Displaying publications 61 - 80 of 251 in total

Abstract:
Sort:
  1. Sermon A, Hofmann-Fliri L, Zderic I, Agarwal Y, Scherrer S, Weber A, et al.
    Medicina (Kaunas), 2021 Aug 28;57(9).
    PMID: 34577822 DOI: 10.3390/medicina57090899
    Background and Objectives: Hip fractures constitute the most debilitating complication of osteoporosis with steadily increasing incidences in the aging population. Their intramedullary nailing can be challenging because of poor anchorage in the osteoporotic femoral head. Cement augmentation of Proximal Femoral Nail Antirotation (PFNA) blades demonstrated promising results by enhancing cut-out resistance in proximal femoral fractures. The aim of this study was to assess the impact of augmentation on the fixation strength of TFN-ADVANCEDTM Proximal Femoral Nailing System (TFNA) blades and screws within the femoral head and compare its effect when they are implanted in centre or anteroposterior off-centre position. Materials and Methods: Eight groups were formed out of 96 polyurethane low-density foam specimens simulating isolated femoral heads with poor bone quality. The specimens in each group were implanted with either non-augmented or cement-augmented TFNA blades or screws in centre or anteroposterior off-centre positions, 7 mm anterior or posterior. Mechanical testing was performed under progressively increasing cyclic loading until failure, in setup simulating an unstable pertrochanteric fracture with a lack of posteromedial support and load sharing at the fracture gap. Varus-valgus and head rotation angles were monitored. A varus collapse of 5° or 10° head rotation was defined as a clinically relevant failure. Results: Failure load (N) for specimens with augmented TFNA head elements (screw/blade centre: 3799 ± 326/3228 ± 478; screw/blade off-centre: 2680 ± 182/2591 ± 244) was significantly higher compared with respective non-augmented specimens (screw/blade centre: 1593 ± 120/1489 ± 41; screw/blade off-centre: 515 ± 73/1018 ± 48), p < 0.001. For both non-augmented and augmented specimens failure load in the centre position was significantly higher compared with the respective off-centre positions, regardless of the head element type, p < 0.001. Augmented off-centre TFNA head elements had significantly higher failure load compared with non-augmented centrally placed implants, p < 0.001. Conclusions: Cement augmentation clearly enhances the fixation stability of TFNA blades and screws. Non-augmented blades outperformed screws in the anteroposterior off-centre position. Positioning of TFNA blades in the femoral head is more forgiving than TFNA screws in terms of failure load.
    Matched MeSH terms: Biomechanical Phenomena
  2. Al-Fakih EA, Abu Osman NA, Mahmad Adikan FR
    Sensors (Basel), 2016 Jul 20;16(7).
    PMID: 27447646 DOI: 10.3390/s16071119
    The distribution of interface stresses between the residual limb and prosthetic socket of a transtibial amputee has been considered as a direct indicator of the socket quality fit and comfort. Therefore, researchers have been very interested in quantifying these interface stresses in order to evaluate the extent of any potential damage caused by the socket to the residual limb tissues. During the past 50 years a variety of measurement techniques have been employed in an effort to identify sites of excessive stresses which may lead to skin breakdown, compare stress distributions in various socket designs, and evaluate interface cushioning and suspension systems, among others. The outcomes of such measurement techniques have contributed to improving the design and fitting of transtibial sockets. This article aims to review the operating principles, advantages, and disadvantages of conventional and emerging techniques used for interface stress measurements inside transtibial sockets. It also reviews and discusses the evolution of different socket concepts and interface stress investigations conducted in the past five decades, providing valuable insights into the latest trends in socket designs and the crucial considerations for effective stress measurement tools that lead to a functional prosthetic socket.
    Matched MeSH terms: Biomechanical Phenomena
  3. Azizan NA, Basaruddin KS, Salleh AF
    Appl Bionics Biomech, 2018;2018:5156348.
    PMID: 30116295 DOI: 10.1155/2018/5156348
    Various studies have examined body posture stability, including postural sway and associated biomechanical parameters, to assess the severity effects of leg length discrepancy (LLD). However, various viewpoints have been articulated on the results of these studies because of certain drawbacks in the comprehensive analysis of the effect of variations in LLD magnitude. Therefore, this systematic review was performed to help focus on the current findings to help identify which biomechanical parameters are most relevant, commonly used, and able to distinguish and/or have specific clinical relevance to the effect of variations in LLD magnitude during static (standing) and dynamic (walking) conditions. Several electronic databases containing studies from the year 1983 to 2016 (Scopus, ScienceDirect, PubMed, PMC, and ProQuest) were obtained in our literature search. The search process yielded 22 published articles that fulfilled our criteria. We found most of the published data that we analyzed to be inconsistent, and very little data was obtained on the correlation between LLD severity and changes in body posture stability during standing and walking. However, the results of the present review study are in line with previous observational studies, which describe asymmetry in the lower limbs corresponding to biomechanical parameters such as gait kinematics, kinetics, and other parameters described during static (standing) postural balance. In future investigations, we believe that it might be useful to use and exploit other balance-related factors that may potentially influence body posture stability.
    Matched MeSH terms: Biomechanical Phenomena
  4. Ali Md Nadzalan, Muhammad Hannan Sazali, Mohamad Shahrul Azzfar
    MyJurnal
    As a way to enhance performance in sports, apart from in-field or in court training, athletes are recommended to adopt resistance training into their training routine. As an exercise that needs the performer to split their legs, lunge is suggested to be included as an exercise in a training session. Various researches had been conducted on lunge and several findings showed different methods or protocols of lunge affect the kinematics, kinetics muscle activation and fascicle behaviour response during the exercise. Although not much study conducted on the chronic adaptations, the existing studies suggested that performers should well plan the training protocols as this will cause different training adaptations.
    Matched MeSH terms: Biomechanical Phenomena
  5. Khachatryan V, Sirunyan AM, Tumasyan A, Adam W, Asilar E, Bergauer T, et al.
    Eur Phys J C Part Fields, 2017;77(11):751.
    PMID: 31999282 DOI: 10.1140/epjc/s10052-017-5140-y
    Measurements of the associated production of a
    Z
    boson with at least one jet originating from a b quark in proton-proton collisions at


