Displaying publications 61 - 80 of 100 in total

Abstract:
Sort:
  1. Mohamed Zahidi J, Bee Yong T, Hashim R, Mohd Noor A, Hamzah SH, Ahmad N
    Diagn Microbiol Infect Dis, 2015 Apr;81(4):227-33.
    PMID: 25641125 DOI: 10.1016/j.diagmicrobio.2014.12.012
    Molecular approaches have been investigated to overcome difficulties in identification and differentiation of Brucella spp. using conventional phenotypic methods. In this study, high-resolution melt (HRM) analysis was used for rapid identification and differentiation of members of Brucella genus. A total of 41 Brucella spp. isolates from human brucellosis were subjected to HRM analysis using 4 sets of primers, which identified 40 isolates as Brucella melitensis and 1 as Brucella canis. The technique utilized low DNA concentration and was highly reproducible. The assay is shown to be a useful diagnostic tool, which can rapidly differentiate Brucella up to species level.
    Matched MeSH terms: Specimen Handling/methods
  2. Othman N, Othman NH
    Malays J Pathol, 2012 Dec;34(2):115-21.
    PMID: 23424773 MyJurnal
    The aim of this study was to examine cells (split-sample) that were retained on sampling devices used to collect conventional Pap smears (primary smears) in order to evaluate specimen adequacy and cytological diagnosis of scrapings that are routinely discarded.
    Matched MeSH terms: Specimen Handling/methods*
  3. Katayon S, Noor MJ, Asma M, Ghani LA, Thamer AM, Azni I, et al.
    Bioresour Technol, 2006 Sep;97(13):1455-60.
    PMID: 16213137
    Moringa oleifera is a plant whose seeds have coagulation properties for treating water and wastewater. In this study the coagulation efficiency of Moringa oleifera kept in different storage conditions were studied. The Moringa oleifera seeds were stored at different conditions and durations; open container and closed container at room temperature (28 degrees C) and refrigerator (3 degrees C) for durations of 1, 3 and 5 months. Comparison between turbidity removal efficiency of Moringa oleifera kept in refrigerator and room temperature revealed that there was no significant difference between them. The Moringa oleifera kept in refrigerator and room temperature for one month showed higher turbidity removal efficiency, compared to those kept for 3 and 5 months, at both containers. The coagulation efficiency of Moringa oleifera was found to be dependent on initial turbidity of water samples. Highest turbidity removals were obtained for water with very high initial turbidity. In summary coagulation efficiency of Moringa oleifera was found independent of storage temperature and container, however coagulation efficiency of Moringa oleifera decreased as storage duration increased. In addition, Moringa oleifera can be used as a potential coagulant especially for very high turbidity water.
    Matched MeSH terms: Specimen Handling/methods*
  4. Ewart KM, Lightson AL, Sitam FT, Rovie-Ryan JJ, Mather N, McEwing R
    Forensic Sci Int Genet, 2020 01;44:102187.
    PMID: 31670244 DOI: 10.1016/j.fsigen.2019.102187
    The illegal ivory trade continues to drive elephant poaching. Large ivory seizures in Africa and Asia are still commonplace. Wildlife forensics is recognised as a key enforcement tool to combat this trade. However, the time and resources required to effectively test large ivory seizures is often prohibitive. This limits or delays testing, which may impede investigations and/or prosecutions. Typically, DNA analysis of an ivory seizure involves pairing and sorting the tusks, sampling the tusks, powdering the sample, decalcification, then DNA extraction. Here, we optimize the most time-consuming components of this process: sampling and decalcification. Firstly, using simulations, we demonstrate that tusks do not need to be paired to ensure an adequate number of unique elephants are sampled in a large seizure. Secondly, we determined that directly powdering the ivory using a Dremel drill with a high-speed cutter bit, instead of cutting the ivory with a circular saw and subsequently powdering the sample in liquid nitrogen with a freezer mill, produces comparable results. Finally, we optimized a rapid 2 -h decalcification protocol that produces comparable results to a standard 3-day protocol. We tested/optimised the protocols on 33 raw and worked ivory samples, and demonstrated their utility on a case study, successfully identifying 94% of samples taken from 123 tusks. Using these new rapid protocols, the entire sampling and DNA extraction process takes less than one day and requires less-expensive equipment. We expect that the implementation of these rapid protocols will promote more consistent and timely testing of ivory seizures suitable for enforcement action.
    Matched MeSH terms: Specimen Handling*
  5. Morgan K, Azzani M, Khaing SL, Wong YL, Su TT
    J Low Genit Tract Dis, 2019 Jul;23(3):193-199.
    PMID: 30933030 DOI: 10.1097/LGT.0000000000000476
    OBJECTIVES: Female self-sampling for human papillomavirus (HPV) DNA testing is an alternative screening method that can potentially increase cervical cancer screening coverage. This review addresses the acceptability of HPV DNA testing using self-sampling compared with conventional clinician-collected sampling. Barriers to and others factors associated with acceptability of either method were also examined.

