Displaying publications 81 - 100 of 1880 in total

Abstract:
Sort:
  1. Korner AF, Gabby T, Kraemer HC
    Early Hum Dev, 1980 Mar;4(1):35-9.
    PMID: 7389624
    Chisholm et al. [4], using samples of Navajo and Malaysian newborns, found a significant positive relation between maternal normotensive blood pressures during the second trimester of pregnancy and at delivery and infant irritability in response to the Brazelton Examination. Measuring spontaneous crying with an electronic activity monitor and using a white middle-class American population, this relation was replicated for mothers with normotensive blood pressures during the third trimester of pregnancy. The combined findings of the 3 studies seem to suggest that maternal blood pressure in the latter part of pregnancy, even when within normal limits, is a factor in how irritable normal newborn infants are.
    Matched MeSH terms: Blood Pressure*
  2. Azahar NM, Ganbaatar G, Kitaoka K, Sawayama Y, Yano Y
    Hypertens Res, 2023 Mar;46(3):781-783.
    PMID: 36642752 DOI: 10.1038/s41440-022-01164-z
    Matched MeSH terms: Blood Pressure/physiology
  3. Esmailiyan M, Amerizadeh A, Vahdat S, Ghodsi M, Doewes RI, Sundram Y
    Curr Probl Cardiol, 2023 Mar;48(3):101034.
    PMID: 34718034 DOI: 10.1016/j.cpcardiol.2021.101034
    High blood pressure (BP) is one of the main modifiable risk factors for cardiovascular disease (CVD) and preventing it greatly reduces the vascular consequences of aging and, along with intensive treatment of hypertension, eliminates a large portion of the burden of CVD-related mortality. Many meta-analyses and studies proved that regular aerobic exercise (AE) reduces BP but most of these studies consider only hypertensive populations or only AE but not resistant exercise or their combination. In this review, we aimed to study the effect of different types of physical activity (PA)/AE on various populations including normotensive, prehypertensive, primary hypertensive, and resistant hypertensive with different comorbidities. We searched PubMed, Web of Science, and Google Scholar for English articles with keywords for physical activity, aerobic exercise, and blood pressure from January 2010 until September 2021. Finally, 24 studies were included. Results showed that chronic or acute AE (long-term or short-term), either alone or as combined with different sessions and programs can reduce systolic and diastolic BP in every group including normotensive, prehypertensive, primary hypertensive, resistant hypertensive individuals and diabetic patients and those with kidney problems but not in people with chronic heart failure. Isometric exercise training showed to be useful in reducing BP in all groups either as low intensity or as high intensity but the rate of reduction was different in terms of gender. AE showed to be effective in terms of BP reduction in a different age range. It can be seen that different types and duration of AE independent of the modality and programs and independent of the BP medical situation of individuals have been successful in terms of BP reduction. For those with chronic heart failure, more concern and help might be needed to decrease BP via exercise.
    Matched MeSH terms: Blood Pressure/physiology
  4. Sansom K, Reynolds A, Dhaliwal SS, Walsh J, Maddison K, Singh B, et al.
    J Sleep Res, 2023 Jun;32(3):e13778.
    PMID: 36330799 DOI: 10.1111/jsr.13778
