STUDY DESIGN: Observational, cross-sectional study.
PLACE AND DURATION OF STUDY: Orthodontic Department of Baqai Medical University, Karachi, Pakistan, from August to October 2013.
METHODOLOGY: Atotal of 209 pre-treatment lateral cephalometric radiographs of orthodontic patients were selected from departmental records, comprised of 92 males and 117 females. Radiographs were traced for measurements of ANB, Wits appraisal, Beta-angle, W-angle and Yen-angle. Patients were categorized into skeletal classes I, II, and III on the basis of performed measurements, incisor classification, and profile recorded from their records. Descriptive analysis was used to obtain median interquartile range in both the genders and Mann-Whitney U-test was used to observe gender dimorphism.
RESULTS: Skeletal class II was the most prevalent type of malocclusion. There were no difference in the obtained measurements between males and females except the Wits appraisal and Beta-angle in class II patients, which showed significant difference in values (p < 0.05).
CONCLUSION: Pakistani population has no significant different difference in the craniofacial morphology of males and females, with the exception of Wits-appraisal and Beta-angle in class II cases.
METHODS: Graphite furnace atomic absorption spectrometry (GF-AAS) was used to evaluate six digestion methods, (1) nitric acid, (2) nitric acid overnight, (3) nitric acid-hydrogen peroxide, (4) nitric-perchloric acid, (5) sulfuric acid, and (6) dry ashing, to determine the most suitable digestion method for the determination of heavy metals in the samples.
RESULTS: The concentration ranges of Cd, Pb, As and Se in fresh tea leaves were from 0.03-0.13, 0.19-2.06 and 0.47-1.31 µg/g, respectively while processed tea contained heavy metals at different concentrations: Cd (0.04-0.16 µg/g), Cr (0.45-10.73 µg/g), Pb (0.07-1.03 µg/g), As (0.89-1.90 µg/g) and Se (0.21-10.79 µg/g). Moreover, the soil samples of tea plantations also showed a wide range of concentrations: Cd (0.11-0.45 µg/g), Pb (2.80-66.54 µg/g), As (0.78-4.49 µg/g), and Se content (0.03-0.99 µg/g). Method no. 2 provided sufficient time to digest the tea matrix and was the most efficient method for recovering Cd, Cr, Pb, As and Se. Methods 1 and 3 were also acceptable and can be relatively inexpensive, easy and fast. The heavy metal transfer factors in the investigated soil/tea samples decreased as follows: Cd > As > Se > Pb.
CONCLUSION: Overall, the present study gives current insights into the heavy metal levels both in soils and teas commonly consumed in Bangladesh.
MATERIALS AND METHODS: 100 smokers and 100 nonsmokers ages 18-50 years were recruited for this study in Kota Bharu, Malaysia. Oral hygiene (good/fair vs poor) was determined using the Simplified Oral Hygiene Index, and the halitosis level was measured using a Halimeter. Subjects were instructed to refrain from consuming foods containing garlic, onions, strong spices, alcohol and using mouthwashes 48 h prior to the examination. The halitosis levels were quantified by recording volatile sulphur compounds (VSCs) three times at 3-min intervals, resulting in a mean halitosis score. Various statistical analyses were performed, ranging from simple frequency analysis to multivariable modelling.
RESULTS: The proportions of subjects with poor oral hygiene and high halitosis were 24.0% and 41.5%, respectively. According to bivariate analyses, both problems were significantly less frequent among younger adults (halitosis), females, subjects with higher education, those with adequate habits to maintain good oral hygiene, those who had recent dental visits and those self-reporting fewer health problems. The percentages of poor oral hygiene and high halitosis were significantly higher in smokers (p < 0.001). However, almost all these variables failed to show significance in the multivariate analyses, with the exceptions of smoking for both poor oral hygiene and halitosis, education for poor oral hygiene, and age, self-reported health problems and time since the previous dental visit for halitosis.
CONCLUSION: These findings demonstrate a significantly higher level of halitosis and poorer oral hygiene in smokers than nonsmokers.
