  1. Khandaker MU, Nagatsu K, Minegishi K, Zhang MR, Jalilian AR, Bradley DA
    Appl Radiat Isot, 2020 Sep 15;166:109428.
    PMID: 32979754 DOI: 10.1016/j.apradiso.2020.109428
    186gRe (T1/2 = 3.7183 d, E(β-)mean = 346.7 keV, I(β-)mean = 92.59%), a mixed beta and γ-emitter shows great potential for use in theranostic applications. The dominant 185Re(n,γ) route, via use of a nuclear reactor, provides 186gRe in carrier added form with low specific activity, while cyclotrons offer no carrier-added (NCA) high specific activity production of 186gRe. However, to be able to select the best possible nuclear reaction and to optimize the production route via the use of a cyclotron, information on the excitation function for the reaction of interest as well as for the competing reactions is necessary. Accordingly, we have conducted a detailed study of the excitation functions for natW(d, x) reactions in seeking optimized parameters for the NCA production of 186gRe. Noting a discrepancy among the experimental data, we made an evaluation of the available literature, finally selecting optimum parameters for the production of 186gRe via the 186W(d,2n)186Re reaction. These beam parameters were then used for batch production of 186gRe by irradiating an enriched 186W metallic powder target, followed by a subsequent automated chemical separation process. The preliminary results show 98.1% radionuclidic purity of 186gRe at 8 h subsequent to the End of Bombardment (EOB), offering the potential for use in clinical applications.
  2. Elias MS, Ibrahim S, Samuding K, Kantasamy N, Rahman SA, Hashim A
    Appl Radiat Isot, 2019 Sep;151:116-123.
    PMID: 31174051 DOI: 10.1016/j.apradiso.2019.05.038
    A study was carried out to determine the concentrations of rare earth elements (REEs) in Linggi river sediments collected from 113 sampling locations. The sediment analysis was performed by Neutron activation analysis (NAA) and Inductively coupled plasma - mass spectrometry (ICP-MS). The results of Linggi river sediment were normalized to "recent" reference shale values. The means of total concentrations of REEs (ΣREE), light REEs (ΣLREE) and heavy REEs (ΣHREE) in Linggi sediment were 241.2, 219.2, and 22.0 mg/kg, respectively, which indicates enrichment compared to ΣREE, ΣLREE and ΣHREE reference shale values. Results obtained from enrichment factors (EF) show no enrichment to moderate enrichment of Linggi sediments, indicating the sources of REEs pollution originated from natural and land-based activities. A similar pattern was observed by comparing the REEs values of Linggi sediments to other references shale values. Ce (δCe) and Eu (δEu) anomalies indicate Linggi sediments showed positive anomaly of Ce whilst negative anomaly of Eu.
  3. Rais NNM, Bradley DA, Hashim A, Osman ND, Noor NM
    Appl Radiat Isot, 2019 Nov;153:108810.
    PMID: 31351374 DOI: 10.1016/j.apradiso.2019.108810
    For a range of doses familiarly incurred in computed tomography (CT), study is made of the performance of Germanium (Ge)-doped fibre dosimeters formed into cylindrical and flat shapes. Indigenously fabricated 2.3 mol% and 6 mol% Ge-dopant concentration preforms have been used to produce flat- and cylindrical-fibres (FF and CF) of various size and diameters; an additional 4 mol% Ge-doped commercial fibre with a core diameter of 50 μm has also been used. The key characteristics examined include the linearity index f(d), dose sensitivity and minimum detectable dose (MDD), the performance of the fibres being compared against that of lithium-fluoride based TLD-100 thermoluminescence (TL) dosimeters. For doses in the range 2-40 milligray (mGy), delivered at constant potential of 120 kilovoltage (kV), both the fabricated and commercial fibres demonstrate supralinear behaviours at doses  4 mGy. In terms of dose sensitivity, all of the fibres show superior TL sensitivity when compared against TLD-100, the 2.3 mol% and 6 mol% Ge-doped FF demonstrating the greatest TL sensitivity at 84 and 87 times that of TLD-100. The TL yields for the novel Ge-doped silica glass render them appealing for use within the present medical imaging dose range, offering linearity at high sensitivity down to less than 2 mGy.
