Displaying all 7 publications

Abstract:
Sort:
  1. Ibau C, Arshad MKM, Gopinath SCB, Nuzaihan M N M, Fathil MFM, Shamsuddin SA
    Int J Biol Macromol, 2020 Nov 01;162:1924-1936.
    PMID: 32822729 DOI: 10.1016/j.ijbiomac.2020.08.125
    This work explores Electrochemical Impedance Spectroscopy (EIS) detection for a highly-sensitive quantification of prostate-specific antigen (PSA) in Faradaic (f-EIS) and non-Faradaic modes (nf-EIS). Immobilization of monoclonal antibody specific to PSA (anti-PSA) was performed using 1-ethyl-3-dimethylaminopropylcarbodiimide hydrochloride and N-hydroxysuccinimide crosslinking agents in order to conjugate carboxylic (-COOH) terminated group of 16-Mercaptoundecanoic acid with amine (-NH3+) on anti-PSA epitope. This approach offers simple and efficient approach to form a strong, covalently bound thiol-gold (SAu) for a reliable SAM layer formation. Studies on the topographic of pristine Au-IDE surface were performed by Scanning Electron Microscopy and Energy Dispersive X-ray Spectroscopy techniques, meanwhile a 3-dimensional optical surface profiler, Atomic Force Microscopy and X-ray Photoelectron Spectroscopy techniques were used to validate the successful functionalization steps on the sensor transducer surface. Detection of PSA in f-EIS mode was carried out by measuring the response in charge transfer resistance (Rct) and impedance change (Z), meanwhile in nf-EIS mode, the changes in device capacitance was monitored. In f-EIS mode, the sensor reveals a logarithmic detection of PSA in a range of 100 ng/ml down to 0.01 ng/ml in Phosphate Buffered Saline with a recorded sensitivity of 2.412 kΩ/log10 ([PSA] ng/ml) and the limit of detection (LOD) down to 0.01 ng/ml. The nf-EIS detection mode yields a logarithmic detection range of 5000 ng/ml down to 0.5 ng/ml, with a sensitivity of 8.570 nF/log10 ([PSA] ng/ml) and an LOD of 0.5 ng/ml. The developed bio-assay yields great device stability, specificity to PSA and repeatability of detection that would pave its way for the future development into portable lab-on-chip bio-sensing system.
  2. Arshad MKM, Adzhri R, Fathil MFM, Gopinath SCB, N M NM
    J Nanosci Nanotechnol, 2018 Aug 01;18(8):5283-5291.
    PMID: 29458578 DOI: 10.1166/jnn.2018.15419
    The development of electrical biosensor towards device miniaturization in order to achieve better sensitivity with enhanced electrical signal has certain limitations especially complexity in fabrication process and costs. In this paper, an alternative technique with minor modification in the device structure is presented for signal amplification by implementing ambipolar conduction in the biosensor itself. We demonstrated the field-effect transistor (FET)-based biosensor coupled back-gate for attaining a higher sensitivity with the detection of lower target abundance. To utilize the coupled back-gate as a pre-amplifier, silicon-on-insulator wafer with thicknesses of top-silicon and buried oxide (BOX) layers of 70 nm and 145 nm, respectively were desired. Titanium dioxide (TiO2) nanomaterial was deposited using sol-gel method on the channel which acts as a transducer. Surface functionalization on TiO2 thin film allowed an effective immobilization of anti-cardiac troponin I antibody to interact cardiac troponin I (cTnI). Binding events at each step was validated by X-ray photoelectron spectroscopy (XPS) analysis. Further, electrical characterization (Id-Vd) confirms the potentiality of FET-based biosensor to detect cTnI (represents acute myocardial infarction disease) with the concentration ranges from 10 μg/ml down to 1 fg/ml. The sensitivity of 459.2 nA (g/ml)-1 and lower detection limit of 1 fg/ml were achieved at Vbg = -5 V and Vd = 5 V. The designed device demonstrates its ability to detect lower level of cTnI with pre-amplified electrical signal by back-gate biasing.
  3. Dalila R N, Md Arshad MK, Gopinath SCB, Norhaimi WMW, Fathil MFM
    Biosens Bioelectron, 2019 May 01;132:248-264.
    PMID: 30878725 DOI: 10.1016/j.bios.2019.03.005
    Two-dimensional (2D) layered nanomaterials have triggered an intensive interest due to the fascinating physiochemical properties with the exceptional physical, optical and electrical characteristics that transpired from the quantum size effect of their ultra-thin structure. Among the family of 2D nanomaterials, molybdenum disulfide (MoS2) features distinct characteristics related to the existence of direct energy bandgap, which significantly lowers the leakage current and surpasses other 2D materials. In this overview, we expatiate the novel strategies to synthesize MoS2 that cover techniques such as liquid exfoliation, chemical vapour deposition, mechanical exfoliation, hydrothermal reaction, and Van Der Waal epitaxial growth on the substrate. We extend the discussion on the recent progress in biosensing applications of the produced MoS2, highlighting the important surface-to-volume of ultrathin MoS2 structure, which enhances the overall performance of the devices. Further, envisioned the missing piece with the current MoS2-based biosensors towards developing the future strategies.