    s

    =
    8

    TeV

    are presented. Differential cross sections are measured with data collected by the CMS experiment corresponding to an integrated luminosity of 19.8



    fb

    -
    1



    .
    Z
    bosons are reconstructed through their decays to electrons and muons. Cross sections are measured as a function of observables characterizing the kinematics of the
    b
    jet and the
    Z
    boson. Ratios of differential cross sections for the associated production with at least one
    b
    jet to the associated production with any jet are also presented. The production of a
    Z
    boson with at least two
    b
    jets is investigated, and differential cross sections are measured for the dijet system. Results are compared to theoretical predictions, testing two different flavour schemes for the choice of initial-state partons.
    Matched MeSH terms: Biomechanical Phenomena
  6. Mohd Safee MK, Abu Osman NA
    Occup Ther Int, 2021;2021:4357473.
    PMID: 34707468 DOI: 10.1155/2021/4357473
    Muscle fatigue is a decline in muscle maximum force during contraction and can influence the fall risk among people. This study is aimed at identifying the effect of fatigue on prospective fall risk in transfemoral amputees (TFA). Fourteen subjects were involved in this study with TFA (34.7 ± 8.1 yrs, n = 7) and normal subjects (31.1 ± 7.4 yrs, n = 7). Fatigue of lower limb muscles was induced with the fatigue protocol. Subjects were tested prefatigue and postfatigue using the standardized fall risk assessment. All results were calculated and compared between pre- and postfatigue to identify fatigue's effect on both groups of subjects. The results showed that the fall risk increased significantly during pre- and postfatigue for TFA (p = 0.018), while there were no significant differences in normal subjects (p = 0.149). Meanwhile, the fall risk between TFA and normal subjects for prefatigue (p = 0.082) and postfatigue (p = 0.084) also showed no significant differences. The percentage (%) of increased fall risk for TFA was 19.2% compared to normal subjects only 16.7%. However, 61.4% increased of % fall risk in TFA after fatigue by using the baseline of the normal subject as the normalized % of fall risk. The increasing fall risks for TFA after fatigue are three times higher than the potential fall risk in normal subjects. The result indicates that they need to perform more precautions while prolonging lower limb activities. These results showed the implications of fatigue that can increase the fall risk due to muscle fatigue from repetitive and prolonged activities. Therefore, rehabilitation programs can be done very safely and precisely so that therapists can pursue fitness without aggravating existing injuries.
    Matched MeSH terms: Biomechanical Phenomena
  7. Sirunyan AM, Tumasyan A, Adam W, Asilar E, Bergauer T, Brandstetter J, et al.
    Phys Rev Lett, 2017 Oct 13;119(15):152301.
    PMID: 29077459 DOI: 10.1103/PhysRevLett.119.152301
    The differential production cross sections of B^{±} mesons are measured via the exclusive decay channels B^{±}→J/ψK^{±}→μ^{+}μ^{-}K^{±} as a function of transverse momentum in pp and Pb-Pb collisions at a center-of-mass energy sqrt[s_{NN}]=5.02  TeV per nucleon pair with the CMS detector at the LHC. The pp(Pb-Pb) data set used for this analysis corresponds to an integrated luminosity of 28.0  pb^{-1} (351  μb^{-1}). The measurement is performed in the B^{±} meson transverse momentum range of 7 to 50  GeV/c, in the rapidity interval |y|<2.4. In this kinematic range, a strong suppression of the production cross section by about a factor of 2 is observed in the Pb-Pb system in comparison to the expectation from pp reference data. These results are found to be roughly compatible with theoretical calculations incorporating beauty quark diffusion and energy loss in a quark-gluon plasma.