  4. Damulira E, Yusoff MNS, Omar AF, Mohd Taib NH, Ahmed NM
    Appl Radiat Isot, 2021 Apr;170:109622.
    PMID: 33592486 DOI: 10.1016/j.apradiso.2021.109622
    This study compares the real-time dosimetric performance of a bpw34 photodiode (PD) and cold white light-emitting diodes (LEDs) based on diagnostic X-ray-induced signals. Signals were extracted when both the transducers were under identical exposure settings, including source-to-detector distance (SDD), tube voltage (kVp), and current-time product (mAs). The transducers were in a photovoltaic configuration, and black vinyl tape was applied on transducer active areas as a form of optical shielding. X-ray beam spectra and energies were simulated using Matlab-based Spektr functions. Transducer performance analysis was based on signal linearity to mAs and air kerma, and sensitivity dependence on absorbed dose, energy, and dose rate. Bpw34 PD and cold white LED output signals were 84.8% and 85.5% precise, respectively. PD signals were 94.7% linear to mAs, whereas LED signals were 91.9%. PD and LED signal linearity to dose coefficients were 0.9397 and 0.9128, respectively. Both transducers exhibited similar dose and energy dependence. However, cold white LEDs were 0.73% less dose rate dependent than the bpw34 PD. Cold white LEDs demonstrated potential in detecting diagnostic X-rays because their performance was similar to that of the bpw34 PD. Moreover, the cold white LED array's dosimetric response was independent of the heel effect. Although cold white LED signals were lower than bpw34 PD signals, they were quantifiable and electronically amplifiable.
  5. Zuber SH, Hashikin NAA, Mohd Yusof MF, Aziz MZA, Hashim R
    Appl Radiat Isot, 2021 Apr;170:109601.
    PMID: 33515930 DOI: 10.1016/j.apradiso.2021.109601
    Experimental particleboards are made from Rhizophora spp. wood trunk with three different percentages of lignin and soy flour (0%, 6% and 12%) as adhesives. The objective was to investigate the equivalence of Rhizophora spp. particleboard as phantom material with human soft tissue using Computed Tomography (CT) number. The linear and mass attenuation coefficient of Rhizophora spp. particleboard at low energy range was also explored using X-ray Fluorescence (XRF) configuration technique. Further characterization of the particleboard was performed to determine the effective atomic number, Zeff using Energy Dispersive X-Ray (EDX) method. Adhesive-bonded Rhizophora spp. particleboard showed close similarities with water, based on the average CT numbers, electron density calibration curve and the analysis of CT density profile, compared to the binderless particleboard. The effective atomic number obtained from the study indicated that the attenuation properties of all the particleboards at different percentages of adhesives were almost similar to water. The mass attenuation coefficient calculated from XRF configuration technique showed good agreement with water from XCOM database, suggesting its potential as phantom material for radiation study.
  6. Gharibshahi E, Saion E, Johnston RL, Ashraf A
    Appl Radiat Isot, 2019 May;147:204-210.
    PMID: 30953937 DOI: 10.1016/j.apradiso.2019.02.015
    Platinum nanoparticles were synthesized using the gamma radiolytic technique in an aqueous solution containing Platinum tetraammine chloride in presence of poly vinyl pyrrolidone, isopropanol, tetrahydrofuran and deionized water. The gamma irradiation was carried out in a60Co gamma source chamber and the particle size was found to decrease from 4.88 to 3.14 nm on increasing the gamma radiation dose from 80 to 120 kGy. UV-visible absorption spectra were measured and revealed two steady absorption maxima at 216 and 264 nm in the UV region, which was blue shifted (i.e. toward lower wavelength) with decreasing particle size. By taking the conduction electrons of an isolated particle that are not entirely free, but instead bound to their respective quantum levels, the optical absorption of platinum nanoparticles can be calculated via intra-band quantum excitation for particle sizes similar to those measured experimentally. We found that the calculated absorption maxima of electronic excitations matched the measured absorption maxima well. This finding suggests that the optical absorption of metal nanoparticles commonly applied in nanoscience and nanotechnology can be described accurately by the quantum excitation of conduction electrons.
