  1. Alkhorayef M, Sulieman A, Alzahrani K, Abuzaid M, Alomair OI, Almuwannis M, et al.
    Appl Radiat Isot, 2021 Feb;168:109520.
    PMID: 33307438 DOI: 10.1016/j.apradiso.2020.109520
    The various technological advancements in computed tomography (CT) have resulted in remarkable growth in the use of CT imaging in clinical practice, not the least of which has been its establishment as the most valuable imaging examination for the assessment of cardiovascular system disorders. The objective of this study was to assess the effective radiation dose and radiation risk for patients during cardiac CT procedures, based on studies from four different hospitals equipped with 128 slice CT equipment. A total of eighty-three patients were investigated in this study with different clinical indications. Effective doses were also calculated using software based on Monte Carlo simulation. The mean patient age (years), weight (kg), and body mass index (BMI (kg/m2)) were 49 ± 11, 82 ± 12, and 31 ± 6, respectively. The results of the study revealed that the tube voltage (kVp) and tube current-exposure time product (mAs) ranged between 100 to 140 and 50 to 840 respectively. The overall average patient dose values for the volume CT dose index [(CTDIvol), in mGy)] and dose length product (DLP) (in mGy·cm) were 34.8 ± 15 (3.7-117.0) and 383.8 ± 354 (46.0-3277.0) respectively. The average effective dose (mSv) was 15.2 ± 8 (1.2-61.8). The radiation dose values showed wide variation between different hospitals and even within the same hospital. The results indicate the need to optimize radiation dose and to establish diagnostic reference levels (DRLs) for patients undergoing coronary computed tomography angiography (CCTA), also to harmonize the imaging protocols to ensure reduced radiation risk.
  2. Tamam N, Almuqrin AH, Mansour S, Elnour A, Musa M, Omer H, et al.
    Appl Radiat Isot, 2021 Nov;177:109899.
    PMID: 34438276 DOI: 10.1016/j.apradiso.2021.109899
    Ionizing radiation exposure from medical applications is increasing annually worldwide. It was estimated that 325 million dental procedures were performed in the United States. Radiation exposure from dental radiography consists of intraoral, panoramic, and 3D imaging cone-beam computed tomography (CBCT) imaging. Recent studies reported an association between dental imaging procedures and increased cancer probability of brain and thyroid. Previous studies showed that some dental imaging practices exposed patients and staff to unnecessary radiation doses due to incorrect image acquisition and insufficient radiation protection measures. This study aims to (i) measure the occupational and patients doses during dental procedures and (ii) assess the current imaging techniques and radiation protection practices. Two hundred fourteen patients were evaluated for periapical, bitewing, cephalometric, occlusal, and panoramic procedures. Organ equivalent doses were quantified for the breast, eye lens, and thyroid gland during CBCT procedure. Occupational and ambient dose assessment were assessed using calibrated thermoluminescent dosimeters (TLD-100(LiF: Mg. Ti). Ambient doses were measure at different locations at the department using TLDs. Patients' radiation doses were quantified using kerma area product (PKA (mGy.cm) and the entrance surface air kerma (ESAK (mGy). Fixed tube voltage (65 kVp) and tube current-time product (7 mAs) were used. The overall mean, sd, and range of patients dose values during intraoral (mGy), panoramic and CBCT examinations were 4.6 ± 0.7 (1.4-7.1), 135 ± 45 (75.2-168.5), and 215 ± 165 (186-2115), respectively. The mean and range of the annual occupational doses (mSv) were 1.4 (0.6-3.7), which below the annual dose limits for radiation workers (20 mSv/y). The study showed that inadequate radiation protection for patients existed in terms of the use of the thyroid shield, the technologist's presence inside the room during radiation exposure. Patients' radiation doses were comparable with the international diagnostic reference level (DRL). Staff education and training in radiation protection aspects are highly recommended.
  3. Salah H, Tamam N, Rabbaa M, Abuljoud M, Zailae A, Alkhorayef, et al.
    Appl Radiat Isot, 2023 Feb;192:110548.
