 10 min of treatment, the antibacterial rate was close to 100%. Under the similar conditions of antibacterial treatment, the P-COOH-CS-PHMB exhibited a better antibacterial efficacy than the P-COOH-PHMB. When the number of bacterial cells was increased by 2000 folds, both types of nanofiber membranes still maintained the antibacterial rate close to 100%. After five cycles of repeated antibacterial treatment, the antibacterial efficacy of P-COOH-PHMB was 96%, which was higher than that of P-COOH-CS-PHMB (83%). The experimental results revealed that the PHMB-modified nanofiber membranes can be suitably applied in water treatment such as water disinfection and biofouling control.
    Matched MeSH terms: Disinfection
  10. Siah KTH, Rahman MM, Ong AML, Soh AYS, Lee YY, Xiao Y, et al.
    J Neurogastroenterol Motil, 2020 07 30;26(3):299-310.
    PMID: 32606253 DOI: 10.5056/jnm20107
    During the Coronavirus Disease 2019 (COVID-19) pandemic, practices of gastrointestinal procedures within the digestive tract require special precautions due to the risk of contraction of severe acute respiratoy syndrome coronavirus-2 (SARS-CoV-2) infection. Many procedures in the gastrointestinal motility laboratory may be considered moderate to high-risk for viral transmission. Healthcare staff working in gastrointestinal motility laboratories are frequently exposed to splashes, air droplets, mucus, or saliva during the procedures. Moreover, some are aerosol-generating and thus have a high risk of viral transmission. There are multiple guidelines on the practices of gastrointestinal endoscopy during this pandemic. However, such guidelines are still lacking and urgently needed for the practice of gastrointestinal motility laboratories. Hence, the Asian Neurogastroenterology and Motility Association had organized a group of gastrointestinal motility experts and infectious disease specialists to produce a position statement paper based-on current available evidence and consensus opinion with aims to provide a clear guidance on the practices of gastrointestinal motility laboratories during the COVID-19 pandemic. This guideline covers a wide range of topics on gastrointestinal motility activities from scheduling a motility test, the precautions at different steps of the procedure to disinfection for the safety and well-being of the patients and the healthcare workers. These practices may vary in different countries depending on the stages of the pandemic, local or institutional policy, and the availability of healthcare resources. This guideline is useful when the transmission rate of SARS-CoV-2 is high. It may change rapidly depending on the situation of the epidemic and when new evidence becomes available.
    Matched MeSH terms: Disinfection
  11. Fernando WJ, Othman R
    Math Biosci, 2006 Feb;199(2):175-87.
    PMID: 16387333
    Disinfectants are generally used to inactivate microorganisms in solutions. The process of inactivation involves the disinfectant in the liquid diffusing towards the bacteria sites and thereafter reacting with bacteria at rates determined by the respective reaction rates. Such processes have demonstrated an initial lag phase followed by an active depletion phase of bacteria. This paper attempts to study the importance of the combined effects of diffusion of the disinfectant through the outer membrane of the bacteria and transport through the associated concentration boundary layers (CBLs) during the initial lag phase. Mathematical equations are developed correlating the initial concentration of the disinfectant with time required for reaching a critical concentration (C*) at the inner side of the membrane of the cell based on diffusion of disinfectant through the outer membranes of the bacteria and the formation of concentration boundary layers on both sides of the membranes. Experimental data of the lag phases of inactivation already available in the literature for inactivation of Bacillus subtilis spores with ozone and monochloramine are tested with the equations. The results seem to be in good agreement with the theoretical equations indicating the importance of diffusion process across the outer cell membranes and the resulting CBL's during the lag phase of disinfection.
    Matched MeSH terms: Disinfection/methods
  12. Chan L, Yasmin AH, Ngeow YF, Ong GS
    Med J Malaysia, 1994 Mar;49(1):62-7.
    PMID: 8057993
    A closed enteral delivery system consisting of a cardboard tetrapack containing the sterile ready-to-use liquid feed and an independent sterile administration set, has been devised. We found bacterial contamination within 24 hours in this system in patients on ventilatory support in intensive care. This emphasises the need for meticulous care in handling enteral feeding systems to prevent environmental contamination.
    Matched MeSH terms: Hand Disinfection/methods
  13. Ng BJ, Musyaffa MK, Er CC, Packiam KAR, Lee WPC, Tan LL, et al.
    Chemistry, 2021 Feb 10;27(9):3085-3090.