  7. Wahib NB, Khandaker MU, Aqilah Binti Mohamad Ramli N, Sani SFA, Bradley DA
    Appl Radiat Isot, 2019 Jun;148:218-224.
    PMID: 31003071 DOI: 10.1016/j.apradiso.2019.04.001
    Study has been made of the thermoluminescence (TL) yield of various glass-based commercial kitchenware (Reko-China, Skoja-France, Godis-China, Glass Tum-Malaysia, Lodrat-France). Interest focuses on their potential for retrospective dosimetry. Use was made of a60Co gamma-ray irradiator, delivering doses in the range 2-10 Gy. Results for the various media show all the glassware brands to yield linearity of response against dose, with a lower limit of detection of ∼0.06 and ∼0.08 Gy for loose and compact powdered samples. Among all of the brands under study, the Lodrat glassware provides the greatest sensitivity, at 6.0 E+02 nC g-1 Gy-1 and 1.5E+03 nC g-1 Gy-1 for compact- and loose-powdered forms respectively. This is sufficiently sensitive to allow its use as a TL material for accident dosimetry (2 Gy being the threshold dose for the onset of a number of deterministic biological effects, including skin erythema and sterility). Energy Dispersive X-ray (EDX) analyses have been conducted, showing the presence of a number of impurities (including C, O, Na, Mg, Al, Si, Ca and Br). Fading of the irradiated glasses show the amount of better than 3% and 5% of the stored energy for both loose and compact powdered samples within 9 days post irradiation. As such, commercial kitchenware glass has the potential to act as relatively good TL material for gamma radiation dosimetry at accident levels. This is the first endeavour reporting the TL properties of low cost commercial kitchenware glasses for gamma-ray doses in the few Gy range, literature existing for doses from 8 Gy to 200 Gy.
  8. Alqahtani A, Sani SFA, Narissa NHA, Alanazi A, Podolyak Z, Nisbet A, et al.
    Appl Radiat Isot, 2020 Jun;160:109132.
    PMID: 32351224 DOI: 10.1016/j.apradiso.2020.109132
    As a result of the various evolving needs, thermoluminescence dosimetry is constantly under development, with applications intended in environmental and personal radiation monitoring through to the sensing of radiotherapy and radiation processing doses. In radiotherapy dosimetry challenges include small-field profile evaluation, encompassing the fine beams of radiosurgery, evaluations confronting the steep dose gradients of electronic brachytherapy and the high dose rates of FLASH radiotherapy. Current work concerns the thermoluminescent dosimetric properties of commercial low-cost borosilicate glass in the form of thin (sub-mm to a few mm) plates, use being made of microscope cover-slips irradiated using clinical external-beam radiotherapy facilities as well as through use of 60Co gamma irradiators. In using megavoltage photons and MeV electrons, characterization of the dosimetric response has been made for cover-slips of thicknesses up to 4 mm. Reproducibility to within +/5% has been obtained. In particular, for doses up to 10 Gy, the borosilicate cover-slips have been demonstrated to have considerable potential for use in high spatial resolution radiotherapy dosimetry, down to 0.13 mm in present work, with a coefficient of determination in respect of linearity of >0.99 for the thinner cover-slips. Results are also presented for 0.13- and 1.00-mm thick cover slips irradiated to 60Co gamma-ray doses, initially in the range 5- to 25 Gy, subsequently extended to 5 kGy-25 kGy, again providing linear response.
  9. Ali SKI, Khandaker MU, Al-Mugren KS, Latif SA, Bradley DA, Okhunov AA, et al.
    Appl Radiat Isot, 2021 Jul;173:109735.
