Displaying publications 1 - 20 of 24 in total

Abstract:
Sort:
  1. Ahamad NA, Kamangar S, Badruddin IA
    Biomed Mater Eng, 2018;29(3):319-332.
    PMID: 29578467 DOI: 10.3233/BME-181734
    The current study investigates the curvature effect due to various angles of curvature on the blood flow in human artery. The stenosis is considered to have three sizes 70%, 80% and 90% blockage before the curve section of artery. Numerical study of four different angle of curvature was considered to understand the flow behavior of artery having various curvatures, on the hemodynamics factors that includes drop in arterial pressure, flow velocity as well as wall shear stress. It was found that, the augmentation of the flow resistance due to the curvature increases in presence of stenosis. It was also noted that the wall shear is higher at the outer wall as compared to the inside wall in four models considered. Results showed that both the curvature of artery and size of the stenosis have significant impact. These two factors should be considered by cardiologist to assess the complexity of stenosis.
  2. Govindaraju K, Badruddin IA, Viswanathan GN, Ramesh SV, Badarudin A
    Phys Med, 2013 May;29(3):225-32.
    PMID: 22704601 DOI: 10.1016/j.ejmp.2012.03.008
    Coronary Artery Disease (CAD) is responsible for most of the deaths in patients with cardiovascular diseases. Diagnostic coronary angiography analysis offers an anatomical knowledge of the severity of the stenosis. The functional or physiological significance is more valuable than the anatomical significance of CAD. Clinicians assess the functional severity of the stenosis by resorting to an invasive measurement of the pressure drop and flow. Hemodynamic parameters, such as pressure wire assessment fractional flow reserve (FFR) or Doppler wire assessment coronary flow reserve (CFR) are well-proven techniques to evaluate the physiological significance of the coronary artery stenosis in the cardiac catheterization laboratory. Between the two techniques mentioned above, the FFR is seen as a very useful index. The presence of guide wire reduces the coronary flow which causes the underestimation of pressure drop across the stenosis which leads to dilemma for the clinicians in the assessment of moderate stenosis. In such condition, the fundamental fluid mechanics is useful in the development of new functional severity parameters such as pressure drop coefficient and lesion flow coefficient. Since the flow takes place in a narrowed artery, the blood behaves as a non-Newtonian fluid. Computational fluid dynamics (CFD) allows a complete coronary flow simulation to study the relationship between the pressure and flow. This paper aims at explaining (i) diagnostic modalities for the evaluation of the CAD and valuable insights regarding FFR in the evaluation of the functional severity of the CAD (ii) the role of fluid dynamics in measuring the severity of CAD.
  3. Kamangar S, Kalimuthu G, Badruddin IA, Badarudin A, Ahmed NJ, Khan TM
    ScientificWorldJournal, 2014;2014:354946.
    PMID: 25258722 DOI: 10.1155/2014/354946
    The present study deals with the functional severity of a coronary artery stenosis assessed by the fractional flow reserve (FFR). The effects of different geometrical shapes of lesion on the diagnostic parameters are unknown. In this study, 3D computational simulation of blood flow in three different geometrical shapes of stenosis (triangular, elliptical, and trapezium) is considered in steady and transient conditions for 70% (moderate), 80% (intermediate), and 90% (severe) area stenosis (AS). For a given percentage AS, the variation of diagnostic parameters which are derived from pressure drop across the stenosis was found in three different geometrical shapes of stenosis and it was observed that FFR is higher in triangular shape and lower in trapezium shape. The pressure drop coefficient (CDP) was higher in trapezium shape and lower in triangular model whereas the LFC shows opposite trend. From the clinical perspective, the relationship between percentage AS and FFR is linear and inversely related in all the three models. A cut-off value of 0.75 for FFR was observed at 76.5% AS in trapezium model, 79.5% in elliptical model, and 82.7% AS for the triangular shaped model. The misinterpretation of the functional severity of the stenosis is in the region of 76.5%-82.7 % AS from different shapes of stenosis models.
  4. Govindaraju K, Kamangar S, Badruddin IA, Viswanathan GN, Badarudin A, Salman Ahmed NJ
    Atherosclerosis, 2014 Apr;233(2):630-635.
    PMID: 24549189 DOI: 10.1016/j.atherosclerosis.2014.01.043