    Chronotype is linked to adverse health measures and may have important associations with obstructive sleep apnea and blood pressure, but data are limited. This study aimed to determine the separate and combined associations of chronotype with obstructive sleep apnea and blood pressure in a middle-aged community population. Adults (n = 811) from the Raine Study (female = 59.2%; age mean [range] = 56.6 [42.1-76.6] years) were assessed for chronotype (Morningness-Eveningness Questionnaire), blood pressure and hypertension (doctor diagnosed or systolic blood pressure ≥ 140 mmHg and/or diastolic ≥ 90 mmHg), and obstructive sleep apnea at different in-laboratory apnea-hypopnea index thresholds (5, 10, 15 events per hr). Linear and logistic regression models examined relationships between chronotype and the presence and severity of obstructive sleep apnea, blood pressure, hypertension, and blood pressure stratified by obstructive sleep apnea severity at above-mentioned apnea-hypopnea index thresholds. Covariates included age, sex, body mass index, alcohol consumption, smoking, physical activity, sleep duration, anti-hypertensive medication, insomnia, and depressive symptoms. Most participants were categorised as morning (40%) or intermediate (43%), with 17% meeting criteria for evening chronotypes. Participants with apnea-hypopnea index ≥ 15 events per hr and morning chronotype had higher systolic (9.9 mmHg, p 
    Matched MeSH terms: Blood Pressure/physiology
  5. Sim YS, Chong ZY, Azizi J, Goh CF
    PMID: 35700649 DOI: 10.1016/j.jchromb.2022.123316
    Mitragynine is a promising candidate for pain relief and opiate replacement but the investigations for drug delivery are lacking. This study aims to investigate the potential of mitragynine to be delivered through the skin with an emphasis on developing and validating a gradient HPLC-UV analytical method to determine mitragynine in the samples collected during in vitro skin permeation studies. The optimised method involves a gradient elution using a C18 column with a mobile phase comprising acetonitrile and 0.1 %v/v of formic acid (0-1 min: 30:70 to 70:30 (v/v) and hold up to 4 min; 4-6 min: return to 30:70 (v/v) and hold up to 10 min) at a flow rate of 1.2 mL/min. This method was validated based on the standards set by the International Council on Harmonisation guidelines. The method showed mitragynine elution at ∼ 4 min with adequate linearity (R2 ≥ 0.999 for concentration ranges of 0.5-10 and 10-175 μg/mL) and acceptable limits of detection and quantification at 0.47 and 1.43 μg/mL, respectively. The analytical performance is robust with excellent precision and accuracy. This method was used to evaluate the in vitro skin permeation of mitragynine (5 %w/v) from simple solvent systems over 48 hr. The results showed a cumulative amount of mitragynine permeated at ∼ 11 μg/cm2 for dimethyl sulfoxide and ∼ 4 μg/cm2 for propylene glycol. The study not only addressed the issues of the currently available HPLC-UV methods that limit the direct application but also affirmed the potential of mitragynine to be delivered through the skin.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods
  6. Moullaali TJ, Wang X, Woodhouse LJ, Law ZK, Delcourt C, Sprigg N, et al.
    BMJ Open, 2019 Jul 16;9(7):e030121.
    PMID: 31315876 DOI: 10.1136/bmjopen-2019-030121
    INTRODUCTION: Conflicting results from multiple randomised trials indicate that the methods and effects of blood pressure (BP) reduction after acute intracerebral haemorrhage (ICH) are complex. The Blood pressure in Acute Stroke Collaboration is an international collaboration, which aims to determine the optimal management of BP after acute stroke including ICH.

