Displaying publications 61 - 80 of 117 in total

Abstract:
Sort:
  1. Wong WK, Tan ZN, Lim BH, Mohamed Z, Olivos-Garcia A, Noordin R
    Parasitol Res, 2011 Feb;108(2):425-30.
    PMID: 20922423 DOI: 10.1007/s00436-010-2083-8
    Entamoeba histolytica is the etiologic agent for amoebiasis. The excretory-secretory (ES) products of the trophozoites contain virulence factors and antigens useful for diagnostic applications. Contaminants from serum supplements and dead trophozoites impede analysis of ES. Therefore, a protein-free medium that can sustain maximum viability of E. histolytica trophozoites for the longest time duration will enable collection of contaminant-free and higher yield of ES products. In the present study, we compared the efficacy of four types of media in maintaining ≥ 95% trophozoite viability namely Roswell Memorial Park Institute (RPMI-1640), Dulbecco's Modified Eagle Medium (DMEM), phosphate-buffered saline for amoeba (PBS-A), and Hank's balanced salt solution (HBSS). Concurrently, the effect of adding L: -cysteine and ascorbic acid (C&A) to each medium on the parasite viability was also compared. DMEM and RPMI 1640 showed higher viabilities as compared to PBS-A and HBSS. Only RPMI 1640 showed no statistical difference with the control medium for the first 4 h, however the ≥ 95% viability was only maintained for the first 2 h. The other protein-free media showed differences from the serum- and vitamin-free TYI-S-33 control media even after 1 h of incubation. When supplemented with C&A, all media were found to sustain higher trophozoite viabilities than those without the supplements. HBSS-C&A, DMEM-C&A, and RPMI 1640-C&A demonstrated no difference (P>0.05) in parasite viabilities when compared with the control medium throughout the 8-h incubation period. DMEM-C&A showed an eightfold increment in time duration of sustaining ≥ 95% parasite viability, i.e. 8 h, as compared to DMEM alone. Both RPMI 1640-C&A and HBSS-C&A revealed fourfold and threefold increments (i.e., 8 and 6 h, respectively), whereas PBS-A-C&A showed only one fold improvement (i.e., 2 h) as compared to the respective media without C&A. Thus, C&A-supplemented DMEM or RPMI are recommended for collection of ES products.
  2. Othman N, Mohamed Z, Verweij JJ, Huat LB, Olivos-García A, Yeng C, et al.
    Foodborne Pathog Dis, 2010 Jun;7(6):637-41.
    PMID: 20132028 DOI: 10.1089/fpd.2009.0427
    Entamoeba histolytica is the second major cause of liver abscess disease in humans, particularly in developing countries. Recently, DNA molecular-based methods have been employed to enhance the detection of E. histolytica in either pus or stool specimens. In this study, the results of real-time polymerase chain reaction (PCR) to detect E. histolytica DNA in pus from liver abscess cases were compared with those of indirect hemagglutination assay on the corresponding serum samples. Bacterial cultures were also performed on the pus samples for the diagnosis of pyogenic liver abscess. The real-time PCR detected E. histolytica DNA in 23 of 30 (76.7%) pus samples, when compared with 14 of 30 (46.7%) serum samples in which anti-Entamoeba antibodies were detected by indirect hemagglutination assay and 4 of 30 (13.3%) pus samples that showed bacterial infection by culture. The use of real-time PCR is a promising detection method for diagnosis and epidemiology assessment of amoebic liver abscess.
  3. Noordin R, Itoh M, Kimura E, Abdul Rahman R, Ravindran B, Mahmud R, et al.
    Filaria journal, 2007;6:9.
