  1. Murugaiyah V, Chan KL
    J Chromatogr A, 2007 Jun 22;1154(1-2):198-204.
    PMID: 17418855
    A new and simple analytical method using HPLC with fluorescence detection was developed for the simultaneous determination of four lignans (phyllanthin, hypophyllanthin, phyltetralin and niranthin) in Phyllanthus niruri L. plant samples. Optimal separation was achieved with an isocratic mobile phase consisting of acetonitrile-water (55:45 v/v). The method recorded limits of detection (S/N=5) for phyllanthin at 0.61 ng/mL, hypophyllanthin at 6.02 ng/mL, phyltetralin at 0.61 ng/mL and niranthin at 1.22 ng/mL, being 80, 8, 80 and 40 times, respectively, lower when compared with those derived using HPLC-UV detection. The limits of quantification (S/N=12) were 4.88 ng/mL for phyllanthin and phyltetralin, 9.76 ng/mL for niranthin and 24.4 ng/mL for hypophyllanthin showing 40, 8 and 20 times, respectively, lower than those from the UV detection method. The within-day and between-day accuracy for the four lignans were between 98.1% and 102.9% while their precision values were below 2.2%. The mean recovery was between 92.5% and 110.1%. The method was then successfully applied for the quantification of lignans in P. niruri plant samples. The highest amount of lignans was found in the leaves followed by fruits, branches and stem, whilst the roots have the least amount of lignans.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  2. Ching LS, Mohamed S
    J Agric Food Chem, 2001 Jun;49(6):3101-5.
    PMID: 11410015
    Vitamin E was determined by the high-performance liquid chromatography (HPLC) method. All the plants tested showed differences in their alpha-tocopherol content and the differences were significant (p < 0.05). The highest alpha-tocopherol content was in Sauropus androgynus leaves (426.8 mg/kg edible portion), followed by Citrus hystrix leaves (398.3 mg/kg), Calamus scipronum (193.8 mg/kg), starfruit leaves Averrhoa belimbi (168.3 mg/kg), red pepper Capsicum annum (155.4 mg/kg), local celery Apium graveolens (136.4 mg/kg), sweet potato shoots Ipomoea batatas (130.1 mg/kg), Pandanus odorus (131.5 mg/kg), Oenanthe javanica (146.8 mg/kg), black tea Camelia chinensis (183.3 mg/kg),papaya Carica papaya shoots (111.3 mg/kg), wolfberry leaves Lycium chinense (94.4 mg/kg), bird chili Capsicum frutescens leaves (95.4 mg/kg), drumstick Moringa oleifera leaves (90.0 mg/kg), green chili Capsicum annum (87 mg/kg), Allium fistulosum leaves (74.6 mg/kg), and bell pepper Capsicum annum (71.0 mg/kg). alpha-Tocopherol was not detected in Brassica oleracea, Phaeomeria speciosa, Pachyrrhizus speciosa, Pleurotus sajor-caju, and Solanum melongena.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods
  3. Yuen KH, Choy WP, Tan HY, Wong JW, Yap SP
    J Pharm Biomed Anal, 2001 Feb;24(4):715-9.
    PMID: 11272330
    A simple high-performance liquid chromatographic method was developed for the determination of omeprazole in human plasma. Omeprazole and the internal standard, chloramphenicol, were extracted from alkalinized plasma samples using dichloromethane. The mobile phase was 0.05 M Na2HPO4-ACN (65:35, v/v) adjusted to pH 6.5. Analysis was run at a flow rate of 1.0 ml/min at a detection wavelength of 302 nm. The method was specific and sensitive with a detection limit of 2.5 ng/ml at a signal-to-noise ratio of 4:1. The limit of quantification was set at 5 ng/ml. The calibration curve was linear over a concentration range of 5-1280 ng/ml. Mean recovery value of the extraction procedure was about 96%, while the within and between day coefficient of variation and percent error values of the assay method were all less than 14%.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  4. Syed HK, Liew KB, Loh GO, Peh KK
    Food Chem, 2015 Mar 1;170:321-6.
