  1. Ho JPY, Merican AM, Ayob KA, Sulaiman SH, Hashim MS
    J Orthop Surg (Hong Kong), 2021 2 27;29(1):2309499021992618.
    PMID: 33632009 DOI: 10.1177/2309499021992618
    BACKGROUND: There is a common perception among surgeons that Asian tibiae are significantly more varus compared to non-Asians, contributed both by an acute medial tibial proximal angle (MPTA) and diaphyseal bowing. Insight into the normative morphology of the tibia allows generation of knowledge towards disease processes and subsequently planning for corrective surgeries.

    METHODS: Computed tomography (CT) scans of 100 normal adult knees, aged 18 years and above, were analysed using a 3-dimensional (3D) analysis software. All tibiae were first aligned to a standard frame of reference and then rotationally aligned to the tibial centroid axis (TCAx) and the transmalleolar axis (tmAx). MPTA was measured from best-fit planes on the surface of the proximal tibia for each rotational alignment. Diaphyseal bowing was assessed by dividing the shaft to three equal portions and establishing the angle between the proximal and distal segments.

    RESULTS: The mean MPTA was 87.0° ± 2.2° (mean ± SD) when rotationally aligned to TCAx and 91.6° ± 2.7° when aligned to tmAx. The mean diaphyseal bowing was 0.1° ± 1.9° varus when rotationally aligned to TCAx and 0.3° ± 1.6° valgus when aligned to tmAx. The mean difference when the MPTA was measured with two different rotational alignments (TCAx and tmAx) was 4.6° ± 2.3°. No statistically significant differences were observed between males and females. Post hoc tests revealed statistically significant difference in MPTA between different ethnic sub-groups.

    CONCLUSION: The morphology of the proximal tibiae in the disease-free Asian knee is inherently varus but not more so than other reported populations. The varus profile is contributed by the MPTA, with negligible diaphyseal bowing. These implications are relevant to surgical planning and prosthesis design.

  2. Tan TK, Ng KT, Lim HJ, Radic R
    J Orthop Surg (Hong Kong), 2021 5 25;29(2):23094990211017352.
    PMID: 34027721 DOI: 10.1177/23094990211017352
    PURPOSE: Perioperative blood loss remains a major challenge to surgeons in anterior cruciate ligament reconstruction (ACLR) surgery, despite of the introduction of minimally invasive approach. Tranexamic acid (TXA) is believed to reduce blood loss, which may minimise the complication of postoperative haemarthrosis with insufficient evidence on its effectiveness in ACLR. The primary aim of this study was to examine the effect of TXA on postoperative blood loss and other secondary outcomes in patients undergoing arthroscopic ACLR surgery.

    METHOD: PUBMED, EMBASE, MEDLINE and CENTRAL database were systematically searched from its inception until November 2020. All randomised clinical trials (RCTs) comparing TXA (intravenous or intra-articular) versus placebo in the arthroscopic ACLR surgery were included. Case series, case report and editorials were excluded.

    RESULTS: Five RCTs comprising of a total of 580 patients (291 in TXA group, 289 in control group) were included for qualitative and quantitative meta-analysis. In comparison to placebo, TXA group was significantly associated with lower postoperative blood loss (mean difference (MD): -81.93 ml; 95% CI -141.80 to -22.05) and lower incidence of needing knee aspiration (odd ratio (OR): 0.19; 95% CI 0.08 to 0.44). Patients who randomised to TXA were also reported to have better range of movement (MD: 2.86; 95% CI 0.54 to 5.18), lower VAS Pain Score (MD: -1.39; 95% CI -2.54 to -0.25) and higher Lysholm Score (MD: 7.38; 95% CI 2.75 to 12.01).

    CONCLUSION: In this meta-analysis, TXA reduced postoperative blood loss with lesser incidence of needing knee aspiration along with better range of knee movement and Lysholm score in patients undergoing arthroscopic ACLR surgery.

