Materials and Methods: The study comprised of two groups. For the first group, 50 unpaired dry femur bones were obtained from adult human cadavers; and the second group was a clinical group of 50 adult patients. Standardised radiographic techniques were used to measure the extra-cortical and intra-cortical morphometric parameters. Based on these, dimensionless ratios were calculated to express the shape of the proximal femur. The data were expressed in terms of mean and standard deviation and a comparison made with other studies.
Results: A significant difference was noted across various population subsets within the Indian subcontinent and also in comparison to the Western population, suggestive of regional variation. The measurements made in cadaveric bone differed significantly from those in live patients, especially the femoral head diameter and extra-cortical and intra-cortical width. Femoral offset, head height and diameter were significantly less in females.
Conclusion: The south Indian population needs customised implants with an increase in neck shaft angle and a decrease in intra-cortical and extra-cortical width for press fit in hip arthroplasty. The variation between the two sexes must also be accounted for during prosthesis design.
METHODS: Twenty-four studies met the inclusion criteria including 1761 cadaveric limbs.
RESULTS: The results were as following: (a) the mean palmaris longus tendon length was of 13.9 ± 2.6 cm, (b) the mean ratio palmaris longus tendon length/forearm length was of 0.545 ± 0.06, (c) the weighted correlation value was of 0.686, and (d) the mean palmaris longus tendon width was of 4.0 ± 1.7 mm. Only five studies reported a palmaris longus tendon length of more than 15 cm. The palmaris longus tendon length was shown to vary between ancestries; the Japanese had the shortest while Malaysian the longest palmaris longus tendons. All studies but one reported a palmaris longus tendon mean width of more than 3 mm where the minimal mean palmaris longus tendon width was of 2.5 mm.
CONCLUSION: While the requested length depends on the recipient site and/or type of reconstructive surgery, the palmaris longus tendon often met the required diameter for grafting. Our review demonstrated that while palmaris longus length varies between ancestries, its width is often adequate for grafting. In addition, the forearm length could be a good predictor of palmaris longus tendon length; such correlation could assist surgeons when planning to use palmaris longus tendon as a graft source.
METHODS: The present study consisted of 50 lower limbs from formalin-fixed male adult cadavers aged about 70 years (45-85) belonging to the South Indian population. Total length of the quadriceps tendon, patellar height, patellar ligament height, proximal width, distal width and thickness of the patellar ligament were measured meticulously. Mean, standard deviation, median scores of each parameter were computed for groups using SPSS 16.0. Level of significance was considered as p