    Matched MeSH terms: Biomechanical Phenomena
  8. Khachatryan V, Sirunyan AM, Tumasyan A, Adam W, Asilar E, Bergauer T, et al.
    Eur Phys J C Part Fields, 2016;76(7):401.
    PMID: 28286414 DOI: 10.1140/epjc/s10052-016-4219-1
    A measurement of the W boson pair production cross section in proton-proton collisions at [Formula: see text] TeV is presented. The data collected with the CMS detector at the LHC correspond to an integrated luminosity of 19.4[Formula: see text]. The [Formula: see text] candidates are selected from events with two charged leptons, electrons or muons, and large missing transverse energy. The measured [Formula: see text] cross section is [Formula: see text], consistent with the standard model prediction. The [Formula: see text] cross sections are also measured in two different fiducial phase space regions. The normalized differential cross section is measured as a function of kinematic variables of the final-state charged leptons and compared with several perturbative QCD predictions. Limits on anomalous gauge couplings associated with dimension-six operators are also given in the framework of an effective field theory. The corresponding 95 % confidence level intervals are [Formula: see text], [Formula: see text], [Formula: see text], in the HISZ basis.
    Matched MeSH terms: Biomechanical Phenomena
  9. Abd Rahman NA, Li S, Schmid S, Shaharudin S
    Phys Ther Sport, 2023 Jan;59:60-72.
    PMID: 36516512 DOI: 10.1016/j.ptsp.2022.11.011
    Low back pain (LBP) can result in increased direct medical and non-medical costs to patients, employers, and health care providers. This systematic review aimed to provide a better understanding of the biomechanical factors associated with chronic non-specific LBP in adults. SCOPUS, ScienceDirect, MEDLINE, and Web of Science databases were searched. In total, 26 studies were included and significant differences were noted between healthy controls and LBP patients in various motion. Biomechanical factors among adults with non-specific LBP were altered and differed as compared to healthy controls in various motion might be to compensate the pain during those motions. This review highlighted the biomechanical differences across those with non-specific LBP and healthy adults. Both groups showed a similar level of pain during functional tasks but LBP patients suffered from a moderate level of disability. Future studies should not rely on questionnaire-based pain scale only. The biomechanical factors summarized in this review can be used to diagnose non-specific LBP accurately, and as modifiable targets for exercise-based intervention.
    Matched MeSH terms: Biomechanical Phenomena
  10. Robinson MA, Sharir R, Rafeeuddin R, Vanrenterghem J, Donnelly CJ
    Sports Biomech, 2023 Jan;22(1):80-90.
    PMID: 33947315 DOI: 10.1080/14763141.2021.1903981
    Multi-planar forces and moments are known to injure the anterior cruciate ligament (ACL). In ACL injury risk studies, however, the uni-planar frontal plane external knee abduction moment is frequently studied in isolation. This study aimed to determine if the frontal plane knee moment (KM-Y) could classify all individuals crossing a risk threshold compared to those classified by a multi-planar non-sagittal knee moment vector (KM-YZ). Recreationally active females completed three sports tasks-drop vertical jumps, single-leg drop vertical jumps and planned sidesteps. Peak knee abduction moments and peak non-sagittal resultant knee moments were obtained for each task, and a risk threshold of the sample mean plus 1.6 standard deviations was used for classification. A sensitivity analysis of the threshold from 1-2 standard deviations was also conducted. KM-Y did not identify all participants who crossed the risk threshold as the non-sagittal moment identified unique individuals. This result was consistent across tasks and threshold sensitivities. Analysing the peak uni-planar knee abduction moment alone is therefore likely overly reductionist, as this study demonstrates that a KM-YZ threshold identifies 'at risk' individuals that a KM-Y threshold does not. Multi-planar moment metrics such as KM-YZ may help facilitate the development of screening protocols across multiple tasks.