  3. Loh KW, Chan CY, Chiu CK, Bin Hasan MS, Kwan MK
    J Orthop Surg (Hong Kong), 2016 08;24(2):273-7.
    PMID: 27574278
    Mitochondrial myopathy, encephalopathy, lactic acidosis, and stroke (MELAS) syndrome is a progressive multisystemic neurodegenerative disorder. MELAS syndrome impairs oxidative phosphorylation and predisposes patients to lactic acidosis, particularly under metabolic stress. We report 2 siblings with MELAS-associated idiopathic scoliosis who underwent posterior spinal instrumented fusion with measures taken to minimise anaesthetic and surgical stress, blood loss, and operating time.
  4. Lee CK, Tan TS, Chan C, Kwan MK
    J Orthop Surg (Hong Kong), 2017 01;25(1):2309499017692683.
    PMID: 28211302 DOI: 10.1177/2309499017692683
    INTRODUCTION: C1 lateral mass (C1LM) screw is a common procedure in spine surgery. However, related studies are lacking in Asia. We aim to determine the safety of C1LM screw for the Chinese, Indians, and Malays.

    METHODS: Three-dimensional computed tomographies of 180 subjects (60 from each ethnic) were analyzed. The length and angulations of C1LM screw and the location of internal carotid artery (ICA) in relation to C1LM were assessed and classified according to the classification by Murakami et al. The incidence of ponticulus posticus (PP) was determined and the differences among the population of these three ethnics were recorded.

    RESULTS: The average base length was 8.5 ± 1.4 mm. The lengths within the lateral mass were between 14.7 ± 1.6 mm and 21.7 ± 2.3 mm. The prevalence of PP was 8.3%. 55.3% (199) of ICA were located in zone 0, 38.3% (138) in zone 1-1, 6.4% (23) in zone 1-2, and none in zone 1-3 and zone 2. The average angulation from the entry point to the ICA was 8.5° ± 6.4° laterally. The mean distance of ICA from C1 anterior cortex was 3.7 ± 1.7 mm (range: 0.6∼11.3). There was no difference in distribution of ICA in zone 1 among the three population (Chinese-47%, Indians-61%, and Malays-53%; p > 0.05).

    CONCLUSIONS: No ICA is located medial to the entry point of C1LM screw. If bicortical purchase of C1LM screw is needed, screw protrusion of less than 3 mm or medially angulated is safe for ICA. The incidence of PP is 8.3% with higher prevalence among the Indian population.

  5. Ling TH, Zakaria AF, Abdullah AT
    J Orthop Surg (Hong Kong), 2017 01;25(1):2309499017690459.
    PMID: 28228050 DOI: 10.1177/2309499017690459
    Neck manipulation is associated with spinal cord injury. However, occurrence of such cases is infrequent. This article presents a 33-year-old gentleman who sustained acute tetraplegia after neck manipulation. The aim of this case report is to create awareness that vigorous neck manipulation could cause injury to the spinal cord.
  6. Sahdi H, Hoong CW, Rasit AH, Arianto F, Siong LK, Abdullah NA
    J Orthop Surg (Hong Kong), 2017 01;25(1):2309499016684989.
    PMID: 28166702 DOI: 10.1177/2309499016684989
    Diplopodia, being a rare congenital disorder, is infrequently discussed in published texts. Most reported cases have accounted the involvement of duplicated preaxial digits with other associated organ system and physical deformities. Here, we present an unusual case of isolated diplopodia involving postaxial toes in a child with no other organ and physical abnormalities. Radiological studies revealed a set of 10-digit-duplicated foot over the lateral aspect of the native foot, complete with phalanges and its corresponding metatarsals as well as tarsals, supplied by an anomalous posterior branch of the popliteal artery. Definitive surgery was performed just before the child was learning to walk.
  7. Miswan MF, Saman MS, Hui TS, Al-Fayyadh MZ, Ali MR, Min NW
    J Orthop Surg (Hong Kong), 2017 01;25(1):2309499017690317.
    PMID: 28215115 DOI: 10.1177/2309499017690317
    INTRODUCTION: We conducted a study to elucidate the correlation between the anatomy of the shoulder joint with the development of rotator cuff tear (RCT) and glenohumeral osteoarthritis (GHOA) by using acromioglenoid angle (AGA).