    PMID: 25306352 DOI: 10.1016/j.foodchem.2014.08.066
    A stability-indicating HPLC-UV method for the determination of curcumin in Curcuma longa extract and emulsion was developed. The system suitability parameters, theoretical plates (N), tailing factor (T), capacity factor (K'), height equivalent of a theoretical plate (H) and resolution (Rs) were calculated. Stress degradation studies (acid, base, oxidation, heat and UV light) of curcumin were performed in emulsion. It was found that N>6500, T<1.1, K' was 2.68-3.75, HETP about 37 and Rs was 1.8. The method was linear from 2 to 200 μg/mL with a correlation coefficient of 0.9998. The intra-day precision and accuracy for curcumin were ⩽0.87% and ⩽2.0%, while the inter-day precision and accuracy values were ⩽2.1% and ⩽-1.92. Curcumin degraded in emulsion under acid, alkali and UV light. In conclusion, the stability-indicating method could be employed to determine curcumin in bulk and emulsions.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  5. Liew KB, Peh KK, Fung Tan YT
    Pak J Pharm Sci, 2014 Sep;27(5):1303-7.
    PMID: 25176366
    The effect of deprotenizing agents on recovery of donepezil hydrochloride in the development of a simple, rapid, selective and sensitive high performance liquid chromatography method for quantification of donepezil hydrochloride in human plasma was described. The deprotenizing agents were comprised of, perchloric acid, methanol, acetonitrile, chloroform and their mixtures. The chromatographic separation was carried out using reversed phase C18 column (Agilent Eclipse Plus C18) with UV detection at 268 nm. The mobile phase was comprised of 0.01 M potassium dihydrogen phosphate buffer, methanol and acetronitrile (50:30:20, v/v) adjusted to pH 2.7 with phosphoric acid (80%). A combination of perchloric acid and methanol gave a cleaner sample with a good recovery of donepezil hydrochloride of above 96%. The method showed intraday precision and accuracy in the range of 6.82% to 1.5% and 3.13% to 1.12% respectively, while interday precision and accuracy ranged between 1.06% to 4.71% and 13.01% to 6.43% respectively. The standard calibration curve was linear from 30ng/mL to 4000ng/mL, with a correlation coefficient of 0.9965±0.0034. The retention time of donepezil was 5.9 min with a run time of 7.0 min. The method can be applied to analyze large batch plasma samples in pharmacokinetic studies.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  6. Yudthavorasit S, Wongravee K, Leepipatpiboon N
    Food Chem, 2014 Sep 1;158:101-11.
    PMID: 24731320 DOI: 10.1016/j.foodchem.2014.02.086
    Chromatographic fingerprints of gingers from five different ginger-producing countries (China, India, Malaysia, Thailand and Vietnam) were newly established to discriminate the origin of ginger. The pungent bioactive principles of ginger, gingerols and six other gingerol-related compounds were determined and identified. Their variations in HPLC profiles create the characteristic pattern of each origin by employing similarity analysis, hierarchical cluster analysis (HCA), principal component analysis (PCA) and linear discriminant analysis (LDA). As results, the ginger profiles tended to be grouped and separated on the basis of the geographical closeness of the countries of origin. An effective mathematical model with high predictive ability was obtained and chemical markers for each origin were also identified as the characteristic active compounds to differentiate the ginger origin. The proposed method is useful for quality control of ginger in case of origin labelling and to assess food authenticity issues.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  7. Ariffin AA, Ghazali HM, Kavousi P
    Food Chem, 2014 Jul 1;154:102-7.
    PMID: 24518321 DOI: 10.1016/j.foodchem.2013.12.082
    For the first time 5-hydroxymethyl-2-furaldehyde (HMF) was separated from crude palm oil (CPO), and its authenticity was determined using an RP-HPLC method. Separation was accomplished with isocratic elution of a mobile phase comprising water and methanol (92:8 v/v) on a Purospher Star RP-18e column (250mm×4.6mm, 5.0μm). The flow rate was adjusted to 1ml/min and detection was performed at 284nm. The method was validated, and results obtained exhibit a good recovery (95.58% to 98.39%). Assessment of precision showed that the relative standard deviations (RSD%) of retention times and peak areas of spiked samples were less than 0.59% and 2.66%, respectively. Further, the limit of detection (LOD) and LOQ were 0.02, 0.05mg/kg, respectively, and the response was linear across the applied ranges. The crude palm oil samples analysed exhibited HMF content less than 2.27mg/kg.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  8. Zare D, Muhammad K, Bejo MH, Ghazali HM
    J Chromatogr A, 2012 Sep 21;1256:144-9.
