Displaying all 15 publications

Abstract:
Sort:
  1. Ghaemi F, Amiri A
    J Chromatogr A, 2020 Aug 30;1626:461386.
    PMID: 32797858 DOI: 10.1016/j.chroma.2020.461386
    In this study, the microcrystalline cellulose/metal-organic framework 199 hybrid (MCC/MOF-199) was applied as sorbent for the dispersive micro-solid phase-extraction (D-μSPE) of chlorophenols. The D-μSPE method combined with high-performance liquid chromatography- ultraviolet detection (HPLC-UV) was employed to determine of four chlorophenols including 2-chlorophenol (2-CP), 4-chlorophenol (4-CP), 2,3-dichlorophenol (2,3-DCP), and 2,5-dichlorophenol (2,5-DCP) in aqueous. The main parameters of the D-μSPE process that influence the extraction (i.e. the amount of sorbent, elution condition, extraction time, and pH) were investigated and optimized. Based on the outputs, the presence of MCC on the surface of MOF-199 leads to improve the properties of MOF-199 and the MCC/MOF-199 has the highest sorption capacity, durability, and porosity in comparison with MCC and MOF-199. According to the validation study at the optimized conditions, the linearity for the analytes was achieved in the range from 0.1 to 200 ng mL-1 for 2-CP and 4-CP and 0.15 to 200 ng mL-1 for 2,3-DCP and 2,5-DCP with correlation coefficients between 0.9928 and 0.9965. The limits of detection calculated at S/N=3 were in the range of 0.03-0.05 ng mL-1. Besides, the relative standard deviations (RSDs) for three spiking levels (0.2, 10,100 ng mL-1) do not exceed 6.8% and extraction recoveries are between 81.0% and 88.3%. Finally, the D-μSPE-HPLC-UV method was successfully applied to the analysis of CPs in real water samples (mineral, river and wastewater samples) with good recoveries (95.8 to 99.5%) and satisfactory precisions (RSD < 6.8%).
  2. Amiri A, Ghaemi F
    J Chromatogr A, 2021 Jul 05;1648:462168.
    PMID: 33984648 DOI: 10.1016/j.chroma.2021.462168
    In this research, the Cu-based metal-organic framework (MOF-199) was fabricated and coated on the stainless steel mesh as substrates through sol-gel procedure. Then the coated substrates were placed in a small column known as solid-phase extraction cartridge. The SPE based coated stainless steel mesh coupled with high-performance liquid chromatography-UV detector (HPLC-UV) was used for the fast extraction, and quantification of non-steroidal anti-inflammatory drugs (NSAIDs) from human plasma and water samples. To find optimum extraction conditions, the impacts of effective parameters on analytical performance like sample pH, sample volume, type, and volume of desorption solvent were optimized. At the optimized conditions, calibration graphs of analytes were linear in the concentration range of 0.03-300 ng mL-1 for water samples, and 0.1-200 ng mL-1 for plasma samples. The correlation coefficients were in the range of 0.9938 to 0.9989. Also, the limits of detection (LODs) were from 0.01 to 0.02 ng mL-1 for water samples and 0.03 to 0.1 ng mL-1 for plasma samples. The cartridge repeatability was studied at different values, and the relative standard deviations (RSDs%) were achieved between 3.5 and 5.1%. Consequently, this procedure was successfully used in the extraction and detection of NSAIDs in real water and plasma samples with relative recoveries ranged from 93.6 to 99.6%.
  3. Amiri A, Ghaemi F, Maleki B
    Mikrochim Acta, 2019 02 01;186(3):131.
    PMID: 30707373 DOI: 10.1007/s00604-019-3246-7
    Different types of hybrid nanocomposites were prepared from a copper-based metal-organic framework (MOF-199) and graphene (Gr) or fullerene (Fl). The porosity and quality of the nanocomposites were studied by scanning electron microscopy, transmission electron microscopy and BET surface area analysis. The nanocomposites are shown to be viable sorbents for the dispersive micro solid phase extraction of polycyclic aromatic hydrocarbons (PAHs) from environmental water samples. This is due to (a) the presence of MOF-199 which leads to improved adsorption capacity, and (b) the presence of Gr or Fl on the surface of MOF-199 which enhances the interaction with PAHs. Specifically, acenaphthene, anthracene, benz[a]anthracene, fluorene, naphthalene, 2-methylnaphthalene, and pyrene were studied. A comparison of the sorbents shows MOF-199/Gr to possess the highest adsorption affinity and to be most durable, probably a result of the high porosity of graphene. Following desorption with acetonitrile, the PAHs were quantified by GC with FID detection. Under the optimum conditions, limits of detection (at an S/N ratio of 3) range from 3 to 10 pg mL-1, and the analytical ranges are linear at 0.01-100 ng mL-1 of PAHs. The relative standard deviations for five replicates at two spiking levels (0.03 and 50 ng mL-1) range from 5.0 to 7.4%. The applicability of this method was confirmed by analyzing spiked real water samples, and recoveries are between 91.9 and 99.5%. Graphical abstract Different types of the hybrid nanocomposites of the copper-based metal-organic framework MOF-199 with graphene or fullerene were synthesized and used as sorbent for the dispersive micro solid phase extraction of polycyclic aromatic hydrocarbons in environmental water samples.