    MATERIALS AND METHODS: The AGA is a new measured angle formed between the line from midglenoid to lateral end of the acromion with the line parallel to the glenoid surface. The AGA was measured in a group of 85 shoulders with RCT, 49 with GHOA and 103 non-RCT/GHOA control shoulders. The AGA was compared with other radiological parameters, such as, the critical shoulder angle (CSA), the acromion index (AI) and the acromiohumeral interval (AHI). Correlational and regression analysis were performed using SPSS 20.

    RESULTS: The mean AGA was 50.9° (45.2-56.5°) in the control group, 53.3° (47.6-59.1°) in RCT group and 45.5° (37.7-53.2°) in OA group. Among patients with AGA > 51.5°, 61% were in the RCT group and among patients with AGA < 44.5°, 56% were in OA group. Pearson correlation analysis had shown significant correlation between AGA and CSA ( r = 0.925, p < 0.001). It was also significant of AHI in RCT group with mean 6.6 mm (4.7-8.5 mm) and significant AI in OA group with mean 0.68 (0.57-0.78) with p value < 0.001 respectively.

    CONCLUSION: The AGA method of measurement is an excellent predictive parameter for diagnosing RCT and GHOA.

  8. Singh VA, Shah SU, Yasin NF, Abdullah BJJ
    J Orthop Surg (Hong Kong), 2017 May-Aug;25(2):2309499017716256.
    PMID: 28659052 DOI: 10.1177/2309499017716256
    AIMS: Magnetic resonance guided focused ultrasound (MRgFUS) is a new modality in the management of primary and secondary bone tumors. We aimed to investigate the safety, efficacy, and feasibility of using MRgFUS for the treatment of (1) benign bone tumors with the intent of complete tumor ablation, (2) primary malignant bone tumors with the intent to assess its effectiveness in causing tumor necrosis, and (3) metastatic bone disease with the intent of pain relief.

    METHOD: Twenty-four patients with benign bone tumors, primary malignant bone tumors, and metastatic bone disease were treated with one session of MRgFUS. Contrast-enhanced (CE) magnetic resonance imaging (MRI) was carried out post-procedure to assess and quantify the area of ablation. Those with malignant primary tumors had the tumors resected 2 weeks after the treatment and the ablated areas were examined histopathologically (HPE). The other patients were followed up for 3 months to assess for the side effects and pain scores.

    RESULTS: Significant volume of ablation was noted on CE MRI after the treatment. Benign bone tumors were ablated with minimal adverse effects. Metastatic bone disease was successfully treated with significant decrease in pain scores. Ablated primary malignant tumors showed significant coagulative necrosis on MRI and the HPE showed 100% necrosis. Pain scores significantly decreased 3 months after the procedure. Only two patients had superficial skin blistering and three patients had increase in pain scores immediately after treatment.

    CONCLUSION: MRgFUS is effective, safe, and noninvasive procedure that can be an adjunct in the management of primary and metastatic bone tumors.
  9. Kwan MK, Chiu CK, Chan CYW, Zamani R, Hansen-Algenstaedt N
    J Orthop Surg (Hong Kong), 2017 7 28;25(2):2309499017722438.
    PMID: 28748740 DOI: 10.1177/2309499017722438
    PURPOSE: This study analysed the accuracy and safety of the fluoroscopic guided percutaneous screws in the upper thoracic vertebrae (T1-T6).

