Displaying publications 81 - 100 of 470 in total

Abstract:
Sort:
  1. Mustapha, I., Takriff, M.S., Kamaruddin, S.K., Hassan, N.M., Zain, R.M.
    MyJurnal
    Electrical capacitance tomography (ECT) velocimetry technique was utilized in this study to quantify the flow structure of gas-liquid based on the ECT images. A new 8 electrodes sensor ECT has been successfully developed to provide 2D images in a cross section of pipeline. The ECT has been attentively applied in the test section of the flow rig for imaging the gas-liquid distribution. The inside diameter of ECT pipeline sensor is 100mm. Meanwhile, the flow rig consists of close loop of “CPVC” pipes that includes a pipe test section, two tanks of oil and water respectively and allows the working pressure up to 5 bars. Transparent pipe is used for visual monitoring. A portable Doppler flow meter that utilizes the ultrasonic signal has also been placed at the test section to measure the velocity. The images obtained by ECT show that the different flow patterns have been observed in the horizontal pipe during the experiment. The technique enables realization of the time and position at which particle density fluctuations with respect to dominant time-space levels pass through the pipeline.
    Matched MeSH terms: Electrodes
  2. Mazni Mustafa, W. Mohamad Daud W. Yusoff, Zainal Abidin Talib, Abdul Halim Shaari, Primus, Walter Charles
    MyJurnal
    Ca0.5Sr0.5Cu3Ti4O12 (CSCTO) ceramic oxide was prepared using solid state reaction technique. Impedance measurement was done using High Dielectric Resolution Analyzer (Novocontrol Novotherm) from 30 oC to 250 oC, in the frequency range of 10-2 to 106 Hz. X-ray diffraction pattern showed a single phase with a cubic structure. In the complex impedance plot, three semi-circles were observed; these represented the grain, grain boundary and electrode effect responses. The semi-circles were fitted using a series network of three parallel RC circuits. The resistance was found to increase with the decreasing temperature. The activation energies, Ea, obtained from the Arrhenius plots of CSCTO, were 0.31 eV and 0.73 eV for grain and grain boundary conductivity, respectively. The value of the grain energy was revealed as smaller than the grain boundary energy, due to the semi-conducting grain and the insulating grain boundary characteristic (Sinclair et al., 2002).
    Matched MeSH terms: Electrodes
  3. Syed Baharom Syed Osman, Mohammad Nabil Fikri, Fahad Irfan Siddique
    MyJurnal
    The long term objective of this research is to look into the possibility of replacing soil strength parameters such as cohesion and angle of friction with electrical resistivity value for the purpose of computing among others, factor of safety in slopes or bearing capacity of soil. This paper however is limited to the investigation of correlation between electrical resistivity with some selected soil parameters. Electrical resistivity tests, using a basic multi meter, steel moulds and other related equipment, were conducted in the laboratory on soil samples with variations in soil type, compaction energy and moisture content. The samples consisted of predominantly clay, silt and sandy size particles and were compacted in a 100 x 100 mm square mould, while the corresponding electrical resistivity tests were carried out using the disc electrode method in accordance to BS 1377. The values of the electrical parameters such as voltage, current and resistance, with the corresponding value of soil parameters such as cohesion, angle of friction and moisture content, were measured and recorded. The results of the tests produced some initial crude relationships between electrical resistivity and the selected soil parameters. The strongest correlation between electrical resistivity and angle of internal friction, φ, was obtained from the clay size samples with R2 of 0.824, while the maximum correlation between electrical resistivity and moisture content again was obtained through the clay samples with R2 of 0.818. From the other results and graphs analyzed, some consistencies and specific trends of behaviour observed gave some early indications that a more detail and precise correlation between electrical resistivity and soil strength parameters could be very well possible in future.
