Displaying publications 41 - 60 of 546 in total

Abstract:
Sort:
  1. Hay JX, Wu TY, Juan JC, Md Jahim J
    Environ Sci Pollut Res Int, 2017 Apr;24(11):10354-10363.
    PMID: 28281053 DOI: 10.1007/s11356-017-8557-9
    Although a significant amount of brewery wastewater (BW) is generated during beer production, the nutrients in the BW could be reused as a potential bio-resource for biohydrogen production. Therefore, improvements in photofermentative biohydrogen production due to a combination of BW and pulp and paper mill effluent (PPME) as a mixed production medium were investigated comprehensively in this study. The experimental results showed that both the biohydrogen yield and the chemical oxygen demand removal were improved through the combination of BW and PPME. The best biohydrogen yield of 0.69 mol H2/L medium was obtained using the combination of 10 % BW + 90 % PPME (10B90P), while the reuse of the wastewater alone (100 % BW and 100 % PPME) resulted in 42.3 and 44.0 % less biohydrogen yields than the highest yield, respectively. The greatest light efficiency was 1.97 % and was also achieved using the combination of both wastewaters at 10B90P. This study revealed the potential of reusing and combining two different effluents together, in which the combination of BW and PPME improved the nutrients and light penetration into the mixed production medium.
    Matched MeSH terms: Waste Water*
  2. Subramaniam MN, Goh PS, Kanakaraju D, Lim JW, Lau WJ, Ismail AF
    Environ Sci Pollut Res Int, 2022 Feb;29(9):12506-12530.
    PMID: 34101123 DOI: 10.1007/s11356-021-14676-x
    The presence of conventional and emerging pollutants infiltrating into our water bodies is a course of concern as they have seriously threatened water security. Established techniques such as photocatalysis and membrane technology have proven to be promising in removing various persistent organic pollutants (POP) from wastewaters. The emergence of hybrid photocatalytic membrane which incorporates both photocatalysis and membrane technology has shown greater potential in treating POP laden wastewater based on their synergistic effects. This article provides an in-depth review on the roles of both photocatalysis and membrane technology in hybrid photocatalytic membranes for the treatment of POP containing wastewaters. A concise introduction on POP's in terms of examples, their origins and their effect on a multitude of organisms are critically reviewed. The fundamentals of photocatalytic mechanism, current directions in photocatalyst design and their employment to treat POP's are also discussed. Finally, the challenges and future direction in this field are presented.
    Matched MeSH terms: Waste Water/analysis
  3. Thoa LTK, Thao TTP, Nguyen-Thi ML, Chung ND, Ooi CW, Park SM, et al.
    Chemosphere, 2023 Jun;325:138392.
    PMID: 36921772 DOI: 10.1016/j.chemosphere.2023.138392
    The present study reported the improvement of biological treatment for the removal of recalcitrant dyes including aniline blue, reactive black 5, orange II, and crystal violet in contaminated water. The biodegradation efficiency of Fusarium oxysporum was significantly enhanced by the addition of mediators and by adjusting the biomass density and nutrient composition. A supplementation of 1% glucose in culture medium improved the biodegradation efficiency of aniline blue, reactive black 5, orange II, and crystal violet by 2.24, 1.51, 4.46, and 2.1 folds, respectively. Meanwhile, the addition of mediators to culture medium significantly increased the percentages of total removal for aniline blue, reactive black 5, orange II, and crystal violet, reaching 86.07%, 68.29%, 76.35%, and 95.3%, respectively. Interestingly, the fungal culture supplemented with 1% remazol brilliant blue R boosted the biodegradation up to 97.06%, 89.86%, 91.38%, and 86.67% for aniline blue, reactive black 5, orange II, and crystal violet, respectively. Under optimal culture conditions, the fungal culture could degrade these synthetic dyes concentration up to 104 mg/L. The present study demonstrated that different recalcitrant dye types can be efficiently degraded using microorganism such as F. oxysporum.