    Matched MeSH terms: Biomechanical Phenomena
  11. Yunus MNH, Jaafar MH, Mohamed ASA, Azraai NZ, Amil N, Zein RM
    Int J Environ Res Public Health, 2022 Oct 31;19(21).
    PMID: 36361112 DOI: 10.3390/ijerph192114232
    Back injury is a common musculoskeletal injury reported among firefighters (FFs) due to their nature of work and personal protective equipment (PPE). The nature of the work associated with heavy lifting tasks increases FFs' risk of back injury. This study aimed to assess the biomechanics movement of FFs on personal protective equipment during a lifting task. A set of questionnaires was used to identify the prevalence of musculoskeletal pain experienced by FFs. Inertial measurement unit (IMU) motion capture was used in this study to record the body angle deviation and angular acceleration of FFs' thorax extension. The descriptive analysis was used to analyze the relationship between the FFs' age and body mass index with the FFs' thorax movement during the lifting task with PPE and without PPE. Sixty-three percent of FFs reported lower back pain during work, based on the musculoskeletal pain questionnaire. The biomechanics analysis of thorax angle deviation and angular acceleration has shown that using FFs PPE significantly causes restricted movement and limited mobility for the FFs. As regards human factors, the FFs' age influences the angle deviation while wearing PPE and FFs' BMI influences the angular acceleration without wearing PPE during the lifting activity.
    Matched MeSH terms: Biomechanical Phenomena
  12. Yap YT, Gouwanda D, Gopalai AA, Chong YZ
    J Biomech Eng, 2023 Feb 01;145(2).
    PMID: 36082472 DOI: 10.1115/1.4055564
    Musculoskeletal modeling and simulation have been an emerging trend in human gait analysis. It allows the user to isolate certain biomechanical conditions and elucidate the dynamics of joints and muscles. This study used an open-source musculoskeletal modeling and simulation tool, opensim to investigate the biomechanical effect of knee brace. It collected gait data from thirty-eight participants and examined the gait spatio-temporal parameters, joint angles, and joint moments. Static optimization was performed to estimate the lower extremity muscle force. Statistical analysis was conducted to identify the difference between normal and braced gaits. The results demonstrated the feasibility of this method to investigate the interaction and coordination of lower extremity joints and muscles. The knee brace constrained the range of the motion of the knee during walking. It also changed the walking speed, step length, and stance-to-swing ratio. Several significant differences were found in the joint moments and muscle forces of the rectus femoris, gastrocnemius, soleus and tibialis anterior. Musculoskeletal modeling and simulation tool offers a less invasive and practical alternative to analyze human motion. It also provides a means to investigate the effect of medical devices such as knee brace, which can be potentially beneficial for the future design and development of such devices and for the derivation of future rehabilitation treatment to improve patient's gait.
    Matched MeSH terms: Biomechanical Phenomena
  13. Hashim MH, Teo SH, Al-Fayyadh MZM, Mappiare S, Ng WM, Ali MRM
    Injury, 2022 Feb;53(2):393-398.
    PMID: 34740441 DOI: 10.1016/j.injury.2021.10.016
    INTRODUCTION: To compare the strength between the Achilles tendons repaired with the "Giftbox" and the Krackow techniques in New Zealand white rabbits post six weeks of tendon healing.

