Displaying publications 41 - 60 of 86 in total

Abstract:
Sort:
  1. Chua EW, Maggo S, Kennedy MA
    Methods Mol Biol, 2017;1620:65-74.
    PMID: 28540699 DOI: 10.1007/978-1-4939-7060-5_3
    Polymerase chain reaction (PCR) is an oft-used preparatory technique in amplifying specific DNA regions for downstream analysis. The size of an amplicon was initially limited by errors in nucleotide polymerization and template deterioration during thermal cycling. A variant of PCR, designated long-range PCR, was devised to counter these drawbacks and enable the amplification of large fragments exceeding a few kb. In this chapter we describe a protocol for long-range PCR, which we have adopted to obtain products of 6.6, 7.2, 13, and 20 kb from human genomic DNA samples.
    Matched MeSH terms: Nucleic Acid Amplification Techniques/methods*
  2. Chin Kai Ling, Jaeyres Jani, Zainal Arifin Mustapha
    MyJurnal
    Introduction: Tuberculosis (TB), commonly caused by Mycobacterium tuberculosis (Mtb), is one of the ten leading causes of death worldwide. The gold standard, microbiological culture for detection and differentiation of mycobac-teria are time-consuming and laborious. The use of fast, easy and sensitive nucleic acid amplification tests (NAATs) for diagnosis of TB remains challenging because there is a high degree of homology within Mtb complex (MTBC) members and absence of target genes in the genome of some strains. This study aimed to identify new candidate genetic marker and to design specific primers to detect Mtb using in silico methods. Methods: Using Basic Local Alignment Search Tool (BLAST) program, Mtb H37Rv chromosome reference genome sequence was mapped with other MTBC members and a single nucleotide polymorphism (SNP) at Rv1970 was found to be specific only for Mtb strains. Mismatch amplification mutation assay (MAMA) combine with polymerase chain reaction (PCR) was used as an alternative method to detect the point mutation. MAMA primers targeting the SNP were designed using Primer-BLAST and the PCR assay was optimized via Taguchi method. Results: The assay amplified a 112 bp gene fragment and was able to detect all Mtb strains, but not the other MTBC members and non-tuberculous Mycobacte-ria. The detection limit of the assay was 60 pg/μl. Conclusion: Bioinformatics has provided predictive identification of many new target markers. The designed primers were found to be highly specific at single-gene target resolution for detection of Mtb.
    Matched MeSH terms: Nucleic Acid Amplification Techniques
  3. Azi Simon Onyema, Leslie Than Thian Lung, Suresh Kumar, Rukman Awang Hamat
    MyJurnal
    Introduction: Group A streptococcus (GAS) is responsible for high morbidity and mortality globally. Hence, the need to develop sensitive, reliable and cost- effective method of detection is crucial. In this study, we developed a visual detection method for the common virulence gene, streptococcal pyrogenic exotoxin B (speB) involved in invasive GAS diseases using loop-mediated isothermal amplification (LAMP) with fluorescent detection dye (calcein). Meth-ods: The LAMP reaction was optimized at 63°C for 35 minutes using five sets of primer designed with LAMP primer V5 software. When the dye was added prior to amplification, samples with speB DNA developed a characteristic green color after the reaction, but no color reactions were observed in samples with DNAs of non-GAS isolates. De-tection of speB by LAMP assay was done among 43 clinical isolates of blood, pus, wound, tissue and throat samples and ATCCs for controls. Our findings were further reconfirmed by subjecting the LAMP products to 0.5% gel electro-phoresis. Results: The detection limit of this LAMP assay for speB was 10-7 ng/μl of genomic DNA per reaction, which was 10,000-fold more sensitive than conventional PCR 10-3 ng/μl. All 100 % samples were positive for speB gene by LAMP, and 93% by conventional PCR method. Conclusion: LAMP assay could offer remarkably high sensitivity, specificity, repeatability, reliability, affordability, and visibility; it is appropriate for rapid detection of speB in Group A streptococci (GAS) as a point of care testing.
    Matched MeSH terms: Nucleic Acid Amplification Techniques
  4. Lau YL, Fong MY, Mahmud R, Chang PY, Palaeya V, Cheong FW, et al.
    Malar J, 2011;10:197.
    PMID: 21774805 DOI: 10.1186/1475-2875-10-197
    The emergence of Plasmodium knowlesi in humans, which is in many cases misdiagnosed by microscopy as Plasmodium malariae due to the morphological similarity has contributed to the needs of detection and differentiation of malaria parasites. At present, nested PCR targeted on Plasmodium ssrRNA genes has been described as the most sensitive and specific method for Plasmodium detection. However, this method is costly and requires trained personnel for its implementation. Loop-mediated isothermal amplification (LAMP), a novel nucleic acid amplification method was developed for the clinical detection of P. knowlesi. The sensitivity and specificity of LAMP was evaluated in comparison to the results obtained via microscopic examination and nested PCR.
    Matched MeSH terms: Nucleic Acid Amplification Techniques/methods*
  5. Britton S, Cheng Q, Sutherland CJ, McCarthy JS
    Malar J, 2015;14:335.
    PMID: 26315027 DOI: 10.1186/s12936-015-0848-3
    To detect all malaria infections in elimination settings sensitive, high throughput and field deployable diagnostic tools are required. Loop-mediated isothermal amplification (LAMP) represents a possible field-applicable molecular diagnostic tool. However, current LAMP platforms are limited by their capacity for high throughput.
    Matched MeSH terms: Nucleic Acid Amplification Techniques/methods*
  6. Selvarajah D, Naing C, Htet NH, Mak JW
    Malar J, 2020 Jun 19;19(1):211.
    PMID: 32560728 DOI: 10.1186/s12936-020-03283-9
    BACKGROUND: The global malaria decline has stalled and only a few countries are pushing towards pre-elimination. The aim of the malaria elimination phase is interruption of local transmission of a specified malaria parasite in a defined geographical area. New and improved screening tools and strategies are required for detection and management of very low-density parasitaemia in the field. The objective of this study was to synthesize evidence on the diagnostic accuracy of loop-mediated isothermal amplification (LAMP) test for the detection of malaria parasites among people living in endemic areas.