    Matched MeSH terms: Waste Water*
  4. Jiang J, Shi Y, Ma NL, Ye H, Verma M, Ng HS, et al.
    Environ Pollut, 2024 Jan 01;340(Pt 1):122830.
    PMID: 37918773 DOI: 10.1016/j.envpol.2023.122830
    The rapid development of the industrial sector has resulted in tremendous economic growth. However, this growth has also presented environmental challenges, specifically due to the substantial sewage generated and its contribution to the early warning of global water resource depletion. Large concentrations of poisonous heavy metals, including cadmium (Cd), chromium (Cr), copper (Cu), lead (Pb), and nickel (Ni), are found in industrial effluent. Therefore, various studies are currently underway to provide effective solutions to alleviate heavy metal ion pollution in sewage. One emerging strategy for sewage pollution remediation is adsorption using wood and its derivatives. This approach is gaining popularity due to the porous structure, excellent mechanical properties, and easy chemical modification of wood. Recent studies have focused on removing heavy metal ions from sewage, summarising and analysing different technical principles, affecting factors, and mainstream chemical modification methods on wood. Furthermore, this work provides insight into potential future development direction for enhanced adsorption of heavy metal ions using wood and its derivatives in wastewater treatment. Overall, this review aims to raise awareness of environmental pollution caused by heavy metals in sewage and promote green environmental protection, low-carbon energy-saving, and sustainable solutions for sewage heavy metal treatment.
    Matched MeSH terms: Waste Water*
  5. Husain Khan A, Abdul Aziz H, Palaniandy P, Naushad M, Cevik E, Zahmatkesh S
    Chemosphere, 2023 Oct;339:139647.
    PMID: 37516325 DOI: 10.1016/j.chemosphere.2023.139647
    Hospital wastewater has emerged as a major category of environmental pollutants over the past two decades, but its prevalence in freshwater is less well documented than other types of contaminants. Due to compound complexity and improper operations, conventional treatment is unable to remove pharmaceuticals from hospital wastewater. Advanced treatment technologies may eliminate pharmaceuticals, but there are still concerns about cost and energy use. There should be a legal and regulatory framework in place to control the flow of hospital wastewater. Here, we review the latest scientific knowledge regarding effective pharmaceutical cleanup strategies and treatment procedures to achieve that goal. Successful treatment techniques are also highlighted, such as pre-treatment or on-site facilities that control hospital wastewater where it is used in hospitals. Due to the prioritization, the regulatory agencies will be able to assess and monitor the concentration of pharmaceutical residues in groundwater, surface water, and drinking water. Based on the data obtained, the conventional WWTPs remove 10-60% of pharmaceutical residues. However, most PhACs are eliminated during the secondary or advanced therapy stages, and an overall elimination rate higher than 90% can be achieved. This review also highlights and compares the suitability of currently used treatment technologies and identifies the merits and demerits of each technology to upgrade the system to tackle future challenges. For this reason, pharmaceutical compound rankings in regulatory agencies should be the subject of prospective studies.
    Matched MeSH terms: Waste Water*
  6. Fathima A, Ilankoon IMSK, Zhang Y, Chong MN
    Sci Total Environ, 2024 Feb 20;912:169186.
    PMID: 38086487 DOI: 10.1016/j.scitotenv.2023.169186
    Impetus to minimise the energy and carbon footprints of evolving wastewater resource recovery facilities has promoted the development of microbial electrochemical systems (MES) as an emerging energy-neutral and sustainable platform technology. Using separators in dual-chamber MES to isolate anodic and cathodic environments creates endless opportunities for its myriad applications. Nevertheless, the high internal resistance and the complex interdependencies among various system factors have challenged its scale-up. This critical review employed a systems approach to examine the complex interdependencies and practical issues surrounding the implementation and scalability of dual-chamber MES, where the anodic and cathodic reactions are mutually appraised to improve the overall system efficiency. The robustness and stability of anodic biofilms in large-volume MES is dependent on its inoculum source, antecedent history and enrichment strategies. The composition and anode-respiring activity of these biofilms are modulated by the anolyte composition, while their performance demands a delicate balance between the electrode size, macrostructure and the availability of substrates, buffers and nutrients when using real wastewater as anolyte. Additionally, the catholyte governed the reduction environment and associated energy consumption of MES with scalable electrocatalysts needed to enhance the sluggish reaction kinetics for energy-efficient resource recovery. A comprehensive assessment of the dual-chamber reactor configuration revealed that the tubular, spiral-wound, or plug-in modular MES configurations are suitable for pilot-scale, where it could be designed more effectively using efficient electrode macrostructure, suitable membranes and bespoke strategies for continuous operation to maximise their performance. It is anticipated that the critical and analytical understanding gained through this review will support the continuous development and scaling-up of dual-chamber MES for prospective energy-neutral treatment of wastewater and simultaneous circular management of highly relevant environmental resources.
