Displaying publications 81 - 100 of 279 in total

Abstract:
Sort:
  1. Mustaza SM, Elsayed Y, Lekakou C, Saaj C, Fras J
    Soft Robot, 2019 06;6(3):305-317.
    PMID: 30917093 DOI: 10.1089/soro.2018.0032
    Robot-assisted surgery is gaining popularity worldwide and there is increasing scientific interest to explore the potential of soft continuum robots for minimally invasive surgery. However, the remote control of soft robots is much more challenging compared with their rigid counterparts. Accurate modeling of manipulator dynamics is vital to remotely control the diverse movement configurations and is particularly important for safe interaction with the operating environment. However, current dynamic models applied to soft manipulator systems are simplistic and empirical, which restricts the full potential of the new soft robots technology. Therefore, this article provides a new insight into the development of a nonlinear dynamic model for a soft continuum manipulator based on a material model. The continuum manipulator used in this study is treated as a composite material and a modified nonlinear Kelvin-Voigt material model is utilized to embody the visco-hyperelastic dynamics of soft silicone. The Lagrangian approach is applied to derive the equation of motion of the manipulator. Simulation and experimental results prove that this material modeling approach sufficiently captures the nonlinear time- and rate-dependent behavior of a soft manipulator. Material model-based closed-loop trajectory control was implemented to further validate the feasibility of the derived model and increase the performance of the overall system.
    Matched MeSH terms: Motion
  2. Sirunyan AM, Tumasyan A, Adam W, Ambrogi F, Bergauer T, Brandstetter J, et al.
    Phys Rev Lett, 2020 May 22;124(20):202001.
    PMID: 32501048 DOI: 10.1103/PhysRevLett.124.202001
    A measurement is reported of the jet mass distribution in hadronic decays of boosted top quarks produced in pp collisions at sqrt[s]=13  TeV. The data were collected with the CMS detector at the LHC and correspond to an integrated luminosity of 35.9  fb^{-1}. The measurement is performed in the lepton+jets channel of tt[over ¯] events, where the lepton is an electron or muon. The products of the hadronic top quark decay t→bW→bqq[over ¯]^{'} are reconstructed as a single jet with transverse momentum larger than 400 GeV. The tt[over ¯] cross section as a function of the jet mass is unfolded at the particle level and used to extract a value of the top quark mass of 172.6±2.5  GeV. A novel jet reconstruction technique is used for the first time at the LHC, which improves the precision by a factor of 3 relative to an earlier measurement. This highlights the potential of measurements using boosted top quarks, where the new technique will enable future precision measurements.
    Matched MeSH terms: Motion
  3. Sirunyan AM, Tumasyan A, Adam W, Ambrogi F, Bergauer T, Dragicevic M, et al.
    Phys Rev Lett, 2020 Apr 24;124(16):162002.
    PMID: 32383915 DOI: 10.1103/PhysRevLett.124.162002
    The polarizations of promptly produced χ_{c1} and χ_{c2} mesons are studied using data collected by the CMS experiment at the LHC, in proton-proton collisions at sqrt[s]=8  TeV. The χ_{c} states are reconstructed via their radiative decays χ_{c}→J/ψγ, with the photons being measured through conversions to e^{+}e^{-}, which allows the two states to be well resolved. The polarizations are measured in the helicity frame, through the analysis of the χ_{c2} to χ_{c1} yield ratio as a function of the polar or azimuthal angle of the positive muon emitted in the J/ψ→μ^{+}μ^{-} decay, in three bins of J/ψ transverse momentum. While no differences are seen between the two states in terms of azimuthal decay angle distributions, they are observed to have significantly different polar anisotropies. The measurement favors a scenario where at least one of the two states is strongly polarized along the helicity quantization axis, in agreement with nonrelativistic quantum chromodynamics predictions. This is the first measurement of significantly polarized quarkonia produced at high transverse momentum.
    Matched MeSH terms: Motion
  4. Mat Noor NA, Shafie S, Admon MA
    PLoS One, 2021;16(5):e0250402.