    PMID: 17961262
    In the global effort to eliminate lymphatic filariasis (LF), rapid field-applicable tests are useful tools that will allow on-site testing to be performed in remote places and the results to be obtained rapidly. Exclusive reliance on the few existing tests may jeopardize the progress of the LF elimination program, thus the introduction of other rapid tests would be useful to address this issue. Two new rapid immunochromatographic IgG4 cassette tests have been produced, namely WB rapid and panLF rapid, for detection of bancroftian filariasis and all three species of lymphatic filaria respectively. WB rapid was developed using BmSXP recombinant antigen, while PanLF rapid was developed using BmR1 and BmSXP recombinant antigens. A total of 165 WB rapid and 276 panLF rapid tests respectively were evaluated at USM and the rest were couriered to another university in Malaysia (98 WB rapid, 129 panLF rapid) and to universities in Indonesia (56 WB rapid, 62 panLF rapid), Japan (152 of each test) and India (18 of each test) where each of the tests underwent independent evaluations in a blinded manner. The average sensitivities of WB rapid and panLF rapid were found to be 97.6% (94%-100%) and 96.5% (94%-100%) respectively; while their average specificities were both 99.6% (99%-100%). Thus this study demonstrated that both the IgG4 rapid tests were highly sensitive and specific, and would be useful additional tests to facilitate the global drive to eliminate this disease.
  4. Makhsin SR, Razak KA, Noordin R, Zakaria ND, Chun TS
    Nanotechnology, 2012 Dec 14;23(49):495719.
    PMID: 23164811 DOI: 10.1088/0957-4484/23/49/495719
    This study describes the properties of colloidal gold nanoparticles (AuNPs) with sizes of 20, 30 and 40 nm, which were synthesized using citrate reduction or seeding-growth methods. Likewise, the conjugation of these AuNPs to mouse anti-human IgG(4) (MαHIgG(4)) was evaluated for an immunochromatographic (ICG) strip test to detect brugian filariasis. The morphology of the AuNPs was studied based on the degree of ellipticity (G) of the transmission electron microscopy images. The AuNPs produced using the seeding-growth method showed lower ellipticity (G ≤ 1.11) as compared with the AuNPs synthesized using the citrate reduction method (G ≤ 1.18). Zetasizer analysis showed that the AuNPs that were synthesized using the seeding-growth method were almost monodispersed with a lower polydispersity index (PDI; PDI≤0.079), as compared with the AuNPs synthesized using the citrate reduction method (PDI≤0.177). UV-visible spectroscopic analysis showed a red-shift of the absorbance spectra after the reaction with MαHIgG(4), which indicated that the AuNPs were successfully conjugated. The optimum concentration of the BmR1 recombinant antigen that was immobilized on the surface of the ICG strip on the test line was 1.0 mg ml(-1). When used with the ICG test strip assay and brugian filariasis serum samples, the conjugated AuNPs-MαHIgG(4) synthesized using the seeding-growth method had faster detection times, as compared with the AuNPs synthesized using the citrate reduction method. The 30 nm AuNPs-MαHIgG(4), with an optical density of 4 from the seeding-growth method, demonstrated the best performance for labelling ICG strips because it displayed the best sensitivity and the highest specificity when tested with serum samples from brugian filariasis patients and controls.
  5. Noordin R, Smith HV, Mohamad S, Maizels RM, Fong MY
    Acta Trop, 2005 Jan;93(1):57-62.
    PMID: 15589798
    Diagnosis of human toxocariasis, caused by Toxocara canis or Toxocara cati, normally relies on a combination of the presence of clinical signs and symptoms backed by positive serology. The use of Toxocara excretory-secretory antigen (TES) in ELISA assays increases the test specificity. However, in tropical countries where soil-transmitted helminths are endemic, cross-reactivity from antibodies to these intestinal parasites poses a significant limitation for Toxocara serodiagnosis. To increase the specificity of serodiagnosis, we compared the use of IgG-ELISA to the use of IgG4-ELISA using commercially manufactured TES-coated plates. The sensitivity of the IgG-ELISA was 97.1%, while that of the IgG4-ELISA was 45.7%; the specificities were 36.0 and 78.6%, respectively. The study shows that employing both assays can improve the serodiagnosis of toxocariasis. An IgG4 immunoassay would also be useful in the secondary screening of antigen clones in the effort to develop improved serological tests for toxocariasis.
