Displaying publications 41 - 60 of 286 in total

Abstract:
Sort:
  1. Abdul Razak Daud, Azleen Mohd. Zain, Azali Muhamad
    A single wall single image x-ray radiographic technique was adopted to investigate thickness variation of steel specimens caused by uniform corrosion. The ability of the 100 kV-160 kV x-rays to produce a meaningful film density for steel was also investigated. The thickness contour maps of corroded steel plates were found matching with the x-ray film density contour maps of the plates. The results confirm that x-ray radiography can be used to detect the thickness reduction of steel caused by uniform corrosion.
    Bagi mengesan perubahan ketebalan keluli akibat kakisan seragam maka radiografi sinar-x teknik imej tunggal dinding tunggal telah digunakan. Kemampuan sinar-x 100 kV-160 kV menghasilkan ketumpatan filem yang sesuai untuk keluli telah juga dikaji. Peta kontur ketebalan bagi spesimen kepingan keluli yang telah mengalami kakisan seragam didapati sepadan dengan peta kontur ketumpatan filem radiografi sinar-x bagi spesimen tersebut. Kajian ini menunjukkan radiografi sinar-x boleh digunakan bagi mengesan penipisan keluli akibat kakisan seragam.
    Matched MeSH terms: X-Rays
  2. Talebi A, Razali YS, Ismail N, Rafatullah M, Azan Tajarudin H
    Sci Total Environ, 2020 Mar 10;707:134533.
    PMID: 31865088 DOI: 10.1016/j.scitotenv.2019.134533
    An adsorption-desorption process was applied on fermented landfill leachate to adsorb and recover acetic and butyric acid, using activated carbon. In this study, the first, volatile fatty acids adsorption process from fermented leachate was optimized, by investigating various affecting factors such as pH, time, agitation speed, activated carbon dosage, and temperature. The optimum condition for maximum adsorption of 88.94% acetic acid and 98.53% butyric acid, was 19.79 %wt activated carbon dosage, 40.00 rpm of agitation speed, in 9.45 °C and contact time of 179.89 h, while the pH of the substrate was kept fixed at pH:3.0. Results of X-ray fluorescence (XRF) spectrometry, X-ray diffraction (XRD), Fourier transform infrared (FT-IR) and zeta potential revealed that carbon is the dominant component in the adsorbent with a significant effect to remove organic impurities, and it was observed that the activated carbon after the adsorption process showed an amorphous structure peak with a large internal surface area and pore volume. The results exposed that the adsorption on the surface of activated carbon was due to the chemisorption, and the chemisorption mechanism was supported by covalent bonding. The kinetic study displayed excellent fit to Pseudo-second order kinetics model. The second phase of this study was to recover the adsorbed VFAs using multistage desorption unit, in which application of deionized water and ethanol (as desorption agents) resulted in 89.1% of acetic acid and 67.8% of the butyric acid recovery.
    Matched MeSH terms: X-Rays
  3. Azimi EA, Abdullah MMAB, Vizureanu P, Salleh MAAM, Sandu AV, Chaiprapa J, et al.
    Materials (Basel), 2020 Feb 24;13(4).
    PMID: 32102345 DOI: 10.3390/ma13041015
    A geopolymer has been reckoned as a rising technology with huge potential for application across the globe. Dolomite refers to a material that can be used raw in producing geopolymers. Nevertheless, dolomite has slow strength development due to its low reactivity as a geopolymer. In this study, dolomite/fly ash (DFA) geopolymer composites were produced with dolomite, fly ash, sodium hydroxide, and liquid sodium silicate. A compression test was carried out on DFA geopolymers to determine the strength of the composite, while a synchrotron Micro-Xray Fluorescence (Micro-XRF) test was performed to assess the elemental distribution in the geopolymer composite. The temperature applied in this study generated promising properties of DFA geopolymers, especially in strength, which displayed increments up to 74.48 MPa as the optimum value. Heat seemed to enhance the strength development of DFA geopolymer composites. The elemental distribution analysis revealed exceptional outcomes for the composites, particularly exposure up to 400 °C, which signified the homogeneity of the DFA composites. Temperatures exceeding 400 °C accelerated the strength development, thus increasing the strength of the DFA composites. This appears to be unique because the strength of ordinary Portland Cement (OPC) and other geopolymers composed of other raw materials is typically either maintained or decreases due to increased heat.