    Matched MeSH terms: Electrodes
  4. Nur Syuhaidah Mohd Aris, Shariff Ibrahim, Borhannuddin Arifin, Yahaya Hawari
    MyJurnal
    Electrocoagulation has proven to be an effective method in the treatment of wastewater. This study evaluated the decolourisation of Palm Oil Mill Effluent (POME) using electrocoagulation (EC) batch reactor by utilising aluminium as sacrificial electrode. POME sample source from a final discharged pond at a palm oil mill was characterised for its colour, chemical oxygen demand (COD), pH, conductivity and turbidity; were found to be 2707 PtCo, 3909 mg/L, 7.63, 12.82 mS/cm and 755 NTU respectively. The respective effects of operating parameters such as pH (3 to 11), applied voltage (5 V to 20 V), plate gap (7.5 to 11.5 cm) and operating time (1 to 8 hours) were investigated. The decolourisation of POME was observed to increase with increasing voltage and operating time. Highest removal efficiency was observed at pH 5, 20 V applied voltage, 9.5 cm plate gap and at 8-hour operating time with colour removal efficiency of 89, 79, 78 and 64% respectively. From the findings, it can be concluded that electrocoagulation process using aluminium electrodes is a reliable technique for the removal of colour from POME.
    Matched MeSH terms: Electrodes
  5. Norhafiz Azis, Yee Von Thien, Robiah Yunus, Zaini Yaakub
    MyJurnal
    In recent years, vegetable oil such as Palm Oil (PO) has been identified as a potential alternative dielectric insulating fluid for transformers. It is biodegradable, non-toxic and has high flash and fire points. In this paper, a study on the positive lightning impulse breakdown voltages of PO under non-uniform field is carried out. The testing was carried out using needle-plane electrodes configuration at gap distances of 25 mm and 50 mm. Rising voltage, 1 and 3 shots per step testing methods were used and 3 types of Refined Bleach and Deodorized Palm Oil (RBDPO) and Mineral Oil (MO) were examined. It was found there is no significant effect on the breakdown voltages of all samples. The breakdown voltages of all RBDPO at 50% probability are comparable with MO. At 1% probability and gap distance of 50 mm, the breakdown voltages of all RBDPO are lower than MO.
    Matched MeSH terms: Electrodes
  6. Shukla V, Hussin FA, Hamid NH, Zain Ali NB
    Sensors (Basel), 2017 Jul 27;17(8).
    PMID: 28749411 DOI: 10.3390/s17081719
    With the advancement of digital microfluidics technology, applications such as on-chip DNA analysis, point of care diagnosis and automated drug discovery are common nowadays. The use of Digital Microfluidics Biochips (DMFBs) in disease assessment and recognition of target molecules had become popular during the past few years. The reliability of these DMFBs is crucial when they are used in various medical applications. Errors found in these biochips are mainly due to the defects developed during droplet manipulation, chip degradation and inaccuracies in the bio-assay experiments. The recently proposed Micro-electrode-dot Array (MEDA)-based DMFBs involve both fluidic and electronic domains in the micro-electrode cell. Thus, the testing techniques for these biochips should be revised in order to ensure proper functionality. This paper describes recent advances in the testing technologies for digital microfluidics biochips, which would serve as a useful platform for developing revised/new testing techniques for MEDA-based biochips. Therefore, the relevancy of these techniques with respect to testing of MEDA-based biochips is analyzed in order to exploit the full potential of these biochips.
    Matched MeSH terms: Electrodes
  7. Hindatu Y, Annuar MSM, Subramaniam R, Gumel AM
    Bioprocess Biosyst Eng, 2017 Jun;40(6):919-928.
    PMID: 28341913 DOI: 10.1007/s00449-017-1756-4
    Insufficient power generation from a microbial fuel cell (MFC) hampers its progress towards utility-scale development. Electrode modification with biopolymeric materials could potentially address this issue. In this study, medium-chain-length poly-3-hydroxyalkanoates (PHA)/carbon nanotubes (C) composite (CPHA) was successfully applied to modify the surface of carbon cloth (CC) anode in MFC. Characterization of the functional groups on the anodic surface and its morphology was carried out. The CC-CPHA composite anode recorded maximum power density of 254 mW/m2, which was 15-53% higher than the MFC operated with CC-C (214 mW/m2) and pristine CC (119 mW/m2) as the anode in a double-chambered MFC operated with Escherichia coli as the biocatalyst. Electrochemical impedance spectroscopy and cyclic voltammetry showed that power enhancement was attributed to better electron transfer capability by the bacteria for the MFC setup with CC-CPHA anode.