    Matched MeSH terms: Waste Water*
  7. Chong SS, Aziz AR, Harun SW
    Sensors (Basel), 2013 Jul 05;13(7):8640-68.
    PMID: 23881131 DOI: 10.3390/s130708640
    Demand for online and real-time measurements techniques to meet environmental regulation and treatment compliance are increasing. However the conventional techniques, which involve scheduled sampling and chemical analysis can be expensive and time consuming. Therefore cheaper and faster alternatives to monitor wastewater characteristics are required as alternatives to conventional methods. This paper reviews existing conventional techniques and optical and fibre optic sensors to determine selected wastewater characteristics which are colour, Chemical Oxygen Demand (COD) and Biological Oxygen Demand (BOD). The review confirms that with appropriate configuration, calibration and fibre features the parameters can be determined with accuracy comparable to conventional method. With more research in this area, the potential for using FOS for online and real-time measurement of more wastewater parameters for various types of industrial effluent are promising.
    Matched MeSH terms: Waste Water/analysis*; Waste Water/chemistry
  8. Wang J, Mahmood Q, Qiu JP, Li YS, Chang YS, Chi LN, et al.
    Biomed Res Int, 2015;2015:617861.
    PMID: 25685798 DOI: 10.1155/2015/617861
    Palm oil is one of the most important agroindustries in Malaysia. Huge quantities of palm oil mill effluent (POME) pose a great threat to aqueous environment due to its very high COD. To make full use of discharged wastes, the integrated "zero discharge" pilot-scale industrial plant comprising "pretreatment-anaerobic and aerobic process-membrane separation" was continuously operated for 1 year. After pretreatment in the oil separator tank, 55.6% of waste oil in raw POME could be recovered and sold and anaerobically digested through 2 AnaEG reactors followed by a dissolved air flotation (DAF); average COD reduced to about 3587 mg/L, and biogas production was 27.65 times POME injection which was used to generate electricity. The aerobic effluent was settled for 3 h or/and treated in MBR which could remove BOD3 (30°C) to less than 20 mg/L as required by Department of Environment of Malaysia. After filtration by UF and RO membrane, all organic compounds and most of the salts were removed; RO permeate could be reused as the boiler feed water. RO concentrate combined with anaerobic surplus sludge could be used as biofertilizer.
    Matched MeSH terms: Waste Water*
  9. Gobi K, Vadivelu VM
    Bioresour Technol, 2014 Jun;161:441-5.
    PMID: 24725384 DOI: 10.1016/j.biortech.2014.03.104
    Aerobic dynamic feeding (ADF) strategy was applied in sequencing batch reactor (SBR) to accumulate polyhydroxyalkanoate (PHA) in aerobic granules. The aerobic granules were able to remove 90% of the COD from palm oil mill effluent (POME). The volatile fatty acids (VFAs) in the POME are the sole source of the PHA accumulation. In this work, 100% removal of propionic and butyric acids in the POME were observed. The highest amount of PHA produced in aerobic granules was 0.6833mgPHA/mgbiomass. The PHA formed was identified as a P (hydroxybutyrate-co-hydroxyvalerate) P (HB-co-HV).