    METHODS: The following electronic resources were searched: Medline @EBSCOHOST(Medline), Embase, PubMed, and CINAHL databases. Manual searches were also conducted. The main outcome of interest was the acceptability of HPV DNA testing by self-sampling in comparison with clinician-collected sampling.

    RESULTS: In total, 23 articles were included in this systematic review. The majority (19 studies) were quantitative intervention studies and 4 studies were qualitative observational studies. Eleven studies reported a preference for self-sampling by women compared with clinician-collected sampling (64.7%-93%). The remaining studies found that women preferred clinician-collected sampling because mainly of respondents' lack of confidence in their ability to complete self-sampling correctly. In most articles reviewed, the studied associated factors, such as demographic factors (age, marital status, and ethnicity), socioeconomic factors (income, education level), reproductive factors (condom use, number of children, current use of contraception, and number of partners), and habits (smoking status) were not found to be significantly associated with preference.

    CONCLUSIONS: Both methods of sampling were found to be acceptable to women. Self-sampling is cost-effective and could increase the screening coverage among underscreened populations. However, more information about the quality, reliability, and accuracy of self-sampling is needed to increase women's confidence about using to this method.

    Matched MeSH terms: Specimen Handling/methods*
  6. Lau SM, Vythilingam I, Doss JI, Sekaran SD, Chua TH, Wan Sulaiman WY, et al.
    Trop Med Int Health, 2015 Oct;20(10):1271-80.
    PMID: 26094839 DOI: 10.1111/tmi.12555
    To determine the effectiveness of using sticky traps and the NS1 dengue antigen kit for the surveillance of Aedes mosquitoes for dengue control.
    Matched MeSH terms: Specimen Handling/methods*
  7. Jamail M, Andrew K, Junaidi D, Krishnan AK, Faizal M, Rahmah N
    Trop Med Int Health, 2005 Jan;10(1):99-104.
    PMID: 15655019
    We conducted a field study of a rapid test (Brugia Rapid) for detection of Brugia malayi infection to validate its sensitivity and specificity under operational conditions. Seven districts in the state of Sarawak, Malaysia, which are endemic for brugian filariasis, were used to determine the test sensitivity. Determination of specificity was performed in another state in Malaysia (Bachok, Kelantan) which is non-endemic for filariasis but endemic for soil-transmitted helminths. In Sarawak both the rapid test and thick blood smear preparation were performed in the field. The rapid test was interpreted on site, whereas blood smears were taken to the district health centres for staining and microscopic examination. Sensitivity of Brugia Rapid dipstick as compared with microscopy of thick blood smears was 87% (20/23; 95% CI: 66.4-97.2) whereas the specificity was 100% (512/512). The lower sensitivity of the test in the field than in laboratory evaluations (> or =95%), was probably due to the small number of microfilaraemic individuals, in addition to difficulties in performing the test in remote villages by field personnel. The overall prevalence of brugian filariasis as determined by the dipstick is 9.4% (95% CI: 8.2-0.5) while that determined by microscopy is 0.90% (95% CI: 0.5-1.3) thus the dipstick detected about 10 times more cases than microscopy. Equal percentages of adults and children were found to be positive by the dipstick whereas microscopy showed that the number of infected children was seven times less than infected adults. The rapid dipstick test was useful as a diagnostic tool for mapping and certification phases of the lymphatic filariasis elimination programme in B. malayi-endemic areas.
    Matched MeSH terms: Specimen Handling/methods
  8. Othman NH, Zaki FH, Hussain NH, Yusoff WZ, Ismail P
    Asian Pac J Cancer Prev, 2016;17(7):3489-94.
    PMID: 27509997
    BACKGROUND: A major problem with cervical cancer screening in countries which have no organized national screening program for cervical cancer is suboptimal participation. Implementation of selfsampling method may increase the coverage.