    PMID: 33915407 DOI: 10.1016/j.apradiso.2021.109735
    Copper-67 (T1/2 = 61.83 h, Eβ-mean=141 keV, Iβ-total=100%; Eγ = 184.577 keV, Iγ = 48.7%) is a promising radionuclide for theranostic applications especially in radio immunotherapy. However, one of the main drawbacks for its application is related to its limited availability. Various nuclear reaction routes investigated in the last years can result in 67Cu production, although the use of proton beams is the method of choice taken into account in this work. The goal of this work is a revision of the cross-sections aimed at 67Cu yield, which were evaluated for the 68Zn(p,2p)67Cu reaction route up to 80 MeV proton energy. A well-defined statistical procedure, i.e., the Simultaneous Evaluation on KALMAN (SOK), combined with the least-squares concept, was used to obtain the evaluated data together with the covariance matrix. The obtained evaluated data were also compared to predictions provided by the nuclear reaction model codes TALYS and EMPIRE, and a partial agreement among them has been found. These data may be useful for both existing and potential applications in nuclear medicine, to achieve an improvement and validation of the various nuclear reaction models, and may also find applications in other fields (e.g., activation analysis and thin layer activation).
  10. Sulieman A, Mayhoub FH, Salah H, Al-Mohammed HI, Alkhorayef M, Moftah B, et al.
    Appl Radiat Isot, 2020 Oct;164:109240.
    PMID: 32819499 DOI: 10.1016/j.apradiso.2020.109240
    Lutetium-177 (DOTATATE) (177Lu; T1/2 6.7 days), a labelled β- and Auger-electron emitter, is widely used in treatment of neuroendocrine tumours. During performance of the procedure, staff and other patients can potentially receive significant doses in interception of the gamma emissions [113 keV (6.4%) and 208 keV (11%)] that are associated with the particle decays. While radiation protection and safety assessment are required in seeking to ensure practices comply with international guidelines, only limited published studies are available. The objectives of present study are to evaluate patient and occupational exposures, measuring ambient doses and estimating the radiation risk. The results, obtained from studies carried out in Riyadh over an 11 month period, at King Faisal Specialist Hospital and Research Center, concerned a total of 33 177Lu therapy patients. Patient exposures were estimated using a calibrated Victoreen 451P survey meter (Fluke Biomedical), for separations of 30 cm, 100 cm and 300 cm, also behind a bed shield that was used during hospitalization of the therapy patients. Occupational and ambient doses were also measured through use of calibrated thermoluminescent dosimeters and an automatic TLD reader (Harshaw 6600). The mean and range of administered activity (in MBq)) was 7115.2 ± 917.2 (4329-7955). The ambient dose at corridors outside of therapy isolation rooms was 1.2 mSv over the 11 month period, that at the nursing station was below the limit of detection and annual occupational doses were below the annual dose limit of 20 mSv. Special concern needs to be paid to comforters (carers) and family members during the early stage of radioisotope administration.
  11. Yasmin S, Khandaker MU, Nawi SNM, Sani SFA, Bradley DA, Islam MA
    Appl Radiat Isot, 2021 Sep;175:109782.
    PMID: 34082304 DOI: 10.1016/j.apradiso.2021.109782
    Among the various types of decorative materials used in Bangladeshi dwellings, the marble/marble stone is one of the most common ones that used largely for enhancing the beauty and/or aristocracy of the dwelling environment. In this study, the most commonly used, six types of marble stones, have been analyzed for retrospective accident dosimetry. With the interest of characterizing several key thermoluminescence properties to examine their potentiality for dosimetry, annealing - irradiation - readout steps have been done chronologically which comprises the analysis of glow curves, relative sensitivity, dose dependence, repeatability and fading. Considering the various TL parameters, marble 'Carrara' imported from Italy present relatively better capability for reconstruction of radiation dose in the dose range of 10-50 Gy. From fading result, it is clear that for reconstruction of absorbed dose up to four weeks of post exposure, the marble 'Carrara' is found to be the most reliable media among the studied marble types. The Zeff values for the various marble samples are found to be in the range of 13.65-19.12, comparing favorably in replace of TLD-200 (Zeff = 16.3) which can be used for low-level environmental radiation dosimetry. Present work constitutes the first study to investigate the potentials of marble stone for reconstruction of absorbed dose in the range of 10-50 Gy dose.