    Matched MeSH terms: Waste Water/chemistry
  10. Lin CY, Lay CH, Chew KW, Nomanbhay S, Gu RL, Chang SH, et al.
    Chemosphere, 2021 Feb;264(Pt 2):128564.
    PMID: 33065325 DOI: 10.1016/j.chemosphere.2020.128564
    Recently, the production of renewable biogas such as biohydrogen and biomethane from wastewaters through anaerobic fermentation has gained worldwide attention. In the present study, a mobile bioenergy generation station had been constructed based on a high-efficiency hydrogenesis & methanogenesis technology (HyMeTek) developed by Feng Chia University, Taiwan. The substrate was a beverage wastewater having chemical oxygen demand (COD) concentration of 1200 mg/L. This bioenergy station had a feedstock tank (3.8 m3), a nutrient tank (0.8 m3), an acidogenesis tank (AT, 2 m3), two methanogenesis tanks (MT, 4 m3 for each), a membrane bioreactor and a control room. Biogas production rate, methane concentration, COD removal efficiencies, energy efficiency and economical interest of the plant were assessed. The peak total methane production rates for AT (at hydraulic retention time, HRT, 4 h) and MT (at HRT 8 h) were 430 and 7 mL/L·d, respectively. A strategy of shortening HRT was a promising method to enhance biogas quality and energy efficiency. This mobile bioenergy system has commercial potential because it could bring good economic benefit of initial rate of return (58.84%) and payback time (2.68 y).
    Matched MeSH terms: Waste Water*
  11. Sarmin S, Ethiraj B, Islam MA, Ideris A, Yee CS, Khan MMR
    Sci Total Environ, 2019 Dec 10;695:133820.
    PMID: 31416036 DOI: 10.1016/j.scitotenv.2019.133820
    The petrochemical wastewater (PCW) from acrylic acid plants possesses a very high chemical oxygen demand (COD) due to the presence of acrylic acid along with other organic acids. The treatment of PCW by conventional aerobic and anaerobic methods is energy intensive. Therefore, the treatment of PCW with concurrent power generation by employing microbial fuel cell (MFC) could be a potential alternative to solve the energy and environmental issues. This study demonstrates the potentiality of PCW from acrylic acid plant with an initial COD of 45,000 mg L-1 generating maximum power density of 850 mW m-2 at a current density of 1500 mA m-2 using acclimatized anaerobic sludge (AS) as biocatalyst. The predominant microbes present in acclimatized AS were identified using Biolog GEN III analysis, which include the electrogenic genera namely Pseudomonas spp. and Bacillus spp. along with methanogenic archea Methanobacterium spp. The mechanism of electron transfer was elucidated by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) which clearly demonstrated the natural metabolite-based electron transfer across the electrode/biofilm/solution interface. The abundance of the electron shuttle metabolites was increased with the microbial growth in the bulk solution as well as in the biofilm leading to a high power generation. The COD removal efficiency and the coulombic efficiency (CE) were found to be 40% and 21%, respectively after 11 days of operation using initial COD of 45,000 mg L-1. The low COD removal efficiency could drastically be increased to 82% when the initial COD of PCW was 5000 mg L-1 generating a power density of 150 mW m-2. The current work proves the feasibility of the MFC for the treatment of acrylic acid plant PCW using acclimatized anaerobic sludge (AS) as a biocatalyst.
    Matched MeSH terms: Waste Water/microbiology
  12. Priya AK, Pachaiappan R, Kumar PS, Jalil AA, Vo DN, Rajendran S
    Environ Pollut, 2021 Apr 15;275:116598.
