Displaying publications 81 - 100 of 104 in total

Abstract:
Sort:
  1. Low A, Bansal V
    Biomed Imaging Interv J, 2010 01 01;6(1):e9.
    PMID: 21611068 DOI: 10.2349/biij.6.1.e9
    Many papers have been written on the synthesis of gold nanoparticles but very few included pictures of the process, and none of them used video to show the whole process of synthesis. This paper records the process of synthesis of gold nanoparticles using video clips. Every process from cleaning of glassware, an important step in the synthesis of metallic nanoparticles, to the dialysis process is shown. It also includes the preparation of aqua regia and the actual synthesis of gold nanoparticles. In some papers, the dialysis process was omitted, but in this paper, it is included to complete the whole process as it is being used for purification.
  2. Mahmood S, Sabih Z, Sabih D
    Biomed Imaging Interv J, 2011 Apr;7(2):e10.
    PMID: 22287984 DOI: 10.2349/biij.7.2.e10
    Breast lymphoma is an uncommon neoplasm affecting the breast and is extremely rare in males. While gynaecomastia is common and in most cases benign, it can sometimes result from significant pathology and the physician should keep in mind the possible diseases that can lead to gynaecomastia. This paper reports a case of lymphoma presenting as unilateral gynaecomastia. The paper discusses the differential diagnosis and emphasises the points that should raise the suspicion of pathology.Mammography, high resolution ultrasound and biopsy findings are discussed and literature survey is presented.
  3. Chan M, Yang J, Song Y, Burman C, Chan P, Li S
    Biomed Imaging Interv J, 2011 Apr;7(2):e11.
    PMID: 22287985 DOI: 10.2349/biij.7.2.e11
    PURPOSE: The imaging characteristics of two popular kV cone-beam CT (CBCT) and two MVCT systems utilised in image-guided radiation therapy (IGRT) were evaluated.

    MATERIALS AND METHODS: The study was performed on Varian Clinac iX, Elekta Synergy S, Siemens Oncor, and Tomotherapy. A CT phantom (Catphan-504, Phantom Laboratory, Salem, NY) was scanned for measurements of image quality including image noise, uniformity, density accuracy, spatial resolution, contrast linearity, and contrast resolution. The measurement results were analysed using in-house image analysis software. Reproducibility, position correction, and geometric accuracy were also evaluated with markers in a smaller alignment phantom. The performance evaluation compared volumetric image properties from these four systems with those from a conventional diagnostic CT (CCT).

    RESULTS: It was shown that the linearity of the two kV CBCT was fairly consistent with CCT. The Elekta CBCT with half-circle 27-cm FOV had higher CT numbers than the other three systems. The image noises of the Elekta kV CBCT, Siemens MV CBCT, and Tomotherapy fan-beam CT (FBCT) are about 2-4 times higher than that of the Varian CBCT. The spatial resolutions of two kV CBCTs and two MV CBCTs were 8-11 lp/cm and 3-5 lp/cm, respectively.

    CONCLUSION: Elekta CBCT provided a faster image reconstruction and low dose per scan for half-circle scanning. Varian CBCT had relatively lower image noise. Tomotherapy FBCT had the best uniformity.

  4. Chiu-Tsao ST, Chan M
    Biomed Imaging Interv J, 2009 Oct;5(4):e16.
    PMID: 21610987 DOI: 10.2349/biij.5.4.e16
    The authors have studied the feasibility of using three new high-sensitivity radiochromic devices in measuring the doses to peripheral points outside the primary megavoltage photon beams. The three devices were GAFCHROMIC® EBT film, prototype Low Dose (LD) Film, and prototype LD Card. The authors performed point dosimetry using these three devices in water-equivalent solid phantoms at x = 3,5,8,10, and 15 cm from the edge of 6 MV and 15 MV photon beams of 10x10 cm(2), and at depths of 0, 0.5 cm, and depth of maximum dose. A full sheet of EBT film was exposed with 5000 MU. The prototype LD film pieces were 1.5x2 cm(2) in size. Some LD films were provided in the form of a card in 1.8x5 cm(2) holding an active film in 1.8x2 cm(2). These are referred to as "LD dosimeter cards". The small LD films and cards were exposed with 500 MU. For each scanned film, a 6 mm circular area centered at the measurement point was sampled and the mean pixel value was obtained. The calibration curves were established from the calibration data for each combination of film/cards and densitometer/scanner. The doses at the peripheral points determined from the films were compared with those obtained using ion chamber at respective locations in a water phantom and general agreements were found. It is feasible to accurately measure peripheral doses of megavoltage photon beams using the new high-sensitivity radiochromic devices. This near real-time and inexpensive method can be applied in a clinical setting for dose measurements to critical organs and sensitive patient implant devices.
  5. Muttarak M, Sriburi T
    Biomed Imaging Interv J, 2012 Jan;8(1):e7.
    PMID: 22970063 DOI: 10.2349/biij.8.1.e7
    OBJECTIVE: To document the types of congenital renal anomalies detected in adulthood, the clinical presentation and complications of these renal anomalies, and the most useful imaging modality in detecting a renal anomaly.

