Displaying all 3 publications

Abstract:
Sort:
  1. Peh KK, Yuen KH, Wong JW, Toh WT
    Drug Dev Ind Pharm, 1999 Mar;25(3):357-60.
    PMID: 10071830
    A study was conducted to compare the bioavailability of a generic product of atenolol (Normaten FC) with the innovator product, Tenormin. Twelve healthy adult volunteers participated in the study conducted according to a randomized, two-way crossover design. The preparations were compared using area under the plasma concentration-time curve AUC0-infinity, peak plasma concentration Cmax, and time to reach peak plasma concentration Tmax. No statistically significant difference was obtained between the Tmax values and the logarithmic transformed AUC0-infinity and Cmax values of the two products. Moreover, the 90% confidence interval for the ratio of the logarithmically transformed AUC0-infinity values of Normaten FC over those of Tenormin was found to lie between 0.82 and 0.98, while that of the logarithmically transformed Cmax values was between 0.82 and 1.09, both being within the bioequivalence limit of 0.80-1.25. The values of elimination half-life t1/2 between the two products were also found comparable and not significantly different statistically. The t1/2 values obtained in our study were slightly longer than those reported in the literature for other population groups.
    Matched MeSH terms: Atenolol/pharmacokinetics*
  2. Venkatesh G, Ramanathan S, Nair NK, Mansor SM, Sattar MA, Khan MA, et al.
    Biomed Chromatogr, 2007 May;21(5):484-90.
    PMID: 17294505
    A simple and sensitive RP-HPLC-UV method was developed and validated for simultaneous determination of atenolol and propranolol and subsequently applied to investigate the effect of dimethyl sulfoxide in rat in situ intestinal permeability studies. Atenolol (400 microm) and propranolol (100 microm) were perfused in the small intestine of anaesthetized (pentobarbitone sodium 60 mg/kg, i.p.) male Sprague-Dawley rats either in the presence (1, 3 and 5%) or in the absence of dimethyl sulfoxide. There was no significant alteration (p > 0.05) in the permeability of atenolol and propranolol, which indicated there was no effect of various concentrations of dimethyl sulfoxide (1-5%) on the membrane integrity of the rat intestinal tissues. The analytical method was validated on a C(4) column with a mobile phase comprising ammonium acetate buffer (pH 3.5, 0.02 m) and acetonitrile in the ratio of 30:70 (v/v) at a flow rate of 1.0 mL/min. The validated method was found to be accurate and precise and stability studies were carried out at different storage conditions and both analytes were found to be stable. These findings are applicable for determining the absorbability of water-insoluble drugs and new chemical entities for the purpose of classifying them in the biopharmaceutical classification system.
    Matched MeSH terms: Atenolol/pharmacokinetics*
  3. Venkatesh G, Ramanathan S, Mansor SM, Nair NK, Sattar MA, Croft SL, et al.
    J Pharm Biomed Anal, 2007 Mar 12;43(4):1546-51.
    PMID: 17157469
    A simple, sensitive and specific reversed phase high performance liquid chromatographic (RP-HPLC) method with UV detection at 251 nm was developed for simultaneous quantitation of buparvaquone (BPQ), atenolol, propranolol, quinidine and verapamil. The method was applicable in rat in situ intestinal permeability study to assess intestinal permeability of BPQ, a promising lead compound for Leishmania donovani infections. The method was validated on a C-4 column with mobile phase comprising ammonium acetate buffer (0.02 M, pH 3.5) and acetonitrile in the ratio of 30:70 (v/v) at a flow rate of 1.0 ml/min. The retention times for atenolol, quinidine, propranolol, verapamil and BPQ were 4.30, 5.96, 6.55, 7.98 and 8.54 min, respectively. The calibration curves were linear (correlation coefficient > or =0.996) in the selected range of each analyte. The method is specific and sensitive with limit of quantitation of 15 microg/ml for atenolol, 0.8 microg/ml for quinidine, 5 microg/ml for propranolol, 10 microg/ml for verapamil and 200 ng/ml for BPQ. The validated method was found to be accurate and precise in the working calibration range. Stability studies were carried out at different storage conditions and all the analytes were found to be stable. This method is simple, reliable and can be routinely used for accurate permeability characterization.
    Matched MeSH terms: Atenolol/pharmacokinetics