    PMID: 36527854 DOI: 10.1016/j.apradiso.2022.110548
    Computed tomography coronary angiography (CTCA) has generated tremendous interest over the past 20 years by using multidetector computed tomography (MDCT) because of its high diagnostic accuracy and efficacy in assessing patients with coronary artery disease. This technique is related to high radiation doses, which has raised serious concerns in the literature. Effective dose (E, mSv) may be a single parameter meant to reflect the relative risk from radiation exposure. Therefore, it is necessary to calculate this quantity to point to relative radiation risk. The objectives of this study are to evaluate patients' exposure during diagnostic CCTA procedures and to estimate the risks. Seven hundred ninety patients were estimated during three successive years. The patient's exposure was estimated based on a CT device's delivered radiation dose (Siemens Somatom Sensation 64 (64-MDCT)). The participating physicians obtained the parameters relevant to the radiation dose from the scan protocol generated by the CT system after each CCTA study. The parameters included the volume CT dose index (CTDIvol, mGy) and dose length product (DLP, mGy × cm). The mean and range of CTDIvol (mGy) and DLP (mGy × cm) for three respective year was (2018):10.8 (1.14-77.7) and 2369.8 ± 1231.4 (290.4-6188.9), (2019): 13.82 (1.13-348.5), and 2180.5 (501.8-9534.5) and (2020) 10.9 (0.7-52.9) and 1877.3 (149.4-5011.1), respectively. Patients' effective doses were higher compared to previous studies. Therefore, the CT acquisition parameter optimization is vital to reduce the dose to its minimal value.
  4. Salah H, Rabbaa M, Abuljoud M, Babikir E, Alkhorayef M, Tamam N, et al.
    Appl Radiat Isot, 2023 Feb;192:110610.
    PMID: 36525913 DOI: 10.1016/j.apradiso.2022.110610
    In comparison to adults and paediatric are more sensitive to ionizing radiation exposure. Computed tomography (CT) is now the dominant source of medical radiologic tests for patients, accounting for more than 70% of total doses to the general public. Paediatric CT brain scans (with and without contrast) are routinely performed for a variety of clinical reasons. As a result, this parameter must be calculated in order to determine relative radiation risk. The goal of this study is to assess the radiation risk to children during CT brain diagnostic procedures. Three hundred fifty three child patients' radiation risk doses were assessed over the course of a year. The mean and ranged of the children's radiation doses were 40.6 ± 8.8 (27.8-45.8) CTDIvol (mGy) and 850 ± 230 (568.1-1126.4) DLP (mGy.cm) for the brain with contrast medium. For CT brain without contrast, the patients' doses were 40.9 ± 9.4 (14.27-64.07) CTDIvol (mGy), and 866.1 ± 289.3 (203.6-2484.9) DLP (mGy.cm). The characteristics related to the radiation dose were retrieved from the scan protocol generated by the CT system by the participating physicians after each procedure. Furthermore, optimizing the CT acquisition parameter is critical for increasing the benefit while lowering the procedure's radiogenic risk. The patients' radiation dose is comparable with the most previously published studies and international diagnostic reference levels (DRLs). Radiation dose optimization is recommended due to high sensitivity of the paediatric patients to ionizing radiation.
  5. Sulieman A, Salah H, Rabbaa M, Abuljoud M, Alkhorayef M, Tahir D, et al.
    Appl Radiat Isot, 2023 Mar;193:110626.
    PMID: 36640699 DOI: 10.1016/j.apradiso.2022.110626
    Breast cancer is a common malignancy for females (25% of female cancers) and also has low incidence in males. It was estimated that 1% of all breast malignancies occur in males with mortality rate about 20%, with annual increase in incidence. Risk factors include age, family history, exposure to ionizing radiation and high estrogen and low of androgens hormones level. Diagnosis and screening are challenging due to limiting effectiveness of breast cancer screening. Therefore, patients may expose to ionizing radiation that may contribute in breast cancer incidence in males. In literature, limited studies were published regarding radiation exposure for males during mammography. The objective of this research is to quantify patient doses during male mammogram and to estimate the projected radiogenic risk during the procedure. In total, 42 male patients were undergone mammogram for breast cancer diagnosis during two consecutive years. The mean and range of patient age (years) is 45 (23-80). The mean and standard deviation (SD) of the peak tube potential and tube current time product are 28.64 ± 2. and 149 ± 35.1, respectively. The mean, and range of patients' entrance surface air kerma (ESAK, mGy) per single breast procedure was 5.3 (0.47-27.5). Male patient's received comparable radiation dose per mammogram compared to female procedures. With increasing incidence of male breast cancer, proper guidelines are necessary for the mammographic procedure are necessary to reduce unnecessary radiation doses and radiogenic risk.