    Matched MeSH terms: Electrodes
  8. Seman RNAR, Azam MA, Ani MH
    Nanotechnology, 2018 Dec 14;29(50):502001.
    PMID: 30248022 DOI: 10.1088/1361-6528/aae3da
    Supercapacitors, based on fast ion transportation, are among the most promising energy storage solutions that can deliver fast charging-discharging within seconds and exhibit excellent cycling stability. The development of a good electrode material is one of the key factors in enhancing supercapacitor performance. Graphene (G), an allotrope of carbon that consists of a single layer of carbon atoms arranged in a hexagonal lattice, elicits research attention among scientists in the field of energy storage due to its remarkable properties, such as outstanding electrical conductivity, good chemical stability, and excellent mechanical behavior. Furthermore, numerous studies focus on 2D materials that are analogous to graphene as electrode supercapacitors, including transition metal dichalcogenides (TMDs). Recently, scientists and researchers are exploring TMDs because of the distinct features that make 2D TMDs highly attractive for capacitive energy storage. This study provides an overview of the structure, properties, synthesis methods, and electrochemical performance of G/TMD supercapacitors. Furthermore, the combination of G and TMDs to develop a hybrid structure may increase their energy density by introducing an asymmetric supercapacitor system. We will also discuss the future prospect of this system in the energy field.
    Matched MeSH terms: Electrodes
  9. Jumat Salimon
    Sains Malaysiana, 2007;36:27-32.
    The adsorption of CO at polycrystalline copper surface was investigated spectroscopically. It was found that CO adsorbed as a linear adsorbed CO, Cu-COL and was a dominant species on copper surface at low CO concentration. A Cu-COL was electrochemically converted to a bridge bonded CO, Cu-COB at a high CO concentration condition. Increasing the CO surface coverage, qCO will increase the formation of adsorbed bridge bonded CO. A nitrogen gas purging treatment was used to examine the stability of an adsorbed CO through the evacuation process. The result showed that Cu-COB remained intact while Cu-COL was completely removed from the copper surface. It suggests that Cu-COL may involve in a weak bonding to a copper surface such as in a physisorbed interaction, while Cu-COB consists much stronger bonding such as a chemisorbed interaction. The N2 purging treatment also gave an additional prove that Cu-COB was partly converted to Cu(I)-CO at anodic potential regions.
    Matched MeSH terms: Electrodes
  10. Solhan Yahya, Norinsan Kamil Othman, Abd Razak Daud, Azman Jalar
    Sains Malaysiana, 2014;43:1083-1087.
    The effect of scan rate on the accuracy of corrosion parameter in evaluating the efficiency of rice straw extract as corrosion inhibitor has been studied via potentiodynamic polarization measurement. Scan rate in the range of low (0.1- 0.25 mV s-1), medium (0.5-1.0 mV s-1) and high (1.5-2.0 mV s-1) scan were carried out on the carbon steel in 1 M HCl. The corrosion parameters such as corrosion rate, polarization resistance and corrosion current density have been analyzed through Tafel polarization curve. High scan rate gave poor accuracy of corrosion parameter compared to medium and low scan. Medium scan at 1.0 mV s-1 has been chosen as the optimum scan rate due to the approached steady-state and small disturbance of charged current. As a result, the addition of rice straw extract in 1 M HCl has reduced the values of corrosion current density in both cathodic and anodic reactions signified the corrosion has been inhibited. The efficiency of rice straw extracts as a corrosion inhibitor offer good result as much as 86%.