  4. Rezvani-Eivari M, Amiri A, Baghayeri M, Ghaemi F
    J Chromatogr A, 2016 Aug 16.
    PMID: 27578405 DOI: 10.1016/j.chroma.2016.08.034
    The application of magnetized graphene (G) layers synthesized on the carbon nanofibers (CNFs) (m-G/CNF) was investigated as novel adsorbent for the magnetic solid-phase extraction (MSPE) of polycyclic aromatic hydrocarbons (PAHs) in water samples followed by gas chromatography-flame ionization detector (GC-FID). Six important parameters, affecting the extraction efficiency of PAHs, including: amount of adsorbent, adsorption and desorption times, type and volume of the eluent solvent and salt content of the sample were evaluated. The optimum extraction conditions were obtained as: 5min for extraction time, 20mg for sorbent amount, dichloromethane as desorption solvent, 1mL for desorption solvent volume, 5min for desorption time and 15% (w/v) for NaCl concentration. Good performance data were obtained at the optimized conditions. The calibration curves were linear over the concentration ranges from 0.012 to 100ngmL(-1) with correlation coefficients (r) between 0.9950 and 0.9967 for all the analytes. The limits of detection (LODs, S/N=3) of the proposed method for the studied PAHs were 0.004-0.03ngmL(-1). The relative standard deviations (RSDs) for five replicates at two concentration levels (0.1 and 50ngmL(-1)) of PAHs were ranged from 3.4 to 5.7%. Appropriate relative recovery values, in the range of 95.5-99.9%, were also obtained for the real water sample analysis.
  5. Rafieerad AR, Bushroa AR, Amiri A, Kalaiselvam K, Vellasamy KM, Vadivelu J
    J Hazard Mater, 2018 10 15;360:132-140.
    PMID: 30099356 DOI: 10.1016/j.jhazmat.2018.07.107
    Antibacterial ability is vital in biological approaches as well as functional biomaterials. Besides, cytocompatibility aspect of biologic media, tissue and organs is always concern for appropriate synthesis. From the past, metallic/oxide phases of silver (Ag) material in various macro, micro or nano configurations have been widely used for antibacterial targets. While, background of Ag toxicity within particle, film and composites is posing gradual ion release affected by molecular bounding. Recent researches conducted to control, optimize and neutralize Ag limitations finding the benefits of ideal (∼ 100%) mediation against both Gram-negative and Gram-positive bacteria. Whereas, non-degradable releases history is still a challenge and its longer accumulation may cause to disrupt biostructures and disease risk. Thus, facile development of large-area organic materials with switchable bacteria toxicity and normal cell compatibility function is interesting for concerned approaches. Here, smart positively-charged stable arginine amino acid incorporated mono layer graphene (Arg-EMGr) nanobiocomposite introduced as useful antibacterial and safe bactericidal agent competitive with Ag direct. The immunity characteristic versus Escherichia coli (E. coli) and Staphylococcus aureus (S. aureus) comparably assessed with graphene oxide (GO) and different concentrations GO-AgNPs morphology. As cell viability matter, 1,3,5,7-days vitro culture assay shown attachment proliferation and cytotoxicity due to short interaction.
  6. Amiri A, Baghayeri M, Karimabadi F, Ghaemi F, Maleki B
    Mikrochim Acta, 2020 03 10;187(4):213.