  6. Bushra A, Sulieman A, Edam A, Tamam N, Babikir E, Alrihaima N, et al.
    Appl Radiat Isot, 2023 Mar;193:110627.
    PMID: 36584412 DOI: 10.1016/j.apradiso.2022.110627
    Computed tomography is widely used for planar imaging. Previous studies showed that CR systems involve higher patient radiation doses compared to digital systems. Therefore, assessing the patient's dose and CR system performance is necessary to ensure that patients received minimal dose with the highest possible image quality. The study was performed at three medical diagnostic centers in Sudan: Medical Corps Hospital (MCH), Advance Diagnostic Center (ADC), and Advance Medical Center (AMC). The following tools were used in this study: Tape measure, Adhesive tape, 1.5 mm copper filtration (>10 × 10 cm), TO 20 threshold contrast test object, Resolution test object (e.g., Huttner 18), MI geometry test object or lead ruler, Contact mish, Piranha (semiconductor detector), Small lead or copper block (∼5 × 5 cm), and Steel ruler, to do a different type of tests (Dark Noise, Erasure cycle efficiency, Sensitivity Index calibration, Sensitivity Index consistency, Uniformity, Scaling errors, Blurring, Limiting spatial Resolution, Threshold, and Laser beam Function. Entrance surface air kerma (ESAK (mGy) was calculated from patient exposure parameters using DosCal software for three imaging modalities. A total of 199 patients were examined (112 chest X rays, 77 lumbar spine). The mean and standard deviation (sd) for patients ESAK (mGy) were 2.56 ± 0.1 mGy and 1.6 mGy for the Anteroposterior (AP) and lateral projections for the lumbar spine, respectively. The mean and sd for the patient's chest doses were 0.1 ± 0.01 for the chest X-ray procedures. The three medical diagnostic centers' CR system performance was evaluated and found that all of the three centers have good CR system functions. All the centers satisfy all the criteria of acceptable visual tests. CR's image quality and sensitivity were evaluated, and the CR image is good because it has good contrast and resolution. All the CR system available in the medical centers and upgraded from old X-ray systems to new systems, has been found to work well. The patient's doses were comparable for the chest X-ray procedures, while patients' doses from the lumbar spine showed variation up to 2 folds due to the variation in patients' weight and X-ray machine setting. Patients dose optimization is recommended to ensure the patients received a minimal dose while obtaining the diagnostic findings.
  7. Sulieman A, Mahgoub O, Salah H, Tamam N, Taha A, Dawood S, et al.
    Appl Radiat Isot, 2023 Dec;202:111071.
    PMID: 37871398 DOI: 10.1016/j.apradiso.2023.111071
    Due to the extended localized fluoroscopy, many radiographic exposures, and multiple procedures that might result in tissue reaction, patients and personnel received a significant radiation dose during interventional cardiology (IR) procedures. This study aims to calculate the radiation risk and assess patient and staff effective doses during IC procedures. Thirty-two patients underwent a Cath lab treatment in total. Ten Cath lab personnel, including six nurses, two cardiologists, and two X-ray technologists. Optical stimulating-luminescent dosimeters (OSL) (Al2O3:C) calibrated for this purpose were used to monitor both occupational and ambient doses. Using an automated OSL reader, these badges were scanned. The Air Kerma (mGy) and Kerma Area Products (KAP, mGy.cm2) have a mean and standard deviation (SD) of 371 ± 132 and 26052, respectively. The average personal dose equivalent (mSv) and its range for cardiologists, nurses and X ray technologists were 1.11 ± 0.21 (0.96-1.26), 0.84 ± 0.11 (0.68-1.16), and 0.68 ± 0.014 (0.12-0.13), respectively. The current study findings showed that the annual effective dose for cardiologists, nurses, and X-ray technologists was lesser than the yearly occupational dose limit of 20 mSv recommended by national and international guidelines. The patients' doses are comparable with some previously published studies and below the tissue reaction limits.