    PMID: 22885043 DOI: 10.1016/j.chroma.2012.07.083
    Urocanic acid (UCA) has been reported to be a mast cell degranulator and has also been suggested as a complementary agent in implicated scombroid fish poisoning. In this research, a new method is described to extract, clean up and perform simultaneous ion-pair chromatographic analysis of trans- and cis-urocanic acid (UCA) in fish samples. UCA was extracted using 0.05 M HCl and protein was removed from the extract by precipitation with 10% trisodium citrate and 10% citric acid. The HPLC method that is developed showed a rapid, precise and sensitive method with short retention time for simultaneous separation of UCA isomers in fish samples. Estimation of trans- and cis-UCA in the muscle of Indian mackerel, tuna and sardine showed that, as expected, no cis-UCA existed in fish muscles and the highest concentration of trans-UCA was found in Indian mackerel with 118.8 mg kg(-1) while the highest concentrations of trans-UCA in tuna and sardine were 12.1 and 17.5 mg kg(-1), respectively.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  9. Yam MF, Mohamed EA, Ang LF, Pei L, Darwis Y, Mahmud R, et al.
    J Acupunct Meridian Stud, 2012 Aug;5(4):176-82.
    PMID: 22898066 DOI: 10.1016/j.jams.2012.05.005
    Orthosiphon stamineus extracts contain three flavonoids (3'-hydroxy-5,6,7,4'-tetramethoxyflavone, sinensetin, and eupatorin) as bioactive substances. Previous reported high performance liquid chromatography- ultraviolet (HPLC-UV) methods for the determination of these flavonoids have several disadvantages, including unsatisfactory separation times and not being well validated according to International Conference on Harmonisation of Technical Requirements for Registration of Pharmaceuticals for Human Use (ICH) standard guidelines. A rapid, specific reversed-phase HPLC method with isocratic elution of acetonitrile: isopropyl alcohol: 20mM phosphate buffer (NaH(2)PO(4)) (30:15:55, v/v) (pH 3.5) at a flow-rate of 1ml/minute, a column temperature of 25°C, and ultraviolet (UV) detection at 340 nm was developed. The method was validated and applied for quantification of different types of O stamineus extracts and fractions. The method allowed simultaneous determination of 3'-hydroxy-5,6,7,4'-tetramethoxyflavone, sinensetin, and eupatorin in the concentration range of 0.03052-250 μg/ml. The limits of detection and quantification, respectively, were 0.0076 and 0.061 μg/ml for 3'-hydroxy-5,6,7,4'-tetramethoxyflavone, 0.0153 and 0.122 μg/ml for sinensetin and 0.0305 and 0.122 μg/ml for eupatorin. The percent relative standard deviation (% RSD) values for intraday were 0.048-0.368, 0.025-0.135, and 0.05-0.476 for 3'-hydroxy-5,6,7,4'-tetramethoxyflavone, sinensetin, and eupatorin, respectively, and those for intraday precision were 0.333-1.688, 0.722-1.055, and 0.548-1.819, respectively. The accuracy for intraday were 91.25%-103.38%, 94.32%-109.56%, and 92.85%-109.70% for 3'-hydroxy-5,6,7,4'-tetramethoxyflavone, sinensetin, and eupatorin, respectively, and those for interday accuracy were 97.49%-103.92%, 103.58%-104.57%, and 103.9%-105.33%, respectively. The method was found to be simple, accurate and precise and is recommended for routine quality control analysis of O stamineus extract containing the three flavonoids as the principle components in the extract.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  10. Tameem AA, Saad B, Makahleh A, Salhin A, Saleh MI
    Talanta, 2010 Sep 15;82(4):1385-91.
    PMID: 20801345 DOI: 10.1016/j.talanta.2010.07.004
    A sorbent material based on a newly synthesized hydrazone ligand, 4-hydroxy-N'-[(E)-(2-hydroxyphenyl)methylidene]benzohydrazide was prepared by immobilizing the ligand into a silica sol-gel matrix. The capability of the sorbent material for the extraction of seven biogenic amines (BAs), i.e., tryptamine (TRY), beta-phenylethylamine (PEA), putrescine (PUT), cadaverine (CAD), histamine (HIS), tyramine (TYR), and spermidine (SPD) was studied. Under the adopted conditions, the sorbent showed good selectivity towards PUT, CAD, HIS and SPD (% extraction (%E)>96) while %E for TYR, TRY and PEA were 82.0, 78.9 and 46.4%, respectively. The sorbent could be used up to six extraction cycles for SPD, CAD and PUT and was applied to the determination of food samples ("budu", ketchup, orange juice, soy sauce) that were spiked with 20 mg L(-1) of the BAs. The extracted analytes were derivatized with dansyl chloride before the HPLC determination. With the exception of HIS and TYR in "budu" sample, reasonable recoveries were found for the other analytes in all the tested food samples.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  11. Saaid M, Saad B, Ali AS, Saleh MI, Basheer C, Lee HK
    J Chromatogr A, 2009 Jul 3;1216(27):5165-70.