  6. Lim BH, Noordin R, Nor ZM, Rahman RA, Abdullah KA, Sinnadurai S
    Exp Parasitol, 2004 Sep-Oct;108(1-2):1-6.
    PMID: 15491542
    BmR1 recombinant antigen has previously been shown to demonstrate high sensitivity and specificity in the serological diagnosis of brugian filariasis in humans. In this study, the pattern of recognition of antibody to BmR1 during Brugia malayi infection was investigated by employing Meriones unguiculatus as the experimental model. Thirty two gerbils were infected subcutaneously with 120 L(3); and two control groups each comprising 25 animals were employed. ELISA using BmR1 was used to detect filaria-specific IgG antibodies elicited by the gerbils; using sera collected from the day 1 until day 150 post-inoculation (p.i.). The results showed that BmR1 detected B. malayi infection in gerbils harboring adult worms irrespective of the presence of circulating microfilaria, and was exemplified by positive ELISA results in nine a microfilaraemic animals that harbored live adult worms. The initial time of the antibody recognition was at day 8 p.i. and the antibody titre showed some correlation with adult worm burden.
  7. Noordin R, Wahyuni S, Mangali A, Huat LB, Yazdanbakhsh M, Sartono E
    Filaria journal, 2004 Aug 12;3(1):8.
    PMID: 15307892
    BACKGROUND: Brugia malayi is endemic in several Asian countries with the highest prevalence in Indonesia. Determination of prevalence of lymphatic filariasis by serology has been performed by various investigators using different kinds of antigen (either soluble worm antigen preparations or recombinant antigens). This investigation compared the data obtained from IgG4 assays using two different kinds of antigen in a study on prevalence of antibodies to B. malayi. METHODS: Serum samples from a transmigrant population and life long residents previously tested with IgG4 assay using soluble worm antigen (SWA-ELISA), were retested with an IgG4 assay that employs BmR1 recombinant antigen (BmR1 dipstick [Brugia Rapid trade mark ]). The results obtained with the two antigens were compared, using Pearson chi-square and McNemar test. RESULTS: There were similarities and differences in the results obtained using the two kinds of antigen (SWA and BmR1). Similarities included the observation that assays using both antigens demonstrated an increasing prevalence of IgG4 antibodies in the transmigrant population with increasing exposure to the infection, and by six years living in the area, antibody prevalence was similar to that of life-long residents. With regards to differences, of significance is the demonstration of similar antibody prevalence in adults and children by BmR1 dipstick whereas by SWA-ELISA the antibody prevalence in adults was higher than in children. CONCLUSIONS: Results and conclusions made from investigations of prevalence of anti-filarial IgG4 antibody in a population would be affected by the assay employed in the study.
  8. Zainudin NS, Othman N, Muhi J, Abdu Sani AA, Noordin R
    Am J Trop Med Hyg, 2015 Dec;93(6):1268-73.
    PMID: 26392156 DOI: 10.4269/ajtmh.15-0333
    This study was performed to identify circulating Plasmodium falciparum proteins in patient serum, which may be useful as diagnostic markers. Depletion of highly abundant proteins from each pooled serum sample obtained from P. falciparum-infected patients and healthy individuals was performed using the Proteoseek Antibody-Based Albumin/IgG Removal Kit (Thermo Scientific, Rockford, IL). In analysis 1, the depleted serum was analyzed directly by NanoLC-MS/MS. In analysis 2, the depleted serum was separated by two-dimensional electrophoresis followed by western blot analysis. Subsequently, the selected band was analyzed by NanoLC-MS/MS. The result of analysis 1 revealed the presence of two mature erythrocyte surface antigen (MESA) proteins and chloroquine resistance transporter protein (PfCRT). In addition, analysis 2 revealed an antigenic 75-kDa band when the membrane was probed with purified IgG from the pooled serum obtained from P. falciparum-infected patients. MS/MS analysis of this protein band revealed fragments of P. falciparum MESA proteins. Thus, in this study, two different analyses revealed the presence of Plasmodium MESA protein in pooled serum from malaria patients; thus, this protein should be further investigated to determine its usefulness as a diagnostic marker.