  12. Khandaker MU, Mat Nawi SN, Bradley DA, Lam SE, Abdul Sani SF, Sulieman A
    Appl Radiat Isot, 2021 Aug;174:109757.
    PMID: 33990033 DOI: 10.1016/j.apradiso.2021.109757
    This study analysed thermoluminescence (TL) glow curves of the polymer pencil lead graphite (PPLG) due to its potential applications in radiation dosimetry. The TL glow curves provide information on the physical parameters of the defects participating in luminescence process. The glow curves for different diameters PPLG samples were obtained with varying temperature from 50 to 300 °C, at a fixed heating rate of 10 °Cs-1. A number of methods (initial rise, peak shape and curve fitting) were used to fit the TL glow peaks of the PPLG samples obtained under photon dose of 200 Gy. From the fitted TL signals, the trap parameters such as the order of kinetics, the activation energy, the frequency factor, etc. for the individual peaks were numerically determined. The lifetimes of TL process were calculated assuming the first-order kinetics. The results are compared among the different methods adopted in this study. Implications about the possible results in glow curve deconvolution are discussed.
  13. Bradley DA, Ee LS, Mat Nawi SN, Abdul Sani SF, Khandaker M, Alzimami K, et al.
    Appl Radiat Isot, 2021 Aug;174:109769.
    PMID: 34048993 DOI: 10.1016/j.apradiso.2021.109769
    Present work builds upon prior investigations concerning the novel use of graphite-rich polymer pencil-lead for passive radiation dosimetry. Working with photon-mediated interactions at levels of dose familiar in radiotherapy, exploratory investigations have now been made using graphite produced commercially in the form of 50 μm thick sheets. Focusing on the relationship between absorbed radiation energy and induced material changes, investigations have been made of thermo- and photoluminescence dose dependence, also of alterations in Raman spectroscopic features. Photoluminescence studies have focused on the degree of structural order of the samples when exposed to incident MeV energy gamma-radiation, supported by crystallite size evaluations. The results are consistent and evident of structural alterations, radiation-driven thermal annealing also being observed. The results, supportive of previous TL, Raman and photoluminescence studies, are readily understood to arise from irradiation changes occurring at the microscopic level. Notwithstanding the non-linearities observed in the conduct of Raman and photoluminescence studies there is clear potential for applications in use of the defect-dependent methods herein, providing sensitive detection of radiation damage in graphite and from it dose determination. Most specifically, the readily available thin graphite sheets can provide the basis of a low-cost yet highly effective system for studies of radiation-driven changes in carbon (and/or carbon based composites), also as a dosimetric probe of skin dose, its atomic number closely matching with the effective atomic number of soft tissues.
  14. Tamam N, Almuqrin AH, Mansour S, Elnour A, Musa M, Omer H, et al.
    Appl Radiat Isot, 2021 Nov;177:109899.
    PMID: 34438276 DOI: 10.1016/j.apradiso.2021.109899
    Ionizing radiation exposure from medical applications is increasing annually worldwide. It was estimated that 325 million dental procedures were performed in the United States. Radiation exposure from dental radiography consists of intraoral, panoramic, and 3D imaging cone-beam computed tomography (CBCT) imaging. Recent studies reported an association between dental imaging procedures and increased cancer probability of brain and thyroid. Previous studies showed that some dental imaging practices exposed patients and staff to unnecessary radiation doses due to incorrect image acquisition and insufficient radiation protection measures. This study aims to (i) measure the occupational and patients doses during dental procedures and (ii) assess the current imaging techniques and radiation protection practices. Two hundred fourteen patients were evaluated for periapical, bitewing, cephalometric, occlusal, and panoramic procedures. Organ equivalent doses were quantified for the breast, eye lens, and thyroid gland during CBCT procedure. Occupational and ambient dose assessment were assessed using calibrated thermoluminescent dosimeters (TLD-100(LiF: Mg. Ti). Ambient doses were measure at different locations at the department using TLDs. Patients' radiation doses were quantified using kerma area product (PKA (mGy.cm) and the entrance surface air kerma (ESAK (mGy). Fixed tube voltage (65 kVp) and tube current-time product (7 mAs) were used. The overall mean, sd, and range of patients dose values during intraoral (mGy), panoramic and CBCT examinations were 4.6 ± 0.7 (1.4-7.1), 135 ± 45 (75.2-168.5), and 215 ± 165 (186-2115), respectively. The mean and range of the annual occupational doses (mSv) were 1.4 (0.6-3.7), which below the annual dose limits for radiation workers (20 mSv/y). The study showed that inadequate radiation protection for patients existed in terms of the use of the thyroid shield, the technologist's presence inside the room during radiation exposure. Patients' radiation doses were comparable with the international diagnostic reference level (DRL). Staff education and training in radiation protection aspects are highly recommended.