    METHODS: This study adhered to the Preferred Reporting Items for Systematic Reviews and Meta-Analysis for Diagnostic Test Accuracy (PRISMA-DTA) guideline. Relevant studies in the health-related electronic databases were searched. According to the criteria set for this study, eligible studies were identified. The quality of included studies was evaluated with the use of a quality assessment checklist. A summary performance estimates such as pooled sensitivity and specificity were stratified by type of LAMP. Bivariate model for data analyses was applied. Summary receiver operating characteristics plots were created to display the results of individual studies in a receiver operating characteristics space. Meta-regression analysis was performed to investigate the sources of heterogeneity among individual studies.

    RESULTS: Twenty-seven studies across 17 endemic countries were identified. The vast majority of studies were with unclear risk of bias in the selection of index test. Overall, the pooled test performances were high for Pan LAMP (sensitivity: 0.95, 95% CI 0.91 to 0.97; specificity: 0.98, 95% CI 0.95 to 0.99), Plasmodium falciparum (Pf) LAMP (sensitivity: 0.96, 95% CI 0.94 to 0.98; specificity: 0.99, 95% CI 0.96 to 1.00) or for Plasmodium vivax (Pv) LAMP from 6 studies (sensitivity: 0.98, 95% CI 0.92 to 0.99; specificity: 0.99, 95% CI 0.72 to 1.00). The area under the curve for Pan LAMP (0.99, 95% CI 0.98-1.00), Pf LAMP (0.99, 95% CI 0.97-0.99) and Pv LAMP was (1.00, 95% CI 0.98-1.00) indicated that the diagnostic performance of these tests were within the excellent accuracy range. Meta-regression analysis showed that sample size had the greatest impact on test performance, among other factors.

    CONCLUSIONS: The current findings suggest that LAMP-based assays are appropriate for detecting low-level malaria parasite infections in the field and would become valuable tools for malaria control and elimination programmes. Future well-designed larger sample studies on LAMP assessment in passive and active malaria surveillances that use PCR as the reference standard and provide sufficient data to construct 2 × 2 diagnostic table are needed.