    PMID: 33263935 DOI: 10.1002/chem.202004238
    Universal access to clean water has been a global ambition over the years. Photocatalytic water disinfection through advanced oxidation processes has been regarded as one of the promising methods for breaking down microbials. The forefront of this research focuses on the application of metal-free photocatalysts for disinfection to prevent secondary pollution. Graphitic carbon nitride (g-C3 N4 ) has achieved instant attention as a metal-free and visible-light-responsive photocatalyst for various energy and environmental applications. However, the photocatalytic efficiency of g-C3 N4 is still affected by its rapid charge recombination and sluggish electron-transfer kinetics. In this contribution, two-dimensionally protonated g-C3 N4 was employed as metal-free photocatalyst for water treatment and demonstrated 100 % of Escherichia coli within 4 h under irradiation with a 23 W light bulb. The introduction of protonation can modulate the surface charge of g-C3 N4 ; this enhances its conductivity and provides a "highway" for the delocalization of electrons. This work highlights the potential of conjugated polymers in antibacterial application.
    Matched MeSH terms: Disinfection/methods*
  14. Wu XH, Liew YK, Mai CW, Then YY
    Int J Mol Sci, 2021 Mar 24;22(7).
    PMID: 33805207 DOI: 10.3390/ijms22073341
    Medical devices are indispensable in the healthcare setting, ranging from diagnostic tools to therapeutic instruments, and even supporting equipment. However, these medical devices may be associated with life-threatening complications when exposed to blood. To date, medical device-related infections have been a major drawback causing high mortality. Device-induced hemolysis, albeit often neglected, results in negative impacts, including thrombotic events. Various strategies have been approached to overcome these issues, but the outcomes are yet to be considered as successful. Recently, superhydrophobic materials or coatings have been brought to attention in various fields. Superhydrophobic surfaces are proposed to be ideal blood-compatible biomaterials attributed to their beneficial characteristics. Reports have substantiated the blood repellence of a superhydrophobic surface, which helps to prevent damage on blood cells upon cell-surface interaction, thereby alleviating subsequent complications. The anti-biofouling effect of superhydrophobic surfaces is also desired in medical devices as it resists the adhesion of organic substances, such as blood cells and microorganisms. In this review, we will focus on the discussion about the potential contribution of superhydrophobic surfaces on enhancing the hemocompatibility of blood-contacting medical devices.
    Matched MeSH terms: Disinfection/methods*
  15. Khalit WNAW, Tay KS
    Ecotoxicol Environ Saf, 2017 Nov;145:214-220.
    PMID: 28738204 DOI: 10.1016/j.ecoenv.2017.07.020
    Unmetabolized pharmaceuticals often enter the water treatment plants and exposed to various treatment processes. Among these water treatment processes, disinfection is a process which involves the application of chemical oxidation to remove pathogen. Untreated pharmaceuticals from primary and secondary treatment have the potential to be exposed to the chemical oxidation process during disinfection. This study investigated the kinetics and mechanism of the degradation of sotalol during chlorination process. Chlorination with hypochlorous acid (HOCl) as main reactive oxidant has been known as one of the most commonly used disinfection methods. The second order rate constant for the reaction between sotalol and free available chlorine (FAC) was found to decrease from 60.1 to 39.1M-1min-1 when the pH was increased from 6 to 8. This result was mainly attributed by the decreased of HOCl concentration with increasing pH. In the real water samples, the presence of the higher amount of organic content was found to reduce the efficiency of chlorination in the removal of sotalol. This result showed that sotalol competes with natural organic matter to react with HOCl during chlorination. After 24h of FAC exposure, sotalol was found to produce three stable transformation by-products. These by-products are mainly chlorinated compounds. According to the acute and chronic toxicity calculated using ECOSAR computer program, the transformation by-products are more harmful than sotalol.
    Matched MeSH terms: Disinfection*
  16. Abjani F, Khan NA, Yousuf FA, Siddiqui R
    Cont Lens Anterior Eye, 2016 Jun;39(3):239-43.
    PMID: 26675112 DOI: 10.1016/j.clae.2015.11.004
    Acanthamoeba cysts are highly resistant to contact lens disinfecting solutions. Acanthamoeba cyst wall is partially made of 1,4 β-glucan (i.e., cellulose) and other complex polysaccharides making it a hardy shell that protects the resident amoeba. Here, we hypothesize that targeting the cyst wall structure in addition to antiamoebic compound would improve the efficacy of marketed contact lens disinfecting solutions. Using chlorhexidine as an antiamoebic compound and cellulase enzyme to disrupt cyst wall structure, the findings revealed that combination of both agents abolished viability of Acanthamoeba castellanii cysts and trophozoites. When tested alone, none of the agents nor contact lens disinfecting solutions completely destroyed A. castellanii cysts and trophozoites. The absence of cyst wall-degrading enzymes in marketed contact lens disinfecting solutions render them ineffective against Acanthamoeba cysts. It is concluded that the addition of cyst wall degrading molecules in contact lens disinfecting solutions will enhance their efficacy in decreasing the incidence of Acanthamoeba effectively.
    Matched MeSH terms: Disinfection/methods
  17. Veerachamy S, Yarlagadda T, Manivasagam G, Yarlagadda PK
    Proc Inst Mech Eng H, 2014 Oct;228(10):1083-99.