    MATERIALS AND METHODS: Eight rabbits were randomized into Giftbox and Krackow groups. Tenotomy was performed on the Achilles tendon of one side of the lower limb and repaired with the respective techniques. The contralateral limb served as control. Subjects were euthanized six weeks post-operative, and both repaired and control Achilles tendons were harvested for biomechanical tensile test.

    RESULTS: The means of maximum load to rupture and tenacity in the Giftbox group (156.89 ± 38.49 N and 159.98 ± 39.25 gf/tex) were significantly different than Krackow's (103.55 ± 27.48 N and 104.91 ± 26.96 gf/tex, both p = 0.043).

    CONCLUSION: The tendons repaired with Giftbox technique were biomechanically stronger than those repaired with Krackow technique after six weeks of tendon healing.

    Matched MeSH terms: Biomechanical Phenomena
  14. Abdul Yamin NAA, Basaruddin KS, Abu Bakar S, Salleh AF, Mat Som MH, Yazid H, et al.
    J Healthc Eng, 2022;2022:7716821.
    PMID: 36275397 DOI: 10.1155/2022/7716821
    This study aims to investigate the gait stability response during incline and decline walking for various surface inclination angles in terms of the required coefficient of friction (RCOF), postural stability index (PSI), and center of pressure (COP)-center of mass (COM) distance. A customized platform with different surface inclinations (0°, 5°, 7.5°, and 10°) was designed. Twenty-three male volunteers participated by walking on an inclined platform for each inclination. The process was then repeated for declined platform as well. Qualysis motion capture system was used to capture and collect the trajectories motion of ten reflective markers that attached to the subjects before being exported to a visual three-dimensional (3D) software and executed in Matlab to obtain the RCOF, PSI, as well as dynamic PSI (DPSI) and COP-COM distance parameters. According to the result for incline walking, during initial contact, the RCOF was not affected to inclination. However, it was affected during peak ground reaction force (GRF) starting at 7.5° towards 10° for both walking conditions. The most affected PSI was found at anterior-posterior PSI (APSI) even as low as 5° inclination during both incline and decline walking. On the other hand, DPSI was not affected during both walking conditions. Furthermore, COP-COM distance was most affected during decline walking in anterior-posterior direction. The findings of this research indicate that in order to decrease the risk of falling and manage the inclination demand, a suitable walking strategy and improved safety measures should be applied during slope walking, particularly for decline and anterior-posterior orientations. This study also provides additional understanding on the best incline walking technique for secure and practical incline locomotion.
    Matched MeSH terms: Biomechanical Phenomena
  15. Teoh YX, Alwan JK, Shah DS, Teh YW, Goh SL
    Clin Biomech (Bristol, Avon), 2024 Mar;113:106188.
    PMID: 38350282 DOI: 10.1016/j.clinbiomech.2024.106188
    BACKGROUND: Despite the existence of evidence-based rehabilitation strategies that address biomechanical deficits, the persistence of recurrent ankle problems in 70% of patients with acute ankle sprains highlights the unresolved nature of this issue. Artificial intelligence (AI) emerges as a promising tool to identify definitive predictors for ankle sprains. This paper aims to summarize the use of AI in investigating the ankle biomechanics of healthy and subjects with ankle sprains.