    Functional assessment of a coronary artery stenosis severity is generally assessed by fractional flow reserve (FFR), which is calculated from pressure measurements across the stenosis. The purpose of this study is to investigate the effect of porous media of the stenosed arterial wall on this diagnostic parameter. To understand the role of porous media on the diagnostic parameter FFR, a 3D computational simulations of the blood flow in rigid and porous stenotic artery wall models are carried out under steady state and transient conditions for three different percentage area stenoses (AS) corresponding to 70% (moderate), 80% (intermediate), and 90% (severe). Blood was modeled as a non Newtonian fluid. The variations of pressure drop across the stenosis and diagnostic parameter were studied in both models. The FFR decreased in proportion to the increase in the severity of the stenosis. The relationship between the percentage AS and the FFR was non linear and inversely related in both the models. The cut-off value of 0.75 for FFR was observed at 81.89% AS for the rigid artery model whereas 83.61% AS for the porous artery wall model. This study demonstrates that the porous media consideration on the stenotic arterial wall plays a substantial role in defining the cut-off value of FFR. We conclude that the effect of porous media on FFR, could lead to misinterpretation of the functional severity of the stenosis in the region of 81.89 %-83.61% AS.
  5. Govindaraju K, Viswanathan GN, Badruddin IA, Kamangar S, Salman Ahmed NJ, Al-Rashed AA
    Comput Methods Biomech Biomed Engin, 2016 Nov;19(14):1541-9.
    PMID: 27052093 DOI: 10.1080/10255842.2016.1170119
    This study aims to investigate the influence of artery wall curvature on the anatomical assessment of stenosis severity and to identify a region of misinterpretation in the assessment of per cent area stenosis (AS) for functionally significant stenosis using fractional flow reserve (FFR) as standard. Five artery models of different per cent AS severity (70, 75, 80, 85 and 90%) were considered. For each per cent AS severity, the angle of curvature of the arterial wall varied from straight to an increasingly curved model (0°, 30°, 60°, 90° and 120°). Computational fluid dynamics was performed under transient physiologic hyperemic flow conditions to investigate the influence of artery wall curvature on the pressure drop and the FFR. The findings in this study may be useful in in vitro anatomical assessment of functionally significant stenosis. The FFR decreased with increasing stenosis severity for a given curvature of the artery wall. Moreover, a significant decrease in FFR was found between straight and curved models discussed for a given severity condition. These findings indicate that the curvature effect was included in the FFR assessment in contrast to minimum lumen area (MLA) or per cent AS assessment. The MLA or per cent AS assessment may lead to underestimation of stenosis severity. From this numerical study, an uncertainty region could be evaluated using the clinical FFR cutoff value of 0.8. This value was observed at 81.98 and 79.10% AS for arteries with curvature angles of 0° and 120° respectively. In conclusion, the curvature of the artery should not be neglected in in vitro anatomical assessment.
  6. Mallick Z, Badruddin IA, Khaleed Hussain MT, Salman Ahmed NJ, Kanesan J
    Noise Health, 2009 Apr-Jun;11(43):98-102.
    PMID: 19414929 DOI: 10.4103/1463-1741.50694
    Over the last few years, interaction of humans with noisy power-driven agricultural tools and its possible adverse after effects have been realized. Grass-trimmer engine is the primary source of noise and the use of motorized cutter, spinning at high speed, is the secondary source of noise to which operators are exposed. In the present study, investigation was carried out to determine the effect of two types of grass-trimming machine engines (SUM 328 SE and BG 328) noise on the operators in real working environment. It was found that BG-328 and SUM-328 SE produced high levels of noise, of the order of 100 and 105 dB(A), respectively, to which operators are exposed while working. It was also observed that situation aggravates when a number of operators simultaneously operate resulting in still higher levels of noise. Operators should be separated 15 meters from each other in order to avoid the combined level of noise exposure while working with these machines. It was found that SPL, of the grass-trimmer machine engines (BG-328 and SUM-328 SE), were higher than the limit of noise recommended by ISO, NIOSH, and OSHA for an 8-hour workday. Such a high level of noise exposure may cause physiological and psychological problems to the operators in long run.
  7. Athani A, Ghazali NNN, Badruddin IA, Kamangar S, Anqi AE, Algahtani A
    Biomed Mater Eng, 2022;33(1):13-30.
    PMID: 34366314 DOI: 10.3233/BME-201171
    BACKGROUND: The blood flow in the human artery has been a subject of sincere interest due to its prime importance linked with human health. The hemodynamic study has revealed an essential aspect of blood flow that eventually proved to be paramount to make a correct decision to treat patients suffering from cardiac disease.