    Matched MeSH terms: Nucleic Acid Amplification Techniques/methods*
  7. Piera KA, Aziz A, William T, Bell D, González IJ, Barber BE, et al.
    Malar J, 2017 01 13;16(1):29.
    PMID: 28086789 DOI: 10.1186/s12936-016-1676-9
    BACKGROUND: Plasmodium knowlesi is the most common cause of malaria in Malaysia. However, microscopic diagnosis is inaccurate and rapid diagnostic tests (RDTs) are insufficiently sensitive. PCR is sensitive and specific but not feasible at a district level. Loop-mediated isothermal amplification (LAMP) shows potential with only basic requirements. A commercially available LAMP assay, the Eiken Loopamp™ MALARIA Pan Detection kit, is sensitive for Plasmodium falciparum and Plasmodium vivax, but has not previously been evaluated for P. knowlesi. This study aims to determine the sensitivity of this LAMP assay for detecting P. knowlesi infection.

    METHODS: Study participants included 73 uncomplicated malaria patients with PCR species confirmation: 50 P. knowlesi, 20 P. falciparum and 3 P. vivax. Nineteen malaria-negative, non-endemic area controls were also included. The sensitivity of the Eiken Loopamp™ MALARIA Pan Detection kit (Pan LAMP) for detecting each Plasmodium species was evaluated. Sensitivity and specificity of the Eiken Loopamp™ MALARIA Pf Detection kit (Pf LAMP) for P. falciparum were also determined. The limit of detection for each LAMP assay was evaluated, with results compared to PCR. All P. knowlesi patients were also tested by CareStart™ (Pf/VOM) and OptiMAL-IT™ (Pan/Pf) RDTs.

    RESULTS: The sensitivity of the Pan LAMP assay was 100% for P. knowlesi (95% CI 92.9-100), P. falciparum (95% CI 83.2-100), and P. vivax (95% CI 29.2-100). The Pf LAMP was 100% sensitive and specific for P. falciparum detection, with all P. knowlesi samples having a negative reaction. LAMP sensitivity was superior to both RDTs, with only 10 and 28% of P. knowlesi samples testing positive to CareStart™ and OptiMAL-IT™, respectively. Limit of detection using the Pan LAMP for both P. knowlesi and P. vivax was 2 parasites/μL, comparable to PCR. For P. falciparum both the Pan LAMP and Pf LAMP demonstrated a limit of detection of 20 parasites/μL.

    CONCLUSIONS: The Eiken Loopamp™ MALARIA Pan Detection kit is sensitive for detection of P. knowlesi in low parasitaemia clinical infections, as well as P. falciparum and P. vivax. However, a P. knowlesi-specific field assay in a simpler format would assist correct species identification and initiation of optimal treatment for all malaria patients.

    Matched MeSH terms: Nucleic Acid Amplification Techniques/methods*
  8. Yon JLT, Htet NH, Naing C, Tung WS, Aung HH, Mak JW
    Malar J, 2022 Dec 22;21(1):391.
    PMID: 36550507 DOI: 10.1186/s12936-022-04419-9
    BACKGROUND: Due to relatively low malaria parasitaemia in pregnancy, an appropriate field test that can adequately detect infections in pregnant women presenting with illness or for malaria screening during antenatal care is crucially important. The objective was to evaluate the diagnostic accuracy of loop-mediated isothermal amplification (LAMP) for the detection of uncomplicated malaria in pregnancy.

    METHODS: This was a meta-analysis of diagnostic accuracy. Relevant studies that assessed the diagnostic performance of LAMP for the detection of malaria in pregnancy were searched in health-related electronic databases including PubMed, Ovid, and Google Scholar. The methodological quality of the studies included was evaluated using the QUADAS-2 tool.

    RESULTS: Of the 372 studies identified, eight studies involving 2999 pregnant women in five endemic countries that assessed the accuracy of LAMP were identified. With three types of PCR as reference tests, the pooled sensitivity of LAMP was 91% (95%CI 67-98%) and pooled specificity was 99% (95%CI 83-100%, 4 studies), and the negative likelihood ratio was 9% (2-40%). Caution is needed in the interpretation as there was substantial between-study heterogeneity (I2: 80%), and a low probability that a person without infection is tested negative. With microscopy as a reference, the pooled sensitivity of LAMP was 95% (95%CI 26-100%) and pooled specificity was 100% (95%CI 94-100%, 4 studies). There was a wide range of sensitivity and substantial between-study heterogeneity (I2: 83.5-98.4%). To investigate the source of heterogeneity, a meta-regression analysis was performed with covariates. Of these potential confounding factors, reference test (p: 0.03) and study design (p:0.03) had affected the diagnostic accuracy of LAMP in malaria in pregnancy. Overall, there was a low certainty of the evidence in accuracy estimates.