    METHODS: Articles published between 2010 and 2023 were searched from five electronic databases. 59 papers were included for analysis with regards to: i). types of motion tested (functional vs. purposeful ankle movement); ii) types of biomechanical parameters measured (kinetic vs kinematic); iii) types of sensor systems used (lab-based vs field-based); and, iv) AI techniques used.

    FINDINGS: Most studies (83.1%) examined biomechanics during functional motion. Single kinematic parameter, specifically ankle range of motion, could obtain accuracy up to 100% in identifying injury status. Wearable sensor exhibited high reliability for use in both laboratory and on-field/clinical settings. AI algorithms primarily utilized electromyography and joint angle information as input data. Support vector machine was the most used supervised learning algorithm (18.64%), while artificial neural network demonstrated the highest accuracy in eight studies.

    INTERPRETATIONS: The potential for remote patient monitoring is evident with the adoption of field-based devices. Nevertheless, AI-based sensors are underutilized in detecting ankle motions at risk of sprain. We identify three key challenges: sensor designs, the controllability of AI models, and the integration of AI-sensor models, providing valuable insights for future research.

    Matched MeSH terms: Biomechanical Phenomena
  16. Donnelly CJ, Weir G, Jackson C, Alderson J, Rafeeuddin R, Sharir R, et al.
    Sports Biomech, 2024 Mar;23(3):324-334.
    PMID: 33886425 DOI: 10.1080/14763141.2020.1860254
    Much inter-intra-tester kinematic and kinetic repeatability research exists, with a paucity investigating inter-laboratory equivalence. The objective of this research was to evaluate the inter-laboratory equivalence between time varying unplanned kinematics and moments of unplanned sidestepping (UnSS). Eight elite female athletes completed an established UnSS procedure motion capture laboratories in the UK and Australia. Three dimensional time varying unplanned sidestepping joint kinematics and moments were compared. Discrete variables were change of direction angles and velocity. Waveform data were compared using mean differences, 1D 95%CI and RMSE. Discrete variables were compared using 0D 95% CI. The mean differences and 95%CI for UnSS kinematics broadly supported equivalence between laboratories (RMSE≤5.1°). Excluding hip flexion/extension moments (RMSE = 1.04 Nm/kg), equivalence was also supported for time varying joint moments between laboratories (RMSE≤0.40 Nm/kg). Dependent variables typically used to characterise UnSS were also equivalent. When consistent experimental and modelling procedures are employed, consistent time varying UnSS lower limb joint kinematic and moment estimates between laboratories can be obtained. We therefore interpret these results as a support of equivalence, yet highlight the challenges of establishing between-laboratory experiments or data sharing, as well as establishing appropriate ranges of acceptable uncertainty. These findings are important for data sharing and multi-centre trials.
    Matched MeSH terms: Biomechanical Phenomena
  17. Ibitoye MO, Hamzaid NA, Zuniga JM, Abdul Wahab AK
    Clin Biomech (Bristol, Avon), 2014 Jun;29(6):691-704.
    PMID: 24856875 DOI: 10.1016/j.clinbiomech.2014.04.003
    Previous studies have explored to saturation the efficacy of the conventional signal (such as electromyogram) for muscle function assessment and found its clinical impact limited. Increasing demand for reliable muscle function assessment modalities continues to prompt further investigation into other complementary alternatives. Application of mechanomyographic signal to quantify muscle performance has been proposed due to its inherent mechanical nature and ability to assess muscle function non-invasively while preserving muscular neurophysiologic information. Mechanomyogram is gaining accelerated applications in evaluating the properties of muscle under voluntary and evoked muscle contraction with prospects in clinical practices. As a complementary modality and the mechanical counterpart to electromyogram; mechanomyogram has gained significant acceptance in analysis