    METHODS: Computed tomography scans from 74 patients were retrospectively evaluated between January 2008 and December 2012. Pedicle perforations were classified by two types of grading systems. For medial, lateral, superior and inferior perforations: grade 0 - no violation; grade 1 - <2 mm; grade 2 - 2-4 mm and grade 3 - >4 mm. For anterior perforations: grade 0 - no violation; grade 1 - <4 mm; grade 2 - 4-6 mm and grade 3 - >6 mm.

    RESULTS: There were 35 (47.3%) male and 39 (52.7%) female patients with a total 260 thoracic pedicle screws (T1-T6) analysed. There were 32 screw perforations which account to a perforation rate of 12.3% (11.2% grade 1, 0.7% grade 2 and 0.4% grade 3). None led to pedicle screw-related complications. The perforation rate was highest at T1 (33.3%, all grade 1 perforations), followed by T6 (14.5%) and T4 (14.0%).

    CONCLUSION: Fluoroscopic guided percutaneous pedicle screws of the upper thoracic spine (T1-T6) are technically more demanding and carry potential risks of serious complications. Extra precautions need to be taken when fluoroscopic guided percutaneous pedicle screws are placed at T1 and T2 levels, due to high medial pedicular angulation and obstruction of lateral fluoroscopic images by the shoulder girdle and at T4-T6 levels, due to smaller pedicular width.

  10. Hasan MS, Choe NC, Chan CYW, Chiu CK, Kwan MK
    J Orthop Surg (Hong Kong), 2017 May-Aug;25(2):2309499017718951.
    PMID: 28675975 DOI: 10.1177/2309499017718951
    BACKGROUND: Massive blood loss during posterior spinal fusion for adolescent idiopathic scoliosis remains a significant risk for patients. There is no consensus on the benefit of acute normovolemic hemodilution (ANH) or intraoperative cell salvage (ICS) in scoliosis surgery.

    METHODS: Patients were randomized to one of two groups. Group A received ANH and ICS during operation, while group B received only ICS. Patients' age, sex, height, weight, body blood volume, number of fusion level, Cobb angle, number of screws, duration of surgery, and skin incision length were recorded. Hemoglobin and hematocrit levels were obtained preoperatively and postoperatively (0 h and 24 h).

    RESULTS: There were 22 patients in each group. There was no significant difference in total blood loss. The perioperative decrease in hemoglobin levels between preoperation and postoperation 24 h (group A 2.79 ± 1.15 and group B 2.76 ± 1.00) showed no significant difference ( p = 0.93). Group A observed a larger decrease in hemoglobin levels at postoperative 0 h relative to preoperative level (2.57 ± 0.82 g/dl), followed by a smaller decrease within the next 24 h (0.22 ± 1.33 g/dl). Group B showed a continued drop in hemoglobin levels of similar magnitude at postoperation 0 h (1.60 ± 0.67 g/dl) and within the next 24 h (1.16 ± 0.78 g/dl). One patient from group B received 1 unit of allogenic blood transfusion ( p = 0.33).

    CONCLUSIONS: The addition of ANH to ICS in posterior spinal fusion surgery for AIS resulted in a similar decrease in hemoglobin levels between preoperative values and at 24 h postoperatively.
  11. Chiu CK, Chan CYW, Kwan MK
    J Orthop Surg (Hong Kong), 2017 May-Aug;25(2):2309499017713938.
    PMID: 28705124 DOI: 10.1177/2309499017713938
    PURPOSE: This study investigates the safety and accuracy of percutaneous pedicle screws placed using fluoroscopic guidance in the thoracolumbosacral spine among Asian patients.

    METHODS: Computerized tomography scans of 128 patients who had surgery using fluoroscopic-guided percutaneous pedicle screws were selected. Medial, lateral, superior, and inferior screw perforations were classified into grade 0 (no violation), grade 1 (<2 mm perforation), grade 2 (2-4 mm perforation), and grade 3(>4 mm perforation). Anterior perforations were classified into grade 0 (no violation), grade 1 (<4 mm perforation), grade 2 (4-6 mm perforation), and grade 3(>6 mm perforation). Grade 2 and grade 3 perforation were considered as "critical" perforation.

