METHODS: Relevant articles written in English only, before January 15, 2017, were identified using an electronic search in the PubMed, Scopus, and Google Scholar databases. Furthermore, a manual search of the related major journals was also conducted to identify more pertinent articles. The relevancy of the articles was verified by screening the title, abstract, and full text if they met the inclusion criteria. A total of 37 articles satisfied the criteria, from which data were extracted for qualitative synthesis.
RESULTS: Among the 37 included articles, 14 were without aging, 15 were natural or artificial accelerated aging, 7 were outdoor weathering, and 1 contained both artificial aging and outdoor weathering. Only 4 studies out of the 14 without aging had significant observations; whereas 9 articles with natural or artificial aging published significant results, and 3 out of 7 outdoor weathering articles showed significant changes in the evaluated silicone elastomers.
CONCLUSIONS: Despite the varying research, it seems that the single "ideal" maxillofacial prosthetic material that can provide sufficient resistance against different aging conditions is yet to be identified. Therefore, it is imperative for standardization organizations, the scientific community, and academia to develop modified prosthetic silicones possessing improved physical properties and color stability, limiting the clinical problems regarding degradation of maxillofacial prostheses.
METHOD: Medical image data for five types of defects were selected, segmented, converted and decimated to 3D polygon models on a personal computer. The models were transferred to a computer aided design (CAD) software which aided in designing the prosthesis according to the virtual models. Two templates were designed for each defect, one by an OS (free) system and one by CS. The parameters for analyses were the virtual volume, Dice similarity coefficient (DSC) and Hausdorff's distance (HD) and were executed by the OS point cloud comparison tool.
RESULT: There was no significant difference (p > 0.05) between CS and OS when comparing the volume of the template outputs. While HD was within 0.05-4.33 mm, evaluation of the percentage similarity and spatial overlap following the DSC showed an average similarity of 67.7% between the two groups. The highest similarity was with orbito-facial prostheses (88.5%) and the lowest with facial plate prosthetics (28.7%).
CONCLUSION: Although CS and OS pipelines are capable of producing templates which are aesthetically and volumetrically similar, there are slight comparative discrepancies in the landmark position and spatial overlap. This is dependent on the software, associated commands and experienced decision-making. CAD-based templates can be planned on current personal computers following appropriate decimation.
OBJECTIVE: The present study aims to assess knowledge and awareness regarding needle stick and sharp injury among dental personnel and compared the knowledge and awareness level about needle stick injuries between dental professionals and dental supporting staff working at the School of Dental Sciences, Universiti Sains Malaysia.
METHODS: This cross-sectional study was conducted from March 2016 to March 2017. The total sample included 112 registered dental personnel including dental professionals (lecturers, dental officers, and postgraduate students) and dental supportive staff (including staff nurses and dental surgery assistant) who were selected from the School of Dental Sciences, Universiti Sains Malaysia at Kelantan District of Malaysia. Data were collected by a structured questionnaire.
RESULTS: In our study 60.7% respondents answered correctly for all the statements regarding knowledge and 51.8% of the respondents answered correctly for the statements regarding awareness on needle stick and sharp injury. No significant difference of knowledge level has been observed between the dental professionals and dental supportive staff (p
PURPOSE: The purpose of this in vitro study was to evaluate the SR, tensile strength (TS), and percentage elongation (% E) of different SEs subjected to outdoor weathering in the Malaysian climate.
MATERIAL AND METHODS: Type-II dumbbell-shaped specimens (N-120) (nonweathered=15, weathered=15) were made from 3 room-temperature vulcanized (A-2000, A-2006, and A-103) and 1 heat-temperature vulcanized (M-511) silicone (Factor II). For 6 months, weathered specimens were subjected to outdoor weathering inside a custom exposure rack. Simultaneously, the nonweathered specimens were kept in a dehumidifier. Subsequently, the SR was measured with a profilometer; TS and % E were measured by using a universal testing machine. Two-way ANOVA was used to compare the means of the tested properties of the nonweathered and weathered specimens, and pairwise comparison was carried out between the silicones (α=.05).
RESULTS: After outdoor weathering, the SR, TS, and % E were adversely affected by weathering in the Malaysian environment. Among the silicone materials, A-2000 showed the least TS changes (2.51 MPa), while A-2006 demonstrated significant changes in percentage elongation after outdoor weathering (266.5%). M-511 exhibited the highest mean value (2.50 μm) for SR changes. In addition, A-103 SE showed statistically significant differences in most pairwise comparisons for all 3 dependent variables.
CONCLUSIONS: Based on the evaluation of mechanical properties, A-103 can be suggested as a suitable silicone for maxillofacial prostheses fabricated for tropical climates. However, A-2000 can be a suitable alternative, although significant changes to surface roughness were detected after outdoor weathering.
PURPOSE: The purpose of this simulation study was to establish a reference percentage value that can be used to effectively reduce the size and polygons of the 3D mesh without drastically affecting the dimensions of the prosthesis itself.
MATERIAL AND METHODS: Fifteen different maxillary palatal defects were simulated on a dental cast and scanned to create 3D casts. Digital bulbs were fabricated from the casts. Conventional bulbs for the defects were fabricated, scanned, and compared with the digital bulb to serve as a control. The polygon parameters of digital bulbs were then reduced by different percentages (75%, 50%, 25%, 10%, 5%, and 1% of the original mesh) which created a total of 105 meshes across 7 mesh groups. The reduced mesh files were compared individually with the original design in an open-source point cloud comparison software program. The parameters of comparison used in this study were Hausdorff distance (HD), Dice similarity coefficient (DSC), and volume.
