Displaying all 9 publications

Abstract:
Sort:
  1. Elnafar AA, Alam MK, Hasan R
    J Orthod, 2014 Sep;41(3):201-7.
    PMID: 25143559 DOI: 10.1179/1465313314Y.0000000097
    The aim of this study was to assess the effects of four enamel preparation techniques on shear bond strength (SBS) of brackets bonded with a resin-modified glass ionomer cement (RMGIC). Adhesive Remnant Index (ARI) and enamel surface roughness (Ra) were also investigated after cement removal.
  2. Norman NH, Worthington H, Chadwick SM
    J Orthod, 2016 Sep;43(3):176-85.
    PMID: 26836747 DOI: 10.1080/14653125.2015.1122260
    OBJECTIVE: To compare the clinical performance of nickel titanium (NiTi) versus stainless steel (SS) springs during orthodontic space closure.
    DESIGN: Two-centre parallel group randomized clinical trial.
    SETTING: Orthodontic Department University of Manchester Dental Hospital and Orthodontic Department Countess of Chester Hospital, United Kingdom.
    SUBJECTS AND METHODS: Forty orthodontic patients requiring fixed appliance treatment were enrolled, each being randomly allocated into either NiTi (n = 19) or SS groups (n = 21). Study models were constructed at the start of the space closure phase (T0) and following the completion of space closure (T1). The rate of space closure achieved for each patient was calculated by taking an average measurement from the tip of the canine to the mesiobuccal groove on the first permanent molar of each quadrant.
    RESULTS: The study was terminated early due to time constraints. Only 30 patients completed, 15 in each study group. There was no statistically significant difference between the amounts of space closed (mean difference 0.17 mm (95%CI -0.99 to 1.34; P = 0.76)). The mean rate of space closure for NiTi coil springs was 0.58 mm/4 weeks (SD 0.24) and 0.85 mm/4 weeks (SD 0.36) for the stainless steel springs. There was a statistically significant difference between the two groups (P = 0.024), in favour of the stainless steel springs, when the mean values per patient were compared.
    CONCLUSIONS: Our study shows that stainless steel springs are clinically effective; these springs produce as much space closure as their more expensive rivals, the NiTi springs.
  3. Ghazali L, Mohd Yusof MYP, Norman NH
    J Orthod, 2021 03;48(1):5-12.
    PMID: 33200660 DOI: 10.1177/1465312520971641
    OBJECTIVES: To investigate the effect of reducing scanning parameters of digital dental panoramic tomogram (DPT) and lateral cephalometric (LC) radiographs on quality and diagnostic performance of the images.

    DESIGN: Single-centre prospective two-arm parallel randomised controlled trial.

    SETTING: Orthodontic Clinic, Faculty of Dentistry, Universiti Teknologi MARA, Selangor, Malaysia.

    PARTICIPANTS: Adult orthodontic patients aged 18-35 years, indicated for DPT and LC, who were fit and healthy with a body mass index of 18.5-25.0, not contraindicated to radiographic examination, not pregnant, and did not have a history of facial or skeletal abnormalities or bone diseases were included.

    METHODS: Thirty-eight adult orthodontic patients were randomised into control and intervention groups. DPT and LC radiographs in the control group were obtained using standard scanning parameters as prescribed by the manufacturer using Orthopantomograph® OP300 by Instrumentarium. Scanning parameters in the intervention group were reduced by 60% for DPT (60 kV, 3.2 mA) and 30% for LC (85 kV, 8 mA). A five-point rating scale was used for the assessment of image quality. Images were evaluated for diagnostic performance by detection of anatomical landmarks. Mann-Whitney test was performed to compare the quality and diagnostic performance of the images and the observer agreement was assessed using the intraclass correlation coefficient (ICC).

    RESULTS: For image quality, the control group produced slightly lower median scores (DPT 2.0, LC 2.0) compared to the intervention group (DPT 2.0, LC 3.0). For diagnostic performance, both groups showed similar median scores (DPT 21.0, LC 32.0). The differences between control and intervention groups for both modalities were not statistically significant. The average scores for intra-observer agreement were excellent (ICC 0.917) and inter-observer agreement was good (ICC 0.822).

    CONCLUSION: Minimising radiation exposure by reducing scanning parameters on digital DPT by 60% and LC by 30% on Intsrumentarium 300 OP did not affect the quality and diagnostic performance of the images. Thus, scanning parameters on digital DPT and LC should be reduced when taking radiographs.

  4. Shahrul AI
    J Orthod, 2021 09;48(3):295-299.
    PMID: 33757377 DOI: 10.1177/14653125211000055
    Mirrorless cameras have seen rapid advancements in recent years. Orthodontists may benefit from these technological advancements in their daily orthodontic practice. This article will explore the advantages and disadvantages of mirrorless cameras, and assess how these camera compare to the tried-and-tested digital single-lens reflex (DSLR) camera.
  5. Santini A, Tiu SH, McGuinness NJ, Aldossary MS
    J Orthod, 2016 Sep;43(3):193-201.
    PMID: 27487476 DOI: 10.1080/14653125.2016.1205310
    OBJECTIVE: To evaluate the total light energy (TLE) transmission through three types of ceramic brackets with, bracket alone and with the addition of orthodontic adhesive, at different exposure durations, and to compare the microhardness of the cured adhesive.

    MATERIALS AND METHODS: Three different makes of ceramic brackets, Pure Sapphire(M), Clarity™ ADVANCED(P) and Dual Ceramic(P) were used. Eighteen specimens of each make were prepared and allocated to three groups (n = 6). MARC(®)-resin calibrator was used to determine the light curing unit (LCU) tip irradiance (mW/cm(2)) and TLE (J/cm(2)) transmitted through the ceramic brackets, and through ceramic bracket plus Transbond™ XT Light Cure Adhesive, for 5, 10 and 20 s. Vickers-hardness values at the bottom of the cured adhesive were determined. Statistical analysis used one-way analysis of variance (ANOVA); P = 0.05.