    RESULTS: In total, 1002 percutaneous pedicle screws from 128 patients were analyzed. The mean age was 52.7 ± 16.6. There were 70 male patients and 58 female patients. The total perforation rate was 11.3% (113) with 8.4% (84) grade 1, 2.6% (26) grade 2, and 0.3% (3) grade 3 perforations. The overall "critical" perforation rate was 2.9% (29 screws) and no complications were noted. The highest perforation rates were at T4 (21.6%), T2 (19.4%), and T6 (19.2%).

    CONCLUSION: The total perforation rate of 11.3% with the total "critical" perforation rate of 2.9% (2.6% grade 2 and 0.3% grade 3 perforations). The highest perforation rates were found over the upper to mid-thoracic region. Fluoroscopic-guided percutaneous pedicle screws insertion among Asians has the safety and accuracy comparable to the current reported percutaneous pedicle screws and open pedicle screws techniques.
  12. Hasan MS, Tan JK, Chan CYW, Kwan MK, Karim FSA, Goh KJ
    J Orthop Surg (Hong Kong), 2018 7 31;26(3):2309499018789529.
    PMID: 30058437 DOI: 10.1177/2309499018789529
    BACKGROUND: Drugs used in anesthesia can affect somatosensory evoked potential (SSEP) monitoring, which is used routinely for intraoperative monitoring of spinal cord integrity during spinal surgery.

    OBJECTIVE: The objective of this study was to determine whether combined total intravenous anesthesia (TIVA) technique with propofol/remifentanil is associated with less SSEP suppression when compared to combined volatile agent desflurane/remifentanil anesthesia during corrective scoliosis surgery at a comparable depth of anesthesia.

    DESIGN: It is a randomized controlled trial.

    SETTING: The study was conducted at the Single tertiary University Hospital during October 2014 to June 2015.

    PATIENTS: Patients who required SSEP and had no neurological deficits, and were of American Society of Anesthesiologist I and II physical status, were included. Patients who had sensory or motor deficits preoperatively and significant cardiovascular and respiratory disease were excluded. A total of 72 patients were screened, and 67 patients were randomized and allocated to two groups: 34 in desflurane/remifentanil group and 33 in TIVA group. Four patients from desflurane/remifentanil group and three from TIVA group were withdrawn due to decrease in SSEP amplitude to <0.3 µV after induction of anesthesia. Thirty patients from each group were analyzed.

    INTERVENTIONS: Sixty-seven patients were randomized to receive TIVA or desflurane/remifentanil anesthesia.

    MAIN OUTCOME MEASURES: The measurements taken were the amplitude and latency of SSEP monitoring at five different time points during surgery: before and after the induction of anesthesia, at skin incision, at pedicle screw insertion, and at rod insertion.

    RESULTS: Both anesthesia techniques, TIVA and desflurane/remifentanil, resulted in decreased amplitude and increased latencies of both cervical and cortical peaks. The desflurane/remifentanil group had a significantly greater reduction in the amplitude ( p = 0.004) and an increase in latency ( p = 0.002) of P40 compared with the TIVA group. However, there were no differences in both amplitude ( p = 0.214) and latency ( p = 0.16) in cervical SSEP between the two groups.

    CONCLUSIONS: Compared with TIVA technique, desflurane/remifentanil anesthesia caused more suppression in cortical SSEP, but not in cervical SSEP, at a comparable depth of anesthesia.

  13. Yin Wei CC, Haw SS, Bashir ES, Beng SL, Shanmugam R, Keong KM
    J Orthop Surg (Hong Kong), 2017 01;25(1):2309499017690656.
    PMID: 28219305 DOI: 10.1177/2309499017690656
    OBJECTIVE: To compare construct stiffness of cortical screw (CS)-rod transforaminal lumbar interbody fusion (TLIF) construct (G2) versus pedicle screw (PS)-rod TLIF construct (G1) in the standardized porcine lumbar spine.