    PMID: 32157452 DOI: 10.1007/s00604-020-4193-z
    The stainless steel mesh, in the form of the disk, was coated with graphene oxide and poly(dimethylsiloxane) (GO-PDMS) by sol-gel technique. The coated stainless steel meshes are loaded in the mini-column as solid-phase extraction cartridge for the fast isolation and preconcentration of polycyclic aromatic hydrocarbons (PAHs) from real water samples. The extracted PAHs (naphthalene, acenaphthene, acenaphthylene, anthracene, benz[a]anthracene, fluorene, and pyrene) were quantified by gas chromatography-mass spectrometry. The operation parameters affecting the extraction efficiency including sample volume, desorption conditions, and ionic strength were investigated. At optimized conditions, the linearity of this method is obtained from 0.001 to 20 ng mL-1 with 0.2 to 1.0 pg mL-1 limit of detection. For 5 replicates at 3 spiking levels (0.1, 1, and 10 ng mL-1), the relative standard deviations between 4.0 and 6.3% were achieved. The absolute extraction recovery varied from 89.1 to 94.7%. The enrichment factors were in the range of 2227-2367. The method has been employed in the determination of PAHs in the real water samples including well water, tap water, river water, and wastewater. Relative recoveries are between 95.2 and 100.9%. Graphical abstractSchematic representation of the SPE procedure using the self-assembly SPE cartridge.
  7. Zare-Zardini H, Taheri-Kafrani A, Amiri A, Bordbar AK
    Sci Rep, 2018 01 12;8(1):586.
    PMID: 29330486 DOI: 10.1038/s41598-017-18938-y
    In this study, Rh2-treated graphene oxide (GO-Rh2), lysine-treated highly porous graphene (Gr-Lys), arginine-treated Gr (Gr-Arg), Rh2-treated Gr-Lys (Gr-Lys-Rh2) and Rh2-treated Gr-Arg (Gr-Arg-Rh2) were synthesized. MTT assay was used for evaluation of cytotoxicity of samples on ovarian cancer (OVCAR3), breast cancer (MDA-MB), Human melanoma (A375) and human mesenchymal stem cells (MSCs) cell lines. The percentage of apoptotic cells was determined by terminal deoxynucleotidyl transferase-mediated dUTP nick-end labeling (TUNEL) assay. The hemolysis and blood coagulation activity of nanostructures were performed. Interestingly, Gr-Arg, Gr-Lys, Gr-Arg-Rh2, and Gr-Lys-Rh2 were more active against cancer cell lines in comparison with their cytotoxic activity against normal cell lines (MSCs) with IC50 values higher than 100 μg/ml. The results of TUNEL assay indicates a significant increase in the rates of TUNEL positive cells by increasing the concentrations of nanomaterials. Results were also shown that aggregation and changes of RBCs morphology were occurred in the presence of GO, GO-Rh2, Gr-Arg, Gr-Lys, Gr-Arg-Rh2, and Gr-Lys-Rh2. Note that all the samples had effect on blood coagulation system, especially on PTT. All nanostrucure act as antitumor drug so that binding of drugs to a nostructures is irresolvable and the whole structure enter to the cell as a drug.
  8. Ghaemi F, Amiri A, Bajuri MY, Yuhana NY, Ferrara M
    Sustain Cities Soc, 2021 Sep;72:103046.
    PMID: 34055576 DOI: 10.1016/j.scs.2021.103046
    In 2019, a novel type of coronavirus emerged in China called SARS-COV-2, known COVID-19, threatens global health and possesses negative impact on people's quality of life, leading to an urgent need for its diagnosis and remedy. On the other hand, the presence of hazardous infectious waste led to the increase of the risk of transmitting the virus by individuals and by hospitals during the COVID-19 pandemic. Hence, in this review, we survey previous researches on nanomaterials that can be effective for guiding strategies to deal with the current COVID-19 pandemic and also decrease the hazardous infectious waste in the environment. We highlight the contribution of nanomaterials that possess potential to therapy, prevention, detect targeted virus proteins and also can be useful for large population screening, for the development of environmental sensors and filters. Besides, we investigate the possibilities of employing the nanomaterials in antiviral research and treatment development, examining the role of nanomaterials in antiviral- drug design, including the importance of nanomaterials in drug delivery and vaccination, and for the production of medical equipment. Nanomaterials-based technologies not only contribute to the ongoing SARS- CoV-2 research efforts but can also provide platforms and tools for the understanding, protection, detection and treatment of future viral diseases.
  9. Amiri A, Ahmadi G, Shanbedi M, Savari M, Kazi SN, Chew BT
    Sci Rep, 2015;5:17503.