    RESULTS: TLE transmission rose significantly among all samples with increasing exposure durations. TLE reaching the adhesive- enamel interface was less than 10 J/cm(2), and through monocrystalline and polycrystalline ceramic brackets was significantly different (P 

  6. Abohabib AM, Fayed MM, Labib AH
    J Orthod, 2018 09;45(3):149-156.
    PMID: 29874972 DOI: 10.1080/14653125.2018.1481710
    OBJECTIVE: To investigate the effect of low-intensity laser therapy on mini-implant stability using resonance frequency analysis during canine retraction with fixed appliances.

    DESIGN: A split-mouth randomised clinical trial.

    SETTING: Subjects were recruited and treated in the outpatient clinic, Department of Orthodontics, Faculty of Dentistry, Cairo University.

    PARTICIPANTS: Fifteen subjects with mean age 20.9 (±3.4) years who required extraction of maxillary first premolar teeth and mini-implant-supported canine retraction.

    METHODS: Thirty orthodontic mini-implants were inserted bilaterally in the maxillary arches of recruited subjects following alignment and levelling. Mini-implants were immediately loaded with a force of 150 g using nickel titanium coil springs with split-mouth randomisation to a low-intensity laser-treated side and control side. The experimental sides were exposed to low-intensity laser therapy from a diode laser with a wavelength of 940 nm at (0, 7, 14, 21 days) after mini-implant placement. Mini-implant stability was measured using resonance frequency analysis at (0, 1, 2, 3, 4, 6, 8, 10 weeks) after implant placement.

    RESULTS: A total sample of 28 mini-implants were investigated with 14 in each group. Clinically, both mini-implant groups had the same overall success rate of 78.5%. There were no significant differences in resonance frequency scores between low-intensity laser and control sides from baseline to week 2. However, from week 3 to 10, the low-intensity laser sides showed significantly increased mean resonance frequency values compared to control (P > 0.05).

    CONCLUSIONS: Despite evidence of some significant differences in resonance frequency between mini-implants exposed to low-intensity laser light over a 10 weeks period there were no differences in mini-implant stability. Low-intensity laser light cannot be recommended as a clinically useful adjunct to promoting mini-implant stability during canine retraction.

  7. Prithiviraj D
    J Orthod, 2023 Jun;50(2):253.
    PMID: 37232159 DOI: 10.1177/14653125231172851
  8. Chong JA, Mah EC
    J Orthod, 2023 Jul 04.
    PMID: 37401621 DOI: 10.1177/14653125231185362
    BACKGROUND: Identification of tooth ankylosis before comprehensive orthodontic treatment can be challenging. This case series illustrates different presentations of tooth ankylosis, the importance of early diagnosis, the use of surgical luxation to aid orthodontic alignment of ankylosed teeth and its sequelae.

    CASE PRESENTATION: All three cases were adolescents: a 14-year-old girl with a highly placed upper left lateral incisor and history of general anaesthesia; a 14-year-old boy with an impacted upper right first premolar and history of dental trauma; and a 13-year-old girl with an infraoccluded upper left central incisor with history of replantation due to avulsion. Iatrogenic malocclusion developed from attempts to align ankylosed teeth. Subsequently, surgical luxation was performed, and the ankylosed teeth were successfully aligned. However, it was associated with pulp calcification, root resorption and recurrence of ankylosis.

    CONCLUSION: Surgical luxation and orthodontic alignment of ankylosed teeth can be considered a useful short-term solution to delay the need of surgical removal and teeth replacement.

  9. Pubalan S, Zi Hong O, Yongxian T, Mabel L
    J Orthod, 2024 Feb 17.
    PMID: 38366912 DOI: 10.1177/14653125241230561
    OBJECTIVE: To evaluate the difference in the oral hygiene status of participants with fixed appliances between a 'weekly WhatsApp application oral hygiene message reminders' trial group and a 'verbal instructions' control group over a follow-up duration of 12 weeks.

    DESIGN: Prospective, single-blind, randomised controlled trial with an allocation ratio of 1:1 over a 12-week follow-up.

    SETTING: Government Orthodontic Unit, Raub Dental Clinic, Raub, Pahang, Ministry of Health, Malaysia.

    PARTICIPANTS: A total of 40 patients aged 13-25 years undergoing orthodontic treatment with fixed appliances.

    METHODS: The 40 patients were recruited and randomly allocated to a control (n = 20) or trial group (n = 20). Participants in the trial group received weekly oral hygiene reminders via the WhatsApp application for 12 weeks, while the control group did not receive any reminders. The primary outcome was oral hygiene, which was measured by the single-blinded examiner using the Orthodontic Plaque Index (OPI) at three orthodontic check-ups: baseline (T0); 6-week follow-up (T1); and 12-week follow-up (T2).

    RESULTS: The mean age was 17 years, and 80% were female patients. At the end of the 12-week follow-up, improvements in OPI scores were observed, regardless of the intervention. At T2, the median OPI score for the trial group (n = 20) was 0 (interquartile range [IQR = 0) while that for the control group (n = 20) was 2 (IQR = 0). A Mann-Whitney U test revealed a statistically significant difference (P <0.05), with effect size r = 0.87 between the control and trial groups, whereby the latter witnessed marked improvement in OPI throughout the visits. No harms or adverse effects occurred in this trial.

    CONCLUSION: The short-term findings demonstrated that participants receiving regular reminders of oral hygiene via WhatsApp messaging had a significant improvement in oral hygiene compared to the control group.

Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links