  15. Ahmad P, Khandaker MU, Muhammad N, Rehman F, Ullah Z, Khan G, et al.
    Appl Radiat Isot, 2020 Dec;166:109404.
    PMID: 32956924 DOI: 10.1016/j.apradiso.2020.109404
    The shortcomings in Boron neutron capture therapy (BNCT) and Hyperthermia for killing the tumor cell desired for the synthesis of a new kind of material suitable to be first used in BNCT and later on enable the conditions for Hyperthermia to destroy the tumor cell. The desire led to the synthesis of large band gap semiconductor nano-size Boron-10 enriched crystals of hexagonal boron nitride (10BNNCs). The contents of 10BNNCs are analyzed with the help of x-ray photoelectron spectroscopy (XPS) and counter checked with Raman and XRD. The 10B-contents in 10BNNCs produce 7Li and 4He nuclei. A Part of the 7Li and 4He particles released in the cell is allowed to kill the tumor (via BNCT) whereas the rest produce electron-hole pairs in the semiconductor layer of 10BNNCs suggested to work in Hyperthermia with an externally applied field.
  16. Bradley, Sani SFA, Shafiqah ASS, Collins SM, Hugtenburg RP, Rashid HAA, et al.
    Appl Radiat Isot, 2018 Aug;138:65-72.
    PMID: 28427834 DOI: 10.1016/j.apradiso.2017.04.019
    Using tailor-made sub-mm dimension doped-silica fibres, thermoluminescent dosimetric studies have been performed for α-emitting sources of 223RaCl2 (the basis of the Bayer Healthcare product Xofigo®). The use of 223RaCl2 in the palliative treatment of bone metastases resulting from late-stage castration-resistant prostate cancer focuses on its favourable uptake in metabolically active bone metastases. Such treatment benefits from the high linear energy transfer (LET) and associated short path length (<100µm) of the α-particles emitted by 223Ra and its decay progeny. In seeking to provide for in vitro dosimetry of the α-particles originating from the 223Ra decay series, investigation has been made of the TL yield of various forms of Ge-doped SiO2 fibres, including photonic crystal fibre (PCF) collapsed, PCF uncollapsed, flat and single-mode fibres. Irradiations of the fibres were performed at the UK National Physical Laboratory (NPL). Notable features are the considerable sensitivity of the dosimeters and an effective atomic number Zeff approaching that of bone, the glass fibres offering the added advantage of being able to be placed directly into liquid. The outcome of present research is expected to inform development of doped fibre dosimeters of versatile utility, including for applications as detailed herein.
  17. Bradley DA, Zubair HT, Oresegun A, Louay GT, Ariffin A, Khandaker MU, et al.
    Appl Radiat Isot, 2018 Nov;141:176-181.
    PMID: 29673719 DOI: 10.1016/j.apradiso.2018.02.025
    In previous work we investigated the real-time radioluminescence (RL) yield of Ge-doped silica fibres and Al2O3 nanodot media, sensing electron- and x-ray energies and intensities at values familiarly obtained in external beam radiotherapy. The observation of an appreciable low-dose sensitivity has given rise to the realisation that there is strong potential for use of RL dosimetry in diagnostic radiology. Herein use has been made of P-doped silica optical fibre, 2 mm diameter, also including a 271 µm cylindrical doped core. With developing needs for versatile x-ray imaging dosimetry, preliminary investigations have been made covering the range of diagnostic x-ray tube potentials 30 kVp to 120 kVp, demonstrating linearity of RL with kVp as well as in terms of the current-time (mAs) product. RL yields also accord with the inverse-square law. Given typical radiographic-examination exposure durations from tens- to a few hundred milliseconds, particular value is found in the ability to record the influence of x-ray generator performance on the growth and decay of beam intensity, from initiation to termination.