    Matched MeSH terms: X-Rays
  4. Siew PF, Wan Yusmawati Wan Yusoff, Azman Jalar
    Sains Malaysiana, 2014;43:827-832.
    The physical properties and structural stability of the Quad Flat No-Leads (QFN) package with different gamma radiation doses have been investigated. The packages were irradiated with Co-60 gamma radiation with varying doses of 5 Gy, 50 Gy, 500 Gy, 5 kGy and 50 kGy with operating dose of 2.54 kGylh at room temperature. The infinite focus microscope (IFM) was used to measure the dimensional change and slantinglwarpage behaviour, while the 3D CT Scan X-ray machine was used to determine the occurrence of deflection on a wire in package due to exposure. It is believed that radiation effect on ceramic filler in the epoxy mold compound (EMC) plays an important role to induce the defects and resulted in swelling of the package. The slantinglwarpage behaviour is believed to be caused by the swelling behaviour of ceramic filler and further induced structural stability. The induced stress on the EMC structural after the dimensional change and slantinglwarpage failure leads to the occurrence of wire sweep. The finding suggests that defect production in swelled ceramic filler leads to the occurrence of dimensional and structure instability.
    Matched MeSH terms: X-Rays
  5. Wan Nasarudin Wan Jalal, Huda Abdullah, Mohd Syafiq Zulfakar, Sahbudin Shaari, Mohammad Thariqul Islam, Badariah Bais
    Sains Malaysiana, 2014;43:833-842.
    CaxZn(1_x)Al204thin films (x = 0.00; 0 .05 ; 0.10; 0.15 and 0.20) were prepared by sol-gel method with the substitution of Zn2+ by Ca" in the framework of ZnAl204. The effect of Ca addition on the structure and morphology of CaZnAl204thin films was investigated by x-ray diffraction (xRD), field-emission scanning electron microscope (FESEM), energy-dispersive x-ray spectroscopy (EDx), ultra-violet visible (uv-Vis) and atomic force microscope (AFM). The xRD patterns showed the characteristic peaks of face-centred cubic (fcc)ZnAl204and CaZnAl204. The addition of Ca increased the crystallite size from 8.9 to 302 nm. The bandgap of CaxZnuld204 thin film was found in the range of 3.40 to 3.84 eV. sEm micrograph shows the morphology of all thin films is sphere-like, with the grain size increased from 33 to 123 nm. The AFM images show the roughness of surface morphology increased. The substitution of Zn2+ by Ca" increased the crystallite size, grain size and surface roughness which evidently increased the density (4.59 to 4.64 glcm3) and dielectric constant (8.48 to 9.54). The composition of CaxZn(1_x)Al204is considered as suitable material for GPS patch antennas.
    Matched MeSH terms: X-Rays
  6. Mousavi Z, Soofivand F, Esmaeili-Zare M, Salavati-Niasari M, Bagheri S
    Sci Rep, 2016 Feb 01;6:20071.
    PMID: 26832329 DOI: 10.1038/srep20071
    In this work, zinc chromite (ZnCr2O4) nanostructures have been synthesized through co-precipitation method. The effect of various parameters such as alkaline agent, pH value, and capping agent type was investigated on purity, particle size and morphology of samples. It was found that particle size and morphology of the products could be greatly influenced via these parameters. The synthesized products were characterized by field emission scanning electron microscopy (FESEM), X-ray diffraction (XRD), fourier transform infrared (FT-IR) spectra, X-ray energy dispersive spectroscopy (EDS), photoluminescence (PL) spectroscopy, diffuse reflectance spectroscopy (DRS) and vibrating sample magnetometry (VSM). The superhydrophilicity of the calcined oxides was investigated by wetting experiments and a sessile drop technique which carried out at room temperature in air to determine the surface and interfacial interactions. Furthermore, the photocatalytic activity of ZnCr2O4 nanoparticles was confirmed by degradation of anionic dyes such as Eosin-Y and phenol red under UV light irradiation. The obtained ZnCr2O4 nanoparticles exhibit a paramagnetic behavior although bulk ZnCr2O4 is antiferromagnetic, this change in magnetic property can be ascribed to finite size effects.
    Matched MeSH terms: X-Rays
  7. Rufai Y, Chandren S, Basar N
    Front Chem, 2020;8:597980.