    OBJECTIVE: The current study aims to elucidate the two-way fluid-structure interaction (FSI) analysis of the blood flow and the effect of stenosis on hemodynamic parameters.

    METHODS: A patient-specific 3D model of the left coronary artery was constructed based on computed tomography (CT) images. The blood is assumed to be incompressible, homogenous, and behaves as Non-Newtonian, while the artery is considered as a nonlinear elastic, anisotropic, and incompressible material. Pulsatile flow conditions were applied at the boundary. Two-way coupled FSI modeling approach was used between fluid and solid domain. The hemodynamic parameters such as the pressure, velocity streamline, and wall shear stress were analyzed in the fluid domain and the solid domain deformation.

    RESULTS: The simulated results reveal that pressure drop exists in the vicinity of stenosis and a recirculation region after the stenosis. It was noted that stenosis leads to high wall stress. The results also demonstrate an overestimation of wall shear stress and velocity in the rigid wall CFD model compared to the FSI model.

  8. Kamangar S, Badruddin IA, Govindaraju K, Nik-Ghazali N, Badarudin A, Viswanathan GN, et al.
    Med Biol Eng Comput, 2017 Aug;55(8):1451-1461.
    PMID: 28004229 DOI: 10.1007/s11517-016-1604-8
    The purpose of this study is to investigate the effect of various degrees of percentage stenosis on hemodynamic parameters during the hyperemic flow condition. 3D patient-specific coronary artery models were generated based on the CT scan data using MIMICS-18. Numerical simulation was performed for normal and stenosed coronary artery models of 70, 80 and 90% AS (area stenosis). Pressure, velocity, wall shear stress and fractional flow reserve (FFR) were measured and compared with the normal coronary artery model during the cardiac cycle. The results show that, as the percentage AS increase, the pressure drop increases as compared with the normal coronary artery model. Considerable elevation of velocity was observed as the percentage AS increases. The results also demonstrate a recirculation zone immediate after the stenosis which could lead to further progression of stenosis in the flow-disturbed area. Highest wall shear stress was observed for 90% AS as compared to other models that could result in the rupture of coronary artery. The FFR of 90% AS is found to be considerably low.
  9. Kamangar S, Badruddin IA, Badarudin A, Nik-Ghazali N, Govindaraju K, Salman Ahmed NJ, et al.
    Comput Methods Biomech Biomed Engin, 2017 Mar;20(4):365-372.
    PMID: 27612619 DOI: 10.1080/10255842.2016.1233402
    The current study investigates the hyperemic flow effects on heamodynamics parameters such as velocity, wall shear stress in 3D coronary artery models with and without stenosis. The hyperemic flow is used to evaluate the functional significance of stenosis in the current era. Patients CT scan data of having healthy and coronary artery disease was chosen for the reconstruction of 3D coronary artery models. The diseased 3D models of coronary artery shows a narrowing of >50% lumen area. Computational fluid dynamics was performed to simulate the hyperemic flow condition. The results showed that the recirculation zone was observed immediate to the stenosis and highest wall shear stress was observed across the stenosis. The decrease in pressure was found downstream to the stenosis as compared to the coronary artery without stenosis. Our analysis provides an insight into the distribution of wall shear stress and pressure drop, thus improving our understanding of hyperemic flow effect under both conditions.
  10. Parveez B, Kittur MI, Badruddin IA, Kamangar S, Hussien M, Umarfarooq MA
    Polymers (Basel), 2022 Nov 18;14(22).
    PMID: 36433134 DOI: 10.3390/polym14225007
    Recent advances in aircraft materials and their manufacturing technologies have enabled progressive growth in innovative materials such as composites. Al-based, Mg-based, Ti-based alloys, ceramic-based, and polymer-based composites have been developed for the aerospace industry with outstanding properties. However, these materials still have some limitations such as insufficient mechanical properties, stress corrosion cracking, fretting wear, and corrosion. Subsequently, extensive studies have been conducted to develop aerospace materials that possess superior mechanical performance and are corrosion-resistant. Such materials can improve the performance as well as the life cycle cost. This review introduces the recent advancements in the development of composites for aircraft applications. Then it focuses on the studies conducted on composite materials developed for aircraft structures, followed by various fabrication techniques and then their applications in the aircraft industry. Finally, it summarizes the efforts made by the researchers so far and the challenges faced by them, followed by the future trends in aircraft materials.
  11. Samy PG, Kanesan J, Badruddin IA, Kamangar S, Ahammad NA
    Biomed Mater Eng, 2023 Dec 21.
    PMID: 38143334 DOI: 10.3233/BME-230149
    BACKGROUND: This study explores the dynamics of a mathematical model, utilizing ordinary differential equations (ODE), to depict the interplay between cancer cells and effector cells under chemotherapy. The stability of the equilibrium points in the model is analysed using the Jacobian matrix and eigenvalues. Additionally, bifurcation analysis is conducted to determine the optimal values for the control parameters.