    OBJECTIVE: We determined the agreement of cytological diagnoses made on samples collected by women themselves (selfsampling) versus samples collected by physicians (Physician sampling).

    MATERIALS AND METHODS: We invited women volunteers to undergo two procedures; cervical selfsampling using the Evalyn brush and physician sampling using a Cervex brush. The women were shown a video presentation on how to take their own cervical samples before the procedure. The samples taken by physicians were taken as per routine testing (Gold Standard). All samples were subjected to Thin Prep monolayer smears. The diagnoses made were according to the Bethesda classification. The results from these two sampling methods were analysed and compared.

    RESULTS: A total of 367 women were recruited into the study, ranging from 22 to 65 years age. There was a significant good agreement of the cytological diagnoses made on the samples from the two sampling methods with the Kappa value of 0.568 (p=0.040). Using the cytological smears taken by physicians as the gold standard, the sensitivity of selfsampling was 71.9% (95% CI:70.972.8), the specificity was 86.6% (95% CI:85.7 87.5), the positive predictive value was 74.2% (95% CI:73.375.1) and the negative predictive value was 85.1% (95% CI: 84.286.0). Selfsampling smears (22.9%) allowed detection of microorganisms better than physicians samples (18.5%).

    CONCLUSIONS: This study shows that samples taken by women themselves (selfsampling) and physicians have good diagnostic agreement. Selfsampling could be the method of choice in countries in which the coverage of women attending clinics for screening for cervical cancer is poor.

    Matched MeSH terms: Specimen Handling/methods*
  9. Othman NH, Mohamad Zaki FH
    Asian Pac J Cancer Prev, 2014;15(20):8563-9.
    PMID: 25374168
    Sub-optimal participation is a major problem with cervical cancer screening in developing countries which have no organized national screening program. There are various notable factors such as 'embarrassment', 'discomfort' and 'no time' cited by women as they are often also the bread winners for the family. Implementation of self-sampling methods may increase their participation. The aim of this article was to provide a survey of various types of self-sampling tools which are commonly used in collection of cervical cells. We reviewed currently available self-sampling devices and collated the advantages and disadvantages of each in terms of its acceptance and its accuracy in giving desired results. In general, regardless of which device is used, self-sampling for cervical scrapings is highly acceptable to women in most of the studies cited.
    Matched MeSH terms: Specimen Handling/methods
  10. Saville M, Hawkes D, Keung M, Ip E, Silvers J, Sultana F, et al.
    J Clin Virol, 2020 06;127:104375.
    PMID: 32361328 DOI: 10.1016/j.jcv.2020.104375
    BACKGROUND: In the last decade, human papillomavirus (HPV) testing has been evaluated extensively for cervical screening, with studies finding increased sensitivity compared to cytology. Another advantage of HPV based-screening is the ability to test vaginal samples that can be collected by women themselves. Self-collection has the potential to extend cervical screening coverage by increasing participation rates, particularly among women who are under-screened or have never screened. This could have a significant impact on cervical cancer prevention, as the majority of invasive cervical cancer cases occur among under-screened women. Both the Netherlands and Australia have transitioned their national programs from cytology to HPV as the primary screening test and both countries include a pathway for self-collection.

    OBJECTIVES: We evaluated the relative sensitivity for HPV detection of self-collection compared with practitioner-collected cervical specimens in the context of the Australian National Cervical Screening Program (NCSP).

    STUDY DESIGN: 303 women aged ≥18 years attending a single tertiary referral centre took their own sample using a flocked-swab, and then had a practitioner-collected sample taken at colposcopy. All samples were tested at a single laboratory on the six PCR-based HPV assays which can be utilised in the NCSP; Roche cobas 4800 and cobas, Abbott RealTime, BD Onclarity, Cepheid Xpert, and Seegene Anyplex.

    RESULTS: HPV16/18 results had high observed agreement between self- and practitioner-collected samples on all assays (range: 0.94-0.99), with good agreement for non-HPV16/18 oncogenic HPV types (range: 0.64-0.73).

    CONCLUSIONS: Self-collection for HPV-based cervical screening shows good concordance and relative sensitivity when compared to practitionercollected samples across assays in the NCSP.