    MATERIALS AND METHODS: This study was approved by the institutional review board and informed consent was waived. Between January 2007 and January 2011, the clinical data and imaging studies of 28 patients older than 18 years diagnosed with renal anomaly at the authors' institution were retrospectively reviewed. Renal anomalies in this study included only those with abnormality in position and in form.

    RESULTS: Of these 28 patients, 22 underwent imaging studies and their results constituted the material of this study. Of the 22 patients, 14 had horseshoe kidneys (HSK), four had crossed renal ectopia and four had malrotation. Sixteen patients were men and six were women. The patients ranged in age from 19 to 74 years (mean age 51.1 years). Clinical presentations were abdominal pain (13), fever (13), haematuria (4), palpable mass (2), asymptomatic (2), polyuria (1) dysuria (1), blurred vision (1), and headache with weakness of left extremities (1). Imaging studies included abdominal radiograph (15), intravenous pyelography (IVP) (8), retrograde pyelography (RP) (4), ultrasonography (US) (7), and computed tomography (CT) (9). Associated complications included urinary tract stones (17), urinary tract infection (16), hydronephrosis (12), and tumours (2). Abdominal radiograph suggested renal anomalies in nine out of 15 studies. IVP, RP, US and CT suggested anomalies in all patients who had these studies performed. However, CT was the best imaging modality to evaluate anatomy, function and complications of patients with renal anomalies.

    CONCLUSION: HSK was the most common renal anomaly, with abdominal pain and fever being the most common presentations. UTI and stones were the most common complications. IVP, RP, US and CT can be used to diagnose renal anomalies but CT is the best imaging modality to evaluate renal anatomy, function and its complications.

  6. Sim L
    Biomed Imaging Interv J, 2008 Oct;4(4):e32.
    PMID: 21611017 DOI: 10.2349/biij.4.4.e32
    There are a number of models for the acquisition of digital image management systems. The specific details for development of a budget for a PACS/RIS acquisition will depend upon the acquisition model - although there are similarities in the overarching principles and general information, particularly concerning the radiology service requirements that will drive budget considerations.While budgeting for PACS/RIS should follow the same principles as budgeting for any new technology, it is important to understand how far the implementation of digital image management systems can reach in a healthcare setting. Accurate identification of those elements of the healthcare service that will be affected by a PACS/RIS implementation is a critical component of successful budget formation and of the success of any business case and subsequent project that relies on those budget estimates.A budget for a PACS/RIS capital acquisition project should contain capital and recurrent elements. The capital is associated with the acquisition of the system in a purchase model and capital budget may also be required for upgrade - depending upon a facility's financial management processes.The recurrent (or operational) cost component for the PACS/RIS is associated with maintaining the system(s) in a sustainable operational state.It is also important to consider the service efficiencies, cost savings and service quality improvements that PACS/RIS can generate and include these factors into the economic analysis of any proposal for a PACS/RIS project.
  7. Hampson F, Sinclair M, Smith S
    Biomed Imaging Interv J, 2011 01 01;7(1):e8.
    PMID: 21655117 DOI: 10.2349/biij.7.1.e8
    The role of surgery in the morbidly obese is becoming more prominent. There are a variety of surgical approaches which can be used and radiology plays a crucial role in post operative follow up, particularly in the management of complications. Many general radiologists remain unfamiliar with both the normal and abnormal appearances after bariatric surgery and this pictorial review aims to bridge this gap.
  8. Seet K, Barghi A, Yartsev S, Van Dyk J
    Biomed Imaging Interv J, 2010 07 01;6(3):e31.
    PMID: 21611047 DOI: 10.2349/biij.6.3.e31
    PURPOSE: To find the optimal slice thickness (Δτ) setting for patient registration with kilovoltage cone-beam CT (kVCBCT) on the Varian On Board Imager (OBI) system by investigating the relationship of slice thickness to automatic registration accuracy and contrast-to-noise ratio.

    MATERIALS AND METHOD: Automatic registration was performed on kVCBCT studies of the head and pelvis of a RANDO anthropomorphic phantom. Images were reconstructed with 1.0 ≤ Δτ (mm) ≤ 5.0 at 1.0 mm increments. The phantoms were offset by a known amount, and the suggested shifts were compared to the known shifts by calculating the residual error. A uniform cylindrical phantom with cylindrical inserts of various known CT numbers was scanned with kVCBCT at 1.0 ≤ Δτ (mm) ≤ 5.0 at increments of 0.5 mm. The contrast-to-noise ratios for the inserts were measured at each Δτ.