    PMID: 25406229 DOI: 10.1177/0954411914556137
    Biofilms are a complex group of microbial cells that adhere to the exopolysaccharide matrix present on the surface of medical devices. Biofilm-associated infections in the medical devices pose a serious problem to the public health and adversely affect the function of the device. Medical implants used in oral and orthopedic surgery are fabricated using alloys such as stainless steel and titanium. The biological behavior, such as osseointegration and its antibacterial activity, essentially depends on both the chemical composition and the morphology of the surface of the device. Surface treatment of medical implants by various physical and chemical techniques are attempted in order to improve their surface properties so as to facilitate bio-integration and prevent bacterial adhesion. The potential source of infection of the surrounding tissue and antimicrobial strategies are from bacteria adherent to or in a biofilm on the implant which should prevent both biofilm formation and tissue colonization. This article provides an overview of bacterial biofilm formation and methods adopted for the inhibition of bacterial adhesion on medical implants.
    Matched MeSH terms: Disinfection/methods*
  18. Siddiqui R, Aqeel Y, Khan NA
    Cont Lens Anterior Eye, 2016 Oct;39(5):389-93.
    PMID: 27133448 DOI: 10.1016/j.clae.2016.04.004
    Acanthamoeba castellanii is the causative agent of blinding keratitis. Though reported in non-contact lens wearers, it is most frequently associated with improper use of contact lens. For contact lens wearers, amoebae attachment to the lens is a critical first step, followed by amoebae binding to the corneal epithelial cells during extended lens wear. Acanthamoeba attachment to surfaces (biological or inert) and migration is an active process and occurs during the trophozoite stage. Thus retaining amoebae in the cyst stage (dormant form) offers an added preventative measure in impeding parasite traversal from the contact lens onto the cornea. Here, we showed that as low as 3% DMSO, abolished A. castellanii excystation. Based on the findings, it is proposed that DMSO should be included in the contact lens disinfectants as an added preventative strategy against contracting Acanthamoeba keratitis.
    Matched MeSH terms: Disinfection/methods
  19. Luddin N, Ahmed HM
    J Conserv Dent, 2013 Jan;16(1):9-16.
    PMID: 23349569 DOI: 10.4103/0972-0707.105291
    Complete debridement and disinfection of the root canal system are fundamental requirements for successful endodontic treatment. Despite the morphological challenges of the internal root anatomy, root canal irrigants play an important role in the optimization of the root canal preparation, which is essentially a chemo-mechanical procedure. Enterococcus faecalis is one of the most resistant microorganisms that dominants the microbial ecosystem of persistent periradicular lesions in retreatment cases. For that reason, many in vitro and in vivo studies evaluated and compared the antibacterial activity of sodium hypochlorite and chlorhexidine at varying concentrations using different experimental models against this microorganism. However, many controversies with regard to the ideal irrigant and concentration do in fact exist. Hence, this review aims to discuss the antibacterial activity of these two main root canal irrigants against Enterococcus faecalis using the agar diffusion and direct contact methods and the possible modulating factors responsible for inconsistent findings among different studies. In addition, the disinfection potential of both chemical agents on gutta percha and Resilon cones are also discussed. The source of this review was conducted through an electronic literature search using PubMed database from December 1997 until December 2011, which analyze the related laboratory investigations of both irrigants, published in major endodontic journals.
    Matched MeSH terms: Disinfection
  20. Ramli MR, Sulaiman NM, Mohd MA, Rabuni MF
    Water Sci Technol, 2015;72(9):1611-20.
    PMID: 26524453 DOI: 10.2166/wst.2015.367
    The effectiveness of combined nanofiltration and disinfection processes was studied by comparing the pre-disinfection and post-disinfection when in combination with nanofiltration. Four types of sulfonamide (sulfanilamide, sulfadiazine, sulfamethoxazole, and sulfadimethoxine) were chosen as substrates, with sodium hypochlorite as a disinfectant. A laboratory-scale nanofiltration system was used to conduct the following sets of experiment: (1) a pre-chlorination system, where the free active chlorine (FAC) was added to the membrane influent; and (2), a post-chlorination system, where the FAC was added to the membrane effluent. Overall, the pre-disinfection nanofiltration system showed higher sulfonamide removal efficiency compared to the post-chlorination nanofiltration system (>99.5% versus >89.5%). In the case of limited FAC ([FAC]0: [sulfonamide]0≤1), the removal efficiency for the post-chlorination nanofiltration system was higher, due to the prior nanofiltration process that could remove 12.5% to 80% of sulfonamide. The flux of the treated feed system was considerably higher than in the untreated feed system; however, the membrane was observed to be slightly damaged due to residual chlorine attack.
    Matched MeSH terms: Disinfection
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links