Displaying publications 61 - 80 of 114 in total

Abstract:
Sort:
  1. Sulaiman, E., Yeo, Y.M., Chong, Y.T.
    Ann Dent, 2007;14(1):39-45.
    MyJurnal
    Purpose of the study: The objective of this study was to investigate the flexural strengths of five commercially available tooth-coloured restorative materials – Alpha-Dent (composite resin, Dental Technologies Inc.), Solare Anterior (composite resin, GC), F2000 (polyacid-modified composite resin, 3M), Beautifil (giomer, Shofu) and Fuji II LC (resin- modified glass ionomer cement, GC] using the ISO 4049 specifications. Materials and Method: Ten specimens of (25±0.2)mm x (2±0.1)mm x (2±0.1)mm from each material were prepared at 22-23ºC using a customized metal mould. After light polymerization, the specimens were stored in distilled water at 37ºC for 24 hours. The specimens were subsequently blotted dry, measured and subjected to flexural testing using an Instron Universal Testing Machine with a crosshead speed of 0.5mm/min. The flexural strengths were calculated from the maximum load exerted on the specimens. Data were analysed using one way ANOVA and scheffe’s post-hoc multiple comparison tests at a significance level of 0.05.Results: The results showed that the mean flexural strengths of Beautifil, Solare Anterior and Alpha-Dent were above 80 MPa and those of F2000 and Fuji II LC were below 80 MPa. The results of one-way ANOVA and Scheffe’s post-host tests demonstrated that Beautifil had significantly higher mean flexural strength compared to Fuji II LC, F2000 and Alpha-Dent (P
    Matched MeSH terms: Composite Resins
  2. Chong SY, Lim TB, Seow LL
    Malaysian Dental Journal, 2008;29(2):97-103.
    MyJurnal
    Objectives: The objectives of the study were to assess: i) the staining susceptibility of composite resins, ii) the ability of whitening toothpastes in removing stains from composite resins.
    Materials and Methods: Thirty specimens from each composite resins: Filtek Z350 (3M ESPE), Filtek Z250 (3M ESPE) and Beautifil (Shofu Inc.) were fabricated. After polishing, specimens were immersed in coffee for 3 days. Specimens were then brushed twice a day for 2 weeks using Colgate Total (Colgate-Palmolive, control group), Colgate Advanced Whitening (Colgate- Palmolive, test group) and Darlie All Shiny White (Hawley & Hazel Chemical Co., test group). Colour changes (?E*) were measured using Spectrophotometer at baseline, after coffee immersion and after brushing. Results were statistically analyzed using one way ANOVA and Tukey’s test.
    Results: There was significant difference in terms of colour changes for Filtek Z350, Filtek Z250 and Beautifil after coffee immersion (P0.05).
    Conclusions: Filtek Z350 was able to resist staining by coffee better than Filtek Z250 and Beautifil. The whitening toothpastes did not offer added advantage in terms of ability to remove stains compared to ordinary toothpaste.
    Matched MeSH terms: Composite Resins
  3. Suhaida Sabdi, Wan Zaripah Wan Bakar, Adam Husein
    MyJurnal
    Some restorative materials are susceptible to erosion but whether it also causes microleakage is still questionable. The aim of this study was to assess the microleakage of few restorative materials after immersion in acidic solution. Standardized ‘U’ shaped cavity of 4mm diameter and 2mm depth were prepared on buccal or lingual surface of 52 human premolar and molar teeth. The teeth were divided into 4 groups which contains 13 samples and 3 controls for each and were restored either with Filtek Z250 (Group 1), Fuji IX (Group 2), Fuji II LC (Group 3), or Silverfill amalgam (Group 4).