    Matched MeSH terms: Specimen Handling/methods*
  11. Chua AL, Elina HT, Lim BH, Yean CY, Ravichandran M, Lalitha P
    J Med Microbiol, 2011 Apr;60(Pt 4):481-485.
    PMID: 21183596 DOI: 10.1099/jmm.0.027433-0
    Vibrio cholerae has caused severe outbreaks of cholera worldwide with thousands of recorded deaths annually. Molecular diagnosis for cholera has become increasingly important for rapid detection of cholera as the conventional methods are time-consuming and labour intensive. However, traditional PCR tests still require cold-chain transportation and storage as well as trained personnel to perform, which makes them user-unfriendly. The aim of this study was to develop a thermostabilized triplex PCR test for cholera which is in a ready-to-use form and requires no cold chain. The PCR test specifically detects both toxigenic and non-toxigenic strains of V. cholerae based on the cholera toxin A (ctxA) and outer-membrane lipoprotein (lolB) genes. The thermostabilized triplex PCR also incorporates an internal amplification control that helps to check for PCR inhibitors in samples. PCR reagents and the specific primers were lyophilized into a pellet form in the presence of trehalose, which acts as an enzyme stabilizer. The triplex PCR was validated with 174 bacteria-spiked stool specimens and was found to be 100 % sensitive and specific. The stability of the thermostabilized PCR was evaluated using the Q10 method and it was found to be stable for approximately 7 months at 24 °C. The limit of detection of the thermostabilized triplex PCR assay was 2×10(4) c.f.u. at the bacterial cell level and 100 pg DNA at the genomic DNA level, comparable to conventional PCR methods. In conclusion, a rapid thermostabilized triplex PCR assay was developed for detecting toxigenic and non-toxigenic V. cholerae which requires minimal pipetting steps and is cold chain-free.
    Matched MeSH terms: Specimen Handling/methods
  12. Tan CS, Hamzah ND, Ismail ZHF, Jerip AR, Kipli M
    Med J Malaysia, 2021 05;76(3):298-303.
    PMID: 34031326
    INTRODUCTION: Cervical cancer is the third most common cancer among Malaysian women. Sarawak, the largest state in Malaysia has consistently recorded the highest cervical cancer rate in the country where nearly half of its population still live in the rural areas and is at increased risk of the disease due to inequitable access to healthcare. The countrywide lockdown due to the COVID-19 pandemic had halted the accessibility to cervical cancer screening programme. The aim of the study is to determine the feasibility of providing primary HPV DNA test using the selfsampling method to the hard-to-reach population in the interior of Sarawak during the COVID-19 pandemic.

    MATERIALS AND METHODS: This is a cross-sectional study where women aged between 20-80 years were recruited via convenient sampling from villages in Long Banga, Sarawak over a five-day outreach programme. Cervicovaginal selfsamples were obtained and screened for the presence of high-risk human papillomavirus DNA (HR-HPV) using the careHPVTM Test. A self-administered questionnaire was also administered to determine the sociodemographic and perception towards the self-sampling method.

    RESULTS: The 55 women recruited consist of ethnic backgrounds of Penan (58.18%), Kenyah (25.45%), Iban (5.45%), Saban (3.64%), Kelabit (3.64%), Malay (1.82%) and Chinese (1.82%). The prevalence of HR-HPV was 1.85% (n=1/55). Nearly 80% of the women were unemployed, and more than half have had attended primary education. Nine (16.4%) have heard about HPV, and seven (13%) knew HPV infection could cause cervical cancer. Three of them had HPV vaccination, and only one (1.85%) knew the brand of the HPV vaccine. Although 40% preferred self-sampling over clinician-collection, only ten (18.2%) women have completed the self-collection perception questionnaire.

    CONCLUSION: Primary HPV DNA screening using the selfsampling method can be carried out in the remote areas during the COVID-19 pandemic without compromising mobility restriction.