    PMID: 33956793 DOI: 10.1371/journal.pone.0250402
    The heat and mass transfer on time dependent hydrodynamic squeeze flow of Jeffrey nanofluid across two plates over permeable medium in the slip condition with heat generation/absorption, thermal radiation and chemical reaction are investigated. The impacts of Brownian motion and thermophoresis is examined in the Buongiorno's nanofluid model. Conversion of the governing partial differential equations to the ordinary differential equations is conducted via similarity transformation. The dimensionless equations are solved by imposing numerical method of Keller-box. The outputs are compared with previous reported works in the journals for the validation of the present outputs and found in proper agreement. The behavior of velocity, temperature, and nanoparticles concentration profiles by varying the pertinent parameters are examined. Findings portray that the acceleration of the velocity profile and the wall shear stress is due to the squeezing of plates. Furthermore, the velocity, temperature and concentration profile decline with boost in Hartmann number and ratio of relaxation to retardation times. It is discovered that the rate of heat transfer and temperature profile increase when viscous dissipation, thermophoresis and heat source/sink rises. In contrast, the increment of thermal radiation reduces the temperature and enhances the heat transfer rate. Besides, the mass transfer rate decelerates for increasing Brownian motion in nanofluid, while it elevates when chemical reaction and thermophoresis increases.
    Matched MeSH terms: Motion
  5. Yong CY, Sudirman R, Chew KM
    Sains Malaysiana, 2015;44(12):1661-1669.
    A scalable tracking human model was proposed for recognizing human jogging and walking activities. The model aims to detect and track a particular subject by using wearable sensor. Data collected are in accelerometer readings in three axes and gyroscope readings in three axes. The development of proposed human model is based on the moderating effects on human movements. Two moderators were proposed as the moderating factors of human motion and they are angular velocity and elevation angle. Linear regression is used to investigate the relationship among inputs, moderators and outputs of the model. The result of this study showed that the angular velocity and elevation angle moderators are affecting the relation of research output. Acceleration in x-axis (Ax) and angular velocity in y-axis (Gy) are the two main components in directing
    a motion. Classification between jogging and walking motions was done by measuring the magnitude of angular velocity and elevation angle. Jogging motion was classified and identified with larger angular velocity and elevation angle. The two proposed hypotheses were supported and proved by research output. The result is expected to be beneficial and able to assist researcher in investigating human motions.
    Matched MeSH terms: Motion
  6. Sirunyan AM, Tumasyan A, Adam W, Ambrogi F, Asilar E, Bergauer T, et al.
    Phys Rev Lett, 2017 Sep 15;119(11):111802.
    PMID: 28949210 DOI: 10.1103/PhysRevLett.119.111802
    A search is reported for a narrow vector resonance decaying to quark-antiquark pairs in proton-proton collisions at sqrt[s]=13  TeV, collected with the CMS detector at the LHC. The data sample corresponds to an integrated luminosity of 2.7   fb^{-1}. The vector resonance is produced at large transverse momenta, with its decay products merged into a single jet. The resulting signature is a peak over background in the distribution of the invariant mass of the jet. The results are interpreted in the framework of a leptophobic vector resonance and no evidence is found for such particles in the mass range of 100-300 GeV. Upper limits at 95% confidence level on the production cross section are presented in a region of mass-coupling phase space previously unexplored at the LHC. The region below 140 GeV has not been explored by any previous experiments.
    Matched MeSH terms: Motion
  7. Sirunyan AM, Tumasyan A, Adam W, Asilar E, Bergauer T, Brandstetter J, et al.
    Phys Rev Lett, 2017 Oct 06;119(14):141802.
    PMID: 29053305 DOI: 10.1103/PhysRevLett.119.141802
    A search for charged Higgs bosons produced via vector boson fusion and decaying into W and Z bosons using proton-proton collisions at sqrt[s]=13  TeV is presented. The data sample corresponds to an integrated luminosity of 15.2  fb^{-1} collected with the CMS detector in 2015 and 2016. The event selection requires three leptons (electrons or muons), two jets with large pseudorapidity separation and high dijet mass, and missing transverse momentum. The observation agrees with the standard model prediction. Limits on the vector boson fusion production cross section times branching fraction for new charged physical states are reported as a function of mass from 200 to 2000 GeV and interpreted in the context of Higgs triplet models.