    PMID: 33581625 DOI: 10.1016/j.envpol.2021.116598
    Anthropogenic activities and population growth have resulted in a reduced availability of drinking water. To ensure consistency in the existence of drinking water, it is inevitable to establish wastewater treatment plants (WWTPs). 70% of India's rural population was found to be without WWTP, waste disposal, and good sanitation. Wastewater has emerged from kitchens, washrooms, etc., with industry activities. This scenario caused severe damage to water resources, leading to degradation of water quality and pathogenic insects. Thus, it is a need of an hour to prompt for better WWTPs for both rural and urban areas. Many parts of the world have started to face severe water shortages in recent years, and wastewater reuse methods need to be updated. Clean water supply is not enough to satisfy the needs of the planet as a whole, and the majority of freshwater in the polar regions takes the form of ice and snow. The increasing population requires clean water for drinks, hygiene, irrigation, and various other applications. Lack of water and contamination of water result from human activities. 90% of wastewater is released to water systems without treatment in developing countries. Studies show that about 730 megatons of waste are annually discharged into water from sewages and other effluents. The sustenance of water resources, applying wastewater treatment technologies, and calling down the percentage of potable water has to be strictly guided by mankind. This review compares the treatment of domestic sewage to its working conditions, energy efficiency, etc. In this review, several treatment methods with different mechanisms involved in waste treatment, industrial effluents, recovery/recycling were discussed. The feasibility of bioaugmentation should eventually be tested through data from field implementation as an important technological challenge, and this analysis identifies many promising areas to be explored in the future.
    Matched MeSH terms: Waste Water*
  13. Phoon BL, Ong CC, Mohamed Saheed MS, Show PL, Chang JS, Ling TC, et al.
    J Hazard Mater, 2020 12 05;400:122961.
    PMID: 32947727 DOI: 10.1016/j.jhazmat.2020.122961
    Antibiotics and pharmaceuticals related products are used to enhance public health and quality of life. The wastewater that is produced from pharmaceutical industries still contains noticeable amount of antibiotics, and this has remained one of the major environmental problems facing public health. The conventional wastewater remediation approach employed by the pharmaceutical industries for the antibiotics wastewater removal is unable to remove the antibiotics completely. Besides, municipal and livestock wastewater also contain unmetabolized antibiotics released by human and animal, respectively. The antibiotic found in wastewater leads to antibiotic resistance challenges, also emergence of superbugs. Currently, numerous technological approaches have been developed to remove antibiotics from the wastewater. Therefore, it was imperative to critically review the weakness and strength of these current advanced technological approaches in use. Besides, the conventional methods for removal of antibiotics such as Klavaroti et al., Homem and Santos also discussed. Although, membrane treatment is discovered as the ultimate choice of approach, to completely remove the antibiotics, while the filtered antibiotics are still retained on the membrane. This study found, hybrid processes to be the best solution antibiotics removal from wastewater. Nevertheless, real-time monitoring system is also recommended to ascertain that, wastewater is cleared of antibiotics.
    Matched MeSH terms: Waste Water*
  14. Hung YT, Aziz HA, Ramli SF, Paul HH, Huhnke CR, Adesanmi BM
    Water Environ Res, 2020 Oct;92(10):1504-1509.
    PMID: 32659868 DOI: 10.1002/wer.1399
    This paper reviews the related literature reported in 2019 about various types of wastewaters associated with chemical and allied products. The subjects comprise wastewaters produced from various activities in agricultural, chemical, dye, petrochemical, and pharmaceutical. PRACTITIONER POINTS: Bioflocculant chitosan was used for sludge dewatering and the treatment of water and wastewater, and polishing of sanitary landfill leachate. Alkaline lignin-based flocculants were used to achieve excellent color removal for paper mill sludge. Powdered activated coke was used to remove COD (chemical oxygen demand) from chemical industry wastewater effluents.
    Matched MeSH terms: Waste Water*
  15. Ahmed SF, Mofijur M, Nuzhat S, Chowdhury AT, Rafa N, Uddin MA, et al.
    J Hazard Mater, 2021 08 15;416:125912.