  8. Tamam N, Sulieman A, Omer H, Toufig H, Alsaadi M, Salah H, et al.
    Appl Radiat Isot, 2022 Dec;190:110452.
    PMID: 36183658 DOI: 10.1016/j.apradiso.2022.110452
    CT scanning deliver much higher radiation doses than planar radiological procedures, which puts patients to high risks. This study measures and evaluates patient doses during chest and abdomen computed tomography procedures. Particular attention is given to measuring the dose to the equivalent breast (mSv) and to estimate the associated risks of breast cancer to young female patients (15-35 years). Data was obtained from standard examinations from three hospitals. The measured values of CT dose indexes, CTDI (mGy) as well as exposure-related parameters were used for assessment. Breast and effective doses were extrapolated using a software. The results showed remarkable variations of the mean organ equivalent doses for similar CT examinations in the studied hospitals. This could be attributed to the variation in CT scanning imaging technique, and clinical indications. The average effective dose to the chest was 7.9 mSv (2.3-47.0 mSv) and for the abdomen the mean dose was 6.6 mSv, ranging from (3.3-27 mSv). The breast received equivalent doses from chest and abdomen procedures as follows: 10.2 (1.6-33 mSv) and 10.1(2.3-19 mS) Sv respectively. Each procedure yielded high risks of breast cancer for young females. Implementation of accurate referral criteria is recommended to avoid unnecessary breast radiation exposure.
  9. Aamry A, Sulieman A, Tamam N, Abuhadi NH, Johary Y, Aamri H, et al.
    Appl Radiat Isot, 2022 Mar;181:110097.
    PMID: 35063867 DOI: 10.1016/j.apradiso.2022.110097
    Staff occupational radiation exposure is limited to 20 mSv annually to preclude tissue reaction and lower risk of cancer effect. Staff occupational exposure arises during the preparation, injection, and scanning of the patients. Recent studies reported that nuclear medicine personnel might exceed the annual dose limit in high workload and poor radiation protection circumstances. Therefore, an accurate estimation of the annual dose limit is recommended. The goal of this research is to calculate the cumulative external effective dose (mSv) per year for nuclear medicine physicians, technologists, and nurses at SPECT/CT department. A total of 15 staff worked in the nuclear medicine department at King Saud Medical City (KSMC), Riyadh, Saudi Arabia were evaluated for the last six years. 99mTc is used more frequently for most of the patients. The procedures include renal, cardiac scintigraphy procedures. Staff dose was quantified using calibrated thermoluminecnt dosimeters (TLD-100) with an automatic TLD reader (Harshaw 6600). Exposure to ionizing radiation was evaluated in terms of deep doses (Hp(10) were evaluated. The overall average and standard deviation of the external doses for nuclear medicine physicians, technologists' and nurses were 1.8 ± 0.7, 1.9 ± 0.6, 2.0 ± 0.9, 2.2 ± 0.8, 6.0 ± 2.8, and 3.6 ± 1.3 for the years 2015,2016,2017,2018,2019, and 2020, respectively. Technologists and nurses received higher doses of compared to the nuclear medicine physicians. Technologists and nurses involved in radionuclide preparation, patients' injection, and image acquisition. Staff annual exposure is below the annual dose limits; however, this external dose is considered high compared to the current workload.
  10. Johary YH, Albarakati S, AlSohaim A, Aamry A, Aamri H, Tamam N, et al.
    Appl Radiat Isot, 2023 Mar;193:110648.
    PMID: 36669265 DOI: 10.1016/j.apradiso.2023.110648
    Occupational radiation exposure can occur due to various human activities, including the use of radiation in medicine. Occupationally exposed personnel surpassing 7.4 millions, and respresent the biggest single group of employees who are exposed to artificial radiation sources at work. This study compares the occupational radiation dose levels for 145 workers in four different hospitals located in the Aseer region in Saudi Arabia. The occupational exposure was quantified using thermoluminescence dosimeters (TLD-100). The levels of annual occupational exposures in targeted hospitals were calculated and compared with the levels of the international atomic energy agency (IAEA) Safety Standards. An average yearly cumulative dose for the two consecutive years. The average, highest and lowest resulted occupational doses under examination in this work is 1.42, 3.9 mSv and 0.72 for workers in various diagnostic radiology procedures. The resulted annual effective dose were within the IAEA approved yearly dose limit for occupational exposure of workers over 18, which is 20 mSv. Staff should be monitored on a regular basis, according to current practice, because their annual exposure may surpass 15% of the annual effective doses.