    Matched MeSH terms: Motion
  8. Sirunyan AM, Tumasyan A, Adam W, Asilar E, Bergauer T, Brandstetter J, et al.
    Phys Rev Lett, 2017 Aug 25;119(8):082301.
    PMID: 28952777 DOI: 10.1103/PhysRevLett.119.082301
    The production of jets in association with Z bosons, reconstructed via the μ^{+}μ^{-} and e^{+}e^{-} decay channels, is studied in pp and, for the first time, in Pb-Pb collisions. Both data samples were collected by the CMS experiment at the LHC, at a nucleon-nucleon center-of-mass energy of 5.02 TeV. The Pb-Pb collisions were analyzed in the 0%-30% centrality range. The back-to-back azimuthal alignment was studied in both pp and Pb-Pb collisions for Z bosons with transverse momentum p_{T}^{Z}>60  GeV/c and a recoiling jet with p_{T}^{jet}>30  GeV/c. The p_{T} imbalance x_{jZ}=p_{T}^{jet}/p_{T}^{Z}, as well as the average number of jet partners per Z, R_{jZ}, was studied in intervals of p_{T}^{Z}. The R_{jZ} is found to be smaller in Pb-Pb than in pp collisions, which suggests that in Pb-Pb collisions a larger fraction of partons associated with the Z bosons fall below the 30  GeV/c p_{T}^{jet} threshold because they lose energy.
    Matched MeSH terms: Motion
  9. Lim LK, Yap SL, Bradley DA
    PLoS One, 2018;13(1):e0188009.
    PMID: 29309425 DOI: 10.1371/journal.pone.0188009
    The plasma focus device discussed herein is a Z-pinch pulsed-plasma arrangement. In this, the plasma is heated and compressed into a cylindrical column, producing a typical density of > 1025 particles/m3 and a temperature of (1-3) × 107 oC. The plasma focus has been widely investigated as a radiation source, including as ion-beams, electron-beams and as a source of x-ray and neutron production, providing considerable scope for use in a variety of technological situations. Thus said, the nature of the radiation emission depends on the dynamics of the plasma pinch. In this study of the characteristics of deuteron-beam emission, in terms of energy, fluence and angular distribution were analyzed. The 2.7 kJ plasma focus discharge has been made to operate at a pressure of less than 1 mbar rather than at its more conventional operating pressure of a few mbar. Faraday cup were used to determine deuteron-beam energy and deuteron-beam fluence per shot while CR-39 solid-state nuclear track detectors were employed in studying the angular distribution of deuteron emission. Beam energy and deuteron-beam fluence per shot have been found to be pressure dependent. The largest value of average deuteron energy measured for present conditions was found to be (52 ± 7) keV, while the deuteron-beam fluence per shot was of the order of 1015 ions/m2 when operated at a pressure of 0.2 mbar. The deuteron-beam emission is in the forward direction and is observed to be highly anisotropic.
    Matched MeSH terms: Time and Motion Studies
  10. Piyarathna IE, Thabet AM, Ucgul M, Lemckert C, Lim YY, Tang ZS
    Sensors (Basel), 2023 Jun 01;23(11).
    PMID: 37299984 DOI: 10.3390/s23115257
    Piezoelectric energy harvesting systems have been drawing the attention of the research community over recent years due to their potential for recharging/replacing batteries embedded in low-power-consuming smart electronic devices and wireless sensor networks. However, conventional linear piezoelectric energy harvesters (PEH) are often not a viable solution in such advanced practices, as they suffer from a narrow operating bandwidth, having a single resonance peak present in the frequency spectrum and very low voltage generation, which limits their ability to function as a standalone energy harvester. Generally, the most common PEH is the conventional cantilever beam harvester (CBH) attached with a piezoelectric patch and a proof mass. This study investigated a novel multimode harvester design named the arc-shaped branch beam harvester (ASBBH), which combined the concepts of the curved beam and branch beam to improve the energy-harvesting capability of PEH in ultra-low-frequency applications, in particular, human motion. The key objectives of the study were to broaden the operating bandwidth and enhance the harvester's effectiveness in terms of voltage and power generation. The ASBBH was first studied using the finite element method (FEM) to understand the operating bandwidth of the harvester. Then, the ASBBH was experimentally assessed using a mechanical shaker and real-life human motion as excitation sources. It was found that ASBBH achieved six natural frequencies within the ultra-low frequency range (<10 Hz), in comparison with only one natural frequency achieved by CBH within the same frequency range. The proposed design significantly broadened the operating bandwidth, favouring ultra-low-frequency-based human motion applications. In addition, the proposed harvester achieved an average output power of 427 μW at its first resonance frequency under 0.5 g acceleration. The overall results of the study demonstrated that the ASBBH design can achieve a broader operating bandwidth and significantly higher effectiveness, in comparison with CBH.