DESIGN: A digitally derived 3-dimensional maxillary model incorporating the palatal defect was generated from the patient's existing cone beam computerized tomography data and compared with the scanned cast from the conventional impression for linear dimensions, area, and volume. The digitally derived cast was 3-dimensionally printed and the obturator fabricated using traditional techniques. Similarly, an obturator was fabricated from the conventional cast and the fit of both final obturator bulbs were compared in vivo.
RESULTS: The digitally derived model produced more accurate volumes and surface areas within the defect. The defect margins and peripheries were overestimated which was reflected clinically.
CONCLUSION: The digitally derived model provided advantages in the fabrication of the palatal obturator; however, further clinical research is required to refine consistency.
PURPOSE: The purpose of this in vitro study was to evaluate the SR, tensile strength (TS), and percentage elongation (% E) of different SEs subjected to outdoor weathering in the Malaysian climate.
MATERIAL AND METHODS: Type-II dumbbell-shaped specimens (N-120) (nonweathered=15, weathered=15) were made from 3 room-temperature vulcanized (A-2000, A-2006, and A-103) and 1 heat-temperature vulcanized (M-511) silicone (Factor II). For 6 months, weathered specimens were subjected to outdoor weathering inside a custom exposure rack. Simultaneously, the nonweathered specimens were kept in a dehumidifier. Subsequently, the SR was measured with a profilometer; TS and % E were measured by using a universal testing machine. Two-way ANOVA was used to compare the means of the tested properties of the nonweathered and weathered specimens, and pairwise comparison was carried out between the silicones (α=.05).
RESULTS: After outdoor weathering, the SR, TS, and % E were adversely affected by weathering in the Malaysian environment. Among the silicone materials, A-2000 showed the least TS changes (2.51 MPa), while A-2006 demonstrated significant changes in percentage elongation after outdoor weathering (266.5%). M-511 exhibited the highest mean value (2.50 μm) for SR changes. In addition, A-103 SE showed statistically significant differences in most pairwise comparisons for all 3 dependent variables.
CONCLUSIONS: Based on the evaluation of mechanical properties, A-103 can be suggested as a suitable silicone for maxillofacial prostheses fabricated for tropical climates. However, A-2000 can be a suitable alternative, although significant changes to surface roughness were detected after outdoor weathering.
Methods: A total of eighteen (18) malocclusion patients were identified. Malocclusion patients were subdivided into 3 groups based on the bracket selection (conventional, self-ligating, and ceramic bracket) with 6 patients for each group. sEMG of muscles were done using a two-channel electromyography device, where pregelled and self-adhesive electrodes (bilateral) were applied. Chewing and clenching of masseter and temporalis muscle activity were recorded for 20 s pre and 6 months of orthodontic treatment using sEMG (frequency 60 Hz). The data were analysed by using repeated measures ANOVA in IBM SPSS Statistics Version 24.0.
Results: Chewing and clenching for masseter muscle showed no significant difference (P > 0.05) in sEMG activity of three types of the brackets. However, for temporalis muscle, there was a significant difference found in sEMG activity during chewing (P < 0.05) and clenching (P < 0.05) between these three brackets.
Conclusion: The activity of temporalis muscle showed significant changes in chewing and clenching, where the conventional group demonstrated better muscle activity pre and at six months of fixed appliances.
METHOD: Medical image data for five types of defects were selected, segmented, converted and decimated to 3D polygon models on a personal computer. The models were transferred to a computer aided design (CAD) software which aided in designing the prosthesis according to the virtual models. Two templates were designed for each defect, one by an OS (free) system and one by CS. The parameters for analyses were the virtual volume, Dice similarity coefficient (DSC) and Hausdorff's distance (HD) and were executed by the OS point cloud comparison tool.
RESULT: There was no significant difference (p > 0.05) between CS and OS when comparing the volume of the template outputs. While HD was within 0.05-4.33 mm, evaluation of the percentage similarity and spatial overlap following the DSC showed an average similarity of 67.7% between the two groups. The highest similarity was with orbito-facial prostheses (88.5%) and the lowest with facial plate prosthetics (28.7%).
CONCLUSION: Although CS and OS pipelines are capable of producing templates which are aesthetically and volumetrically similar, there are slight comparative discrepancies in the landmark position and spatial overlap. This is dependent on the software, associated commands and experienced decision-making. CAD-based templates can be planned on current personal computers following appropriate decimation.