RESULTS: The reduction in file size was directly proportional to the amount of mesh reduction. There were minute yet insignificant differences in volume (P>.05) across all mesh groups, with significant differences (P
DESIGN: A digitally derived 3-dimensional maxillary model incorporating the palatal defect was generated from the patient's existing cone beam computerized tomography data and compared with the scanned cast from the conventional impression for linear dimensions, area, and volume. The digitally derived cast was 3-dimensionally printed and the obturator fabricated using traditional techniques. Similarly, an obturator was fabricated from the conventional cast and the fit of both final obturator bulbs were compared in vivo.
RESULTS: The digitally derived model produced more accurate volumes and surface areas within the defect. The defect margins and peripheries were overestimated which was reflected clinically.
CONCLUSION: The digitally derived model provided advantages in the fabrication of the palatal obturator; however, further clinical research is required to refine consistency.
MATERIALS AND METHODS: An auricular prosthesis, a complete denture, and anterior and posterior crowns were constructed using conventional methods and laser scanned to create computerized 3D meshes. The meshes were optimized independently by four computer-aided design software (Meshmixer, Meshlab, Blender, and SculptGL) to 100%, 90%, 75%, 50%, and 25% levels of original file size. Upon optimization, the following parameters were virtually evaluated and compared; mesh vertices, file size, mesh surface area (SA), mesh volume (V), interpoint discrepancies (geometric similarity based on virtual point overlapping), and spatial similarity (volumetric similarity based on shape overlapping). The influence of software and optimization on surface area and volume of each prosthesis was evaluated independently using multiple linear regression.
RESULTS: There were clear observable differences in vertices, file size, surface area, and volume. The choice of software significantly influenced the overall virtual parameters of auricular prosthesis [SA: F(4,15) = 12.93, R2 = 0.67, p < 0.001. V: F(4,15) = 9.33, R2 = 0.64, p < 0.001] and complete denture [SA: F(4,15) = 10.81, R2 = 0.67, p < 0.001. V: F(4,15) = 3.50, R2 = 0.34, p = 0.030] across optimization levels. Interpoint discrepancies were however limited to <0.1mm and volumetric similarity was >97%.
CONCLUSION: Open-source mesh optimization of smaller dental prostheses in this study produced minimal loss of geometric and volumetric details. SculptGL models were most influenced by the amount of optimization performed.
CASE DESCRIPTION: The first case, a man in his twenties, received a stock conformer immediately after surgery and started prosthetic therapy within 2 months. The second case, a man in his forties, started prosthetic therapy after 10 years. Definitive custom ocular prostheses were fabricated and relined according to conventional protocol.
RESULTS: On issue of the prosthesis, there was adequate retention, aesthetics and stability to extra-ocular movements and treatment was considered successful for both cases. However, follow-ups showed noticeable prosthetic eye movements for case 1 which, to some extent mimicked the physiologic movement of its fellow natural eye. Case 1 adjusted to his prosthesis better while case 2 was still adjusting with little to no physiologic movement.
CONCLUSION: Prosthetic rehabilitation should be started as early as possible to obtain optimum rehabilitative results.
PURPOSE: The purpose of this systematic review was to investigate the quality and outcome of studies into maxillary anterior tooth proportion and to determine whether dental proportion ratios based on different geographic regions are appropriate.
MATERIAL AND METHODS: An electronic search was conducted using PubMed, MEDLINE, Google Scholar, Embase, Scopus, Cochrane Library, Web of Science, and Science Direct databases. English-language articles reporting with the specific combination of medical subject heading (MeSH) key words were analyzed by 2 investigators. The titles, full text, and abstracts were scanned by investigators independently to identify articles that fulfilled the inclusion criteria. The general characteristics, outcomes, and quality of each study were reviewed and analyzed systematically.
RESULTS: The search plan resulted in a total of 73 articles until September 2020; of which, 16 articles fulfilling the inclusion criteria were selected. The geographic distribution of the selected article revealed 12 articles from Asia, 2 from Continental Europe, and 2 from the United Kingdom. Golden percentage values of 25%, 15%, and 10% for central, lateral incisor, and canine teeth were not found. The mean predicted dental percentage was either larger or smaller than the successive widths of maxillary natural anterior teeth.
CONCLUSIONS: The golden percentage could not be used to formulate a smile design. Rather, the dental ratios should be set on a racial and ethnic basis for a population.
Materials and methods: This is a retrospective study. 800 CBCT scan obtained for the measurement of condyle in anterior-posterior and medio-lateral aspect using OnDemand 3D software. Participants were Saudi nationals of age above 18 years. 395 Males and 405 Females with the mean age of 38.2 ± 10.5 years. Right and left anterior-posterior width and medio-lateral width of the condyle were measured. Condyles were not isolated on the CBCT for volume measurement.
Results: Mean right and anterior-posterior condyle width was 9.02 mm and 8.74 mm in males whereas in females it was 9.01 mm 8.69 mm respectively. For males mean medio-lateral width of the condyle in right and left side was 17.40 mm and 16.95 mm. For females, mean medio-lateral width of the condyle in right and left side was 17.14 mm and 16.93 mm. The prediction rate of gender was 57.2% for males and 53.3% for females. Statistically significant differences (p