    METHODS AND ANALYSIS: A systematic review will be undertaken according to the Preferred Reporting Items for Systematic review and Meta-Analysis of Individual Participant Data (IPD) guideline. A search of Cochrane Central Register of Controlled Trials, EMBASE and MEDLINE from inception will be conducted to identify randomised controlled trials of BP management in adults with acute spontaneous (non-traumatic) ICH enrolled within the first 7 days of symptom onset. Authors of studies that meet the inclusion criteria will be invited to share their IPD. The primary outcome will be functional outcome according to the modified Rankin Scale. Safety outcomes will be early neurological deterioration, symptomatic hypotension and serious adverse events. Secondary outcomes will include death and neuroradiological and haemodynamic variables. Meta-analyses of pooled IPD using the intention-to-treat dataset of included trials, including subgroup analyses to assess modification of the effects of BP lowering by time to treatment, treatment strategy and patient's demographic, clinical and prestroke neuroradiological characteristics.

    ETHICS AND DISSEMINATION: No new patient data will be collected nor is there any deviation from the original purposes of each study where ethical approvals were granted; therefore, further ethical approval is not required. Results will be reported in international peer-reviewed journals.

    PROSPERO REGISTRATION NUMBER: CRD42019141136.

    Matched MeSH terms: Blood Pressure/physiology
  7. Aminah H, McP Dick J, Grace J
    Tree Physiol, 1997 Jul;17(7):445-52.
    PMID: 14759836
    Single-node leafy stem cuttings of Shorea leprosula Miq. were subjected to a high, intermediate or low irradiance treatment for 16 weeks in an enclosed mist propagation system. Before rooting, maximum photosynthesis of the cuttings occurred at an irradiance of 400 micro mol m(-2) s(-1). Although none of the irradiance treatments affected the number of roots produced per cutting, the numbers of cuttings that formed roots were 50 and 30% in the high irradiance (diurnal range of 0-658 micro mol m(-2) s(-1)) and low irradiance (diurnal range of 0-98 micro mol m(-2) s(-1)) treatments, respectively, compared with 62% in the intermediate irradiance treatment (diurnal range of 0-360 micro mol m(-2) s(-1)). Low rooting frequency of cuttings in the high irradiance treatment was associated with water deficits (maximum leaf-to-air vapor pressure deficit (VPD) = 3.6 kPa), whereas cuttings in the low irradiance treatment had a low rooting frequency because they were below the light compensation point most of the time. In the intermediate irradiance treatment, cuttings withstood a daily maximum VPD of 1-2 kPa and recovered overnight from the previous day's deficit, as indicated by higher relative water content (RWC) and stomatal conductance (g(s)) in the morning than in the previous afternoon and evening. Higher RWC and g(s) of cuttings in all treatments on Days 14 and 21 compared with Day 8 probably indicated recovery from water deficit following severance and insertion of the cuttings in rooting medium. There were negative relationships between stem volume of cuttings and both number of cuttings that rooted and number of roots per cutting.
    Matched MeSH terms: Air Pressure; Vapor Pressure
  8. Ooi JH, Lim R, Seng H, Tan MP, Goh CH, Lovell NH, et al.
    Biomed Eng Online, 2024 Feb 20;23(1):23.
    PMID: 38378540 DOI: 10.1186/s12938-024-01202-6
    PURPOSE: Non-invasive, beat-to-beat variations in physiological indices provide an opportunity for more accessible assessment of autonomic dysfunction. The potential association between the changes in these parameters and arterial stiffness in hypertension remains poorly understood. This systematic review aims to investigate the association between non-invasive indicators of autonomic function based on beat-to-beat cardiovascular signals with arterial stiffness in individuals with hypertension.

    METHODS: Four electronic databases were searched from inception to June 2022. Studies that investigated non-invasive parameters of arterial stiffness and autonomic function using beat-to-beat cardiovascular signals over a period of > 5min were included. Study quality was assessed using the STROBE criteria. Two authors screened the titles, abstracts, and full texts independently.

    RESULTS: Nineteen studies met the inclusion criteria. A comprehensive overview of experimental design for assessing autonomic function in terms of baroreflex sensitivity and beat-to-beat cardiovascular variabilities, as well as arterial stiffness, was presented. Alterations in non-invasive indicators of autonomic function, which included baroreflex sensitivity, beat-to-beat cardiovascular variabilities and hemodynamic changes in response to autonomic challenges, as well as arterial stiffness, were identified in individuals with hypertension. A mixed result was found in terms of the association between non-invasive quantitative autonomic indices and arterial stiffness in hypertensive individuals. Nine out of 12 studies which quantified baroreflex sensitivity revealed a significant association with arterial stiffness parameters. Three studies estimated beat-to-beat heart rate variability and only one study reported a significant relationship with arterial stiffness indices. Three out of five studies which studied beat-to-beat blood pressure variability showed a significant association with arterial structural changes. One study revealed that hemodynamic changes in response to autonomic challenges were significantly correlated with arterial stiffness parameters.

    CONCLUSIONS: The current review demonstrated alteration in autonomic function, which encompasses both the sympathetic and parasympathetic modulation of sinus node function and vasomotor tone (derived from beat-to-beat cardiovascular signals) in hypertension, and a significant association between some of these parameters with arterial stiffness. By employing non-invasive measurements to monitor changes in autonomic function and arterial remodeling in individuals with hypertension, we would be able to enhance our ability to identify individuals at high risk of cardiovascular disease. Understanding the intricate relationships among these cardiovascular variability measures and arterial stiffness could contribute toward better individualized treatment for hypertension in the future.

    SYSTEMATIC REVIEW REGISTRATION: PROSPERO ID: CRD42022336703. Date of registration: 12/06/2022.

    Matched MeSH terms: Blood Pressure/physiology
  9. Yulia DE, Tan S
    Med J Malaysia, 2024 Mar;79(2):206-211.
    PMID: 38553928
    INTRODUCTION: Numerous tonometers are available to measure intraocular pressure (IOP) in children with glaucoma. This review aims to discuss IOP measurement techniques and principles and compare the accuracy, tolerability and ease of use of available tonometers in measuring IOP in paediatric glaucoma patients.