  9. Zahabiun F, Sadjjadi SM, Yunus MH, Rahumatullah A, Moghaddam MH, Saidin S, et al.
    Am J Trop Med Hyg, 2015 Aug;93(2):319-25.
    PMID: 26033026 DOI: 10.4269/ajtmh.15-0190
    Toxocariasis is a cosmopolitan zoonotic disease caused by the infective larvae of Toxocara canis and T. cati. Diagnosis in humans is usually based on clinical symptoms and serology. Immunoglobulin G (IgG)-enzyme-linked immunosorbent assay kits using T. canis excretory-secretory (TES) larval antigens are commonly used for serodiagnosis. Differences in the antigens of the two Toxocara species may influence the diagnostic sensitivity of the test. In this study, T. cati recombinant TES-120 (rTES-120) was cloned, expressed, and compared with its T. canis homolog in an IgG4-western blot. The diagnostic sensitivity and specificity of T. cati rTES-120 were 70% (33/47) and 100% (39/39), respectively. T. canis rTES-120 showed 57.4% sensitivity and 94.4% specificity. When the results of assays using rTES-120 of both species were considered, the diagnostic sensitivity was 76%. This study shows that using antigens from both Toxocara species may improve the serodiagnosis of toxocariasis.
  10. Arifin N, Basuni M, Lan CA, Yahya AR, Noordin R
    Protein J, 2010 Oct;29(7):509-15.
    PMID: 20845068 DOI: 10.1007/s10930-010-9281-1
    This paper describes a refinement in the purification step that facilitated the downstream recovery of high purity BmR1 recombinant protein, which is a protein used as a test reagent in the commercialized rapid tests for detection of lymphac filariasis i.e. Brugia Rapid™ and panLF rapid™. Purification was performed by immobilized metal affinity chromatography (IMAC), followed by ion exchange chromatography (IEX). Results showed that a total of 10.27 mg of BmR1 was obtained when IMAC was performed using 20 mM of imidazole and 5 column volume of wash buffer containing 500 mM of NaCl. Purity of the target protein was enhanced when buffer at pH 5.8 was used during the IEX. Two proteins that recurrently appeared below the BmR1 recombinant protein were identified by mass-spectrometry analysis as the same protein, thus they were probably degradation products of BmR1. These strategies improve purity of the target protein to be used in applications such as production of aptamers and monoclonal antibodies.
  11. Noordin R, Khanbabaie S, Hafiznur Yunus M, Marti H, Nickel B, Fasihi Harandi M, et al.
    Iran J Parasitol, 2020 10 22;15(3):290-298.
    PMID: 33082792 DOI: 10.18502/ijpa.v15i3.4191
    Background: Human echinococcosis is a neglected zoonotic disease distributed worldwide. It comprises cystic and alveolar forms, the former being the more prevalent disease. Imaging techniques are the first choice for diagnosis of cystic echinococcosis and serology is used as an additional diagnostic technique in doubtful cases or as the sole test in low-resource settings. Rapid diagnostic tests are useful and convenient for immunodiagnosis of cystic echinococcosis in endemic areas, where medical facilities often struggle with limited resources.

    Methods: Recently, we have developed Hyd Rapid™, an IgG4 lateral flow dipstick test using recombinant antigen B1 for detection of cystic echinococcosis. This study was performed between 2016 until 2018 at the Institute for Research in Molecular Medicine, Universiti Sains Malaysia. The diagnostic performance of Hyd Rapid™ was tested in-house and at two international laboratories in Switzerland and Iran.

    Results: The overall diagnostic sensitivity for detection of cystic and alveolar echinococcosis was 95% (56/59). Meanwhile, the diagnostic specificity, with and without exclusion of cysticercosis and fascioliasis, was 100% (n=48) and 88% (63/72), respectively.