    Matched MeSH terms: Electrodes
  11. Norhani Mohidin, Yap MK, Jacobs RJ
    Sains Malaysiana, 2014;43:1089-1094.
    The purpose of this study was to compare the performance of four different electrode types in detecting the multifocal electroretinogram (mfERG) using the visual evoked response imaging system (VERIS). Multifocal ERG of 30 healthy subjects aged 17-50 years was recorded. Four different types of electrodes were used (JET contact lens, gold foil, DTL thread and c-glide carbon fiber electrodes) and the trough to peak amplitude response densities of the first order kernels (which approximated to the a and b wave of the full field electroretinogram) were compared. The JET contact lens electrode produced the highest amplitude response which was significantly different from the gold foil, DTL thread and the c-glide electrodes, but there was no significant difference between the gold foil and DTL or between DTL and the c-glide electrodes. In conclusion, contact lens electrode produced the highest response density followed by the gold foil and the DTL thread. There was no significant difference in amplitude response between the gold foil and DTL thread, therefore these two electrodes provide for viable alternatives for recording mfERG especially when there are concerns that contact lens electrode may be uncomfortable for recording periods that may take a long time.
    Matched MeSH terms: Electrodes
  12. Abdul Aziz Ahmad, Raihan Othman, Faridah Yusof, Mohd Firdaus Abdul Wahab
    Sains Malaysiana, 2014;43:459-465.
    A hybrid biofuel cell, a zinc-air cell employing laccase as the oxygen reduction catalyst is investigated. A simple cell design is employed; a membraneless single chamber and a freely suspended laccase in the buffer electrolyte. The cell is characterised based on its open-circuit voltage, power density profile and galvanostatic discharge at 0.5 mA. The activity of laccase as an oxidoreductase is substantiated from the cell discharge profiles. The use of air electrode in the cell design enhanced the energy output by 14%. The zinc-air biofuel cell registered an open-circuit voltage of 1.2 V and is capable to deliver a maximum power density of 1.1 mWcm-2 at 0.4 V. Despite its simple design features, the power output is comparable to that of biocatalytic cell utilising a much more complex system design.
    Matched MeSH terms: Electrodes
  13. Jong DL, Park BG, Jung KD
    Sains Malaysiana, 2008;37:233-237.
    Bottom-contact pentacene OTFTs are fabricated using cross-linked poly(vinyl alcohol) (PVA) insulator and its reliability characteristics are analyzed. The hysteresis of the OTFTs is mainly caused by the electrons that are injected from the gate electrode to the cross-linked PVA insulator. To block the injection of electrons, plasma-enhanced chemical vapor deposition (PECVD) SiO2 layer is inserted between the gate electrode and the cross-linked PVA layer, so that the minimum hysteresis can be obtained. In addition, the effects of the gate bias stress as a function of time is investigated to examine the long-term reliability of the device during the operation.
    Matched MeSH terms: Electrodes
  14. Hussin MH
    Data Brief, 2019 Feb;22:971-976.
    PMID: 30740480 DOI: 10.1016/j.dib.2019.01.029
    The anti-corrosion performances of single(TEOS) and hybrid (APTES-TEOS) sol-gel coatings on Al alloy samples exposed to 3.5 wt% NaCl were evaluated employing electrochemical techniques such as electrochemical impedance spectroscopy (EIS) and potentiodynamic polarization. The data acquired using the three corrosion analysis techniques were in accordance with each other where hybrid sol-gel coating offered the lowest corrosion rate and current density in comparison to the single precursor silanol coating. Tafel curves suggested that the hybrid silane coatings mitigate both the anodic and cathodic reactions simultaneously (mixed type inhibitor). These techniques justified that incorporation of hybrid sol-gel improved the Al corrosion protection performance considerably.
    Matched MeSH terms: Electrodes
  15. Soundhar A, Zubar HA, Sultan MTBHH, Kandasamy J
    Data Brief, 2019 Apr;23:103671.