of isometric and dynamic muscle actions. Substantial studies have also documented the effectiveness of mechanomyographic signal to assess muscle performance but none involved comprehensive appraisal of the state of the art applications with highlights on the future prospect and potential integration into the clinical practices. Motivated by the dearth of such critical review, we assessed the literature to investigate its principle of acquisition, current applications, challenges and future directions. Based on our findings, the importance of rigorous scientific and clinical validation of the signal is highlighted. It is also evident that as a robust complement to electromyogram, mechanomyographic signal may possess unprecedented potentials and further investigation will be enlightening.
    Matched MeSH terms: Biomechanical Phenomena/physiology
  18. Low TH, Ahmad TS, Ng ES
    J Hand Surg Eur Vol, 2012 Feb;37(2):101-8.
    PMID: 21636621 DOI: 10.1177/1753193411409840
    We have compared a simple four-strand flexor tendon repair, the single cross-stitch locked repair using a double-stranded suture (dsSCL) against two other four-strand repairs: the Pennington modified Kessler with double-stranded suture (dsPMK); and the cruciate cross-stitch locked repair with single-stranded suture (Modified Sandow). Thirty fresh frozen cadaveric flexor digitorum profundus tendons were transected and repaired with one of the core repair techniques using identical suture material and reinforced with identical peripheral sutures. Bulking at the repair site and tendon-suture junctions was measured. The tendons were subjected to linear load-to-failure testing. Results showed no significant difference in ultimate tensile strength between the Modified Sandow (36.8 N) and dsSCL (32.6 N) whereas the dsPMK was significantly weaker (26.8 N). There were no significant differences in 2 mm gap force, stiffness or bulk between the three repairs. We concluded that the simpler dsSCL repair is comparable to the modified Sandow repair in tensile strength, stiffness and bulking.
    Matched MeSH terms: Biomechanical Phenomena/physiology
  19. Amiri-Khorasani M, Abu Osman NA, Yusof A
    J Strength Cond Res, 2011 Apr;25(4):1177-81.
    PMID: 20838249 DOI: 10.1519/JSC.0b013e3181d6508c
    This study investigated the number of trials necessary to obtain optimal biomechanical responses in 10 consecutive soccer instep kicks. The kicking motions of dominant legs were captured from 5 experienced and skilled adult male soccer players (height: 184.60 ± 4.49 cm; mass: 80 ± 4.24 kg; and age: 25.60 ± 1.14 years) using a 3D infrared high-speed camera at 200 Hz. Some of the important kinematics and kinetics parameters are maximum thigh angular velocity, maximum lower leg angular velocity, maximum of thigh moment, maximum lower leg moment at forward and impact phases, and finally maximum ball velocity after impact selected to be analyzed. There was a significant decrease of ball velocity between the first and the fifth kick and the subsequent kicks. Similarly, the lower leg angular velocity showed a significant decrease after the fifth kick and thereafter. Compared with the first kick, the thigh angular velocity has been shown to decrease after the sixth kick and thereafter, and the thigh moment result of the sixth kick was significantly lower when compared with the first kick. Moreover, the lower leg moment result of the fourth kick was significantly lower in comparison with the first kick. In conclusion, it seems that 5 consecutive kicks are adequate to achieve high kinematics and kinetics responses and selecting more than 5 kicks does not result in any high biomechanical responses for analysis.
    Matched MeSH terms: Biomechanical Phenomena/physiology
  20. Daneshjoo A, Mokhtar AH, Rahnama N, Yusof A
    PLoS One, 2012;7(12):e51568.
    PMID: 23251579 DOI: 10.1371/journal.pone.0051568
    The study investigated the effects of FIFA 11+ and HarmoKnee, both being popular warm-up programs, on proprioception, and on the static and dynamic balance of professional male soccer players.
    Matched MeSH terms: Biomechanical Phenomena/physiology
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links