    Conclusion: Hyd Rapid™ detected cystic echinococcosis as well as probable cases of alveolar echinococcosis. Therefore, Hyd Rapid™ showed good potential as a serological tool for echinococcosis, and merits further evaluation.

  12. Rahumatullah A, Ahmad A, Noordin R, Lai JY, Baharudeen Z, Lim TS
    Exp Parasitol, 2020 Dec;219:108029.
    PMID: 33096112 DOI: 10.1016/j.exppara.2020.108029
    Echinococcus granulosus is a worldwide zoonotic infection that causes human cystic echinococcosis (CE) or hydatid disease. The present study describes the isolation and production of a monoclonal antibody against recombinant AgB protein using the developed Human AntibodY Disease ENhanced (HAYDEN)-Filariasis library. The DNA sequences of the isolated clones were analyzed, followed by gene analysis and binding assays. Clone E1 showed a full-length sequence and represents the IgHV5-LV3 antibody gene family. The antibody protein yield was satisfactory, and it reacted specifically against rAgB. The novel E1 protein is potentially useful for the development of an antigen detection assay for CE. The ability of the Brugia malayi immune antibody library to isolate antibodies against Echinococcus granulosus antigens highlights the broad coverage of immune antibody libraries.
  13. Khan AH, Khanbabaie S, Yunus MH, Mohd Zain SN, Mohd Baharudeen Z, Sahimin N, et al.
    J Immigr Minor Health, 2020 Oct;22(5):1105-1108.
    PMID: 32445161 DOI: 10.1007/s10903-020-01029-y
    Hydatid disease is not endemic in Malaysia; however, its migrant workers originate from neighboring countries where the disease is prevalent. Thus, this study was aimed at investigating the seroprevalence of hydatid disease among the workers. A total of 479 migrant workers were screened for hydatid disease. The sociodemographic information was collected, and serum samples were tested with a rapid dipstick test for hydatid disease called Hyd Rapid™. The present study showed that 13.6% of the migrant workers were found to be seropositive for hydatid disease. The highest seroprevalence was seen among Indian workers (29.41%), followed by Myanmarese (21.43%), Bangladeshis (14.92%), Nepalese (10.68%), and Indonesian (10.66%). This is the first study that highlights the likely presence of hydatid disease among the migrant workers in Malaysia, which may be of interest to the health authorities.
  14. Tan ZN, Wong WK, Noordin R, Zeehaida M, Olivos GA, Lim BH
    Trop Biomed, 2013 Jun;30(2):250-6.
    PMID: 23959490 MyJurnal
    Entamoeba histolytica causes amoebic diarrhoea, colitis and liver abscess (ALA). Diagnosis of ALA is difficult, as most patients do not have simultaneous intestinal amoebic infection. At Hospital Universiti Sains Malaysia (HUSM), diagnosis of ALA relies on a combination of clinical findings, ultrasound examination of the liver and serodiagnosis using a commercial kit. In this study, two in-house indirect ELISAs were developed and evaluated. One of the in-house assays utilises E. histolytica crude soluble antigen (CSA) to detect serum IgG specific to the parasite whereas the other uses E. histolytica ether extract antigen (EEA). Preparation of CSA requires a sonicator to lyse the amoeba whereas EEA was prepared by chemically solubilizing the trophozoites. Based on the cut-off value of mean optical density + 3SD, CSA-ELISA showed 100% (24/24) sensitivity and 93.33% (210/225) specificity; while EEA-ELISA showed 91.67% (22/24) sensitivity and 95.11% (214/225) specificity. In conclusion, both the in-house indirect ELISAs were found to be efficacious for diagnosis of ALA; and the EEA is easier to prepare than the commonly used CSA.
  15. Tan AA, Azman SN, Abdul Rani NR, Kua BC, Sasidharan S, Kiew LV, et al.
    Trop Biomed, 2011 Dec;28(3):620-9.