    CONCLUSION: The findings suggest that LAMP is more sensitive than traditional tests used at facilities, but the utility of detecting and treating these low-density infections is not well understood. Due to the limited number of studies with bias in their methodological quality, variation in the study design, and different types of reference tests further research is likely to change the estimate. Well-conceived large prospective studies with blinding of the index test results are recommenced.

    Matched MeSH terms: Nucleic Acid Amplification Techniques/methods
  9. Lai MY, Ooi CH, Lau YL
    Malar J, 2021 Mar 25;20(1):166.
    PMID: 33766038 DOI: 10.1186/s12936-021-03707-0
    BACKGROUND: As an alternative to PCR methods, LAMP is increasingly being used in the field of molecular diagnostics. Under isothermal conditions at 65 °C, the entire procedure takes approximately 30 min to complete. In this study, we establish a sensitive and visualized LAMP method in a closed-tube system for the detection of Plasmodium knowlesi.

    METHODS: A total of 71 malaria microscopy positive blood samples collected in blood spots were obtained from the Sarawak State Health Department. Using 18s rRNA as the target gene, nested PCR and SYBR green I LAMP assay were performed following the DNA extraction. The colour changes of LAMP end products were observed by naked eyes.

    RESULTS: LAMP assay demonstrated a detection limit of 10 copies/µL in comparison with 100 copies/µL nested PCR. Of 71 P. knowlesi blood samples collected, LAMP detected 69 microscopy-positive samples. LAMP exhibited higher sensitivity than nested PCR assay. The SYBR green I LAMP assay was 97.1% sensitive (95% CI 90.2-99.7%) and 100% specific (95% CI 83.2-100%). Without opening the cap, incorporation of SYBR green I into the inner cap of the tube enabled the direct visualization of results upon completion of amplification. The positives instantaneously turned green while the negatives remained orange.

    CONCLUSIONS: These results indicate that SYBR green I LAMP assay is a convenient diagnosis tool for the detection of P. knowlesi in remote settings.