    PMID: 33344417 DOI: 10.3389/fchem.2020.597980
    Nanotechnology is one of the most interesting areas of research due to its flexibility to improve or form new products from nanoparticles (NPs), and as a fast, greener, more eco-friendly and sustainable solution to technological and environmental challenges. Among metal oxides of photocatalytic performance, the use of titania (TiO2) as photocatalyst is most popular due to its unique optical and electronic properties. Despite the wide utilization, the synthesis of TiO2 NPs bears many disadvantages: it utilizes various less environmental-friendly chemicals, high cost, requires high pressure and energy, and potentially hazardous physical and chemical methods. Hence, the development of green synthesis approach with eco-friendly natural products can be used to overcome these adverse effects. In this work, TiO2 NPs have been prepared by using Deinbollia pinnata leaves extracts, obtained by different solvents (n-hexane, ethyl acetate, and ethanol) with different polarities. The extracts acted as the reducing agent, while titanium isopropoxide as the precursor and water as the solvent. X-ray diffraction (XRD) pattern confirmed the synthesized TiO2 consist of anatase phase in high purity, with average crystallite size in the range of 19-21 nm. Characterization by using field emission scanning electron microscopy (FESEM) showed the TiO2 NPs possess a uniform semi-spherical shape in the size range of 33-48 nm. The energy dispersive X-ray (EDX) spectra of green TiO2 NPs showed two peaks for the main elements of Ti (61 Wt.%) and O (35 Wt.%). The band-gap energy of 3.2 eV was determined using UV-Vis spectroscopy. From the nitrogen sorption analysis, type V isotherm of the material was obtained, with BET surface area of 31.77 m2/g. The photocatalytic activity of synthesized TiO2 was evaluated for photodegradation of methyl orange (MO) under UV light irradiation. Based on the results, it is shown that TiO2 NPs synthesized with D. pinnata leaves extracted using ethyl acetate showed the most effective photodegradation performance, achieving 98.7% of MO conversion within 150 min. It can be concluded that the use of plant extracts in synthesis with TiO2 managed to produce highly crystalline anatase TiO2 with superior photocatalytic activity in the photodegradation of organic dye.
    Matched MeSH terms: X-Rays
  8. Benjamin Ng Han Sim
    MyJurnal
    Phasic ECG voltage changes or electrical alternans is a well-described ECG changes seen in the pericardial effusion and cardiac tamponade. Popular as once believed, this ECG features are no longer considered pathognomonic for pericardial effusion and cardiac tamponade. Electric alternans is observed in pneumothorax especially left-sided pneumothorax. This is a case of a 41-year-old man who presented with chest pain and breathlessness to the emergency department. Assessment in the emergency unit revealed an obvious distress man with a respiratory rate of 60 breaths/min with cyanosis There were generalised rhonchi and prolonged expiratory breath sound appreciated. Chest X-ray (CXR) was done and diagnosed to have left tension pneumothorax. Initial electrocardiogram (ECG) showed electrical alternans in all leads. He was intubated for respiratory distress followed by chest tube insertion. His initial ECG findings resolved after treatment of the tension pneumothorax. Doctors need to evaluate the cardiac findings along with respiratory findings.
    Matched MeSH terms: X-Rays
  9. Choo YSL, Giamberini M, Antonio J, Waddell PG, Benniston AC
    Org Biomol Chem, 2020 Nov 04;18(42):8735-8745.
    PMID: 33094783 DOI: 10.1039/d0ob01533d
    The reaction of diethyl 2,5-bis(tert-butyl)phenoxy-3,6-dihydroxyterephthalate (1) with tetraethylene glycol di(p-toluenesulfonate) under high-dilution conditions afforded several isolated products. Two products were identified as macrocycles with one being the 1 + 1 crown ether derivative 3 (10% yield), and the second being the 2 + 2 crown ether compound D3 (19% yield). The X-ray structure for 3 was determined with the asymmetric unit observed to comprise half of the molecule. The small crown ether ring of 3 interacts with K+ or H+ ions in MeOH, but binding is weak and the macrocyclic cavity is too small to fully encapsulate the K+ ion. Transesterification of compounds 1, its methylated version 2 and 3 with diols such as ethylene glycol or 1,4-butandiol produced monomers (M1-M3) which were reacted with terephthaloyl chloride. Short oligomers were produced (PolyM1-PolyM3) rather than extensive polymeric materials and all displayed solid state fluorescence. The absorption and fluorescence properties of M1-M2 and their polymers can be related to subtle structural changes. The Stokes shift for M2 of 15 627 cm-1 in DCM is one of the largest observed for a simple organic chromophore in fluid solution.