    PMID: 34492846 DOI: 10.1016/j.jhazmat.2021.125912
    Emerging contaminants (ECs) in wastewater have recently attracted the attention of researchers as they pose significant risks to human health and wildlife. This paper presents the state-of-art technologies used to remove ECs from wastewater through a comprehensive review. It also highlights the challenges faced by existing EC removal technologies in wastewater treatment plants and provides future research directions. Many treatment technologies like biological, chemical, and physical approaches have been advanced for removing various ECs. However, currently, no individual technology can effectively remove ECs, whereas hybrid systems have often been found to be more efficient. A hybrid technique of ozonation accompanied by activated carbon was found significantly effective in removing some ECs, particularly pharmaceuticals and pesticides. Despite the lack of extensive research, nanotechnology may be a promising approach as nanomaterial incorporated technologies have shown potential in removing different contaminants from wastewater. Nevertheless, most existing technologies are highly energy and resource-intensive as well as costly to maintain and operate. Besides, most proposed advanced treatment technologies are yet to be evaluated for large-scale practicality. Complemented with techno-economic feasibility studies of the treatment techniques, comprehensive research and development are therefore necessary to achieve a full and effective removal of ECs by wastewater treatment plants.
    Matched MeSH terms: Waste Water/analysis
  16. Balaji R, Lee Siang H, Yaakob O, Koh KK, Adnan FAB, Ismail NB, et al.
    Environ Technol, 2018 May;39(9):1102-1114.
    PMID: 28425309 DOI: 10.1080/09593330.2017.1321691
    Waste heat recovery from shipboard machineries could be a potential source for heat treatment of ballast water. Similar to a shipboard schematic arrangement, a laboratory-scale engine-heat exchanger set-up harvesting waste heat from jacket water and exhaust gases was erected to test the level of species' mortalities. Mortalities were also assessed under experimental conditions for cultured and natural plankton communities at laboratory level. Effect of pump impellers on species' mortalities were also tested. Exposures between 60°C and 70°C for 60 sec resulted in 80-100% mortalities. Mortalities due to pump impeller effects were observed in the range of 70-100% for zooplankton. On the laboratory-scale arrangement, >95% mortalities of phytoplankton, zooplankton and bacteria were recorded. It was demonstrated that the temperature of tropical sea waters used as secondary coolant can be raised to cause species' mortalities, employing engine exhaust gases. The results also indicated that pump impeller effects will enhance species' mortalities. The limitations of the shipboard application of this method would be the large ballast volumes, flow rates and time for treatment.
    Matched MeSH terms: Waste Water*
  17. Gani P, Sunar NM, Matias-Peralta H, Mohamed RMSR, Latiff AAA, Parjo UK
    Int J Phytoremediation, 2017 Jul 03;19(7):679-685.
    PMID: 28121457 DOI: 10.1080/15226514.2017.1284743
    This study was undertaken to analyze the efficiency of Botryococcus sp. in the phycoremediation of domestic wastewater and to determine the variety of hydrocarbons derived from microalgal oil after phycoremediation. The study showed a significant (p < 0.05) reduction of pollutant loads of up to 93.9% chemical oxygen demand, 69.1% biochemical oxygen demand, 59.9% total nitrogen, 54.5% total organic carbon, and 36.8% phosphate. The average dry weight biomass produce was 0.1 g/L of wastewater. In addition, the dry weight biomass of Botryococcus sp. was found to contain 72.5% of crude oil. The composition analysis using Gas Chromatogram - Mass Spectrometry (GC-MS) found that phthalic acid, 2-ethylhexyltridecyl ester (C29H48O4), contributed the highest percentage (71.6%) of the total hydrocarbon compounds to the extracted algae oil. The result of the study suggests that Botryococcus sp. can be used for effective phycoremediation, as well as to provide a sustainable hydrocarbon source as a value-added chemical for the bio-based plastic industry.
    Matched MeSH terms: Waste Water*
  18. Nguyen TDP, Le TVA, Show PL, Nguyen TT, Tran MH, Tran TNT, et al.
    Bioresour Technol, 2019 Jan;272:34-39.