  4. Abd Rahman SF, Md Arshad MK, Gopinath SCB, Fathil MFM, Sarry F, Ibau C
    Chem Commun (Camb), 2021 Sep 23;57(76):9640-9655.
    PMID: 34473143 DOI: 10.1039/d1cc03080a
    Prostate cancer is currently diagnosed using the conventional gold standard methods using prostate-specific antigen (PSA) as the selective biomarker. However, lack of precision in PSA screening has resulted in needless biopsies and delays the treatment of potentially fatal prostate cancer. Thus, identification of glycans as novel biomarkers for the early detection of prostate cancer has attracted considerable attention due to their reliable diagnostic platform compared with the current PSA systems. Therefore, biosensing technologies that provide point-of-care diagnostics have demonstrated the ability to detect various analytes, including glycosylated micro- and macro-molecules, thereby enabling versatile detection methodologies. This highlight article discusses recent advances in the biosensor-based detection of prostate cancer glycan biomarkers and the innovative strategies for the conjugation of nanomaterials adapted to biosensing platforms. Finally, the article is concluded with prospects and challenges of prostate cancer biosensors and recommendations to overcome the issues associated with prostate cancer diagnosis.
  5. Dalila NR, Arshad MKM, Gopinath SCB, Nuzaihan MNM, Fathil MFM
    Mikrochim Acta, 2020 10 05;187(11):588.
    PMID: 33015730 DOI: 10.1007/s00604-020-04562-7
    Nanofabricated gold nanoparticles (Au-NPs) on MoS2 nanosheets (Au-NPs/MoS2) in back-gated field-effect transistor (BG-FET) are presented, which acts as an efficient semiconductor device for detecting a low concentration of C-reactive protein (C-RP). The decorated nanomaterials lead to an enhanced electron conduction layer on a 100-μm-sized transducing channel. The sensing surface was characterized by Raman spectroscopy, ultraviolet-visible spectroscopy (UV-Vis), atomic force microscopy (AFM), scanning electron microscopy (SEM), and high-power microscopy (HPM). The BG-FET device exhibits an excellent limit of detection of 8.38 fg/mL and a sensitivity of 176 nA/g·mL-1. The current study with Au-NPs/MoS2 BG-FET displays a new potential biosensing technology; especially for integration into complementary metal oxide (CMOS) technology for hand-held future device application.
  6. Taniselass S, Arshad MKM, Gopinath SCB, Fathil MFM, Ibau C, Anbu P
    Mikrochim Acta, 2021 07 15;188(8):257.
    PMID: 34268634 DOI: 10.1007/s00604-021-04922-x
    A label-free chemical bonding strategy mediated by reduced graphene oxide (rGO) basal plane functional groups has been developed for cardiac Troponin I (cTnI) detection. Four different chemical strategies on respective electrode sensing surface were precedingly examined using electrochemical impedance spectroscopy. The impedimetric assessment was carried out by sweeping frequency at the range 0.1-500 kHz perturbated at a small amplitude of AC voltage (25 mV). The chemical strategy-4 denoted as S-4 shows a significant analytical performance on cTnI detection in spiked buffer and human serum, whereby the pre-mixture of rGO and (3-Aminopropyl)triethoxysilane (APTES) creates a large number of amine sites (-NH2), which significantly enhanced the antibody immobilization without excessive functionalization. The as-fabricated immunosensor exhibited an ultra-low limit of detection of 6.3 ag mL-1 and the lowest antigen concentration measured was at 10 ag mL-1. The immunosensor showed a linear and wide range of cTnI detection (10 ag mL-1-100 ng mL-1) in human serum with a regression coefficient of 0.9716, rapid detection (5 min of binding time), and stable and highly reproducible bioelectrode response with RSD 
  7. Rahman SFA, Arshad MKM, Gopinath SCB, Fathil MFM, Sarry F, Ibau C, et al.
    Mikrochim Acta, 2024 Jan 31;191(2):118.
    PMID: 38296851 DOI: 10.1007/s00604-024-06189-4
    Highly specific detection of tumor-associated biomarkers remains a challenge in the diagnosis of prostate cancer. In this research, Maackia amurensis (MAA) was used as a recognition element in the functionalization of an electrochemical impedance-spectroscopy biosensor without a label to identify cancer-associated aberrant glycosylation prostate-specific antigen (PSA). The lectin was immobilized on gold-interdigitated microelectrodes. Furthermore, the biosensor's impedance response was used to assess the establishment of a complex binding between MAA and PSA-containing glycans. With a small sample volume, the functionalized interdigitated impedimetric-based (IIB) biosensor exhibited high sensitivity, rapid response, and repeatability. PSA glycoprotein detection was performed by measuring electron transfer resistance values within a concentration range 0.01-100 ng/mL, with a detection limit of 3.574 pg/mL. In this study, the ability of MAA to preferentially recognize α2,3-linked sialic acid in serum PSA was proven, suggesting a potential platform for the development of lectin-based, miniaturized, and cost effective IIB biosensors for future disease detection.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links