    Matched MeSH terms: Nucleic Acid Amplification Techniques/instrumentation*
  10. Tan le V, Tuyen NT, Thanh TT, Ngan TT, Van HM, Sabanathan S, et al.
    J Virol Methods, 2015 Apr;215-216:30-6.
    PMID: 25704598 DOI: 10.1016/j.jviromet.2015.02.011
    Enterovirus A71 (EV-A71) has emerged as the most important cause of large outbreaks of severe and sometimes fatal hand, foot and mouth disease (HFMD) across the Asia-Pacific region. EV-A71 outbreaks have been associated with (sub)genogroup switches, sometimes accompanied by recombination events. Understanding EV-A71 population dynamics is therefore essential for understanding this emerging infection, and may provide pivotal information for vaccine development. Despite the public health burden of EV-A71, relatively few EV-A71 complete-genome sequences are available for analysis and from limited geographical localities. The availability of an efficient procedure for whole-genome sequencing would stimulate effort to generate more viral sequence data. Herein, we report for the first time the development of a next-generation sequencing based protocol for whole-genome sequencing of EV-A71 directly from clinical specimens. We were able to sequence viruses of subgenogroup C4 and B5, while RNA from culture materials of diverse EV-A71 subgenogroups belonging to both genogroup B and C was successfully amplified. The nature of intra-host genetic diversity was explored in 22 clinical samples, revealing 107 positions carrying minor variants (ranging from 0 to 15 variants per sample). Our analysis of EV-A71 strains sampled in 2013 showed that they all belonged to subgenogroup B5, representing the first report of this subgenogroup in Vietnam. In conclusion, we have successfully developed a high-throughput next-generation sequencing-based assay for whole-genome sequencing of EV-A71 from clinical samples.
    Matched MeSH terms: Nucleic Acid Amplification Techniques/methods*
  11. Thanarajoo SS, Kong LL, Kadir J, Lau WH, Vadamalai G
    J Virol Methods, 2014 Jun;202:19-23.
    PMID: 24631346 DOI: 10.1016/j.jviromet.2014.02.024
    A reverse transcription loop-mediated isothermal amplification (RT-LAMP) detected Coconut cadang-cadang viroid (CCCVd) within 60 min at 60 °C in total nucleic acid extracted from oil palm leaves infected with CCCVd. Positive reactions showed colour change from orange to green in the reaction mix after the addition of fluorescent reagent, and a laddering pattern band on 2% agarose gel electrophoresis. Conventional RT-PCR with LAMP primers produced amplicons with a sequence identical to the 297-nt CCCVd oil palm variant with the primers being specific for CCCVd and not for other viroids such as PSTVd and CEVd. RT-LAMP was found to be rapid and specific for detecting oil palm CCCVd.
    Matched MeSH terms: Nucleic Acid Amplification Techniques/methods*
  12. Lau YL, Meganathan P, Sonaimuthu P, Thiruvengadam G, Nissapatorn V, Chen Y
    J Clin Microbiol, 2010 Oct;48(10):3698-702.
    PMID: 20660217 DOI: 10.1128/JCM.00462-10
    Loop-mediated isothermal amplification (LAMP), a rapid nucleic acid amplification method, was developed for the clinical diagnosis of toxoplasmosis. Three LAMP assays based on the SAG1, SAG2, and B1 genes of Toxoplasma gondii were developed. The sensitivities and specificities of the LAMP assays were evaluated by comparison with the results of conventional nested PCR. The LAMP assays were highly sensitive and had a detection limit of 0.1 tachyzoite, and no cross-reactivity with the DNA of other parasites was observed. Blood was collected from 105 individuals to test the LAMP assays: 40 patients with active toxoplasmosis, 40 negative controls, and 25 patients with other parasitic infections. The SAG2-based LAMP (SAG2-LAMP) had a greater sensitivity (87.5%) than the SAG1-LAMP (80%), B1-LAMP (80%), and nested PCR (62.5%). All the LAMP assays and nested PCR were 100% specific. This is the first report of a study which applied the LAMP method to diagnose toxoplasmosis from human blood samples. Due to its simplicity, sensitivity, and specificity, LAMP is suggested as an appropriate method for routine diagnosis of active toxoplasmosis in humans.
    Matched MeSH terms: Nucleic Acid Amplification Techniques/methods*
  13. Wong YP, Othman S, Lau YL, Radu S, Chee HY
    J Appl Microbiol, 2018 Mar;124(3):626-643.
    PMID: 29165905 DOI: 10.1111/jam.13647