OBJECTIVE: This study was intended to assess the knowledge and attitude towards OSA and compare it among dental and medical undergraduate students of University Sains Malaysia (USM).
METHODS: In this study, a total of 216 clinical undergraduate students (36 from each year; 108 from medical and 108 from dental school) of University Sains Malaysia (USM) Health campus were recruited for the study by non-probability stratified random sampling method. Total study period was October 2017 to October 2018. A self-administered questionnaire was used to assess the sociodemographic status and OSAKA questionnaire was used to assess knowledge and attitude regarding sleep apnoea of the respondents. Descriptive analysis was carried out to assess the knowledge and attitude of OSA amongst dental and medical undergraduate students of USM. The Mann-Whitney U test was carried out to compare the knowledge and attitude of OSA amongst dental and medical undergraduate students of USM.
RESULTS: Our study findings revealed that 0.9 %and 6.5 %of the dental undergraduate students and medical undergraduate students could answer all the questions correctly regarding knowledge of OSA. Based on the assessment of the difference between medical and dental students in terms of knowledge towards OSA patients, significant difference was observed at the significance level of 95%, where p
Methods: Twenty-two patients (11 males and 11 females; mean age 19.18 ± 2.00 years) having Angle's Class II division 1 malocclusion needing bilateral extractions of maxillary first bicuspids were recruited for this split-mouth randomized clinical trial. After the initial stage of alignment and leveling with contemporary edgewise MBT (McLaughlin-Bennett-Trevisi) prescription brackets (Ortho Organizers, Carlsbad, Calif) of 22 mil, followed by extractions of premolars bilaterally, 6 mm nickel-titanium spring was used to retract the canines separately by applying 150 g force on 0.019 × 0.025-in stainless steel working archwires. LIPUS (1.1 MHz frequency and 30 mW/cm2 intensity output) was applied for 20 minutes extraorally and reapplied after 3 weeks for 2 more successive visits over the root of maxillary canine on the experimental side whereas the other side was placebo. A numerical rating scale- (NRS-) based questionnaire was given to the patients on each visit to record their weekly pain experience. Impressions were also made at each visit before the application of LIPUS (T1, T2, and T3). Models were scanned with a CAD/CAM scanner (Planmeca, Helsinki, Finland). Mann-Whitney U test was applied for comparison of canine movement and pain intensity between both the groups.
Results: No significant difference in the rate of canine movement was found among the experimental (0.90 mm ± 0.33 mm) and placebo groups (0.81 mm ± 0.32 mm). There was no difference in pain reduction between experimental and placebo groups (p > 0.05).
Conclusion: Single-dose application of LIPUS at 3-week intervals is ineffective in stimulating the OTM and reducing associated treatment pain.
Materials and Methods: Twenty patients with Angle's class II div 1 (10 males and 10 females; aged 20.25 ± 3.88 years) needing bilateral extractions of maxillary first bicuspids were recruited. Conventional brackets MBT of 0.022 in slot (McLaughlin Bennett Trevisi) prescription braces (Ortho Organizers, Carlsbad, Calif) were bonded. After alignment and levelling phase, cuspid retraction began with nitinol closed coil spring on 19 × 25 stainless steel archwire, wielding 150 gram force. 7.5 J/cm2 energy was applied on 10 points (5 buccal and 5 palatal) on the canine roots on the investigational side using gallium-aluminum-arsenic diode laser (940 nm wavelength, iLase™ Biolase, Irvine, USA) in a continuous mode. Target tissues were irradiated once in three weeks for 9 weeks at a stretch (T0, T1, and T2). Patients were given a feedback form based on the numeric rating scale (NRS) to record the pain intensity for a week. Silicon impressions preceded the coil activation at each visit (T0, T1, T2, and T3), and the casts obtained were scanned with the Planmeca CAD/CAM™ (Helsinki, Finland) scanner.
Results: The regimen effectively accelerated (1.55 ± 0.25 mm) tooth movement with a significant reduction in distress on the investigational side as compared to the placebo side (94 ± 0.25 mm) (p < 0.05).
Conclusions: This study reveals that the thrice-weekly LLLT application can accelerate OTM and reduce the associated pain.