    Matched MeSH terms: X-Rays
  10. Das BK, Biswal BM, Bhavaraju M
    Malays J Med Sci, 2006 Jan;13(1):52-7.
    PMID: 22589591 MyJurnal
    X-ray mammography has been the backbone of early detection of breast cancer. Several large scale systematic studies have shown that judicious use of X-ray mammography can indeed save life. However, though reasonably sensitive, X-ray mammography lacks in specificity leading to many unnecessary biopsies. Scintimammography is a relatively new imaging method to demonstrate cancer tissue in the breast. A radiopharmaceutical agent (Tc-99m Sestamibi) is administered intravenously and images of the breast are taken under a Gamma Camera. There is no need for any manipulation like compression of the breast as required to be done during mammography. The radiopharmaceutical accumulates in the breast in the presence of cancer tissue which can easily be seen in the images. The affinity of the cancer tissue to this radiopharmaceutical is up to 9 times in comparison to normal breast tissue. Several multi centric studies with blinded image interpretation have established the sensitivity and specificity of scintimammography to be above 85 and 90 % respectively as compared to 89 and 14 % respectively for X-ray mammography. The positive and negative predictive values of scintimamography are 70 and 83 % as against 49 and 57 % respectively for X-ray mammography. With the increasing availability of Nuclear Medicine facilities it is expected that more and more patients will benefi with the use of this new imaging modality .
    Matched MeSH terms: X-Rays
  11. Oh WC, Fatema KN, Liu Y, Jung CH, Sagadevan S, Biswas MRUD
    ACS Omega, 2020 Jul 21;5(28):17337-17346.
    PMID: 32715218 DOI: 10.1021/acsomega.0c01699
    In this study, we demonstrate the fabrication and characterization of a new quaternary semiconductor nanocomposite of LiCuMo2O11/graphene oxide/polypyrrole (LCMGP) via a hydrothermal method and testing of an NH3 and H2SO4 sensor operating in gaseous states at room temperature. We used X-ray diffraction, transmission electron microscopy, scanning electron microscopy, energy-dispersive X-ray spectroscopy, and X-ray photoelectron spectroscopy to characterize the properties of LCMGP nanostructures. Our sensor is capable of detecting NH3 and H2SO4 and quantifying their concentration in the gas flow. These results have been confirmed by exposing the sensor to different concentrations of NH3 and H2SO4 (100-1000 ppm). The obtained results confirm the exceptional sensing properties of the graphene-polymer-combined quaternary semiconductor nanocomposite related to the oxidation-reduction process that can be used for detection, identification, and quantification purposes.
    Matched MeSH terms: X-Rays
  12. Nur Aqilah Zainal, Shariff Ibrahim, Borhannuddin Arifin
    MyJurnal
    An agricultural waste, the cocoa pod husk was chemically modified using a dehydrating agent, zinc chloride (ZnCl2), carbonised and used for the remediation of acid dyes in an aqueous solution. The targeted acid dyes are: (i) Acid Violet 17 (AV17); (ii) Acid Yellow 36 (AY36); and (iii) Acid Blue 29 (AB29). The physicochemical properties of the zinc chloride-modified cocoa pod husk-based carbon (ZCPHC) were characterised by ash content, bulk density, pH slurry, pHpzc and Field Emission Scanning Electron Microscopy (FESEM) and Energy Dispersive X-Ray (EDX) analysis. The bulk density and ash content of the prepared carbon is 0.55 g cm-1 and 7.0% respectively. The photograph of SEM shows distinct changes at the ZCPHC carbon surface as it has large pores formed due to ZnCl2 modification. The adsorption tests were performed in a batch adsorption system using an aqueous solution of the understudy acid dyes. The influence of pH and dose of an adsorbent on the acid dye uptake was investigated and discussed. The adsorption was in favour at acidic condition with maximum removal observed at pH 2. The removal efficiency of the aqueous acid dye solution increased with the increase in adsorbent dosage. The kinetic experiment showed equilibrium time is less than 40 minutes and the kinetic data for all three understudy acid dyes fitted well with the pseudo-second-order model with a correlation coefficient (R2) values above 0.98.