    Matched MeSH terms: Specimen Handling/methods*
  13. Abdullah NN, Daud S, Wang SM, Mahmud Z, Mohd Kornain NK, Al-Kubaisy W
    J Obstet Gynaecol, 2018 Apr;38(3):402-407.
    PMID: 29385850 DOI: 10.1080/01443615.2017.1379061
    This study aims to determine the acceptability of Human Papilloma Virus (HPV) self-sampling and the factors associated with willingness to buy HPV self-sampling kit in the future. A total of 164 women aged 28-60 years old from Obstetrics & Gynaecology clinics at a teaching hospital performed HPV self-sampling using the Digene HC2 DNA collection kit. After samples were taken, the participants were given self-administered questionnaires. The majority of the participants were Malay (93.9%), had attained tertiary education (65.2%) and were employed (70.1%). The acceptability was good. More than half of the participants felt that self-sampling was easy. Only 1.2% felt that the procedure was difficult to perform. Most reported no pain at all during the procedure (66.9%). The commonest concern was getting a good sample (90.1%). A number of Pap smears were found to be significantly associated with the willingness to buy the HPV self-sampling kit. HPV self-sampling has the potential to be included in the cervical cancer screening programme. Impact Statement What is already known on this subject: HPV self-sampling is acceptable in some developed and developing countries. It is acceptable because it was easy to perform with very minimal pain or discomfort. Studies on the acceptance of self-screening are needed to plan a policy on self-sampling in the future. What the results of this study add: Our study adds new findings to the body of knowledge on self-sampling in the local population. We found that more women are willing to do the self-sampling at the clinic rather than at home. Although more than 90% expressed willingness to do self-sampling in the future, only 70% of them were willing to purchase the kit. Cost is a potential barrier to women who have the interest to perform the self-sampling. Given the global economic challenges, cost is inevitably an important predictor that we have to consider. What the implications are of these findings for clinical practice and/or further research: Future research should examine women from the rural areas and those who are resilient to Pap smear screening. In clinical practice, clinicians should acknowledge that cost is a potential barrier for women who are willing to do self-sampling. Self-sampling could be an option for women with no financial constraint to buy the kit. However, clinicians should counsel women so that they can make an informed choice in determining their screening method.
    Matched MeSH terms: Specimen Handling/methods*
  14. Ooi MH, Solomon T, Podin Y, Mohan A, Akin W, Yusuf MA, et al.
    J Clin Microbiol, 2007 Jun;45(6):1858-66.
    PMID: 17446325
    Human enterovirus 71 and coxsackievirus A16 are important causes of hand-foot-and-mouth disease (HFMD). Like other enteroviruses, they can be isolated from a range of sterile and nonsterile sites, but which clinical sample, or combination of samples, is the most useful for laboratory diagnosis of HFMD is not clear. We attempted virus culture for 2,916 samples from 628 of 725 children with HFMD studied over a 3 1/2-year period, which included two large outbreaks. Overall, throat swabs were the single most useful specimen, being positive for any enterovirus for 288 (49%) of 592 patients with a full set of samples. Vesicle swabs were positive for 169 (48%) of 333 patients with vesicles, the yield being greater if two or more vesicles were swabbed. The combination of throat plus vesicle swabs enabled the identification of virus for 224 (67%) of the 333 patients with vesicles; for this patient group, just 27 (8%) extra patients were diagnosed when rectal and ulcer swabs were added. Of 259 patients without vesicles, use of the combination of throat plus rectal swab identified virus for 138 (53%). For 60 patients, virus was isolated from both vesicle and rectal swabs, but for 12 (20%) of these, the isolates differed. Such discordance occurred for just 11 (10%) of 112 patients with virus isolated from vesicle and throat swabs. During large HFMD outbreaks, we suggest collecting swabs from the throat plus one other site: vesicles, if these are present (at least two should be swabbed), or the rectum if there are no vesicles. Vesicle swabs give a high diagnostic yield, with the added advantage of being from a sterile site.
    Matched MeSH terms: Specimen Handling/methods
  15. Mohammed Saghir SA, Al-Hassan FM, Alsalahi OS, Abdul Manaf FS, Baqir HS
    J Coll Physicians Surg Pak, 2012 May;22(5):294-7.
    PMID: 22538033 DOI: 05.2012/JCPSP.294297
    To determine the optimum storage temperature and time for prothrombin time and activated partial thromboplastin time at various intervals at both room temperature and refrigerator.
    Matched MeSH terms: Specimen Handling
  16. Madulid DA
