Displaying all 4 publications

Abstract:
Sort:
  1. Suppian R, Vegandraj S, Kandaiya S
    Int J Rad Appl Instrum A, 1992 Jul;43(7):937-8.
    PMID: 1321104
    Pumping air through a soft tissue which acts as a membrane is a relatively easy and quick method to collect and measure radon/thoron and its daughter nuclides in air. Analysis of the activity of the radionuclides can be calculated using an alpha counter which has been calibrated. In this method the activity of radon/thoron cannot be separated from the activity of radionuclides already present in the aerosol or dust particles.
  2. Bradley DA, Chong CS
    Int J Rad Appl Instrum A, 1991;42(8):767-70.
    PMID: 1666633
    New, detailed measurements have been made of the photon spectrum of the radionuclide 241Am. Observations, recorded for a 95% confidence level over local background, provide affirmation of a number of lines previously considered to be of equivocal existence. A number of hitherto unreported emissions are similarly observed. Peak areas, expressed as a percentage of that for the 59.54 keV emission, have been ascribed to all lines of the detailed spectrum. This leads to an estimated increase in the value of exposure calculated from the measured fluence spectrum, relative to that from the 59.54 keV line, of (3.1 +/- 0.8)%, taking into account all emissions beyond the predominating 59.54 keV gamma-ray emission.
  3. Awaluddin AB, Jacobs JJ, Bourne DW, Maddalena DJ, Wilson JG, Boyd RE
    Int J Rad Appl Instrum A, 1987;38(8):671-4.
    PMID: 2822626
    Potential tumor imaging radiopharmaceutical agents have been prepared by attaching a cisplatin derivative to a ligand capable of forming a stable complex with 99mTc. Three new organometallic compounds, with iminodiacetic acid as the 99mTc chelating group and 2,3-diaminopropionamide as the platinum complexing group, have been prepared and characterized. Preliminary biodistribution studies in tumor bearing mice support the utility of this approach.
  4. Bradley DA, Ng KH, Aziz YB
    Int J Rad Appl Instrum A, 1988;39(5):439-40.
    PMID: 2840420
    The utility of a phantom material, based on SMR(L) [Standard Malaysian Rubber] grade natural rubber and a formulation used for the proprietary rubber phantom-material, Temex, has been examined for the 1-MeV photon-Measurement has also been performed with 60-keV photons using the radionuclide 241Am. At photon-therapy energy levels the measured response, when compared with tabulated central-axis percentage depth doses for the defined measuring conditions, produces everywhere (in the range 1-19 cm depth) better than 2% deviation. The favourable measured response characteristics combined with the ease of processing and casting the phantom material provide the basis for useful radiotherapy machine calibration and anthropomorphic dosimetry measurements. The measured mass-attenuation coefficient, at 60keV, of 0.204 cm2 g-1 (+/- 3%) is in close agreement with tabulated values for water (0.2055 cm2 g-1).
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links