    MATERIALS AND METHODS: A review of observational studies was conducted to discuss the accuracy, tolerability and ease of use of tonometers in measuring IOP in children with glaucoma.

    RESULTS: Goldmann applanation tonometry (GAT) and its portable handheld versions remain the gold standard in measuring IOP. Tono-Pen (Reichert Ophthalmic Instruments, Depew, New York, USA) and rebound tonometer (RBT) both correlate well with GAT. Although both tonometers tend to overestimate IOP, Tono-Pen overestimates more than RBT. Overestimation is more remarkable in higher IOP and corneal pathologies (such as but not limited to scarred cornea and denser corneal opacity). RBT was better tolerated than other tonometers in children and was easier to use in children of all ages.

    CONCLUSIONS: RBT is the preferred tonometer for measuring IOP in children with glaucoma, as it is less traumatic, time efficient and does not require fluorescein dye or anaesthesia. However, examiners should use a second tonometer to confirm elevated IOP readings from the RBT.

    Matched MeSH terms: Intraocular Pressure*
  10. Hoshide S, Kario K, Chia YC, Siddique S, Buranakitjaroen P, Tsoi K, et al.
    J Clin Hypertens (Greenwich), 2021 03;23(3):489-495.
    PMID: 33705599 DOI: 10.1111/jch.14184
    Obstructive sleep apnea (OSA) is a risk of hypertension and is associated with cardiovascular disease (CVD) incidence. In Asian countries, the prevalence of OSA is high, as in Western countries. When blood pressure (BP) is evaluated in OSA individuals using ambulatory BP monitoring (ABPM), the BP phenotype often indicates abnormal BP variability, such as increased nighttime BP or abnormal diurnal BP variation, that is, non-dipper pattern, riser pattern, and morning BP surge, and all these conditions have been associated with increased CVD events. Asians have a higher prevalence of increased nighttime BP or morning BP surge than Westerners. Therefore, this review paper focused on OSA and hypertension from an Asian perspective to investigate the importance of the association between OSA and hypertension in the Asian population. Such abnormal BP variability has been shown to be associated with progression of arterial stiffness, and this association could provoke a vicious cycle between abnormal BP phenotypes and arterial stiffness, a phenomenon recognized as systemic hemodynamic atherothrombotic syndrome (SHATS). OSA may be one of the background factors that augment SHATS. An oxygen-triggered nocturnal oscillometric BP measurement device combined with a pulse oximeter for continuous SpO2 monitoring could detect BP variability caused by OSA. In addition to treating the OSA, accurate and reliable detection and treatment of any residual BP elevation and BP variability caused by OSA would be necessary to prevent CVD events. However, more detailed detection of BP variability, such as beat-by-beat BP monitoring, would further help to reduce CV events.
    Matched MeSH terms: Blood Pressure; Blood Pressure Monitoring, Ambulatory
  11. Huang HC, Cheng HM, Chia YC, Li Y, Van Minh H, Siddique S, et al.
    J Clin Hypertens (Greenwich), 2022 Sep;24(9):1187-1193.
    PMID: 36196464 DOI: 10.1111/jch.14554
    Recent trials have demonstrated the efficacy and safety of percutaneous renal sympathetic denervation (RDN) for blood pressure (BP)-lowering in patients with uncontrolled hypertension. Nevertheless, major challenges exist, such as the wide variation of BP-lowering responses following RDN (from strong response to no response) and lack of feasible and reproducible peri-procedural predictors for patient response. Both animal and human studies have demonstrated different patterns of BP responses following renal nerve stimulation (RNS), possibly related to varied regional proportions of sympathetic and parasympathetic nerve tissues along the renal arteries. Animal studies of RNS have shown that rapid electrical stimulation of the renal arteries caused renal artery vasoconstriction and increased norepinephrine secretion with a concomitant increase in BP, and the responses were attenuated after RDN. Moreover, selective RDN at sites with strong RNS-induced BP increases led to a more efficient BP-lowering effect. In human, when RNS was performed before and after RDN, blunted changes in RNS-induced BP responses were noted after RDN. The systolic BP response induced by RNS before RDN and blunted systolic BP response to RNS after RDN, at the site with maximal RNS-induced systolic BP response before RDN, both correlated with the 24-h ambulatory BP reductions 3-12 months following RDN. In summary, RNS-induced BP changes, before and after RDN, could be used to assess the immediate effect of RDN and predict BP reductions months following RDN. More comprehensive, large-scale and long term trials are needed to verify these findings.
    Matched MeSH terms: Blood Pressure/physiology
  12. Wang JG, Li Y, Chia YC, Cheng HM, Minh HV, Siddique S, et al.
    J Clin Hypertens (Greenwich), 2021 03;23(3):435-439.
    PMID: 33484617 DOI: 10.1111/jch.14194
    The prevalence of hypertension is high and still increasing in almost all communities regardless of high, middle, or low income. The control rate remains low in most countries. Telemedicine offers possibilities to improve blood pressure control. The past two decades witnessed the fast evolving telecommunication from telephone transmission to smart mobile phone technology for telemedicine. There is some evidence from randomized controlled trials that telemonitoring improves blood pressure control. However, it requires co-interventions. The emerging new technology may offer even more possibilities in telemonitoring and co-interventions, for instance, an interactive platform between patients and health professionals for the management of hypertension. Telemedicine might ultimately change the situation of the unsatisfactory management of hypertension in many communities. It helps fully utilize antihypertensive treatment, the most effective cardiovascular prevention, to achieve the goal of ending atherosclerosis and arteriosclerosis in humans.