    PMID: 26643279 DOI: 10.1038/srep17503
    Capacitive deionization (CDI) is a promising procedure for removing various charged ionic species from brackish water. The performance of graphene-based material in capacitive deionization is lower than the expectation of the industry, so highly-crumpled, few-layered graphene (HCG) and highly-crumpled nitrogen-doped graphene (HCNDG) with high surface area have been introduced as promising candidates for CDI electrodes. Thus, HCG and HCNDG were prepared by exfoliation of graphite in the presence of liquid-phase, microwave-assisted methods. An industrially-scalable, cost-effective, and simple approach was employed to synthesize HCG and HCNDG, resulting in few-layered graphene and nitrogen-doped graphene with large specific surface area. Then, HCG and HCNDG were utilized for manufacturing a new class of carbon nanostructure-based electrodes for use in large-scale CDI equipment. The electrosorption results indicated that both the HCG and HCNDG have fairly large specific surface areas, indicating their huge potential for capacitive deionization applications.
  10. Zare-Zardini H, Amiri A, Shanbedi M, Taheri-Kafrani A, Kazi SN, Chew BT, et al.
    J Biomed Mater Res A, 2015 Sep;103(9):2959-65.
    PMID: 25690431 DOI: 10.1002/jbm.a.35425
    One of the novel applications of the nanostructures is the modification and development of membranes for hemocompatibility of hemodialysis. The toxicity and hemocompatibility of Ag nanoparticles and arginine-treated multiwalled carbon nanotubes (MWNT-Arg) and possibility of their application in membrane technology are investigated here. MWNT-Arg is prepared by amidation reactions, followed by characterization by FTIR spectroscopy, Raman spectroscopy, and thermogravimetric analysis. The results showed a good hemocompatibility and the hemolytic rates in the presence of both MWNT-Arg and Ag nanoparticles. The hemolytic rate of Ag nanoparticles was lower than that of MWNT-Arg. In vivo study revealed that Ag nanoparticle and MWNT-Arg decreased Hematocrit and mean number of red blood cells (RBC) statistically at concentration of 100 µg mL(-1) . The mean decrease of RBC and Hematocrit for Ag nanoparticles (18% for Hematocrit and 5.8 × 1,000,000/µL) was more than MWNT-Arg (20% for Hematocrit and 6 × 1000000/µL). In addition, MWNT-Arg and Ag nanoparticles had a direct influence on the White Blood Cell (WBC) drop. Regarding both nanostructures, although the number of WBC increased in initial concentration, it decreased significantly at the concentration of 100 µg mL(-1) . It is worth mentioning that the toxicity of Ag nanoparticle on WBC was higher than that of MWNT-Arg. Because of potent antimicrobial activity and relative hemocompatibility, MWNT-Arg could be considered as a new candidate for biomedical applications in the future especially for hemodialysis membranes.
  11. Zubir MN, Badarudin A, Kazi SN, Misran M, Amiri A, Sadri R, et al.
    J Colloid Interface Sci, 2015 Sep 15;454:245-55.
    PMID: 26048724 DOI: 10.1016/j.jcis.2015.05.019
    The present work highlighted on the implementation of a unique concept for stabilizing colloids at their incipiently low charge potential. A highly charged nanoparticle was introduced within a coagulated prone colloidal system, serving as stabilizer to resist otherwise rapid flocculation and sedimentation process. A low size asymmetry of nanoparticle/colloid serves as the new topic of investigation in addition to the well-established large size ratio nanoparticle/microparticle study. Highly charged Al2O3 nanoparticles were used within the present research context to stabilize TiO2 and Fe3O4 based colloids via the formation of composite structures. It was believed, based on the experimental evidence, that Al2O3 nanoparticle interact with the weakly charged TiO2 and Fe3O4 colloids within the binary system via absorption and/or haloing modes to increase the overall charge potential of the respective colloids, thus preventing further surface contact via van der Waal's attraction. Series of experimental results strongly suggest the presence of weakly charged colloids in the studied bimodal system where, in the absence of highly charged nanoparticle, experience rapid instability. Absorbance measurement indicated that the colloidal stability drops in accordance to the highly charged nanoparticle sedimentation rate, suggesting the dominant influence of nanoparticles to attain a well-dispersed binary system. Further, it was found that the level of colloidal stability was enhanced with increasing nanoparticle fraction within the mixture. Rheological observation revealed that each hybrid complexes demonstrated behavior reminiscence to water with negligible increase in viscosity which serves as highly favorable condition particularly in thermal transport applications.
  12. Amiri A, Shanbedi M, Ahmadi G, Eshghi H, Kazi SN, Chew BT, et al.
    Sci Rep, 2016 09 08;6:32686.