    J Ethnopharmacol, 1996 Apr;51(1-3):205-8.
    PMID: 9213618
    In October, 1993, 16 months after the United Nations approved the International Convention on Biodiversity held in Rio de Janeiro, June, 1992, the Philippine Congress ratified and adopted the Convention. This is a manifestation of the full support of the Philippines for the principles and policies adopted by the UN body on the conservation of biodiversity, sustainable development of biological resources and equitable sharing of benefits between users and owners of biodiversity resources. The Philippine scientific community has long recognized the need for and importance of a national guideline and policy with regard to the collection of plants and animals in the Philippines for scientific or commercial purposes. A series of consultative meetings were held by representatives of government agencies, non-government organizations, private organizations, academic and private persons concerned with biodiversity conservation to formulate national guidelines that regulate the collection of plant and animal specimens in the country. Guidelines were unanimously adopted by various government agencies and academia and a Memorandum of Agreement (MOA) was signed on September 28, 1990. Very recently a new document was drafted, specifically to serve as a guideline for those who desire to undertake sample collecting in the Philippines for biodiversity prospecting. The document is now being reviewed by government departments and agencies and will be presented to the President of the Philippines for signing as an Executive Order (EO). Once signed, this EO will serve as a national policy for bioprospecting in the country. The Philippines is one of the countries in Southeast Asia that has endorsed the adoption of regional guidelines on the collection of plant and animal organisms for drug development. The ASEAN Agreement on the Conservation of Nature and Natural Resources (1985). The Manila Declaration (1992) and lately, the Melaka Accord (1994), all of which were signed by various countries in Asia, are manifestations of this interest.
    Matched MeSH terms: Specimen Handling
  17. Lim Swee Eng, Bin Mohamed Hussain AH
    Med J Malaysia, 1973 Dec;28(2):103-8.
    PMID: 4276266
    Matched MeSH terms: Specimen Handling
  18. Sarirah M, Wijayanti MA, Murhandarwati EEH
    Trop Biomed, 2019 Sep 01;36(3):677-686.
    PMID: 33597489
    In Soil-Transmitted Helminth (STH) control programs, microscopic examination is applied as a standard method for detecting the presence and the number of STH eggs. The time limitations of fresh specimen processing, especially for an accurate quantitative diagnosis, cause the specimen processing to be delayed or should be performed at a referral laboratory. This deferment requires preservatives to keep the stool integrity without reducing the accuracy. The aims of this study were: 1) to compare the proportion of positive samples and the intensity of A. lumbricoides, T. trichiura, and hookworm infection based on the examination of fresh samples and stool preserved by 10% formalin for >12 months and 2) to determine the most reliably accurate between Kato-Katz and mini-FLOTAC methods in detecting A. lumbricoides, T. trichiura, and hookworm eggs in preserved stools both qualitatively and quantitatively. Seventy-eight (78) stool samples were examined by mini-FLOTAC, and KatoKatz methods. Proportion of positive samples of A. lumbricoides, T. trichiura, and hookworms in fresh and in >=12 months 10% formalin preserved stools had no significant difference. Helminths density (eggs per gram of stool/EPG) in fresh samples was fewer compared to EPG in preserved samples (p <0.05) which leads to a lower proportion of moderate and high level groups in fresh stools samples compared to those in preserved samples (p <0.05). In preserved samples, as qualitative method, mini-FLOTAC detected more A. lumbricoides and T. trichiura eggs than Kato-Katz, while hookworm eggs were detected more by Kato-Katz than the miniFLOTAC. As a quantitative detection, Kato-Katz showed higher calculation of STH EPG than mini-FLOTAC. Using 10% formalin preservation for stool samples, the STH eggs' morphology could still be well identified. Homogenization process and low number of samples tested, were acknowledged as the limitation of this study.
    Matched MeSH terms: Specimen Handling
  19. Kong PL, Looi LM, Lau TP, Cheah PL
    PLoS One, 2016;11(9):e0161720.
    PMID: 27598341 DOI: 10.1371/journal.pone.0161720