    Matched MeSH terms: X-Rays
  13. Alkhorayef M, Sulieman A, Barakat H, Al-Mohammed HI, Theodorou K, Kappas C, et al.
    Saudi J Biol Sci, 2021 Jan;28(1):35-39.
    PMID: 33424280 DOI: 10.1016/j.sjbs.2020.08.026
    Medical exposure of the general population due to radiological investigations is the foremost source of all artificial ionising radiation. Here, we focus on a particular diagnostic radiological procedure, as only limited data are published with regard to radiation measurements during urethrograpic imaging. Specifically, this work seeks to estimate patient and occupational effective doses during urethrographic procedures at three radiology hospitals. Both staff and patient X-ray exposure levels were calculated in terms of entrance surface air kerma (ESAK), obtained by means of lithium fluoride thermoluminescent dosimeters (TLD-100(LiF:Mg:Cu.P)) for 243 urethrographic examinations. Patient radiation effective doses per procedure were estimated using conversion factors obtained from the use of Public Health England computer software. In units of mGy, the median and range of ESAK per examination were found to be 10.8 (3.6-26.2), 7.0 (0.2-32.3), and 24.3 (9.0-32.0) in Hospitals A, B, and C, respectively. The overall mean and range of staff doses (in µGy) were found to be 310 (4.0-1750) per procedure. With the exception of hospital C, the present evaluations of radiation dose have been found to be similar to those of previously published research. The wide range of patient and staff doses illustrate the need for radiation dose optimisation.
    Matched MeSH terms: X-Rays
  14. Alawiah A, Bauk S, Marashdeh MW, Nazura MZ, Abdul-Rashid HA, Yusoff Z, et al.
    Appl Radiat Isot, 2015 Oct;104:197-202.
    PMID: 26188687 DOI: 10.1016/j.apradiso.2015.07.011
    In regard to thermoluminescence (TL) applied to dosimetry, in recent times a number of researchers have explored the role of optical fibers for radiation detection and measurement. Many of the studies have focused on the specific dopant concentration, the type of dopant and the fiber core diameter, all key dependencies in producing significant increase in the sensitivity of such fibers. At doses of less than 1 Gy none of these investigations have addressed the relationship between dose response and TL glow peak behavior of erbium (Er)-doped silica cylindrical fibers (CF). For x-rays obtained at accelerating potentials from 70 to 130 kVp, delivering doses of between 0.1 and 0.7 Gy, present study explores the issue of dose response, special attention being paid to determination of the kinetic parameters and dosimetric peak properties of Er-doped CF. The effect of dose response on the kinetic parameters of the glow peak has been compared against other fiber types, revealing previously misunderstood connections between kinetic parameters and radiation dose. Within the investigated dose range there was an absence of supralinearity of response of the Er-doped silica CF, instead sub-linear response being observed. Detailed examination of glow peak response and kinetic parameters has thus been shown to shed new light of the rarely acknowledged issue of the limitation of TL kinetic model and sub-linear dose response of Er-doped silica CF.
    Matched MeSH terms: X-Rays
  15. Abdul Sani SF, Othman MHU, Alqahtani A, Almugren KS, Alkallas FH, Bradley DA
    PLoS One, 2020;15(12):e0241550.
    PMID: 33378398 DOI: 10.1371/journal.pone.0241550
    For x- and gamma- irradiations delivering entrance doses from 2- up to 1000 Gy to commercial 1.0 mm thick borosilicate glass microscope slides, study has been made of their thermoluminescence yield. With an effective atomic number of 10.6 (approximating bone equivalence), photon energy dependency is apparent in the low x-ray energy range, with interplay between the photoelectric effect and attenuation. As an example, over the examined dose range, at 120 kVp the photon sensitivity has been found to be some 5× that of 60Co gamma irradiations, also with repeatability to within ~1%. The glow-curves, taking the form of a single prominent broad peak, have been deconvolved yielding at best fit a total of five peaks, the associated activation energies and frequency factors also being obtained. The results indicate borosilicate glass slides to offer promising performance as a low-cost passive radiation dosimeter, with utility for both radiotherapy and industrial applications.
    Matched MeSH terms: X-Rays
  16. Moradi F, Ung NM, Khandaker MU, Mahdiraji GA, Saad M, Abdul Malik R, et al.
    Phys Med Biol, 2017 Jul 28;62(16):6550-6566.