    Loop-mediated isothermal amplification (LAMP) amplifies DNA with high specificity, efficiency and rapidity under isothermal conditions by using a DNA polymerase with high displacement strand activity and a set of specifically designed primers to amplify targeted DNA strands. Following its first discovery by Notomi et al. ( Nucleic Acids Res 28: E63), LAMP was further developed over the years which involved the combination of this technique with other molecular approaches, such as reverse transcription and multiplex amplification for the detection of infectious diseases caused by micro-organisms in humans, livestock and plants. In this review, available types of LAMP techniques will be discussed together with their applications in detection of various micro-organisms. Up to date, there are varieties of LAMP detection methods available including colorimetric and fluorescent detection, real-time monitoring using turbidity metre and detection using lateral flow device which will also be highlighted in this review. Apart from that, commercialization of LAMP technique had also been reported such as lyophilized form of LAMP reagents kit and LAMP primer sets for detection of pathogenic micro-organisms. On top of that, advantages and limitations of this molecular detection method are also described together with its future potential as a diagnostic method for infectious disease.
    Matched MeSH terms: Nucleic Acid Amplification Techniques/methods*
  14. Qiao Z, Xue L, Sun M, Ma N, Shi H, Yang W, et al.
    J Agric Food Chem, 2024 Jan 10;72(1):857-864.
    PMID: 38134022 DOI: 10.1021/acs.jafc.3c07582
    Salmonellosis continues to impose a significant economic burden globally. Rapid and sensitive detection of Salmonella is crucial to preventing the outbreaks of foodborne illnesses, yet it remains a formidable challenge. Herein, a dual-functional tetrahedron multivalent aptamer assisted amplification-free CRISPR/Cas12a assay was developed for Salmonella detection. In the system, the aptamer was programmatically assembled on the tetrahedral DNA nanostructure to fabricate a multivalent aptamer (TDN-multiApt), which displayed a 3.5-fold enhanced avidity over the monovalent aptamer and possessed four CRISPR/Cas12a targeting fragments to amplify signal. Therefore, TDN-multiApt could directly activate Cas12a to achieve the second signal amplification without any nucleic acid amplification. By virtue of the synergism of high avidity and cascaded signal amplifications, the proposed method allowed the ultrasensitive detection of Salmonella as low as 7 cfu mL-1. Meanwhile, this novel platform also exhibited excellent specificity against target bacteria and performed well in the detection of various samples, indicating its potential application in real samples.
    Matched MeSH terms: Nucleic Acid Amplification Techniques
  15. Fauzi FH, Hamzan NI, Rahman NA, Suraiya S, Mohamad S
    J Zhejiang Univ Sci B, 2021 4 13;21(12):961-976.
    PMID: 33843162 DOI: 10.1631/jzus.B2000161
    Worldwide there has been a significant increase in the incidence of oropharyngeal squamous cell carcinoma (OPSCC) etiologically attributed to oncogenic human papillomavirus (HPV). Reliable and accurate identification and detection tools are important as the incidence of HPV-related cancer is on the rise. Several HPV detection methods for OPSCC have been developed and each has its own advantages and disadvantages in regard to sensitivity, specificity, and technical difficulty. This review summarizes our current knowledge of molecular methods for detecting HPV in OPSCC, including HPV DNA/RNA polymerase chain reaction (PCR), loop-mediated isothermal amplification (LAMP), p16 immunohistochemistry (IHC), and DNA/RNA in situ hybridization (ISH) assays. This summary may facilitate the selection of a suitable method for detecting HPV infection, and therefore may help in the early diagnosis of HPV-related carcinoma to reduce its mortality, incidence, and morbidity.
    Matched MeSH terms: Nucleic Acid Amplification Techniques
  16. Lai MY, Bukhari FDM, Zulkefli NZ, Ismail I, Mustapa NI, Soh TST, et al.
    Int J Infect Dis, 2022 Jul;120:132-134.
    PMID: 35472524 DOI: 10.1016/j.ijid.2022.04.036
    OBJECTIVES: Preventing reverse transcription loop-mediated isothermal amplification (RT-LAMP) carryover contamination could be solved by adding deoxyuridine triphosphate (dUTP) and uracil-DNA glycosylase (UDG) into the reaction master mix.