    PMID: 30788395 DOI: 10.1016/j.dib.2019.01.019
    Newly prepared titanium alloy (Ti-13Zr-13Nb (TZN)) using powder metallurgy is considered in this investigation. Titanium alloys (TZN) are used in hip and knee replacement for orthopedic implants. Conventional machining, TZN alloys produce higher tool wear rate and poor surface quality, but this can be reduced by Electrical Discharge Machining (EDM) method. Moreover, EDM produce good biological and corrosion resistant surface. In this research, experiments were conducted by considering the influential process factors such as pulse on time, pulse off time, voltage, and current. The experiments were designed based on Response Surface Methodology (RSM) of face centered central composite design. Analysis of Variance (ANOVA) was conducted to identify the significance process factors and their relation to output responses such as Electrode Wear Rate (EWR), Surface Roughness (SR) and Material Removal Rate (MRR). Further, an empirical model was developed by RSM in order to predict the output responses.
    Matched MeSH terms: Electrodes
  16. Siti Farah Nadiah Rusli, Mimi Hani Abu Bakar, Loh Kee Shyuan, Mohd Shahbudin Mastar, Seratul Jemiah Abdul Rani, Mohd Shahbudin Mastar
    Sains Malaysiana, 2018;47:3017-3023.
    Aryl diazonium salts are coupling agents that assist in molecules attachment to interfaces for sensing purposes. Despite
    not being fully explored and not yet widely applicable for cell-based sensors, the high stability of aryl diazonium salt
    formed sensing system is highly favorable in biological applications. Carbon-based electrodes are the most commonly
    used in aryl diazonium modification due to its post grafting stable C-C bond formation. Here, salt bridge based microbial
    fuel cells (MFCs) were used to study on the effect of aryl diazonium modification on the anode graphite fibre brush. Aryl
    diazonium salts were in situ generated by the diazonation of p-phenylenediamine with NaNO2 in HCl solution. The
    electrochemical performance of the aryl diazonium modified graphite brush MFC was measured and compared with the
    unmodified graphite brush MFC. The power output of the modified graphite brush bioanode was higher (8.33 W/m3
    )
    than the unmodified graphite brush (7.60 W/m3
    ) after 20 days of operation with ferricyanide as the catholyte. After 70
    days of operation using phosphate buffer solution as the catholyte, the Pmax of modified brush was three times higher
    (0.06 W/m3
    ) than of the unmodified brush (0.02 W/m3
    ), which indicates an enhanced binding towards the substrate that
    facilitates a better electron transfer between the microbial and electrode surface.
    Matched MeSH terms: Electrodes
  17. Al-Sahari M, Al-Gheethi A, Radin Mohamed RMS, Noman E, Naushad M, Rizuan MB, et al.
    Chemosphere, 2021 Dec;285:131373.
    PMID: 34265718 DOI: 10.1016/j.chemosphere.2021.131373
    Millions of litters of multifarious wastewater are directly disposed into the environment annually to reduce the processing costs leading to eutrophication and destroying the clean water sources. The bioelectrochemical systems (BESs) have recently received significant attention from researchers due to their ability to convert waste into energy and their high efficiency of wastewater treatment. However, most of the performed researches of the BESs have focused on energy generation, which created a literature gap on the utilization of BESs for wastewater treatment. The review highlights this gap from various aspects, including the BESs trends, fundamentals, applications, and mechanisms. A different review approach has followed in the present work using a bibliometric review (BR) which defined the literature gap of BESs publications in the degradation process section and linked the systematic review (SR) with it to prove and review the finding systematically. The degradation mechanisms of the BESs have been illustrated comprehensively in the current work, and various suggestions have been provided for supporting future studies and cooperation.
    Matched MeSH terms: Electrodes
  18. Lam SM, Sin JC, Zeng H, Lin H, Li H, Mohamed AR, et al.
    Chemosphere, 2022 Jan;287(Pt 4):132384.