    All surfaces were painted with nail varnish leaving only 2mm of tooth structure surrounding the restoration before the study samples were immersed in acidic solution, lemon juice (pH 2.74) and control samples in deionised distilled water for 24 hours. Surface photos for erosion were taken before immersion in methylene blue for 7 days. After sectioning, the assessment of dye penetration was done using Leica Imaging System DMLM (Germany). Photos showed that Fuji IX demonstrated severe erosion but no obvious changes were seen on other materials. Kruskal-Wallis test indicated that microleakage between all four groups were statistically significant. The most significant difference was between Filtek Z250 and Fuji IX (p
    Matched MeSH terms: Composite Resins
  4. Michael, Mera Christina, Adam Husein, Wan Zaripah Wan Bakar, Eshamsul Sulaiman
    MyJurnal
    Endodontically treated teeth are generally weaker than sound teeth. The study objective was to compare the fracture resistance of endodontically treated teeth restored with different restorative techniques. Fifty extracted human maxillary central incisors of similar size were divided into five groups of 10 teeth. Group 1 was left intact as the control group. Other groups (Groups 2, 3, 4 and 5) were all endodontically treated followed by restorations using different restorative techniques; light cured composite resin (CR), CR and crown, post and CR, and post-CR core and crown respectively. The specimens were loaded in a universal testing machine with a static force at a crosshead speed of 0.5mm/min at 135 ° to the long axis of the root until failure. The means and the standard deviations of the maximum load at failure for groups 1, 2, 3, 4 and 5 were 1259.11N (379.12N), 578.63N (196.70N), 667.13N (298.72N), 1247.65N (294.48N) and 623.60N (193.75N) respectively. The results of one-way ANOVA showed statistically significant differences existed among the groups tested (p
    Matched MeSH terms: Composite Resins
  5. Lui, J.L., Chan, C.L., Yap, K.T.
    Ann Dent, 2006;13(1):6-11.
    MyJurnal
    The aim of the study was to determine the depth of cure of a new nanocomposite when exposed to different curing times and also when different shades were polymerized. The nanocomposite, Filtek Supreme (3M ESPE), was packed into 96 plastic cylindrical moulds measuring 4 mm in internal diameter and 8 mm in length and then polymerized using a conventional quartz-tungsten-halogen light curing unit. The first part of the study involved curing 16 samples each of A2 shade of the nanocomposite at exposure times of 20s, 40s, 60s and 120s. For the second part, a similar number of samples of the dentinal opacity shades of A2, B3 and A4 of the nanocomposite were polymerized at a constant exposure time of 40s. The depth of polymerization of the nanocomposite in each sample was measured using a digimatic indicator. Curing depths were found to increase significantly (P < 0.05) with longer exposure time (20s < 40s < 60s < 120s) and decrease significantly with darker shades (A2 > B3 > A4).
    Matched MeSH terms: Composite Resins
  6. Athirah Ab Rahman, Adam Husein, Hany Mohamed Aly Ahmed, Dasmawati Mohamad, Wan Zaripah Wan Bakar, Manal Farea, et al.
    MyJurnal
    Light intensity output is one of the determinants for adequate curing of visible light-cured materials. The aim of this survey was to evaluate the light intensity outputs (LIOs) of light curing units (LCUs) in dental clinics of Hospital Universiti Sains Malaysia (HUSM) and School of Dental Sciences, Universiti Sains Malaysia (USM). The respective LIOs of all functioning Quartz Tungsten Halogen (QTH) and Light Emitting Diode (LED) LCUs were tested using two light radiometers. For cordless LED LCUs, the testing procedure was done in situ and after being fully charged. Statistical analysis using Kruskal Wallis and Wilcoxon signed ranks tests were performed to compare the LIOs between groups and between the LIOs of in situ and post-charged cordless LED LCUs, respectively. The level of significance was set at 0.05 (p
    Matched MeSH terms: Composite Resins
  7. Mior Azrizal M. Ibrahim, Wan Zaripah Wan Bakar, Adam Husein
    MyJurnal
    Composite resins Amaris is claimed to have hydrophobic effect which minimizes the staining intake. This study is to investigate the colour stability of Amaris compared to Filtek Z250 in coffee solution. Sixty discs of composite resins Filtek Z250 (3M ESPE) and Amaris (Voco) with diameter of 5mm and depth of 2mm were fabricated by packing in a drinking straw and sectioned with hard tissue cutter (Exakt, Japan). The surfaces of the specimens were polished with Sof-Lex disc before each group of the samples is immersed in coffee solution. They were kept in the solution for 4 days at 370C and assessed at the period of 2 hours, 1 day, 2 days, 3 days, and 4 days. The staining was assessed visually and recorded using Lobene (1968) Stain Index and score was given accordingly. The colour changes of both groups were not statistically significant (p
    Matched MeSH terms: Composite Resins
  8. Chee HT, Wan Bakar WZ, Ghani ZA, Amaechi BT
    Dent Res J (Isfahan), 2018 6 21;15(3):215-219.