    OBJECTIVE: To evaluate the performance of the model and control strategies, benchmarking simulations are performed using the PlatEMO platform.

    METHODS: The Pure Multi-objective Optimal Control Problem (PMOCP) and the Hybrid Multi-objective Optimal Control Problem (HMOCP) are two different forms of optimal control problems that are solved using revolutionary metaheuristic optimisation algorithms. The utilization of the Hypervolume (HV) performance indicator allows for the comparison of various metaheuristic optimization algorithms in their efficacy for solving the PMOCP and HMOCP.

    RESULTS: Results indicate that the MOPSO algorithm excels in solving the HMOCP, with M-MOPSO outperforming for PMOCP in HV analysis.

    CONCLUSION: Despite not directly addressing immediate clinical concerns, these findings indicates that the stability shifts at critical thresholds may impact treatment efficacy.

  12. Haowei Y, Mahyuddin N, Bin Nik Ghazali NN, Wang Z, Liu Y, Pan S, et al.
    PMID: 38385569 DOI: 10.1080/09603123.2024.2308731
    The Coronavirus Disease 2019 (COVID-19) has caused massive losses for the global economy. Scholars have used different methods to study the transmission mode and influencing factors of the virus to find effective methods to provide people with a healthy built environment. However, these studies arrived at different or even contradictory conclusions. This review presents the main research methodologies utilized in this field, summarizes the main investigation methods, and critically discusses their related conclusions. Data statistical analysis, sample collection, simulation models, and replication transmission scenarios are the main research methods. The summarized conclusion for prevention from all reviewed papers are: adequate ventilation and proper location of return air vents, proper use of personal protective equipment, as well as the reasonable and strict enforcement of policies are the main methods for reducing the transmission. Recommendations including standardized databases, causation clarification, rigorous experiment design, improved simulation accuracy and verification are provided.
  13. Hiba IH, Koh JK, Lai CW, Mousavi SM, Badruddin IA, Hussien M, et al.
    Heliyon, 2024 Apr 15;10(7):e28902.
    PMID: 38633652 DOI: 10.1016/j.heliyon.2024.e28902
    Rhodanine is a heterocyclic organic compound that has been investigated for its potential biomedical applications, particularly in drug discovery. Rhodanine derivatives have been examined as the medication options for numerous illnesses, including cancer, inflammation, and infectious diseases. Some rhodanine derivatives have also shown promising activity against drug-resistant strains of bacteria and viruses. One of these derivatives is polyrhodanine (PR), a conducting polymer that has gained attention for its biomedical properties. This review article summarises the latest advancements in creating biomaterials based on PR for biosensing, antimicrobial treatments, and anticancer therapies. The distinctive characteristics of PR, such as biocompatibility, biodegradability, and good conductivity, render it an attractive candidate for these applications. The article also explores obstacles and potential future paths for advancing biomaterials made with PR, including synthesis modifications, characterisation techniques, and in vivo evaluation of biocompatibility and efficacy. Overall, as an emerging research topic, this review emphasises the potential of PR as a promising biomaterial for various biomedical applications and provides insights into the contemporary state of research and prospective directions for investigation.
  14. Yusof Y, Moosavi S, Johan MR, Badruddin IA, Wahab YA, Hamizi NA, et al.
    ACS Omega, 2021 Feb 16;6(6):4184-4191.
    PMID: 33644542 DOI: 10.1021/acsomega.0c04864
    This study presents the electromagnetic (EM) characterization of a multiwalled carbon nanotubes (MWCNT)-silver nanoparticles (AgNP)-reinforced poly(vinyl alcohol) (PVA) hybrid nanocomposite fabricated via the solution mixing technique. Primarily, the structure and morphological properties of the PVA/MWCNT-AgNP hybrid nanocomposite are confirmed by X-ray diffraction (XRD) and field emission scanning electron microscopy (FESEM). The complex permittivity (ε*) and permeability (μ*), as well as the electromagnetic scattering parameters are measured using a PNA network analyzer equipped with X-band waveguide. The results showed an enhanced permittivity (ε' ≈ 25) value of the hybrid nanocomposite in the frequency range of 8-12 GHz. However, the permeability decreased to almost zero (μ' ≈ 0.4) since the inclusion of AgNP with an average particle size of 40 nm is not susceptible to magnetization and causes higher magnetic losses (tan δμ) than dielectric losses (tan δε). Remarkably, the hybrid nanocomposite reduced transmission of electromagnetic (EM) wave by nearly 60% in comparison to PVA/MWCNT. This is attributed to the enhanced absorption and reflection at the nanotubes, and metal-dielectric interfaces have induced multiple internal reflections owing to the porous structure of the nanocomposite. The prospect of the PVA/MWCNT-AgNP hybrid nanocomposite is favorable as a thin absorbing material for EM shielding applications.
  15. Faizal WM, Ghazali NNN, Khor CY, Badruddin IA, Zainon MZ, Yazid AA, et al.
    Comput Methods Programs Biomed, 2020 Nov;196:105627.
    PMID: 32629222 DOI: 10.1016/j.cmpb.2020.105627
    BACKGROUND AND OBJECTIVE: Human upper airway (HUA) has been widely investigated by many researchers covering various aspects, such as the effects of geometrical parameters on the pressure, velocity and airflow characteristics. Clinically significant obstruction can develop anywhere throughout the upper airway, leading to asphyxia and death; this is where recognition and treatment are essential and lifesaving. The availability of advanced computer, either hardware or software, and rapid development in numerical method have encouraged researchers to simulate the airflow characteristics and properties of HUA by using various patient conditions at different ranges of geometry and operating conditions. Computational fluid dynamics (CFD) has emerged as an efficient alternative tool to understand the airflow of HUA and in preparing patients to undergo surgery. The main objective of this article is to review the literature that deals with the CFD approach and modeling in analyzing HUA.