    Matched MeSH terms: Blood Pressure; Blood Pressure Monitoring, Ambulatory
  13. Cheng HM, Chuang SY, Wang TD, Kario K, Buranakitjaroen P, Chia YC, et al.
    J Clin Hypertens (Greenwich), 2020 03;22(3):391-406.
    PMID: 31841279 DOI: 10.1111/jch.13758
    Since noninvasive central blood pressure (BP) measuring devices are readily available, central BP has gained growing attention regarding its clinical application in the management of hypertension. The disagreement between central and peripheral BP has long been recognized. Some previous studies showed that noninvasive central BP may be better than the conventional brachial BP in association with target organ damages and long-term cardiovascular outcomes. Recent studies further suggest that the central BP strategy for confirming a diagnosis of hypertension may be more cost-effective than the conventional strategy, and guidance of hypertension management with central BP may result in less use of medications to achieve BP control. Despite the use of central BP being promising, more randomized controlled studies comparing central BP-guided therapeutic strategies with conventional care for cardiovascular events reduction are required because noninvasive central and brachial BP measures are conveniently available. In this brief review, the rationale supporting the utility of central BP in clinical practice and relating challenges are summarized.
    Matched MeSH terms: Blood Pressure; Blood Pressure Determination
  14. Park S, Kario K, Chia YC, Turana Y, Chen CH, Buranakitjaroen P, et al.
    J Clin Hypertens (Greenwich), 2020 Mar;22(3):438-444.
    PMID: 31851429 DOI: 10.1111/jch.13762
    Epidemiologic studies have consistently demonstrated an increased risk of cardiovascular disease during colder temperatures. Hemodynamic changes associated with cold temperature and an increase in thrombogenicity may both account for the increase in cardiovascular risk and mortality. Studies using both in-office and out-of-office BP measurements have consistently shown an elevation in BP during the colder seasons. The large difference in BP between cold and warm months may increase the incidence of hypertension and reduce the hypertension control rate, potentially resulting in increased cardiovascular risk, especially among those at risk of cardiovascular disease. The current trends in global warming and climate change may have a profound impact on the epidemiology of hypertension and cardiovascular disease, as changes in the climate may significantly affect both BP variability and cardiovascular disease, especially in those with high cardiovascular risk and the elderly. Furthermore, climate change could have a significant influence on hypertension in Asia, considering the unique characteristics of hypertensive patients in Asia. As an increase in ambient temperature decreases the mean daytime average and morning surge in BP, but increases the nocturnal BP, it is difficult to predict how environmental changes will affect the epidemiology and prognosis of hypertension in the Asian-Pacific region. However, these seasonal variations in BP could be minimized by adjusting the housing conditions and using anticipation medicine. In this review, we discuss the impact of seasonal variation in the ambient temperature on hypertension and cardiovascular disease and discuss how this may impact the epidemiology of hypertension and cardiovascular disease.
    Matched MeSH terms: Blood Pressure; Blood Pressure Monitoring, Ambulatory
  15. Chia YC, Kario K
    J Clin Hypertens (Greenwich), 2020 03;22(3):497-500.
    PMID: 31693281 DOI: 10.1111/jch.13721
    Cardiovascular disease (CVD) accounts for a third of all deaths in Malaysia. The background CV risk of Malaysia is much higher than that of developed countries in the west and in Asia. This high CV mortality is contributed by the high prevalence of CV risk factors especially hypertension which is very prevalent, coupled with low awareness and low control rates. This highlights the importance of home blood pressure measurements (HBPM). HBPM is an important adjunct in the management of hypertension, particularly to identify those unaware as well as white-coat hypertension which is high in treated hypertensive patients in Malaysia. Ownership of HBPM devices in Malaysia is high, and this is an opportunity as well as timely to encourage more use of HBPM. The Malaysian national guidelines do not require HBPM for the diagnosis of hypertension but do recommend HBPM for specific situations. The most commonly prescribed anti-hypertensives are calcium channel blockers, followed by renin-angiotensin system blockers. Despite the wide availability of anti-hypertensive agents, BP control rates remain low. It is important that strategies are in place to ensure that individuals are aware of the need to have their BP monitored regularly and this can be facilitated by the use of HBPM. Hence, there is a plan to develop a local HBPM consensus document. Strategies to reduce salt intake would also be beneficial. In summary, identification of those unaware and better control of BP with the help of HBPM would help reduce the burden of CV mortality and morbidity in Malaysia.
    Matched MeSH terms: Blood Pressure; Blood Pressure Monitoring, Ambulatory
  16. Tang MY, Tang IP, Wang CY
    Med J Malaysia, 2014 Aug;69(4):151-5.
    PMID: 25500841 MyJurnal
    AIM: This was a randomized single blinded study to determine optimal size for Ambu®LMA (ALMA) among Malaysian adult population.