    RESULTS: For the planning CT slice thickness used in this study, there was no significant difference in residual error below a threshold equal to the planning CT slice thickness. For Δτ > 3.0 mm, residual error increased for both the head and pelvis phantom studies. The contrast-to-noise ratio is proportional to slice thickness until Δτ = 2.5 mm. Beyond this point, the contrast-to-noise ratio was not affected by Δτ.

    CONCLUSION: Automatic registration accuracy is greatest when 1.0 ≤ Δτ (mm) ≤ 3.0 is used. Contrast-to-noise ratio is optimal for the 2.5 ≤ Δτ (mm) ≤ 5.0 range. Therefore 2.5 ≤ Δτ (mm) ≤ 3.0 is recommended for kVCBCT patient registration where the planning CT is 3.0 mm.

  9. Mandarano G, Sim J
    Biomed Imaging Interv J, 2008 Oct;4(4):e28.
    PMID: 21611015 DOI: 10.2349/biij.4.4.e28
    The magnetic resonance cholangiopancreatography (MRCP) examination has all but replaced the diagnostic endoscopic retrograde cholangiopancreatography (ERCP) examination for imaging the biliary tree and pancreatic ducts in many practical aspects of the clinical setting. Despite this increase in popularity, many magnetic resonance imaging (MRI) radiographers still find aspects of the MRCP examination quite challenging. The aim of this tutorial paper is to provide useful technical advice on how to overcome such perceived challenges and thus produce a successful diagnostic MRCP examination. This paper will be of interest to novice MRI radiographers who are at the beginning of their learning curve in MRCP examination. Other MRI radiographers who are interested in practical tips for protocol variations may also find the paper useful.
  10. Kachewar S, Kulkarni D
    Biomed Imaging Interv J, 2011 Oct;7(4):e27.
    PMID: 22279504 DOI: 10.2349/biij.7.4.e27
    This short case report discusses the various aspects of penile fracture, which is a rare entity. Nevertheless, the incidence of penile fractures is on the rise due to the increased use of performance-enhancing drugs. An individual with a penile fracture should seek immediate medical referral. Prompt diagnosis and management is necessary to prevent undesirable after-effects as discussed. Emphasis is made on how imaging with ultrasound enables a quick and complete assessment of this mishap.
  11. Majid Y, Warade M, Sinha J, Kalyanpur A, Gupta T
    Biomed Imaging Interv J, 2011 01 01;7(1):e2.
    PMID: 21655111 DOI: 10.2349/biij.7.1.e2
    Noninvasive imaging of coronary artery disease is rapidly replacing angiography as the first line of investigation. Multislice CT is the non-invasive modality of choice for imaging coronary artery disease and provides high speed with good spatial resolution. CT coronary angiography in addition to detecting and characterising atherosclerotic coronary artery disease is also a good imaging tool for evaluating anomalies of coronary arteries. Superdominant right coronary artery with absent left circumflex artery is one such rare coronary artery anomaly which is well evaluated with multislice CT angiography. The authors report one such case of superdominant right coronary artery with absent left circumflex artery imaged with 64-slice MDCT.
  12. Wong M, Shum S, Chau W, Cheng C
    Biomed Imaging Interv J, 2010 10 01;6(4):e39.
    PMID: 21611075 DOI: 10.2349/biij.6.4.e39
    Assessment of the stomach is not commonly included in routine scanning protocol of upper abdominal ultrasound (USG). However, assessment of the stomach in patients presenting with epigastric pain can yield invaluable results. This paper presents, as an illustration, a case of carcinoma of stomach detected by transabdominal ultrasound. The diagnosis is confirmed by subsequent CT, upper endoscopy and operation.
  13. Smith K
    Biomed Imaging Interv J, 2012 Jan;8(1):e2.
    PMID: 22970058 DOI: 10.2349/biij.8.1.e2
    A 69 year-old man presented with an incidental finding on radiograph of a lesion in the left upper lobe. CT indicated it was likely to be a neoplasm and CT-guided FNA was requested. The lesion was located medial to the scapula so a creative approach was utilised to gain access to the lesion. This study discusses the approach used and why it reduced patient risk compared to a more conventional procedure. The sample was positive for neoplasm and there were no complications arising from the procedure.
  14. Sabih D, Ahmad E, Sabih A, Sabih Q
    Biomed Imaging Interv J, 2010 10 01;6(4):e38.
    PMID: 21611074 DOI: 10.2349/biij.6.4.e38
    The authors report a case of a cephalopagus conjoined twin that was diagnosed at 29 weeks of gestation despite the mother having had two ultrasounds done previously. The fetus had one head and face, fused thoraces, common umbilicus but had two pelvises and two sets of genitalia. The fetus had four normally formed legs and arms.Antenatal ultrasound images are supplemented by post natal photographs. A review of literature, clues to ultrasound diagnosis and possible causes of missing this significant abnormality until the 3rd trimester are discussed.
  15. Chitapanarux I, Tharavichitkul E, Lorvidhaya V, Sittitrai P, Pattarasakulchai T
    Biomed Imaging Interv J, 2010 07 01;6(3):e23.
    PMID: 21611042 DOI: 10.2349/biij.6.3.e23
    OBJECTIVE: Induction chemotherapy (IC) and concurrent chemoradiotherapy (CCRT) for locally advanced head and neck cancer has been studied in many clinical trials. This study was conducted to determine the response rate of IC with paclitaxel, ifosfamide, and cisplatin followed by CCRT with cisplatin for this group of patients, and the effect of the entire treatment on survival and time to disease progression.