    PMID: 28708603 DOI: 10.1088/1361-6560/aa7fe6
    The relatively new treatment modality electronic intraoperative radiotherapy (IORT) is gaining popularity, irradiation being obtained within a surgically produced cavity being delivered via a low-energy x-ray source and spherical applicators, primarily for early stage breast cancer. Due to the spatially dramatic dose-rate fall off with radial distance from the source and effects related to changes in the beam quality of the low keV photon spectra, dosimetric account of the Intrabeam system is rather complex. Skin dose monitoring in IORT is important due to the high dose prescription per treatment fraction. In this study, modeling of the x-ray source and related applicators were performed using the Monte Carlo N-Particle transport code. The dosimetric characteristics of the model were validated against measured data obtained using an ionization chamber and EBT3 film as dosimeters. By using a simulated breast phantom, absorbed doses to the skin for different combinations of applicator size (1.5-5 cm) and treatment depth (0.5-3 cm) were calculated. Simulation results showed overdosing of the skin (>30% of prescribed dose) at a treatment depth of 0.5 cm using applicator sizes larger than 1.5 cm. Skin doses were significantly increased with applicator size, insofar as delivering 12 Gy (60% of the prescribed dose) to skin for the largest sized applicator (5 cm diameter) and treatment depth of 0.5 cm. It is concluded that the recommended 0.5-1 cm distance between the skin and applicator surface does not guarantee skin safety and skin dose is generally more significant in cases with the larger applicators.

    HIGHLIGHTS: • Intrabeam x-ray source and spherical applicators were simulated and skin dose was calculated. • Skin dose for constant skin to applicator distance strongly depends on applicator size. • Use of larger applicators generally results in higher skin dose. • The recommended 0.5-1 cm skin to applicator distance does not guarantee skin safety.

    Matched MeSH terms: X-Rays
  17. Almugren KS, Sani SFA, Wandira R, Wahib N, Rozaila ZS, Khandaker MU, et al.
    Appl Radiat Isot, 2019 Sep;151:102-110.
    PMID: 31163392 DOI: 10.1016/j.apradiso.2019.04.027
    Present research concerns the TL signal stored in chalk of the variety commercially available for writing on blackboards. Samples of this have been subjected to x-ray irradiation, the key dosimetric parameters investigated including dose and energy response, sensitivity, fading and glow curve analysis. Three types of chalk have been investigated, each in five different colours. The samples were annealed at 323 K prior to irradiation. For all three chalk types and all five colours, the dose response has been found linear over the investigated dose range, 0-9 Gy. Regardless of type or colour, photoelectric energy dependency is apparent at the low energy end down to the lowest investigated accelerating potential of 30 kV. Crayola (Yellow) has shown the greatest TL sensitivity, thus selection has been made to limit further analysis to this medium alone, specifically in respect of glow curve and fading study. In addition, elemental compositional and structural change characterizations were made for the same medium, utilizing Energy Dispersive X-Ray (EDX) and Raman spectroscopy, respectively.
    Matched MeSH terms: X-Rays*
  18. Bushra A, Sulieman A, Edam A, Tamam N, Babikir E, Alrihaima N, et al.
    Appl Radiat Isot, 2023 Mar;193:110627.
    PMID: 36584412 DOI: 10.1016/j.apradiso.2022.110627
    Computed tomography is widely used for planar imaging. Previous studies showed that CR systems involve higher patient radiation doses compared to digital systems. Therefore, assessing the patient's dose and CR system performance is necessary to ensure that patients received minimal dose with the highest possible image quality. The study was performed at three medical diagnostic centers in Sudan: Medical Corps Hospital (MCH), Advance Diagnostic Center (ADC), and Advance Medical Center (AMC). The following tools were used in this study: Tape measure, Adhesive tape, 1.5 mm copper filtration (>10 × 10 cm), TO 20 threshold contrast test object, Resolution test object (e.g., Huttner 18), MI geometry test object or lead ruler, Contact mish, Piranha (semiconductor detector), Small lead or copper block (∼5 × 5 cm), and Steel ruler, to do a different type of tests (Dark Noise, Erasure cycle efficiency, Sensitivity Index calibration, Sensitivity Index consistency, Uniformity, Scaling errors, Blurring, Limiting spatial Resolution, Threshold, and Laser beam Function. Entrance surface air kerma (ESAK (mGy) was calculated from patient exposure parameters using DosCal software for three imaging modalities. A total of 199 patients were examined (112 chest X rays, 77 lumbar spine). The mean and standard deviation (sd) for patients ESAK (mGy) were 2.56 ± 0.1 mGy and 1.6 mGy for the Anteroposterior (AP) and lateral projections for the lumbar spine, respectively. The mean and sd for the patient's chest doses were 0.1 ± 0.01 for the chest X-ray procedures. The three medical diagnostic centers' CR system performance was evaluated and found that all of the three centers have good CR system functions. All the centers satisfy all the criteria of acceptable visual tests. CR's image quality and sensitivity were evaluated, and the CR image is good because it has good contrast and resolution. All the CR system available in the medical centers and upgraded from old X-ray systems to new systems, has been found to work well. The patient's doses were comparable for the chest X-ray procedures, while patients' doses from the lumbar spine showed variation up to 2 folds due to the variation in patients' weight and X-ray machine setting. Patients dose optimization is recommended to ensure the patients received a minimal dose while obtaining the diagnostic findings.