    METHODS: One hundred and twenty six non-paralyzed anaesthetized adult patients were block randomized into size 3, 4 and 5 Ambu®LMA. Optimal size is defined primarily by oropharyngeal pressure (OLP). Pharyngeal injury and ease of insertion are also taken into consideration.

    RESULTS: Mean OLP was significantly higher for Size 4 and 5 compared to size 3 (p<0.001) but similar between size 4 and 5. Number of insertion attempts and insertion time were similar between sizes. Size 5 required more manipulations during insertion (p<0.005) and had higher pharyngeal injury (p=0.001) compared to size 3 and 4.

    DISCUSSION: We recommend size 4 ALMA as the optimal size for Malaysian adults in view of the higher OLP compared to size 3, yet less pharyngeal injury than size 5 in spontaneously breathing patients.
    Matched MeSH terms: Pressure
  17. Mohammad Haniff MA, Lee HW, Bien DC, Teh AS, Azid IA
    Nanoscale Res Lett, 2014;9(1):49.
    PMID: 24472487 DOI: 10.1186/1556-276X-9-49
    This paper presents a functionalized, horizontally oriented carbon nanotube network as a sensing element to enhance the sensitivity of a pressure sensor. The synthesis of horizontally oriented nanotubes from the AuFe catalyst and their deposition onto a mechanically flexible substrate via transfer printing are studied. Nanotube formation on thermally oxidized Si (100) substrates via plasma-enhanced chemical vapor deposition controls the nanotube coverage and orientation on the flexible substrate. These nanotubes can be simply transferred to the flexible substrate without changing their physical structure. When tested under a pressure range of 0 to 50 kPa, the performance of the fabricated pressure sensor reaches as high as approximately 1.68%/kPa, which indicates high sensitivity to a small change of pressure. Such sensitivity may be induced by the slight contact in isolated nanotubes. This nanotube formation, in turn, enhances the modification of the contact and tunneling distance of the nanotubes upon the deformation of the network. Therefore, the horizontally oriented carbon nanotube network has great potential as a sensing element for future transparent sensors.
    Matched MeSH terms: Pressure
  18. Ghanbarian A, Rezaei-Ghaleh N, Salehi P, Azizi F
    Med J Malaysia, 2006 Oct;61(4):433-7.
    PMID: 17243520
    Significant hypertension in adolescence is defined according to Blood Pressure (BP) distribution among general population. The present study was conducted to determine the BP distribution in Iranian adolescents. In a population-based study held in Tehran, BP data for 2560 participants aged 10-17 years (1247 boys and 1313 girls) were collected. The 90th and 95th percentiles of systolic (SBP) and diastolic BP (DBP) were obtained for different age and height subgroups of boys and girls. While the 90th and 95th percentiles of SBP obtained in our study were generally lower than international guidelines, the corresponding percentiles of DBP were higher. Significant associations were found between BP and age, height, weight and BMI. According to our findings, it is necessary to prepare BP reference tables according to regional surveys.
    Matched MeSH terms: Blood Pressure*; Blood Pressure Determination*
  19. Aris IB, Wagie AA, Mariun NB, Jammal AB
    J Telemed Telecare, 2001;7(1):51-3.
    PMID: 11265939
    We developed a personal blood pressure monitoring system for patients with hypertension or hypotension. The system can be used to measure a patient's blood pressure at home and to transmit the data automatically to a hospital database via the Internet. The accuracy of blood pressure readings using the system was assessed by comparison with readings from a standard digital sphygmomanometer in four subjects. The measurement error for the systolic readings was 1.7-2.7% and for the diastolic readings 2.7-3.2%. The system therefore appears to be a promising means of assessing blood pressure remotely.
    Matched MeSH terms: Blood Pressure/physiology; Blood Pressure Determination/methods*
  20. Ho JJ, Subramaniam P, Henderson-Smart DJ, Davis PG
    PMID: 12076445
    BACKGROUND: Respiratory distress syndrome (RDS) is the single most important cause of morbidity and mortality in preterm infants (Greenough 1998, Bancalari 1992). Intermittent positive pressure ventilation (IPPV) with surfactant is the standard treatment for the condition. The major difficulty with IPPV is that it is invasive, resulting in airway and lung injury and contributing to the development of chronic lung disease.