  11. Iftikhar B, Alih SC, Vafaei M, Javed MF, Rehman MF, Abdullaev SS, et al.
    Sci Rep, 2023 Jul 27;13(1):12149.
    PMID: 37500697 DOI: 10.1038/s41598-023-39349-2
    Plastic sand paver blocks provide a sustainable alternative by using plastic waste and reducing the need for cement. This innovative approach leads to a more sustainable construction sector by promoting environmental preservation. No model or Equation has been devised that can predict the compressive strength of these blocks. This study utilized gene expression programming (GEP) and multi-expression programming (MEP) to develop empirical models to forecast the compressive strength of plastic sand paver blocks (PSPB) comprised of plastic, sand, and fibre in an effort to advance the field. The database contains 135 results for compressive strength with seven input parameters. The R2 values of 0.87 for GEP and 0.91 for MEP for compressive strength reveal a relatively significant relationship between predicted and actual values. MEP outperformed GEP by displaying a higher R2 and lower values for statistical evaluations. In addition, a sensitivity analysis was conducted, which revealed that the sand grain size and percentage of fibres play an essential part in compressive strength. It was estimated that they contributed almost 50% of the total. The outcomes of this research have the potential to promote the reuse of PSPB in the building of green environments, hence boosting environmental protection and economic advantage.
  12. Al Mahmud J, Siraz MMM, Alam MS, Dewan MJ, Rashid MB, Khandaker MU, et al.
    Mar Pollut Bull, 2024 Apr 10;202:116349.
    PMID: 38604081 DOI: 10.1016/j.marpolbul.2024.116349
    Coastal Mangroves are facing growing threats due to the harmful consequences of human activities. This first-ever detailed study of natural radioactivity in soil samples collected from seven tourist destinations within the Sundarbans, the world's largest mangrove forest, was conducted using HPGe gamma-ray spectrometry. Although the activity levels of 226Ra (11 ± 1-44 ± 4 Bq/kg) and 232Th (13 ± 1-68 ± 6 Bq/kg) generally align with global averages, the concentration of 40K (250 ± 20-630 ± 55 Bq/kg) was observed to surpass the worldwide average primarily due to factors like salinity intrusion, fertilizer application, agricultural runoff, which suggests the potential existence of potassium-rich mineral resources near the study sites. The assessment of the hazard parameters indicates that the majority of these parameters are within the recommended limits. The soil samples do not pose a significant radiological risk to the nearby population. The results of this study can establish important radiological baseline data before the Rooppur Nuclear Power Plant begins operating in Bangladesh.
  13. Alnaaimi M, Sulieman A, Tamam N, Alkhorayef M, Alduaij M, Mohammedzein T, et al.
    Appl Radiat Isot, 2021 Dec;178:109965.
    PMID: 34688024 DOI: 10.1016/j.apradiso.2021.109965
    The positron emitters (18F-Sodium Fluoride (NaF)) and X-rays used in Positron emission tomography (PET) combined with computed tomography (PET/CT) imaging have a high radiation dose, which results in a high patient dose. The present research intends to determine the radiation dose and risks associated with PET/CT- 18F-Sodium fluoride examinations in patients. The 18F-NaF PET/CT was used to investigate the doses of 86 patients. Patient exposure parameters and ImPACT software were used to calculate mean effective doses. The administered activity of 185 MBq (5.0 mCi) per procedure has a mean and range based on the patient's BMI (BMI). The range of patient effective doses per procedure was found to be 4-10 mSv, with a radiation risk of 1 × 10-5 per procedure. Patient doses are determined by the patient's size, scanner type, imaging protocol, and reconstruction method. For further dose reduction, proper justification and radiation dose optimization is required.
  14. Bose R, Jayawant M, Raut R, Lakkakula J, Roy A, Alghamdi S, et al.
    Front Pharmacol, 2023;14:1218867.