    Telomeres shorten with physiological aging but undergo substantial restoration during cancer immortalization. Increasingly, cancer studies utilize the archive of formalin-fixed, paraffin-embedded (FFPE) tissues in diagnostic pathology departments. Conceptually, such studies would be confounded by physiological telomere attrition and loss of DNA integrity from prolonged tissue storage. Our study aimed to investigate these two confounding factors. 145 FFPE tissues of surgically-resected, non-diseased appendixes were retrieved from our pathology archive, from years 2008 to 2014. Cases from 2013 to 2014 were categorized by patient chronological age (0-20 years, 21-40 years, 41-60 years, > 60 years). Telomere lengths of age categories were depicted by telomere/chromosome 2 centromere intensity ratio (TCR) revealed by quantitative fluorescence in situ hybridization. Material from individuals aged 0-20 years from years 2013/2014, 2011/2012, 2009/2010, and 2008 were compared for storage effect. Telomere integrity was assessed by telomere fluorescence intensity (TFI). Epithelial TCRs (mean ± SD) for the respective age groups were 4.84 ± 2.08, 3.64 ± 1.21, 2.03 ± 0.37, and 1.93 ± 0.45, whereas corresponding stromal TCRs were 5.16 ± 2.55, 3.84 ± 1.36, 2.49 ± 1.20, and 2.93 ± 1.24. A trend of inverse correlation with age in both epithelial and stromal tissues is supported by r = -0.69, p < 0.001 and r = -0.42, p < 0.001 respectively. Epithelial TFIs (mean ± SD) of years 2013/2014, 2011/2012, 2009/2010 and 2008 were 852.60 ± 432.46, 353.04 ± 127.12, 209.24 ± 55.57 and 429.22 ± 188.75 respectively. Generally, TFIs reduced with storage duration (r = -0.42, p < 0.001). Our findings agree that age-related telomere attrition occurs in normal somatic tissues, and suggest that an age-based reference can be established for telomere studies on FFPE tissues. We also showed that FFPE tissues archived beyond 2 years are suboptimal for telomere analysis.
    Matched MeSH terms: Specimen Handling
  20. Abd Rahman AN, Tett SE, Staatz CE
    Clin Pharmacokinet, 2014 Mar;53(3):227-245.
    PMID: 24327238 DOI: 10.1007/s40262-013-0124-z
    Mycophenolic acid (MPA) is a potent immunosuppressant agent, which is increasingly being used in the treatment of patients with various autoimmune diseases. Dosing to achieve a specific target MPA area under the concentration-time curve from 0 to 12 h post-dose (AUC12) is likely to lead to better treatment outcomes in patients with autoimmune disease than a standard fixed-dose strategy. This review summarizes the available published data around concentration monitoring strategies for MPA in patients with autoimmune disease and examines the accuracy and precision of methods reported to date using limited concentration-time points to estimate MPA AUC12. A total of 13 studies were identified that assessed the correlation between single time points and MPA AUC12 and/or examined the predictive performance of limited sampling strategies in estimating MPA AUC12. The majority of studies investigated mycophenolate mofetil (MMF) rather than the enteric-coated mycophenolate sodium (EC-MPS) formulation of MPA. Correlations between MPA trough concentrations and MPA AUC12 estimated by full concentration-time profiling ranged from 0.13 to 0.94 across ten studies, with the highest associations (r (2) = 0.90-0.94) observed in lupus nephritis patients. Correlations were generally higher in autoimmune disease patients compared with renal allograft recipients and higher after MMF compared with EC-MPS intake. Four studies investigated use of a limited sampling strategy to predict MPA AUC12 determined by full concentration-time profiling. Three studies used a limited sampling strategy consisting of a maximum combination of three sampling time points with the latest sample drawn 3-6 h after MMF intake, whereas the remaining study tested all combinations of sampling times. MPA AUC12 was best predicted when three samples were taken at pre-dose and at 1 and 3 h post-dose with a mean bias and imprecision of 0.8 and 22.6 % for multiple linear regression analysis and of -5.5 and 23.0 % for maximum a posteriori (MAP) Bayesian analysis. Although mean bias was less when data were analysed using multiple linear regression, MAP Bayesian analysis is preferable because of its flexibility with respect to sample timing. Estimation of MPA AUC12 following EC-MPS administration using a limited sampling strategy with samples drawn within 3 h post-dose resulted in biased and imprecise results, likely due to a longer time to reach a peak MPA concentration (t max) with this formulation and more variable pharmacokinetic profiles. Inclusion of later sampling time points that capture enterohepatic recirculation and t max improved the predictive performance of strategies to predict EC-MPS exposure. Given the considerable pharmacokinetic variability associated with mycophenolate therapy, limited sampling strategies may potentially help in individualizing patient dosing. However, a compromise needs to be made between the predictive performance of the strategy and its clinical feasibility. An opportunity exists to combine research efforts globally to create an open-source database for MPA (AUC, concentrations and outcomes) that can be used and prospectively evaluated for AUC target-controlled dosing of MPA in autoimmune diseases.
    Matched MeSH terms: Specimen Handling
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links