    PMID: 22433892 MyJurnal
    There is a great diversity of protein samples types and origins, therefore the optimal procedure for each sample type must be determined empirically. In order to obtain a reproducible and complete sample presentation which view as many proteins as possible on the desired 2DE gel, it is critical to perform additional sample preparation steps to improve the quality of the final results, yet without selectively losing the proteins. To address this, we developed a general method that is suitable for diverse sample types based on phenolchloroform extraction method (represented by TRI reagent). This method was found to yield good results when used to analyze human breast cancer cell line (MCF-7), Vibrio cholerae, Cryptocaryon irritans cyst and liver abscess fat tissue. These types represent cell line, bacteria, parasite cyst and pus respectively. For each type of samples, several attempts were made to methodically compare protein isolation methods using TRI-reagent Kit, EasyBlue Kit, PRO-PREP™ Protein Extraction Solution and lysis buffer. The most useful protocol allows the extraction and separation of a wide diversity of protein samples that is reproducible among repeated experiments. Our results demonstrated that the modified TRI-reagent Kit had the highest protein yield as well as the greatest number of total proteins spots count for all type of samples. Distinctive differences in spot patterns were also observed in the 2DE gel of different extraction methods used for each type of sample.
  16. Rahumatullah A, Balachandra D, Noordin R, Baharudeen Z, Lim YY, Choong YS, et al.
    Sci Rep, 2021 01 28;11(1):2502.
    PMID: 33510342 DOI: 10.1038/s41598-021-82125-3
    Antibodies have different chemical properties capable of targeting a diverse nature of antigens. Traditionally, immune antibody libraries are perceived to be disease-specific with a skewed repertoire. The complexity during the generation of a combinatorial antibody library allows for a skewed but diverse repertoire to be generated. Strongyloides stercoralis is a parasite that causes strongyloidiasis, a potentially life-threatening disease with a complex diagnosis that impedes effective control and treatment of the disease. This study describes the isolation of monoclonal antibodies against S. stercoralis NIE recombinant protein using an immune antibody phage display library derived from lymphatic filaria-infected individuals. The isolated antibody clones showed both lambda and kappa light chains gene usage, with diverse amino acid distributions. Structural analysis showed that electropositivity and the interface area could determine the binding affinity of the clones with NIE. The successful identification of S. stercoralis antibodies from the filarial immune library highlights the breadth of antibody gene diversification in an immune antibody library that can be applied for closely related infections.
  17. Kumarasamy G, Abdus Sani AA, Olivos-García A, Noordin R, Othman N
    Pathog Glob Health, 2020 09;114(6):333-342.
    PMID: 32536281 DOI: 10.1080/20477724.2020.1780402
    Amoebiasis, caused by Entamoeba histolytica, is one of the leading parasitic infections in the world. This study was aimed at profiling antigenic membrane proteins of a virulent variant of E. histolytica HM-1:IMSS. The membrane proteins were extracted using ProteoExtract® kit (Merck, Darmstadt, Germany) or conventional method, separated using OFFGEL 3100 fractionator (Agilent Technologies, Santa Clara, California), followed by SDS-PAGE and Western blot analysis. Selected antigenic membrane proteins were identified using LC-ESI-MS/MS. Subsequently, the proteins were classified according to their biological processes and predictions were made on membrane and membrane-associated proteins. When the proteins were probed with pooled sera from amoebic liver abscess (ALA) patients, 10 and 15 antigenic proteins with molecular weights 25 to 200 kDa were identified using the ProteoExtract® kit and conventional method, respectively. LC-ESI-MS/MS identified 13 antigenic proteins, and both extraction methods predicted six of them as membrane and membrane-associated proteins. The topmost biological processes which comprised of six proteins were involved in cellular processes.. These antigenic membrane proteins merit further investigations as potential candidates for vaccine studies.
  18. Balachandra D, Rahumatullah A, Lim TS, Mustafa FH, Ahmad H, Anuar NS, et al.
    Acta Trop, 2021 Sep;221:105986.