    PMID: 29922341
    Background: Composite resin (CR) currently is one of the most commonly used material in restoring noncarious cervical lesions (NCCL) due to its strength and esthetics color but has microleakage problem. The aim of this study is to compare in vitro the microleakage depth between CR and porcelain in restoring NCCL.

    Materials and Methods: This an in vitro study was done by preparing cavities on the buccocervical surface of 62 extracted premolar teeth which randomly assigned to two groups (n = 31) where Group 1 was restored with nanocomposite and Group 2 was cemented with porcelain cervical inlays. They were then subjected to thermocycling before immersion in 2% methylene blue dye for 24 h. Dye penetration depths were measured using Leica imaging system For statistical analysis, independent t-test was used to analyze the results (P < 0.05).

    Results: Porcelain cervical inlay restorations demonstrated statistically lesser microleakage depth for the cervical margins (P = 0.018) when compared to CR. Deeper microleakage depth at the cervical compared to coronal margins of CR (P = 0.006) but no significant difference of both margins for porcelain cervical inlays (P = 0.600).

    Conclusion: Porcelain cervical inlays show lesser microleakage than CR which could be alternative treatment option in restoring NCCL with better marginal seal and esthetics.

    Matched MeSH terms: Composite Resins
  9. Berhanuddin Muhamad Asyraf, Tong, Wah Lim
    Malaysian Dental Journal, 2016;2016(2):0-0.
    MyJurnal
    In nowadays world, aesthetic dentistry has becoming a trend with the improvement of dental technology and materials. Composite resin becomes the material of choice as it offers good aesthetics, longevity and allow for minimally intervention approach. There are various ways of composite restorative techniques recommended to make out the best restorative outcome. Direct restorative technique promise acceptable cost, appointment time and color matching but it is a challenge for the clinician especially for extensive cavities. Indirect technique is good for extended cavity and providing less operator error, however, it requires multiple appointments, higher cost and laboratory involvement. Computer-aided design/ computer-aided manufacturing (CAD/CAM) technology might reduce the number of appointments, however, it will cause more financial burden to the patient and the clinician. Therefore, semi-direct technique was introduced, it combines the benefits of direct and indirect technique and this technique can be done without the use of any advanced technology and give out a good treatment outcome.
    Matched MeSH terms: Composite Resins
  10. Naziah Md Jasin, Fatanah Mohamad Suhaimi, Ahmad Fairuz Omar, Husniyati Roslan
    MyJurnal
    Discolouration of microhybrid composite resin is a common problem faced by both dental practitioners and patients. The accumulation of plaque, penetration of colourant particles from foods and beverages, dietary habits and the smoothness of restorations have been known to influence the quality of the aesthetic restoration. The purpose of this study was to determine the effects of polishing systems on surface roughness that led to discolouration of the microhybrid composite resin. Methods: Forty five samples of microhybrid composite resin (Filtex Z100) restorations were polished with two different polishing systems; one-step polishing (OP) system on the distal surface and multiple-step polishing (MP) system on the mesial surface. All samples were then immersed in two common beverages: black coffee and cocoa, for 20 minutes daily throughout 28 days of the experimental period. Results: Data on visual colour measurement and spectrometer colour spectrum was subjected to one-way ANOVA test at a significance level of 0.05. Both solutions were found to cause a significant colour change (p=0.0195) on the microhybrid composite resin. Black coffee solution obtained the highest score (71.6) of visual colour change and the lowest reflectance value (62.818) on the distal surface. Surface roughness evaluation using a scanning electron microscope (SEM) had presented that both polishing systems used produced low level of surface roughness. Conclusion: Although MP system produced a smoother surface compared to OP system, a prolonged exposure to colourant particle found to cause an unacceptable discolouration of microhybrid composite resin.