    PMID: 34597645 DOI: 10.1016/j.chemosphere.2021.132384
    BiFeO3 nanoparticle decorated on flower-like ZnO (BiFeO3/ZnO) was fabricated through a facile hydrothermal-reflux combined method. This material was utilized as a composite photocathode for the first time in microbial fuel cell (MFC) to reduce the copper ion (Cu2+) and power generation concomitantly. The resultant BiFeO3/ZnO-based MFC displayed distinct photoelectrocatalytic activities when different weight percentages (wt%) BiFeO3 were used. The 3 wt% BiFeO3/ZnO MFC achieved the maximum power density of 1.301 W m-2 in the catholyte contained 200 mg L-1 of Cu2+ and the power density was greatly higher than those pure ZnO and pure BiFeO3 photocathodes. Meanwhile, the MFC exhibited 90.7% removal of Cu2+ within 6 h under sunlight exposure at catholyte pH 4. The addition of BiFeO3 nanoparticles not only manifested outstanding capability in harvesting visible light, but also facilitated the formation of Z-scheme BiFeO3/ZnO heterojunction structure to induce the charge carrier transfer along with enhanced redox abilities for the cathodic reduction. The pronounced electrical output and Cu2+ reduction efficiencies can be realized through the synergistic cooperation between the bioanode and BiFeO3/ZnO photocathode in the MFC. Furthermore, the developed BiFeO3/ZnO composite presented a good stability and reusability of photoelectrocatalytic activity up to five cyclic runs.
    Matched MeSH terms: Electrodes
  19. Mazlan SZ, Lee YH, Hanifah SA
    Sensors (Basel), 2017 Dec 09;17(12).
    PMID: 29232842 DOI: 10.3390/s17122859
    Laccase enzyme, a commonly used enzyme for the construction of biosensors for phenolic compounds was used for the first time to develop a new biosensor for the determination of the azo-dye tartrazine. The electrochemical biosensor was based on the immobilization of laccase on functionalized methacrylate-acrylate microspheres. The biosensor membrane is a composite of the laccase conjugated microspheres and gold nanoparticles (AuNPs) coated on a carbon-paste screen-printed electrode. The reaction involving tartrazine can be catalyzed by laccase enzyme, where the current change was measured by differential pulse voltammetry (DPV) at 1.1 V. The anodic peak current was linear within the tartrazine concentration range of 0.2 to 14 μM (R² = 0.979) and the detection limit was 0.04 μM. Common food ingredients or additives such as glucose, sucrose, ascorbic acid, phenol and sunset yellow did not interfere with the biosensor response. Furthermore, the biosensor response was stable up to 30 days of storage period at 4 °C. Foods and beverage were used as real samples for the biosensor validation. The biosensor response to tartrazine showed no significant difference with a standard HPLC method for tartrazine analysis.
    Matched MeSH terms: Electrodes
  20. Wang CT, Huang YS, Sangeetha T, Chen YM, Chong WT, Ong HC, et al.
    Bioresour Technol, 2018 May;255:83-87.
    PMID: 29414177 DOI: 10.1016/j.biortech.2018.01.086
    Photosynthetic microbial fuel cells (PMFCs) are novel bioelectrochemical transducers that employ microalgae to generate oxygen, organic metabolites and electrons. Conventional PMFCs employ non-eco-friendly membranes, catalysts and phosphate buffer solution. Eliminating the membrane, buffer and catalyst can make the MFC a practical possibility. Therefore, single chambered (SPMFC) were constructed and operated at different recirculation flow rates (0, 40 and 240 ml/min) under bufferless conditions. Furthermore, maximum power density of 4.06 mW/m2, current density of 46.34 mA/m2 and open circuit potential of 0.43 V and low internal resistance of 611.8 Ω were obtained at 40 ml/min. Based on the results it was decided that SPMFC was better for operation at 40 ml/min. Therefore, these findings provided progressive insights for future pilot and industrial scale studies of PMFCs.
    Matched MeSH terms: Electrodes