    METHODS: Six porcine lumbar spines (L2-L5) were separated into 12 functional spine units. Bilateral total facetectomies and interlaminar decompression were performed for all specimens. Non-destructive loading to assess stiffness in lateral bending, flexion and extension as well as axial rotation was performed using a universal material testing machine.

    RESULTS: PS and CS constructs were significantly stiffer than the intact spine except in axial rotation. Using the normalized ratio to the intact spine, there is no significant difference between the stiffness of PS and CS: flexion (1.41 ± 0.27, 1.55 ± 0.32), extension (1.98 ± 0.49, 2.25 ± 0.44), right lateral flexion (1.93 ± 0.57, 1.55 ± 0.30), left lateral flexion (2.00 ± 0.73, 2.16 ± 0.20), right axial rotation (0.99 ± 0.21, 0.83 ± 0.26) and left axial rotation (0.96 ± 0.22, 0.92 ± 0.25).

    CONCLUSION: The CS-rod TLIF construct provided comparable construct stiffness to a traditional PS-rod TLIF construct in a 'standardized' porcine lumbar spine model.

  14. Singh VA, Sim LH, Haseeb A, Ju CTS
    J Orthop Surg (Hong Kong), 2018 10 23;26(3):2309499018806671.
    PMID: 30343651 DOI: 10.1177/2309499018806671
    PURPOSE: Allograft infection remains the greatest challenge in orthopaedic reconstructive surgery especially methicillin-resistant Staphylococcus aureus (MRSA). This risk can be minimized with the use of antibiotic laden allograft (ALA) via iontophoresis. Ceftaroline fosamil (CF) is an advanced-generation cephalosporin, an alternative treatment for MRSA infections. Its antibacterial activity and safety profile are better than vancomycin. CF iontophoresed bone has not been used before. This study was conducted to establish the feasibility of creating a CF ALA and establish the prime conditions for its expenditure.

    METHOD: We created an iontophoresis cell; 3% CF was inserted within medullary segment of goat bone and sealed from external saline solution. The cell operated at the following voltages 30, 60 and 90 V and at the following durations 5, 10, 15, 20, 25 and 30 min. Information regarding optimal conditions for its application was then obtained. After which, correlation between voltages and time with CF concentration in the bone was analysed. A bioavailability test was also conducted to observe the optimal rate of CF elution from the graft.

    RESULT: The optimal condition for the impregnation process is 3% CF at 90 V for 10 min. Bone graft impregnated with CF at optimal conditions can elute above minimum inhibitory concentration of the CF against MRSA for 21 days.

    CONCLUSION: CF iontophoresis was found feasible for allograft impregnation. The technique is simple, inexpensive and reproducible clinically. Iontophoresis offers a novel solution to reduce the rate of perioperative infection in reconstructive surgery involving use of bone graft.

  15. Shivdas S, Hashim MS, Ahmad TS
    J Orthop Surg (Hong Kong), 2018 10 4;26(3):2309499018802504.
    PMID: 30278809 DOI: 10.1177/2309499018802504
    PURPOSE: Our primary objectives were to create a reliable, noninvasive method for three-dimensional morphometry of deep bony parameters within the sigmoid notch of the distal radius, to identify its morphological patterns, and to identify any significant variation between the left and the right wrists. Our secondary objectives were to obtain morphometric values that could represent our population and to identify any possible ethnic variations.

    METHODS: Computed tomography scans of 102 wrists from 51 healthy individuals were analyzed using a virtualization software. Four anatomical parameters at the distal radius sigmoid notch, namely, the radius of curvature, depth, version angle, and sagittal slope were measured. Morphological patterns of the sigmoid notch surface were identified. The results were statistically analyzed to assess the reliability of the technique and were compared with previously published literature.