    Matched MeSH terms: Motion
  11. AlDahas A, Devecchi V, Deane JA, Falla D
    PLoS One, 2023;18(10):e0292798.
    PMID: 37824590 DOI: 10.1371/journal.pone.0292798
    BACKGROUND: People with chronic neck pain (CNP) often present with impaired neck proprioception. The most widely used clinical test for assessing neck proprioception is cervical joint position sense which measures joint position error (JPE). This clinical test is typically performed using a laser pointer to examine the accuracy of returning to a neutral head position (NHP) or target head position (THP) following active neck movements. The aim of this study was to determine the measurement properties of JPE using a laser pointer when tested in people with and without CNP under a variety of different testing conditions (i.e., different movement directions, sitting versus standing, NHP versus THP).

    METHODS: Forty-three participants (23 asymptomatic and 20 with CNP) underwent neck proprioception testing, returning to a NHP and THP in both sitting and standing positions (six trials for each test). A laser pointer was secured on the participant's forehead and inertial measurement unit (IMU) sensors were placed beneath the laser pointer and at the level of the spinous process of the seventh cervical vertebra. Both the absolute and the constant JPE were assessed.

    FINDINGS: For the asymptomatic participants, good reliability (ICC: 0.79) was found only for right rotation of the THP task in sitting. In standing, good reliability (ICC: 0.77) was only found in flexion for the THP task. In standing, good reliability (ICC: 0.77) was only found for right rotation of the THP for the absolute JPE and left rotation (ICC: 0.85) for the constant error of the NHP task. In those with CNP, when tested in sitting, good reliability was found for flexion (ICC: 0.8) for the absolute JPE and good reliability (ICC range: 0.8-0.84) was found for flexion, extension, and right rotation for the constant JPE. In standing, good reliability (ICC range: 0.81-0.88) was found for flexion, and rotation for the absolute JPE. The constant JPE showed good reliability (ICC: 0.85) for right rotation and excellent reliability (ICC: 0.93) for flexion. Validity was weak to strong (r range: 0.26-0.83) and moderate to very strong (r range: 0.47-0.93) for absolute and constant error respectively, when tested in sitting. In standing, the validity was weak to very strong (0.38-0.96) for the absolute JPE and moderate to very strong (r range: 0.54-0.92) for the constant JPE.

    CONCLUSION: The reliability of the measure of JPE when tested in sitting and standing in both groups showed good reliability, but not for all movements. The results of the current study also showed that the laser pointer correlated well with the Noraxon IMUs, but not for all movements. The results of the current study support the use of the JPE using a laser pointer in clinical and research settings.

    Matched MeSH terms: Range of Motion, Articular
  12. Aboodarda SJ, Shariff MA, Muhamed AM, Ibrahim F, Yusof A
    J Hum Kinet, 2011 Dec;30:5-12.
    PMID: 23487250 DOI: 10.2478/v10078-011-0067-0
    This study was designed to quantify and compare Electromyographic activity (EMG) and applied load in quadriceps muscle within performing high intensity knee extension exercises by Elastic Resistance (ER) and Nautilus Machine (NM). Sixteen male and female subjects (22.4 ± 4.7 yrs) completed 8 RM seated knee extension by NM, elastic tubing with original length (E0) and elastic tubing with 30% decrement of original length (E30). The mean value of EMG and external force were calculated and synchronized across various segments of motion for the three modes of training. The results demonstrated that in the early concentric and late eccentric segments of contraction, NM elicited significantly higher muscle activation than both E30 and E0 (p < 0.05). However, in the mid-concentric and mid-eccentric as well as late concentric and early eccentric segments no significant differences were observed between NM and E30. These findings supported the approach that developing external recoil of force in ER device by reducing 30% of initial length of elastic material can offer similar neuromuscular activation compared with NM. On this basis, E30 can be suggested as an affordable and non-gym based exercise device which has the capacity to provide an appropriate high resistance stimulus to meet the training requirement of athletes.