    Matched MeSH terms: Composite Resins
  11. Baba Musta, Mohamad Md. Tan
    Highly weathered basaltic rock was exposed at PSK profile of Kuantan, Segamat Highway. The weathering profile from fresh rock soil can be observed at PKJ profile at Kg. Jabi Quarry. Twelve rock and soil samples from PSK profile and thirteen samples from PKJ profile have been collected for geochemical analysis. The objective of the analysis is to establish the behaviour of several major and trace elements in the weathering profile of the basaltic rock. The samples were analysed by XRF and XRD techniques. Petrographic study was done on fresh rock samples and concretions. The concentration of major elements (TiO2, Al2O3 and Fe2O3) appear to be increased with the increasing of the degree of weathering whereas the concentration of SiO2 and CaO are decreased. There is a clear correlation between Fe2O3 + Al2O3 with L.O.I as well as between Fe2O3 with Al2O3. Behaviour of the trace elements (Ni, Co, Cr and Zn) against the weathering process are totally different. The secondary minerals (kaolinite, nactire, geothite, hematite and gibbsite) appear to control the behaviour of the major and trace elements.
    Batuan basalt yang terluluhawa sepenuhnya telah dicerap di lokaliti PSK Lebuhraya Segamat-Kuantan. Profil luluhawa yang boleh dilihat perubahan daripada batuan segar hingga tanih didapati di lokaliti PKJ Kuari Kg. Jabi. Dua contoh profil dengan masing-masing 12 sampel dan 13 sample tanih telah dikaji untuk menentukan perlakuan beberapa unsur major dan unsur surih batuan basalt yang terluluhawa. Kaedah analisis yang digunakan ialah pendarflour sinar-X (XRF) dan pembelauan sinar-X (XRF). Kajian petrografi pula dibuat pada sampel batuan segar dan sampel konkresi. Nilai unsur major TiO2, Al2O3 dan Fe2O3 bertambah dengan bertambahnya darjah luluhawa manakala SiO2 dan CaO menyusut. Hubungan korelasi Fe2O3 + Al2O3 dengan L.O.I dan Fe2O3 denagn Al2O3 adalah jelas. Unsur surih nikel (Ni) kobalt (Co), kromium (Cr) dan zink (Zn) mempunyai perlakuan yang berbeza-beza dengan luluhawa. Perlakuan yang ditunjukkan oleh unsur major dan surih tersebut dikawal oleh mineral sekunder (koalinit, nakrit, geotit, hematit dan gibsit).
    Matched MeSH terms: Composite Resins
  12. Umar Hamzah, Abd. Rahim Samsudin
    Identification of a possible source of engineering geological hazard in the limestone area such as cavities, sinkholes and an underground cavern have become necessity for site investigation before any construction of roads, bridges and buildings are carried out. The study is also necessary for tunneling and underground mining works where knowledge of the engineering properties of the rock mass is very important in order to assess the suitability and safety of a proposed building. Geophysical techniques have been widely used in engineering geological study to deal with such problems that normally arise at construction sites with limestone bedrock. In this study, shallow seismic reflection technique and dipole-dipole geoelectrical methods were used to detect the presence of cavity in lime stone area of Batu Cave, Kuala Lumpur. The exact location and depth of cavities in the area were determined from the existing borehole data and report provided by the Geological Survey Department of Malaysia. Based on the borehole data, several cavities that were filled-up with water and fine silt are encountered at depths of 15.7m to 17.8m, 20.2m to 21.1m and 21.4m to 25.7m. Three shallow seismic reflection profiles were established on the cavity area and the results show that the cavities in the limestone occur in the form of 20 to 30m long subterranean channel of 15 to 30 m depth. Dipole-dipole resistivity survey conducted on seismic lines one and three also indicates the presence of the channel and cavities in the limestone.