    RESULTS: Comparing our findings with previously published values, our study revealed a slightly larger radius of curvature and sagittal slope, while revealing a smaller depth and version. We identified the S-type, C-type, and ski-slope morphological variants. The flat-face morphological variant, however, was not identified. The sigmoid notch at the left and right wrists were similar, except for the radius of curvature.

    CONCLUSION: This study demonstrates a noninvasive, fast, reliable, and reproducible technique for analyzing the sigmoid notch of the distal radius. In wrist injuries with intact distal radius sigmoid notch but involving comminuted fractures of the ulnar head, ulnar head replacement may be indicated. In such cases, analysis of the ipsilateral intact sigmoid notch would allow us to prepare an ulnar head prosthesis of appropriate size.

  16. Shanmugam R, Jian CYCCS, Haseeb A, Aik S
    J Orthop Surg (Hong Kong), 2018 10 3;26(3):2309499018802511.
    PMID: 30270746 DOI: 10.1177/2309499018802511
    PURPOSE: Metacarpal bone fractures constitute 10% of all fractures. Unstable metacarpal fractures require surgical intervention, which poses danger to flexor tendon either due to bicortical drilling or construct of the implant. Unicortical locking plate fixation may be the solution to preventing flexor tendon injury. Studies have compared locking and compression plates. However, in these studies, the biomechanical properties were tested using the static loading method. This study looks into cyclical loading that is more representative of in vivo conditions, particularly for early rehabilitation. We compared the biomechanical strength of the unicortical locking plate and bicortical compression plate system in a transverse metacarpal fracture, tested with cyclical loading and torsion.

    METHOD: Twenty pieces of fourth-generation, biomechanical testing grade, left third metacarpal composite bones were used. Resin was used to create the holding block at both ends of the bone. An oscillating saw with 0.8 mm thick saw blade was used to osteotomize the metacarpal sawbones to create a midshaft transverse metacarpal fracture model. Ten pieces were fixed with a 2.0 mm titanium locking plate via unicortical screw purchase and 10 were fixed with a 2.0 mm, four holes, titanium dynamic compression plate, bicortical purchase of screws. They were subjected to cyclic load to failure testing three-point bending and torsion.

    RESULTS: There were no significant difference in stiffness and cyclic three-point bending to failure between the unicortical locking plate group and the bicortical compression plate group. The bicortical compression plate group is stiffer and has a higher cyclic bending load to failure as compared to the unicortical locking plate group.

    CONCLUSION: Unicortical locking plate fixation of metacarpal fracture can be reliably applied clinically to produce a strong and stable construct that allows early mobilization of the joints. This will not only reduce the complication rate of metacarpal plating, but also improve the functional outcome of the hand.

  17. Ong EKS, Wong TS, Chung WH, Chiu CK, Saw A, Hasan MS, et al.
    J Orthop Surg (Hong Kong), 2019 10 17;27(3):2309499019879213.
    PMID: 31615339 DOI: 10.1177/2309499019879213
    Aberrant left brachiocephalic vein is a rare condition. Its occurrence in patients requiring anterior cervicothoracic approach for severe kyphoscoliosis has not been described. A 16-year-old male with neurofibromatosis and severe upper thoracic kyphoscoliosis presented to us with curve progression. Halo gravity traction was attempted but failed to achieve significant correction. Subsequently, he underwent halo-pelvic traction and later Posterior Spinal Fusion (PSF) from C2 to T10. Second-stage anterior cervicothoracic approach with anterior fibula strut grafting was planned; however, preoperative computed tomography angiography revealed an aberrant left brachiocephalic vein with an anomalous retrotracheal and retroesophageal course, directly anterior to the T5/T6 vertebrae (planned anchor site for fibula strut graft) before draining into superior vena cava. Therefore, surgery was abandoned due to the risks associated with this anomaly. Aberrant left brachiocephalic vein is rare, the presence of which could be a contraindication for anterior cervicothoracic approach. Assessment of the anterior neurovascular structures is crucial in preoperative planning.
  18. Ajit Singh V, Earnest Kunasingh D, Haseeb A, Yasin NF
    J Orthop Surg (Hong Kong), 2019 5 30;27(2):2309499019850313.
    PMID: 31138060 DOI: 10.1177/2309499019850313
    PURPOSE: Expandable endoprosthesis allows limb salvage in children with an option to leading a better life. However, the revision rate and implant-related complications impose as a limitation in the skeletal immature. This study investigates the functional outcomes and complications related to expandable endoprosthesis in our centre.