    METHODS: This review article discusses the experimental and computational methods in the study of HUA. The discussion includes computational fluid dynamics approach and steps involved in the modeling used to investigate the flow characteristics of HUA. From inception to May 2020, databases of PubMed, Embase, Scopus, the Cochrane Library, BioMed Central, and Web of Science have been utilized to conduct a thorough investigation of the literature. There had been no language restrictions in publication and study design of the database searches. A total of 117 articles relevant to the topic under investigation were thoroughly and critically reviewed to give a clear information about the subject. The article summarizes the review in the form of method of studying the HUA, CFD approach in HUA, and the application of CFD for predicting HUA obstacle, including the type of CFD commercial software are used in this research area.

    RESULTS: This review found that the human upper airway was well studied through the application of computational fluid dynamics, which had considerably enhanced the understanding of flow in HUA. In addition, it assisted in making strategic and reasonable decision regarding the adoption of treatment methods in clinical settings. The literature suggests that most studies were related to HUA simulation that considerably focused on the aspects of fluid dynamics. However, there is a literature gap in obtaining information on the effects of fluid-structure interaction (FSI). The application of FSI in HUA is still limited in the literature; as such, this could be a potential area for future researchers. Furthermore, majority of researchers present the findings of their work through the mechanism of airflow, such as that of velocity, pressure, and shear stress. This includes the use of Navier-Stokes equation via CFD to help visualize the actual mechanism of the airflow. The above-mentioned technique expresses the turbulent kinetic energy (TKE) in its result to demonstrate the real mechanism of the airflow. Apart from that, key result such as wall shear stress (WSS) can be revealed via turbulent kinetic energy (TKE) and turbulent energy dissipation (TED), where it can be suggestive of wall injury and collapsibility tissue to the HUA.

  16. Kamangar S, Badruddin IA, Ameer Ahamad N, Soudagar MEM, Govindaraju K, Nik-Ghazali N, et al.
    Biomed Mater Eng, 2017;28(3):257-266.
    PMID: 28527189 DOI: 10.3233/BME-171672
    The current study investigates the effect of multi stenosis on the hemodynamic parameters such as wall pressure, velocity and wall shear stress in the realistic left coronary artery. Patients CT scan image data of normal and diseased left coronary artery was chosen for the reconstruction of 3D coronary artery models. The diseased 3D model of left coronary artery shows a narrowing of more than 70% and 80% of area stenosis (AS) at the left main stem (LMS) and left circumflex (LCX) respectively. The results show that the decrease in pressure was found downstream to the stenosis as compared to the coronary artery without stenosis. The maximum pressure drop was noted across the 80% AS at the left circumflex branch. The recirculation zone was also observed immediate to the stenosis and highest wall shear stress was found across the 80% area stenosis. Our analysis provides an insight into the distribution of wall shear stress and pressure drop, thus improving our understanding on the hemodynamics in realistic coronary artery.