    PMID: 37601050 DOI: 10.3389/fphar.2023.1218867
    The field of cancer nanotheranostics is rapidly evolving, with cyclodextrin (CD)-based nanoparticles emerging as a promising tool. CDs, serving as nanocarriers, have higher adaptability and demonstrate immense potential in delivering powerful anti-cancer drugs, leading to promising and specific therapeutic outcomes for combating various types of cancer. The unique characteristics of CDs, combined with innovative nanocomplex creation techniques such as encapsulation, enable the development of potential theranostic treatments. The review here focuses mainly on the different techniques administered for effective nanotheranostics applications of CD-associated complex compounds in the domain of cancer treatments. The experimentations on various loaded drugs and their complex conjugates with CDs prove effective in in vivo results. Various cancers can have potential nanotheranostics cures using CDs as nanoparticles along with a highly efficient process of nanocomplex development and a drug delivery system. In conclusion, nanotheranostics holds immense potential for targeted drug delivery and improved therapeutic outcomes, offering a promising avenue for revolutionizing cancer treatments through continuous research and innovative approaches.
  15. Isinkaye MO, OlaOlorun OA, Chandrasekaran A, Adekeye AS, Dada TE, Tamilarasi A, et al.
    Heliyon, 2023 Nov;9(11):e22451.
    PMID: 38034673 DOI: 10.1016/j.heliyon.2023.e22451
    Assessment of activity levels of radionuclides that exist in soil, granite, and charnockite rock samples is very crucial because it exhibits an enhanced elemental concentration of uranium (U) and thorium (Th) contributing higher natural background activity than usual in the environment and it may cause health risk to human health through the external and internal exposure. This study determined the radioactivity levels of 238U, 232Th, and 40K radionuclides in soil, granite, and charnockite rock samples collected from selected fields in Ekiti State, Nigeria using Caesium iodide CsI(Tl) scintillation gamma spectrometer. It also evaluated indices of the radiological parameters consisting of radium equivalent activity (Raeq), absorbed dose rate (DR), annual effective dose equivalent (AEDE), internal hazard index (Hin), and excess lifetime cancer risk (ELCR). The calculated average activity concentrations of 238U, 232Th, and 40K are 30.40 ± 0.71 Bq kg-1, 3.31 ± 0.05 Bq kg-1, and 222.25 ± 14.72 Bq kg-1, respectively, which were lower than their respective world average values. Comparatively, potassium concentrations in these collected samples have a higher value than concentrations of uranium and thorium (40K > 238U > 232Th). All the evaluated values of the radiological parameters (except DR) of the appraised radionuclides were below the global permissible limits. The granite rocks, charnockite rocks, and soils from Ekiti State in Nigeria do not pose any hazardous risk to humans, but continued monitoring is necessary when these materials are used as building materials, which cause long-term radiation exposure.
  16. Usman F, Dennis JO, Meriaudeau F, Ahmed AY, Seong KC, Fen YW, et al.
    Molecules, 2020 Sep 25;25(19).
    PMID: 32992942 DOI: 10.3390/molecules25194414
    The optical constants of Para-Toluene sulfonic acid-doped polyaniline (PANI), PANIchitosan composites, PANI-reduced graphene-oxide composites and a ternary composite comprising of PANI, chitosan and reduced graphene-oxide dispersed in diluted p-toluene sulfonic acid (PTSA) solution and N-Methyl-2-Pyrrolidone (NMP) solvent have been evaluated and compared. The optical constant values were extracted from the absorbance spectra of thin layers of the respective samples. The potential utilization of the materials as the active sensing materials of surface plasmon resonance biosensors has also been assessed in terms of the estimated value of the penetration depth through a dielectric medium. The results show a reasonable dependence of the optical constant parameters on the solvent type. Higher real part refractive index (n) and real part complex dielectric permittivity (ε') values were observed for the samples prepared using PTSA solution, while higher optical conductivity values were observed for the NMP-based samples due to their relatively higher imaginary part refractive index (k) and imaginary part complex dielectric permittivity (ε″) values. In addition, NMP-based samples show improvement in terms of the penetration depth through a dielectric medium by around 9.5, 1.6, 4.4 and 2.9 times compared to PTSA-based samples for the PANI, PANI-chitosan, PANI-RGO and the ternary composites, respectively. Based on these, it is concluded that preparation of these materials using different dispersion solvents could produce materials of different optical properties. Thus, the variation of the dispersion solvent will allow the flexible utilization of the PANI and the composites for diverse applications.