  18. Obata H, Khandaker MU, Furuta E, Nagatsu K, Zhang MR
    Appl Radiat Isot, 2018 Jul;137:250-260.
    PMID: 29679927 DOI: 10.1016/j.apradiso.2018.03.021
    We studied the excitation functions of residual radionuclides produced via proton and deuteron bombardment on natural iridium in the energy ranges of 30-15 MeV and 50-15 MeV, respectively. A conventional stacked-foil activation technique combined with HPGe γ-ray spectrometry was used to measure the excitation functions for 189, 191Pt and 189, 190g, 192g, 194gIr radionuclide production. Theoretical thick target yields were estimated to be 172 MBq/µA h and 192 MBq/µA h via the 193Ir(p,3n)191Pt reaction at 29.6-17.5 MeV and the 193Ir(d,4n)191Pt reaction at 40.3-23.8 MeV, respectively. The feasibility of 191Pt production from an iridium target was discussed, and compared with previously reported methods for the production of 191Pt.
  19. Sulieman A, Elhag B, Alkhorayef M, Babikir E, Theodorou K, Kappas C, et al.
    Appl Radiat Isot, 2018 Aug;138:40-44.
    PMID: 28757351 DOI: 10.1016/j.apradiso.2017.07.013
    The objectives of this study are to assess pediatric radiation exposure in certain barium studies and to quantify the organ and effective doses and radiation risk resultant from patients' irradiation. A total of 69 pediatric barium studies for upper and lower gastrointestinal tract. Patients' radiation dose was quantified in terms of Entrance surface air kerma (ESAKs) using exposure parameters and DosCal software. Organ and effective doses (E) were extrapolated using national Radiological Protection Board software (NRPB-R279). The mean ± (SD) and the range of patient doses per procedure were 3.7 ± 0.4 (1.0-13.0)mGy, 7.4 ± 1.7(5.5-8.0)mGy and 1.4 ± 0.9 (0.5-3.6)mGy for barium meal, swallow and enema, respectively. The mean effective doses were 0.3 ± 0.03 (0.08-1.1)mSv, 0.2 ± 1.6 (0.44-0.7)mSv and 0.3 ± 0.9 (0.1-0.8)mSv at the same order. The radiation dose were higher compared to previous studies. Therefore, pediatrics are exposed to avoidable radiation exposure. Certain optimization measures are recommended along with establishing national diagnostic reference level (DRL) to reduce the radiation risk.
  20. Sulieman A, Mahmoud MZ, Serhan O, Alonazi B, Alkhorayef M, Alzimami K, et al.
    Appl Radiat Isot, 2018 Nov;141:261-265.
    PMID: 30054177 DOI: 10.1016/j.apradiso.2018.07.011
    Patient effective doses and the associated radiation risks arising from particular computed tomography (CT) imaging procedures are assessed. The objectives of this research are to measure radiation doses for patients and to quantify the radiogenic risks from CT brain and chest procedures. Patient data were collected from five calibrated CT modality machines in Saudi Arabia. The results are from a study of a total of 60 patients examined during CT procedures using the calibrated CT units. For CT brain and chest, the mean patient effective doses were 1.9 mSv (with a range of 0.6-2.5 mSv) and 7.4 mSv (with a range of 0.5-34.8 mSv) respectively. The radiogenic risk to patients ranged from between 10-5 and 10-4 per procedure. With 65% of the CT procedure cases diagnosed as normal, this prompts re-evaluation of the referral criteria. The establishment of diagnostic reference levels (DRL) and implementation of radiation dose optimisation measures would further help reduce doses to optimal values.