    PMID: 30308405 DOI: 10.1016/j.biortech.2018.09.146
    Microalgal bacterial flocs can be a promising approach for microalgae harvesting and wastewater treatment. The present study provides an insight on the bioflocs formation to enhance harvesting of Chlorella vulgaris and the removal of nutrients from seafood wastewater effluent. The results showed that the untreated seafood wastewater was the optimal culture medium for the cultivation and bioflocculation of C. vulgaris, with the flocculating activity of 92.0 ± 6.0%, total suspended solids removal of 93.0 ± 5.5%, and nutrient removal of 88.0 ± 2.2%. The bioflocs collected under this optimal condition contained dry matter of 107.2 ± 5.6 g·L-1 and chlorophyll content of 25.5 ± 0.2 mg·L-1. The results were promising when compared to those obtained from the auto-flocculation process that induced by the addition of calcium chloride and pH adjustment. Additionally, bacteria present in the wastewater aided to promote the formation of bioflocculation process.
    Matched MeSH terms: Waste Water/microbiology*
  19. Ismail Z, Aziz MMA, Mahmood NAN, Ismail S, Umor NA, Faua'ad Syed Muhammad SA
    J Environ Manage, 2018 Nov 15;226:156-162.
    PMID: 30119039 DOI: 10.1016/j.jenvman.2018.08.003
    Oleochemicals industry effluence mainly contains a high chemical oxygen demand (COD) in a range of 6000-20,000 ppm. An effective biological wastewater treatment process must be carried out before wastewater is discharged into the environment. In this study, a submerged bed biofilm reactor (SBBR) was adapted to the biological oleochemical wastewater treatment plant observed in the present study. The effect of wastewater flow rate (100-300 mL/min), Cosmoball® percentage in the SBBR system (25-75%), and percentage of activated sludge (0-50%) were investigated in terms of COD reduction. The Box-Behnken design was used for response surface methodology (RSM) and to create a set of 18 experimental runs, which was needed for optimising the biological oleochemical wastewater treatment. A quadratic polynomial model with estimated coefficients was developed to describe COD reduction patterns. The analysis of variance (ANOVA) shows that the wastewater flow rate was the most effective factor in reducing COD, followed by activated sludge percentage and Cosmoball® carrier percentage. Under the optimum conditions (i.e., a wastewater flow rate of 103.25 mL/min a Cosmoball® carrier percentage of 71.94%, and an activated sludge percentage of 40.50%) a COD reduction of 98% was achieved. Thus, under optimum conditions, as suggested by the BBD, SBBR systems can be used as a viable means of biological wastewater treatment in the oleochemicals industry.
    Matched MeSH terms: Waste Water*
  20. How SW, Sin JH, Wong SYY, Lim PB, Mohd Aris A, Ngoh GC, et al.
    Water Sci Technol, 2020 Jan;81(1):71-80.
    PMID: 32293590 DOI: 10.2166/wst.2020.077
    Many developing countries, mostly situated in the tropical region, have incorporated a biological nitrogen removal process into their wastewater treatment plants (WWTPs). Existing wastewater characteristic data suggested that the soluble chemical oxygen demand (COD) in tropical wastewater is not sufficient for denitrification. Warm wastewater temperature (30 °C) in the tropical region may accelerate the hydrolysis of particulate settleable solids (PSS) to provide slowly-biodegradable COD (sbCOD) for denitrification. This study aimed to characterize the different fractions of COD in several sources of low COD-to-nitrogen (COD/N) tropical wastewater. We characterized the wastewater samples from six WWTPs in Malaysia for 22 months. We determined the fractions of COD in the wastewater by nitrate uptake rate experiments. The PSS hydrolysis kinetic coefficients were determined at tropical temperature using an oxygen uptake rate experiment. The wastewater samples were low in readily-biodegradable COD (rbCOD), which made up 3-40% of total COD (TCOD). Most of the biodegradable organics were in the form of sbCOD (15-60% of TCOD), which was sufficient for complete denitrification. The PSS hydrolysis rate was two times higher than that at 20 °C. The high PSS hydrolysis rate may provide sufficient sbCOD to achieve effective biological nitrogen removal at WWTPs in the tropical region.
    Matched MeSH terms: Waste Water*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links