    METHODS: RNA was extracted from nasopharyngeal swab samples by a simple RNA extraction method.

    RESULTS: Testing of 77 samples demonstrated 91.2% sensitivity (95% confidence interval [CI]: 78-98.2%) and 100% specificity (95% confidence interval: 92-100%) using UDG RT-LAMP.

    CONCLUSION: This colorimetric UDG RT-LAMP is a simple-to-use, fast, and easy-to-interpret method, which could serve as an alternative for diagnosis of SARS-CoV-2 infection, especially in remote hospitals and laboratories with under-equipped medical facilities.

    Matched MeSH terms: Nucleic Acid Amplification Techniques/methods
  17. Jasbeer, K., Son, R., Mohamad Ghazali, F., Cheah, Y.K.
    MyJurnal
    Successful DNA amplification is vital for the detection of specific DNA targets in feeds, and this in return depends on the ability of DNA extraction methods to produce good quality DNA. In this study, seven methods were compared for DNA extraction from feeds using quantitative polymerase chain reaction (PCR) of single copy maize (Zea mays) endogenous hmg (high mobility group) gene. Relative levels of hmg were used to evaluate the DNA quality. Spectrophotometer determination of DNA was also carried out to assess DNA yield and DNA purity, while electrophoretic analysis of genomic DNA extracts was carried out to investigate DNA integrity. The findings illustrate that the DNA extraction methods have a significant effect on DNA quality. Statistically, the Epicentre method extracted the highest DNA yield while the Wizard method had the lowest DNA yield with high DNA purity and integrity. However, the Wizard method recovered the most amplifiable DNA per reaction, indicating that template quality and integrity had greater influence over hmg amplification than DNA yield.
    Matched MeSH terms: Nucleic Acid Amplification Techniques
  18. Obande GA, Banga Singh KK
    Infect Drug Resist, 2020;13:455-483.
    PMID: 32104017 DOI: 10.2147/IDR.S217571
    Nucleic acid amplification technology (NAAT) has assumed a critical position in disease diagnosis in recent times and contributed significantly to healthcare. Application of these methods has resulted in a more sensitive, accurate and rapid diagnosis of infectious diseases than older traditional methods like culture-based identification. NAAT such as the polymerase chain reaction (PCR) is widely applied but seldom available to resource-limited settings. Isothermal amplification (IA) methods provide a rapid, sensitive, specific, simpler and less expensive procedure for detecting nucleic acid from samples. However, not all of these IA techniques find regular applications in infectious diseases diagnosis. Disease diagnosis and treatment could be improved, and the rapidly increasing problem of antimicrobial resistance reduced, with improvement, adaptation, and application of isothermal amplification methods in clinical settings, especially in developing countries. This review centres on some isothermal techniques that have found documented applications in infectious diseases diagnosis, highlighting their principles, development, strengths, setbacks and imminent potentials for use at points of care.
    Matched MeSH terms: Nucleic Acid Amplification Techniques
  19. Wong CL, Yong CY, Ong HK, Ho KL, Tan WS
    Front Vet Sci, 2020;7:477.
    PMID: 32974392 DOI: 10.3389/fvets.2020.00477
    Foot-and-mouth disease (FMD) is a devastating livestock disease caused by foot-and-mouth disease virus (FMDV). Outbreaks of this disease in a country always result in conspicuous economic losses to livestock industry and subsequently lead to serious socioeconomic damages due to the immediate imposition of trade embargo. Rapid and accurate diagnoses are imperative to control this infectious virus. In the current review, enzyme-linked immunosorbent assay (ELISA)-based methods used in FMD diagnosis are extensively reviewed, particularly the sandwich, liquid-phase blocking, and solid-phase competition ELISA. The differentiation of infected animals from vaccinated animals using ELISA-based methods is also highlighted, in which the role of 3ABC polyprotein as a marker is reviewed intensively. Recently, more studies are focusing on the molecular diagnostic methods, which detect the viral nucleic acids based on reverse transcription-polymerase chain reaction (RT-PCR) and RT-loop-mediated isothermal amplification (RT-LAMP). These methods are generally more sensitive because of their ability to amplify a minute amount of the viral nucleic acids. In this digital era, the RT-PCR and RT-LAMP are progressing toward the mobile versions, aiming for on-site FMDV diagnosis. Apart from RT-PCR and RT-LAMP, another diagnostic assay specifically designed for on-site diagnosis is the lateral flow immunochromatographic test strips. These test strips have some distinct advantages over other diagnostic methods, whereby the assay often does not require the aid of an external device, which greatly lowers the cost per test. In addition, the on-site diagnostic test can be easily performed by untrained personnel including farmers, and the results can be obtained in a few minutes. Lastly, the use of FMDV diagnostic assays for progressive control of the disease is also discussed critically.
    Matched MeSH terms: Nucleic Acid Amplification Techniques
  20. Chang YM, Swaran Y, Phoon YK, Sothirasan K, Sim HT, Lim KB, et al.
    Forensic Sci Int Genet, 2009 Jun;3(3):e77-80.
    PMID: 19414156 DOI: 10.1016/j.fsigen.2008.07.007
    17 Y-STRs (DYS456, DYS389I, DYS390, DYS389II, DYS458, DYS19, DYS385a/b, DYS393, DYS391, DYS439, DYS635 or Y-GATA C4, DYS392, Y-GATA H4, DYS437, DYS438 and DYS448) have been analyzed in 320 male individuals from Sarawak, an eastern state of Malaysia on the Borneo island using the AmpFlSTR Y-filer (Applied Biosystems, Foster City, CA). These individuals were from three indigenous ethnic groups in Sarawak comprising of 103 Ibans, 113 Bidayuhs and 104 Melanaus. The observed 17-loci haplotypes and the individual allele frequencies for each locus were estimated, whilst the locus diversity, haplotype diversity and discrimination capacity were calculated in the three groups. Analysis of molecular variance (AMOVA) indicated that 87.6% of the haplotypic variation was found within population and 12.4% between populations (fixation index F(ST)=0.124, p=0.000). This study has revealed that the indigenous populations in Sarawak are distinctly different to each other, and to the three major ethnic groups in Malaysia (Malays, Chinese and Indians), with the Melanaus having a strikingly high degree of shared haplotypes within. There are rare unusual variants and microvariants that were not present in Malaysian Malay, Chinese or Indian groups. In addition, occurrences of DYS385 duplications which were only noticeably present in Chinese group previously was also observed in the Iban group whilst null alleles were detected at several Y-loci (namely DYS19, DYS392, DYS389II and DYS448) in the Iban and Melanau groups.
    Matched MeSH terms: Nucleic Acid Amplification Techniques