    PMID: 19481215 DOI: 10.1016/j.chroma.2009.04.091
    Hollow fibre liquid-phase microextraction with in situ derivatization using dansyl chloride has been successfully developed for the high-performance liquid chromatography-ultraviolet (HPLC-UV) determination of the biogenic amines (tryptamine, putrescine, cadaverine, histamine, tyramine, spermidine) in food samples. Parameters affecting the performance of the in situ derivatization process such as type of extraction solvent, temperature, extraction time, stirring speed and salt addition were studied and optimized. Under the optimized conditions (extraction solvent, dihexyl ether; acceptor phase, 0.1M HCl; extraction time, 30 min; extraction temperature, 26 degrees C; without addition of salt), enrichment factors varying from 47 to 456 were achieved. Good linearity of the analytes was obtained over a concentration range of 0.1-5 microg mL(-1) (with correlation coefficients of 0.9901-0.9974). The limits of detection and quantification based on a signal-to-noise ratio of 3-10, ranged from 0.0075 to 0.030 microg mL(-1) and 0.03 to 0.10 microg mL(-1), respectively. The relative standard deviations based on the peak areas for six replicate analysis of water spiked with 0.5 microg mL(-1) of each biogenic amine were lower than 7.5%. The method was successfully applied to shrimp sauce and tomato ketchup samples, offering an interesting alternative to liquid-liquid extraction and solid phase extraction for the analysis of biogenic amines in food samples.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  12. Tay BY, Yung SC, Teoh TY
    Int J Cosmet Sci, 2016 Dec;38(6):627-633.
    PMID: 27169828 DOI: 10.1111/ics.12342
    OBJECTIVE: Isopropyl p-toluenesulfonate (IPTS) is a potentially genotoxic by-product formed during the esterification of palm oil-based palmitic and palm kernel oil-based myristic acid with isopropanol to produce isopropyl palmitate or isopropyl myristate. There are no methods described for the analysis of IPTS in cosmetic products. In this work, we have established a simple, precise and accurate method to determine the presence and level of IPTS in various finished cosmetic products which contain palm-based esters in their formulations.

    METHODS: An Agilent 1200 series high-performance liquid chromatography (HPLC) unit using a diode-array detector (DAD) has been employed and optimized to detect IPTS in cosmetic products. For the separation, a reverse-phase Hypersil Gold C8 column (5 μm, 4.6 mm i.d. 250 mm) 5 mM tetrabutylammonium phosphate buffer 50 : 50, (v/v) solution in acetonitrile as mobile phase, in isocratic mode and a flow rate of 0.8 mL min(-1) were used. A second method using a gas chromatography/mass selective detector GC-MSD was also developed to confirm the IPTS identity in the cosmetic products.

    RESULTS: Recoveries of IPTS from cosmetic matrices such as a lotion, cleansing milk and a cream ranged from 94.0% to 101.1% with <5% relative standard deviation (%RSD) showing good accuracy and repeatability of the method. The six-point calibration curves (determined over the range 0.5-50 μg mL(-1) ) have a correlation coefficient of 0.9999 (based on HPLC peak area) and 0.9998 (based on HPLC peak height). The intra- and interday precisions (measured by the %RSD) of the method were <2% and <5%, respectively, indicating that the developed method is reliable, precise and reproducible. The detection and quantification limit of the method were found to be 0.5 μg mL(-1) and 1.6 μg mL(-1) , respectively. Analyses of 83 commercial cosmetics showed no presence of IPTS.

    CONCLUSIONS: The validation data indicated that this method was suitable for the quantitative analysis of IPTS in commercial cosmetics. This method is applicable for analyses of trace levels of IPTS in cosmetics and has the advantage of using only simple sample preparation steps.

    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  13. Miean KH, Mohamed S
    J Agric Food Chem, 2001 Jun;49(6):3106-12.