    PMID: 27604639 DOI: 10.1038/srep32686
    This study reports on a facile and economical method for the scalable synthesis of few-layered graphene sheets by the microwave-assisted functionalization. Herein, single-layered and few-layered graphene sheets were produced by dispersion and exfoliation of functionalized graphite in ethylene glycol. Thermal treatment was used to prepare pure graphene without functional groups, and the pure graphene was labeled as thermally-treated graphene (T-GR). The morphological and statistical studies about the distribution of the number of layers showed that more than 90% of the flakes of T-GR had less than two layers and about 84% of T-GR were single-layered. The microwave-assisted exfoliation approach presents us with a possibility for a mass production of graphene at low cost and great potentials in energy storage applications of graphene-based materials. Owing to unique surface chemistry, the T-GR demonstrates an excellent energy storage performance, and the electrochemical capacitance is much higher than that of the other carbon-based nanostructures. The nanoscopic porous morphology of the T-GR-based electrodes made a significant contribution in increasing the BET surface as well as the specific capacitance of graphene. T-GR, with a capacitance of 354.1 Fg(-1) at 5 mVs(-1) and 264 Fg(-1) at 100 mVs(-1), exhibits excellent performance as a supercapacitor.
  13. Rafieerad AR, Bushroa AR, Nasiri-Tabrizi B, Kaboli SHA, Khanahmadi S, Amiri A, et al.
    J Mech Behav Biomed Mater, 2017 May;69:1-18.
    PMID: 28027481 DOI: 10.1016/j.jmbbm.2016.11.019
    Recently, the robust optimization and prediction models have been highly noticed in district of surface engineering and coating techniques to obtain the highest possible output values through least trial and error experiments. Besides, due to necessity of finding the optimum value of dependent variables, the multi-objective metaheuristic models have been proposed to optimize various processes. Herein, oriented mixed oxide nanotubular arrays were grown on Ti-6Al-7Nb (Ti67) implant using physical vapor deposition magnetron sputtering (PVDMS) designed by Taguchi and following electrochemical anodization. The obtained adhesion strength and hardness of Ti67/Nb were modeled by particle swarm optimization (PSO) to predict the outputs performance. According to developed models, multi-objective PSO (MOPSO) run aimed at finding PVDMS inputs to maximize current outputs simultaneously. The provided sputtering parameters were applied as validation experiment and resulted in higher adhesion strength and hardness of interfaced layer with Ti67. The as-deposited Nb layer before and after optimization were anodized in fluoride-base electrolyte for 300min. To crystallize the coatings, the anodically grown mixed oxide TiO2-Nb2O5-Al2O3 nanotubes were annealed at 440°C for 30min. From the FESEM observations, the optimized adhesive Nb interlayer led to further homogeneity of mixed nanotube arrays. As a result of this surface modification, the anodized sample after annealing showed the highest mechanical, tribological, corrosion resistant and in-vitro bioactivity properties, where a thick bone-like apatite layer was formed on the mixed oxide nanotubes surface within 10 days immersion in simulated body fluid (SBF) after applied MOPSO. The novel results of this study can be effective in optimizing a variety of the surface properties of the nanostructured implants.
  14. Zare-Zardini H, Amiri A, Shanbedi M, Taheri-Kafrani A, Sadri Z, Ghanizadeh F, et al.
    Iran J Ped Hematol Oncol, 2015;5(4):233-48.
    PMID: 26985357
    Despite development of new approaches for the treatment of cancer disease, it is the second cause of mortality in world. Annually, 30000 persons die in Iran due to cancer diseases. Eighty percent of cancer patients are children which about 50% children lead to death. Given the high rate of cancer-related death, the new approaches for prevention, control, early diagnosis, and treatment of this disease seem necessary. Investigation of new strategies is the major challenge for scientists at recent century. Nanotechnology as a new scientific field with novel and small compounds utilized different fields over the past ten years especially in medicine. This science has come to the forefront in the areas of medical diagnostics, imaging, and therapeutic scheduls. Therefore, it has the potential applications for cancer detection and therapy. This review will discuss the therapeutic applications of different nano-materials in diagnosis, imaging, and delivery of therapeutic agents for the treatment of cancer with a major focus on their applications for the treatment of cancer and cancer- related diseases in children. The advancements in established nanoparticle technologies such as liposomes, polymer micelles, and functionalization regarding tumor targeting and controlled release strategies as well as drug delivery were discussed. It will also review the blood toxicity of used nanostructures.