  17. Equbal A, Equbal MA, Equbal MI, Ravindrannair P, Khan ZA, Badruddin IA, et al.
    Materials (Basel), 2022 Nov 15;15(22).
    PMID: 36431537 DOI: 10.3390/ma15228051
    The present study investigates the CNC milling performance of the machining of AISI 316 stainless steel using a carbide cutting tool insert. Three critical machining parameters, namely cutting speed (v), feed rate (f) and depth of cut (d), each at three levels, are chosen as input machining parameters. The face-centred central composite design (FCCCD) of the experiment is based on response surface methodology (RSM), and machining performances are measured in terms of material removal rate (MRR) and surface roughness (SR). Analysis of variance, response graphs, and three-dimensional surface plots are used to analyse experimental results. Multi-response optimization using the data envelopment analysis based ranking (DEAR) approach is used to find the ideal configuration of the machining parameters for milling AISI 316 SS. The variables v = 220 m/min, f = 0.20 mm/rev and d = 1.2 mm were obtained as the optimal machine parameter setting. Study reveals that MRR is affected dominantly by d followed by v. For SR, f is the dominating factor followed by d. SR is found to be almost unaffected by v. Finally, it is important to state that this work made an attempt to successfully machine AISI 316 SS with a carbide cutting tool insert, to investigate the effect of important machining parameters on MRR and SR and also to optimize the multiple output response using DEAR method.
  18. Uppin VS, Gouda PSS, Kittur MI, Andriyana A, Ang BC, Parveez B, et al.
    Materials (Basel), 2022 Nov 30;15(23).
    PMID: 36500042 DOI: 10.3390/ma15238545
    Graphene-based fillers possess exceptional properties that encourage researchers toward their incorporation in glass-epoxy (GE) polymer composites. Regarding the mechanical and wear properties of glass-epoxy composites, the effect of graphene oxide (GO) reinforced in glass-epoxy was examined. A decrease in tensile modulus and increase in tensile strength was reported for 1 wt. % of GO. A shift in glass transition temperature Tg was observed with the addition of GO. The cross-link density and storage modulus of the composite decreased with the addition of GO. The decrease in dissipation energy and wear rate was reported with the increase in GO concentration. A simple one-dimensional damage model of nonlinear nature was developed to capture the stress-strain behavior of the unfilled and filled glass-epoxy composite. Tensile modulus E, Weibull scale parameter σo, and Weibull shape parameter β were considered to develop the model. Finally, to understand the failure mechanisms in GO-filled composites, a scanning electron microscopic (SEM) examination was carried out for tensile fractured composites.
  19. Tan PL, Kanesan J, Chuah JH, Badruddin IA, Abdellatif A, Kamangar S, et al.
    Biomed Mater Eng, 2023 Dec 28.
    PMID: 38189746 DOI: 10.3233/BME-230150
    BACKGROUND: The scientific revolution in the treatment of many illnesses has been significantly aided by stem cells. This paper presents an optimal control on a mathematical model of chemotherapy and stem cell therapy for cancer treatment.