    Matched MeSH terms: Motion
  13. Yousefi B, Loo CK
    ScientificWorldJournal, 2014;2014:723213.
    PMID: 25276860 DOI: 10.1155/2014/723213
    Research on psychophysics, neurophysiology, and functional imaging shows particular representation of biological movements which contains two pathways. The visual perception of biological movements formed through the visual system called dorsal and ventral processing streams. Ventral processing stream is associated with the form information extraction; on the other hand, dorsal processing stream provides motion information. Active basic model (ABM) as hierarchical representation of the human object had revealed novelty in form pathway due to applying Gabor based supervised object recognition method. It creates more biological plausibility along with similarity with original model. Fuzzy inference system is used for motion pattern information in motion pathway creating more robustness in recognition process. Besides, interaction of these paths is intriguing and many studies in various fields considered it. Here, the interaction of the pathways to get more appropriated results has been investigated. Extreme learning machine (ELM) has been implied for classification unit of this model, due to having the main properties of artificial neural networks, but crosses from the difficulty of training time substantially diminished in it. Here, there will be a comparison between two different configurations, interactions using synergetic neural network and ELM, in terms of accuracy and compatibility.
    Matched MeSH terms: Motion; Motion Perception/physiology*
  14. Wahab AH, Kadir MR, Harun MN, Kamarul T, Syahrom A
    Med Biol Eng Comput, 2017 Mar;55(3):439-447.
    PMID: 27255451 DOI: 10.1007/s11517-016-1525-6
    The present study was conducted to compare the stability of four commercially available implants by investigating the focal stress distributions and relative micromotion using finite element analysis. Variations in the numbers of pegs between the implant designs were tested. A load of 750 N was applied at three different glenoid positions (SA: superior-anterior; SP: superior-posterior; C: central) to mimic off-center and central loadings during activities of daily living. Focal stress distributions and relative micromotion were measured using Marc Mentat software. The results demonstrated that by increasing the number of pegs from two to five, the total focal stress volumes exceeding 5 MPa, reflecting the stress critical volume (SCV) as the threshold for occurrence of cement microfractures, decreased from 8.41 to 5.21 % in the SA position and from 9.59 to 6.69 % in the SP position. However, in the C position, this change in peg number increased the SCV from 1.37 to 5.86 %. Meanwhile, micromotion appeared to remain within 19-25 µm irrespective of the number of pegs used. In conclusion, four-peg glenoid implants provide the best configuration because they had lower SCV values compared with lesser-peg implants, preserved more bone stock, and reduced PMMA cement usage compared with five-peg implants.
    Matched MeSH terms: Range of Motion, Articular/drug effects; Range of Motion, Articular/physiology*
  15. Nisar H, Malik AS, Ullah R, Shim SO, Bawakid A, Khan MB, et al.
    Adv Exp Med Biol, 2015;823:159-74.
    PMID: 25381107 DOI: 10.1007/978-3-319-10984-8_9
    The fundamental step in brain research deals with recording electroencephalogram (EEG) signals and then investigating the recorded signals quantitatively. Topographic EEG (visual spatial representation of EEG signal) is commonly referred to as brain topomaps or brain EEG maps. In this chapter, full search full search block motion estimation algorithm has been employed to track the brain activity in brain topomaps to understand the mechanism of brain wiring. The behavior of EEG topomaps is examined throughout a particular brain activation with respect to time. Motion vectors are used to track the brain activation over the scalp during the activation period. Using motion estimation it is possible to track the path from the starting point of activation to the final point of activation. Thus it is possible to track the path of a signal across various lobes.