    Pengecaman punca bencana geologi kejuruteraan di kawasan batu kapur seperti lohong batu kapur, kewujudan lubang benam dan gua-gua batu kapur telah menjadi amat penting dalam penyiasatan tapak sebelum sesuatu pembinaan seperti jalan raya, jambatan dan bangunan dilakukan. Begitu juga dalam kerja-kerja penerowongan dan perlombongan, pengetahuan asas sifat kejuruteraan jasad batuan amat perlu diketahui untuk menitai kesesuaian dan keselamatan bangunan yang bakal dibina. Teknik geofizik telah digunakan secara meluas dalam kajian geologi kejuruteraan untuk menangani masalah yang terdapat di tapak-tapak binaan yang mempunyai batu kapur sebagai batuan dasar. Dalam kajian ini teknik seismos pantulan cetek dan kaedah geoelektrik dwikutub-dwikutub telah digunakan untuk mengesan rongga batu kapur yang terdapat di kawasan Batu Caves, Kuala Lumpur. Kedudukan dan kedalaman rongga batu kapur di kawasan kajian telah ditentukan melalui data lubang gerudi dan laporan yang diperoleh daripada Jabatan Kajibumi Malaysia. Berdasarkan data lubang gerudi tersebut terdapat beberapa rongga yang terisi air dan pasir halus berlodak di kedalaman 15.7 m hingga 17.8 m, 20.2 m hingga 21.1 m dan 21.4 m hingga 25.7 m. Tiga profil seismos pantulan cetek telah dibuat di kawasan berongga tersebut dan hasil survei menunjukkan rongga dalam batu kapur tersebut membentuk palung sepanjang hampir 20 - 30 m pada kedalaman antara 15 m hingga 30 m. Rentisan survei geoelektrik dwikutub yang dilakukan pada profil seismos satu dan tiga juga memperlihatkan kehadiran lohong dan palung dalam batu kapur tersebut.
    Matched MeSH terms: Composite Resins
  13. Umar Hamzah, Ibrahim Komoo
    A survey to characterize seismic and ultrasonic properties of a granite weathering profile have been carried out at a roadcut slope exposure along Kuala Lumpur-Karak highway at kilometres 39.9. The terraced cut slope shows a complete weathering profile beginning from fresh grade I rock to grade VI residual soil. Together with in situ seismic measurement, rock samples have been collected for ultrasonic tests in laboratory. The range of velocities representing grades and indices of weathered rocks and soils are determined from the in situ seismic surveys. The range of ultrasonic velocities and elastic moduli are obtained from the laboratory measurements.
    Satu survei untuk mencirikan sifat seismos dan ultrasonik profil luluhawa granit telah dilakukan di singkapan potongan jalan, cerun utara lebuhraya Kuala Lumpur-Karak pada lokaliti 39.9 km. Potongan berteres ini mempamirkan satu profil luluhawa lengkap iaitu mulai batuan gred 1 yang segar hingga ke tanah baki bergred VI. Di samping pengukuran seismos secara in situ, sampel batuan juga diambil untuk dibuat pengukuran halaju ultrasonik di makmal. Julat halaju yang mewakili gred dan indeks luluhawa bagi tanah dan batuan diperolehi daripada survei seismos in situ. Julat halaju trasonik dan modulus kenyal diperolehi hasil pengukuran di makmal.
    Matched MeSH terms: Composite Resins
  14. Azlisham NAF, Johari Y, Mohamad D, Yhaya MF, Mahmood Z
    Proc Inst Mech Eng H, 2023 Dec;237(12):1339-1347.
    PMID: 38014749 DOI: 10.1177/09544119231208222
    This study evaluated the use of urethane dimethacrylate (UDMA) as a base monomer to prepare the newly developed flowable composite (FC) using nanohybrid silica derived from rice husk in comparison to bisphenol A-glycidyl methacrylate (Bis-GMA) on the degree of conversion and physicomechanical properties. The different loadings of base monomer to diluent monomer were used at the ratio of 40:60, 50:50, and 60:40. The bonding analysis confirmed the presence of nanohybrid silica in the newly developed FC. Independent t-test revealed a statistically significant increase in the degree of conversion, depth of cure and Vickers hardness of the UDMA-based FC, while surface roughness showed comparable results between the two base monomers. In conclusion, UDMA-based FC demonstrated superior performance with 60%-65% conversions, a significantly higher depth of cure exceeding 1 mm which complies with the Internal Standard of Organization 4049 (ISO 4049), and a substantial increase in Vickers hardness numbers compared to Bis-GMA-based FC, making UDMA a suitable alternative to Bis-GMA as a base monomer in the formulation of this newly developed FC derived from rice husk.