    Matched MeSH terms: X-Rays
  19. Chew MT, Nisbet A, Suzuki M, Matsufuji N, Murakami T, Jones B, et al.
    J Radiat Res, 2019 Jan 01;60(1):59-68.
    PMID: 30452663 DOI: 10.1093/jrr/rry081
    Glioblastoma (GBM), a Grade IV brain tumour, is a well-known radioresistant cancer. To investigate one of the causes of radioresistance, we studied the capacity for potential lethal damage repair (PLDR) of three altered strains of GBM: T98G, U87 and LN18, irradiated with various ions and various levels of linear energy transfer (LET). The GBM cells were exposed to 12C and 28Si ion beams with LETs of 55, 100 and 200 keV/μm, and with X-ray beams of 1.7 keV/μm. Mono-energetic 12C ions and 28Si ions were generated by the Heavy Ion Medical Accelerator at the National Institute of Radiological Science, Chiba, Japan. Clonogenic assays were used to determine cell inactivation. The ability of the cells to repair potential lethal damage was demonstrated by allowing one identical set of irradiated cells to repair for 24 h before subplating. The results show there is definite PLDR with X-rays, some evidence of PLDR at 55 keV/μm, and minimal PLDR at 100 keV/μm. There is no observable PLDR at 200 keV/μm. This is the first study, to the authors' knowledge, demonstrating the capability of GBM cells to repair potential lethal damage following charged ion irradiations. It is concluded that a GBM's PLDR is dependent on LET, dose and GBM strain; and the more radioresistant the cell strain, the greater the PLDR.
    Matched MeSH terms: X-Rays
  20. Hashim AN, Salleh MAAM, Sandu AV, Ramli MM, Yee KC, Mohd Mokhtar NZ, et al.
    Materials (Basel), 2021 Feb 05;14(4).
    PMID: 33562471 DOI: 10.3390/ma14040738
    The evolution of internal compressive stress from the intermetallic compound (IMC) Cu6Sn5 growth is commonly acknowledged as the key inducement initiating the nucleation and growth of tin (Sn) whisker. This study investigates the effect of Sn-0.7Cu-0.05Ni on the nucleation and growth of Sn whisker under continuous mechanical stress induced. The Sn-0.7Cu-0.05Ni solder joint has a noticeable effect of suppression by diminishing the susceptibility of nucleation and growth of Sn whisker. By using a synchrotron micro X-ray fluorescence (µ-XRF) spectroscopy, it was found that a small amount of Ni alters the microstructure of Cu6Sn5 to form a (Cu,Ni)6Sn5 intermetallic layer. The morphology structure of the (Cu,Ni)6Sn5 interfacial intermetallic layer and Sn whisker growth were investigated by scanning electron microscope (SEM) in secondary and backscattered electron imaging mode, which showed that there is a strong correlation between the formation of Sn whisker and the composition of solder alloy. The thickness of the (Cu,Ni)6Sn5 IMC interfacial layer was relatively thinner and more refined, with a continuous fine scallop-shaped IMC interfacial layer, and consequently enhanced a greater incubation period for the nucleation and growth of the Sn whisker. These verification outcomes proposes a scientifically foundation to mitigate Sn whisker growth in lead-free solder joint.
    Matched MeSH terms: X-Rays
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links