    METHODS: Thirty patients with advanced and unresectable head and neck cancer were treated with 2 cycles of induction paclitaxel/ ifosfamide/ cisplatin. If the primary tumor had a complete or partial response, patients were treated with 2 more cycles of IC followed by radiotherapy 70 Gy plus 3 cycles of cisplatin. For those with less than partial response or disease progression were treated according to the discretion of the physicians.

    RESULTS: Ninety percent of patients had stage IV disease and 40% of them had primary tumor at maxillary sinus and nasal cavity. One patient (3%) achieved complete response (CR) and 18 patients had partial responses (PR) to IC. CCRT enhanced the response rate, resulting in a total of 3 CR (10%) and 16 PR (53%) to treatment. The median time to progression was 11.5 months. The median overall survival was 27 months. The most severe hematologic toxicity occurred during IC was grade3-4 neutropenia (40%). Grade 3-4 mucositis occurred in 68% of patients during CCRT.

    CONCLUSION: This novel combined-modality treatment program, is toxic but feasible, and can be administered for selected patients with advanced and unresectable head and neck cancer. © 2010 Biomedical Imaging and Intervention Journal. All rights reserved.

  16. Zaher S, Lyons D, Regan L
    Biomed Imaging Interv J, 2010 04 01;6(2):e28.
    PMID: 21611041 DOI: 10.2349/biij.6.2.e28
    A 35 year-old para 1+0 underwent MRgFUS per study protocol for multiple uterine fibroids, the largest of which measured 5 cm. She conceived 10 months following the procedure. The patient was induced at 41+6 weeks and underwent a normal vaginal delivery.
  17. Lam S, Bux S, Kumar G, Ng Kh, Hussain A
    Biomed Imaging Interv J, 2009 Jul;5(3):e13.
    PMID: 21611051 MyJurnal DOI: 10.2349/biij.5.3.e13
    To compare the image quality of the low-dose to the standard-dose protocol of MDCT scanning of the paranasal sinuses, based on subjective assessment and determine the radiation doses to the eyes and thyroid gland and dose reduction between these two protocols.
  18. Ho E
    Biomed Imaging Interv J, 2012 Jan;8(1):e9.
    PMID: 22970065 DOI: 10.2349/biij.8.1.e9
    Radiology is a relatively high-cost and high-maintenance aspect of medicine. Expertise is constantly required, from acquisition to its use and quality assurance programmes. However, it is an integral part of healthcare practice, from disease diagnosis, surveillance and prevention to treatment monitoring. It is alarming that two thirds of the world is deficient in or lacks even basic diagnostic imaging. Developing and underdeveloped countries need help in improving medical imaging. Help is coming from various organisations, which are extending hands-on teaching and imparting knowledge, as well as training trainers to increase the pool of skilled practitioners in the use of imaging equipment and other aspects of radiology services. The scene for social radiology is changing and set to positively impact the world in the (near) future.
  19. Vijayananthan A, Tan L, Owen A, Bhat R, Edwards R, Robertson I, et al.
    Biomed Imaging Interv J, 2006 Oct;2(4):e55.
    PMID: 21614335 MyJurnal DOI: 10.2349/biij.2.4.e55
    There is a growing concern about the transmission of bloodborne pathogens during medical procedures among health care workers and patients. Over the last three decades, radiological services have undergone many changes with the introduction of new modalities. One of these new disciplines is interventional radiology (IR) which deals with procedures such as arteriography, image-guided biopsies, intravascular catheter insertions, angioplasty and stent placements. Despite these developments, the potential for accidental blood exposure and exposure to other infectious material continues to exist. Therefore, it is important for all radiologists who perform invasive procedures to observe specific recommendations for infection control. In this review, we look at the different policies for protection and universal standards on infection control.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links