    Matched MeSH terms: Composite Resins
  15. Ahmad F, Dent M, Yunus N
    J Prosthodont, 2009 Oct;18(7):596-602.
    PMID: 19515166 DOI: 10.1111/j.1532-849X.2009.00481.x
    This study evaluated the shear bond strengths of light-polymerized urethane dimethacrylate (Eclipse) and heat-polymerized polymethylmethacrylate (Meliodent) denture base polymers to intraoral and laboratory-processed reline materials.
    Matched MeSH terms: Composite Resins/chemistry
  16. Wan Bakar W, McIntyre J
    Aust Dent J, 2008 Sep;53(3):226-34.
    PMID: 18782366 DOI: 10.1111/j.1834-7819.2008.00053.x
    Erosive substances such as gastric acids, lemon juice and even the less erosive cola drinks have been extensively investigated for their destructive effects on enamel. However, their effects on the tooth-coloured restoratives has not been widely analysed. The objective of this study was to assess their effects on the more commonly used glass containing restorative materials in vitro.
    Matched MeSH terms: Composite Resins*
  17. Ayatollahi MR, Yahya MY, Karimzadeh A, Nikkhooyifar M, Ayob A
    PMID: 26046269 DOI: 10.1016/j.msec.2015.05.004
    The aim of this study was to investigate the effects of temperature change and immersion in two common beverages on the mechanical and tribological properties for three different types of dental restorative materials. Thermocycling procedure was performed for simulating temperature changes in oral conditions. Black tea and soft drink were considered for beverages. Universal composite, universal nanohybrid composite and universal nanofilled composite, were used as dental materials. The nanoindentation and nanoscratch experiments were utilized to determine the elastic modulus, hardness, plasticity index and wear resistance of the test specimens. The results showed that thermocycling and immersion in each beverage had different effects on the tested dental materials. The mechanical and tribological properties of nanohybrid composite and nanocomposite were less sensitive to temperature change and to immersion in beverages in comparison with those of the conventional dental composite.
    Matched MeSH terms: Composite Resins/chemistry*
  18. Gupta S, Parolia A, Jain A, Kundabala M, Mohan M, de Moraes Porto IC
    J Indian Soc Pedod Prev Dent, 2015 Jul-Sep;33(3):245-9.
    PMID: 26156281 DOI: 10.4103/0970-4388.160402
    The aim of this in vitro study was an attempt to investigate the effect of different surface treatments on the bond strength between pre-existing composite and repair composite resin.
    Matched MeSH terms: Composite Resins/chemistry*
  19. Lui JL
    Quintessence Int, 1994 May;25(5):313-9.
    PMID: 7938415
    Composite resins have been advocated as a reinforcing build-up material for badly damaged endodontically treated teeth with flared canals. However, the control of an autocuring composite resin is difficult because it polymerizes rapidly within the root canal. While the light-curing composite resins are more user friendly, their polymerization can be a problem deep in the root canal. Light-transmitting plastic posts allow the transmission of light into the root canal and enable intraradicular composite resin reconstitution and reinforcement of weakened roots. At the same time, the light-transmitting plastic post forms an optimal post canal in the rehabilitated root and can accurately fit a matching retentive final post. These light-transmitting posts are a useful addition to the dental armamentarium.
    Matched MeSH terms: Composite Resins*
  20. Sulong MZ, Aziz RA
    J Prosthet Dent, 1990 Mar;63(3):342-9.
    PMID: 2407832
    This is a review of the literature concerning wear related to the following materials used in dentistry: dental amalgam, composite resins, and glass-ionomer cements, as well as natural tooth substance. Discussions are included on both in vivo and in vitro studies in which various methods were used to help determine wear resistance.
    Matched MeSH terms: Composite Resins*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links