    OBJECTIVES: In spontaneously breathing preterm infants with RDS, to determine if continuous distending pressure (CDP) reduces the need for IPPV and associated morbidity without adverse effects.

    SEARCH STRATEGY: The standard search strategy of the Neonatal Review group was used. This included searches of the Oxford Database of Perinatal Trials, Cochrane Controlled Trials Register (The Cochrane Library, Issue 1, 2002), MEDLINE (1966-January 2002), and EMBASE (1980-January 2002), previous reviews including cross references, abstracts, conference and symposia proceedings, expert informants, journal hand searching mainly in the English language.

    SELECTION CRITERIA: All trials using random or quasi-random allocation of preterm infants with RDS were eligible. Interventions were continuous distending pressure including continuous positive airway pressure (CPAP) by mask, nasal prong, nasopharyngeal tube, or endotracheal tube, or continuous negative pressure (CNP) via a chamber enclosing the thorax and lower body, compared with standard care.

    DATA COLLECTION AND ANALYSIS: Standard methods of the Cochrane Collaboration and its Neonatal Review Group were used, including independent assessment of trial quality and extraction of data by each author.

    MAIN RESULTS: CDP is associated with a lower rate of failed treatment (death or use of assisted ventilation) [summary RR 0.70 (0.55, 0.88), RD -0.22 (-0.35, -0.09), NNT 5 (3, 11)], overall mortality [summary RR 0.52 (0.32, 0.87), RD -0.15 (-0.26, -0.04), NNT 7 (4, 25)], and mortality in infants with birthweights above 1500 g [summary RR 0.24 (0.07, 0.84), RD -0.281 (-0.483, -0.078), NNT 4 (2, 13)]. The use of CDP is associated with an increased rate of pneumothorax [summary RR 2.36 (1.25, 5.54), RD 0.14 (0.04, 0.23), NNH 7 (4, 24)].

    REVIEWER'S CONCLUSIONS: In preterm infants with RDS the application of CDP either as CPAP or CNP is associated with benefits in terms of reduced respiratory failure and reduced mortality. CDP is associated with an increased rate of pneumothorax. The applicability of these results to current practice is difficult to assess, given the intensive care setting of the 1970s when four out of five of these trials were done. Where resources are limited, such as in developing countries, CPAP for RDS may have a clinical role. Further research is required to determine the best mode of administration and its role in modern intensive care settings

    Matched MeSH terms: Intermittent Positive-Pressure Ventilation/adverse effects; Positive-Pressure Respiration/methods*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links