    MATERIALS AND METHODS: Twenty surviving patients with expandable endoprosthesis from 2006 till 2015 were scored using Musculoskeletal Tumour Society (MSTS) outcomes instrument and reviewed retrospectively for range of motion of respected joints, limb length discrepancy, number of surgeries performed, complications and oncological outcomes. Patients with less than 2 years of follow-up were excluded from this study.

    RESULTS: Forty-five percentage patients reached skeletal maturity with initial growing endoprosthesis and 25% of patients were revised to adult modular prosthesis. One hundred fifty-seven surgeries were performed over the 9-year period. The average MSTS score was 90.83%. The mortality rate was 10% within 5 years due to advanced disease. Infection and implant failure rate was 15% each. The event-free survival was 50% and overall survival rate was 90%.

    CONCLUSION: There is no single best option for reconstruction in skeletally immature. This study demonstrates a favourable functional and survival outcome of paediatric patients with expandable endoprosthesis. The excellent MSTS functional scores reflect that patients were satisfied and adjusted well to activities of daily living following surgery despite the complications.

  19. Haseeb A, Ajit Singh V, Teh CSJ, Loke MF
    J Orthop Surg (Hong Kong), 2019 5 30;27(2):2309499019850324.
    PMID: 31138005 DOI: 10.1177/2309499019850324
    BACKGROUND: Ceftaroline is a cephalosporin that is effective against methicillin-resistant Staphylococcus aureus (MRSA) infections. The objective of this study was to determine the feasibility of using ceftaroline-loaded Polymethyl methacrylate (PMMA) as antibiotic cement against MRSA versus vancomycin-loaded PMMA in an in vitro setting.

    METHODS: PMMA pellets were prepared with three separate concentrations of each of the two antibiotics tested. They were tested to determine the effect of increasing concentration of antibiotics on the biomechanical properties of PMMA and antibiotic activity by measuring the zone of inhibition and broth elution assay.

    RESULTS: Ceftaroline PMMA at 3 wt%, three-point bending was 37.17 ± 0.51 N ( p < 0.001) and axial loading was 41.95 N ± 0.51 ( p < 0.001). At 5-wt% vancomycin-PMMA, three-point bending was 41.65 ± 0.79 N ( p = 0.02) and axial loading was 49.49 ± 2.21 N ( p = 0.01). Stiffness of ceftroline-loaded PMMA in low and medium concentration was significantly higher than the vancomycin. The zone of inhibition for ceftaroline was higher than vancomycin. Ceftaroline at 3 wt% eluted up to 6 weeks (0.3 ± 0.1 μg/ml) above the minimum inhibitory concentration (MIC) and vancomycin at 2.5 wt% eluted up to 3 weeks, same as MIC, that is, 0.5 ± 0.0 μg/ml.

    CONCLUSIONS: Ceftaroline, loaded at similar concentrations as vancomycin into PMMA, is a more potent alternative based on its more favourable bioactivity and elution properties, while having a lesser effect on the mechanical properties of the cement. The use of 3-wt% ceftaroline as antibiotic laden PMMA against MRSA is recommended. It should be noted that this was an in vitro study and to determine the clinical efficacy would need prospective, controlled and randomized studies.