    OBJECTIVE: To develop effective hybrid techniques that combine the optimal control theory (OCT) with the evolutionary algorithm and multi-objective swarm algorithm. The developed technique is aimed to reduce the number of cancerous cells while utilizing the minimum necessary chemotherapy medications and minimizing toxicity to protect patients' health.

    METHODS: Two hybrid techniques are proposed in this paper. Both techniques combined OCT with the evolutionary algorithm and multi-objective swarm algorithm which included MOEA/D, MOPSO, SPEA II and PESA II. This study evaluates the performance of two hybrid techniques in terms of reducing cancer cells and drug concentrations, as well as computational time consumption.

    RESULTS: In both techniques, MOEA/D emerges as the most effective algorithm due to its superior capability in minimizing tumour size and cancer drug concentration.

    CONCLUSION: This study highlights the importance of integrating OCT and evolutionary algorithms as a robust approach for optimizing cancer chemotherapy treatment.

  20. Faizal WM, Ghazali NNN, Badruddin IA, Zainon MZ, Yazid AA, Ali MAB, et al.
    Comput Methods Programs Biomed, 2019 Oct;180:105036.
    PMID: 31430594 DOI: 10.1016/j.cmpb.2019.105036
    Obstructive sleep apnea is one of the most common breathing disorders. Undiagnosed sleep apnea is a hidden health crisis to the patient and it could raise the risk of heart diseases, high blood pressure, depression and diabetes. The throat muscle (i.e., tongue and soft palate) relax narrows the airway and causes the blockage of the airway in breathing. To understand this phenomenon computational fluid dynamics method has emerged as a handy tool to conduct the modeling and analysis of airflow characteristics. The comprehensive fluid-structure interaction method provides the realistic visualization of the airflow and interaction with the throat muscle. Thus, this paper reviews the scientific work related to the fluid-structure interaction (FSI) for the evaluation of obstructive sleep apnea, using computational techniques. In total 102 articles were analyzed, each article was evaluated based on the elements related with fluid-structure interaction of sleep apnea via computational techniques. In this review, the significance of FSI for the evaluation of obstructive sleep apnea has been critically examined. Then the flow properties, boundary conditions and validation of the model are given due consideration to present a broad perspective of CFD being applied to study sleep apnea. Finally, the challenges of FSI simulation methods are also highlighted in this article.
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links