    PMID: 34058161 DOI: 10.1016/j.actatropica.2021.105986
    Serodiagnosis is an essential component of the laboratory diagnosis of Strongyloides infection and is usually performed using an indirect IgG antibody test. A direct antigen detection method can complement the IgG assay, particularly for detecting early infection and post-treatment follow-up. In the present study, a recombinant scFv monoclonal antibody against NIE recombinant protein (rMAb23) that we had previously produced was used to develop a Strongyloides antigen detection ELISA (SsAg-ELISA). The assay is based on detecting immune complexes of circulating NIE antigens bound to Strongyloides-specific IgG antibodies. The optimized ELISA parameters were 10 µg/mL of rMAb23 coated on microtitre plate wells, 2% skim milk as blocking reagent, 1:100 serum dilution, and 1:1000 goat anti-human IgG F(ab')2 conjugated to horseradish peroxidase. Four groups of serum samples were used, i.e., Strongyloides-positive serum samples categorized into Groups IA and IB; the former were from probable chronic infections and the latter from probable early/acute infections. Strongyloides-negative samples comprising Groups II (healthy samples) and III (other infections); the latter were from eleven different types of other parasitic infections. The receiver operating characteristic (ROC) curve showed an area under the curve (AUC) of 1.00, cut-off optical density (OD405) of 0.5002, and 100% diagnostic sensitivity and specificity. The results of the commercial IgG-ELISA and SsAg-ELISA from Group IA were found to be moderately correlated (r = 0.416; p 
  19. Sahimin N, Yunus MH, Douadi B, Yvonne Lim AL, Noordin R, Behnke JM, et al.
    Trop Biomed, 2019 Dec 01;36(4):1014-1026.
    PMID: 33597471
    The influx of low skilled migrant workers to Malaysia from low socio-economic countries where gastrointestinal parasitic infections are prevalent has raised concerns about transmission to the local population. Three methods for detection (serology, microscopy and molecular techniques) were utilized to identify Entamoeba infections amongst the targeted cohort and determine risk factors associated with infection. Serological screening of 484 migrant workers from five working sectors in Peninsular Malaysia using IgG4 ELISA based on the rPPDK antigen showed an overall seroprevalence of 7.4% (n = 36; CL95 = 5.3-10.1%) with only one factor statistically associated with seropositivity of anti-amoebic antibodies, i.e. years of residence in Malaysia (χ2 1 = 4.007, p = 0.045). Microscopic examination of 388 faecal samples for protozoan cysts and trophozoites showed a slightly higher prevalence (11.6%; n=45; CL95: 8.4-14.8%). Meanwhile, amplification of the 16S rDNA gene detected two species i.e. Entamoeba dispar (23/388; 5.9%; CL95: 3.6-8.3%) and E. histolytica (11/388; 2.8%; CL95: 1.2-4.5%) and mixed infections with both parasites in only three samples (3/388; 0.8%; CL95: 0.2-2.2%). Entamoeba dispar infection was significantly associated with those employed in food and domestic services (χ2 4 = 12.879, p = 0.012). However, none of the factors affected the prevalence of E. histolytica infection. Despite the low prevalence of E. histolytica in faecal samples of the study cohort, the presence of this pathogenic parasite still poses potential public health risks and calls for tighter control strategies based on better availability of chemotherapeutic treatment and accessibility to appropriate health education.
  20. Vola A, Tamarozzi F, Noordin R, Yunus MH, Khanbabaie S, De Silvestri A, et al.
    Diagn Microbiol Infect Dis, 2018 Sep;92(1):31-33.
    PMID: 29776711 DOI: 10.1016/j.diagmicrobio.2018.04.007
    Rapid diagnostic tests for cystic echinococcosis (CE) are convenient to support ultrasound diagnosis in uncertain cases, especially in resource-limited settings. We found comparable diagnostic performances of the experimental Hyd Rapid Test and the commercial VIRapid HYDATIDOSIS Test, used in our diagnostic laboratory, using samples from well-characterized hepatic CE cases.
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links