    Matched MeSH terms: Motion
  16. Tay BA
    PMID: 25215723
    We study a series of N oscillators, each coupled to its nearest neighbors, and linearly to a phonon field through the oscillator's number operator. We show that the Hamiltonian of a pair of adjacent oscillators, or a dimer, within the series of oscillators can be transformed into a form in which they are collectively coupled to the phonon field as a composite unit. In the weak coupling and rotating-wave approximation, the system behaves effectively as the trilinear boson model in the one excitation subspace of the dimer subsystem. The reduced dynamics of the one excitation subspace of the dimer subsystem coupled weakly to a phonon bath is similar to that of a two-level system, with a metastable state against the vacuum. The decay constant of the subsystem is proportional to the dephasing rate of the individual oscillator in a phonon bath, attenuated by a factor that depends on site asymmetry, intersite coupling, and the resonance frequency between the transformed oscillator modes, or excitons. As a result of the collective effect, the excitation relaxation lifetime is prolonged over the dephasing lifetime of an individual oscillator coupled to the same bath.
    Matched MeSH terms: Motion
  17. Hassan MA, Mahmoodian R, Hamdi M
    Sci Rep, 2014;4:3724.
    PMID: 24430621 DOI: 10.1038/srep03724
    A modified smoothed particle hydrodynamic (MSPH) computational technique was utilized to simulate molten particle motion and infiltration speed on multi-scale analysis levels. The radial velocity and velocity gradient of molten alumina, iron infiltration in the TiC product and solidification rate, were predicted during centrifugal self-propagating high-temperature synthesis (SHS) simulation, which assisted the coating process by MSPH. The effects of particle size and temperature on infiltration and solidification of iron and alumina were mainly investigated. The obtained results were validated with experimental microstructure evidence. The simulation model successfully describes the magnitude of iron and alumina diffusion in a centrifugal thermite SHS and Ti + C hybrid reaction under centrifugal acceleration.
    Matched MeSH terms: Motion
  18. Ali F, Khan I, Samiulhaq, Shafie S
    PLoS One, 2013;8(6):e65223.
    PMID: 23840321 DOI: 10.1371/journal.pone.0065223
    The aim of this study is to present an exact analysis of combined effects of radiation and chemical reaction on the magnetohydrodynamic (MHD) free convection flow of an electrically conducting incompressible viscous fluid over an inclined plate embedded in a porous medium. The impulsively started plate with variable temperature and mass diffusion is considered. The dimensionless momentum equation coupled with the energy and mass diffusion equations are analytically solved using the Laplace transform method. Expressions for velocity, temperature and concentration fields are obtained. They satisfy all imposed initial and boundary conditions and can be reduced, as special cases, to some known solutions from the literature. Expressions for skin friction, Nusselt number and Sherwood number are also obtained. Finally, the effects of pertinent parameters on velocity, temperature and concentration profiles are graphically displayed whereas the variations in skin friction, Nusselt number and Sherwood number are shown through tables.
    Matched MeSH terms: Motion
  19. Wang C, Bea K, Zulkiflee O
    Malays Orthop J, 2013 Nov;7(3):18-20.
    PMID: 25674302 MyJurnal DOI: 10.5704/MOJ.1311.002
    Clavicle fracture is commonly treated conservatively. However uncommon complication can arise causing impingement. We report a patient who sustained distal clavicle fracture and was treated conservatively. However he developed persistent shoulder pain that affected his daily life. Shoulder impingement was diagnosed and arthroscopic subacromioclavicular decompression was done. Following early physiotherapy the early recovery was good with full range of motion of the shoulder.
    Matched MeSH terms: Range of Motion, Articular
  20. Lan BL
    Chaos, 2006 Sep;16(3):033107.
    PMID: 17014212
    The dynamics of a periodically delta-kicked Hamiltonian system moving at low speed (i.e., at speed much less than the speed of light) is studied numerically. In particular, the trajectory of the system predicted by Newtonian mechanics is compared with the trajectory predicted by special relativistic mechanics for the same parameters and initial conditions. We find that the Newtonian trajectory, although close to the relativistic trajectory for some time, eventually disagrees completely with the relativistic trajectory, regardless of the nature (chaotic, nonchaotic) of each trajectory. However, the agreement breaks down very fast if either the Newtonian or relativistic trajectory is chaotic, but very much slower if both the Newtonian and relativistic trajectories are nonchaotic. In the former chaotic case, the difference between the Newtonian and relativistic values for both position and momentum grows, on average, exponentially. In the latter nonchaotic case, the difference grows much slower, for example, linearly on average.
    Matched MeSH terms: Motion
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links