    PMID: 11410016
    Studies were conducted on the flavonoids (myricetin, quercetin, kaempferol, luteolin, and apigenin) contents of 62 edible tropical plants. The highest total flavonoids content was in onion leaves (1497.5 mg/kg quercetin, 391.0 mg/kg luteolin, and 832.0 mg/kg kaempferol), followed by Semambu leaves (2041.0 mg/kg), bird chili (1663.0 mg/kg), black tea (1491.0 mg/kg), papaya shoots (1264.0 mg/kg), and guava (1128.5 mg/kg). The major flavonoid in these plant extracts is quercetin, followed by myricetin and kaempferol. Luteolin could be detected only in broccoli (74.5 mg/kg dry weight), green chili (33.0 mg/kg), bird chili (1035.0 mg/kg), onion leaves (391.0 mg/kg), belimbi fruit (202.0 mg/kg), belimbi leaves (464.5 mg/kg), French bean (11.0 mg/kg), carrot (37.5 mg/kg), white radish (9.0 mg/kg), local celery (80.5 mg/kg), limau purut leaves (30.5 mg/kg), and dried asam gelugur (107.5 mg/kg). Apigenin was found only in Chinese cabbage (187.0 mg/kg), bell pepper (272.0 mg/kg), garlic (217.0 mg/kg), belimbi fruit (458.0 mg/kg), French peas (176.0 mg/kg), snake gourd (42.4 mg/kg), guava (579.0 mg/kg), wolfberry leaves (547.0 mg/kg), local celery (338.5 mg/kg), daun turi (39.5 mg/kg), and kadok (34.5 mg/kg). In vegetables, quercetin glycosides predominate, but glycosides of kaempferol, luteolin, and apigenin are also present. Fruits contain almost exclusively quercetin glycosides, whereas kaempferol and myricetin glycosides are found only in trace quantities.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods
  14. Lo SK, Baharin BS, Tan CP, Lai OM
    J Chromatogr Sci, 2004 Mar;42(3):145-54.
    PMID: 15023251
    Separation of 1,2(2,3)- and 1,3-positional isomers of diacylglycerols (DAG) from vegetable oils by reversed-phase high-performance liquid chromatography (RP-HPLC) is investigated. The method is based on isocratic elution using 100% acetonitrile and UV detection at 205 nm. The following elution order of DAG molecular species is identified: 1,3-dilinolein < 1,2-dilinolein < 1,3-dimyristin < 1-oleoyl-3-linoleoyl-glycerol < 1,2-dimyristoyl-rac-glycerol < 1(2)-oleoyl-2(3)-linoleoyl-glycerol < 1-linolenoyl-3-stearoyl-glycerol < 1(2)-linolenoyl-2(3)-stearoyl-glycerol < 1,3-diolein < 1-palmitoyl-3-oleoyl-glycerol < 1,2-dioleoyl-sn-glycerol < 1(2)-palmitoyl-2(3)-oleoyl-glycerol < 1-linoleoyl-3-stearoyl-glycerol < 1,3-dipalmitin < 1(2)-linoleoyl-2(3)-stearoyl-glycerol < 1-oleoyl-3-stearoyl-glycerol < 1,2-dipalmitoyl-rac-glycerol < 1-palmitoyl-3-stearoyl-sn-glycerol < 1,3-distearin < 1,2-distearoyl-rac-glycerol. Linearity is observed over three orders of magnitude. Limits of detection and quantitation range 0.2-0.7 microg/mL for 1,3-dilinolein to 0.6-1.9 microg/mL for 1,2-dioleoyl-sn-glycerol, respectively. Precision and accuracy of the method are also demonstrated. The method is developed to separate mixtures of DAG molecular species produced from edible oils.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  15. Ping BTY, Aziz HA, Idris Z
    J Oleo Sci, 2018;67(3):265-272.
    PMID: 29491321 DOI: 10.5650/jos.ess17164
    High-Performance Liquid Chromatography (HPLC) methods via evaporative light scattering (ELS) and refractive index (RI) detectors are used by the local palm oil industry to monitor the TAG profiles of palm oil and its fractions. The quantitation method used is based on area normalization of the TAG components and expressed as percentage area. Although not frequently used, peak-area ratios based on TAG profiles are a possible qualitative method for characterizing the TAG of palm oil and its fractions. This paper aims to compare these two detectors in terms of peak-area ratio, percentage peak area composition, and TAG elution profiles. The triacylglycerol (TAG) composition for palm oil and its fractions were analysed under similar HPLC conditions i.e. mobile phase and column. However, different sample concentrations were used for the detectors while remaining within the linearity limits of the detectors. These concentrations also gave a good baseline resolved separation for all the TAGs components. The results of the ELSD method's percentage area composition for the TAGs of palm oil and its fractions differed from those of RID. This indicates an unequal response of TAGs for palm oil and its fractions using the ELSD, also affecting the peak area ratios. They were found not to be equivalent to those obtained using the HPLC-RID. The ELSD method showed a better baseline separation for the TAGs components, with a more stable baseline as compared with the corresponding HPLC-RID. In conclusion, the percentage area compositions and peak-area ratios for palm oil and its fractions as derived from HPLC-ELSD and RID were not equivalent due to different responses of TAG components to the ELSD detector. The HPLC-RID has a better accuracy for percentage area composition and peak-area ratio because the TAG components response equally to the detector.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  16. Mohamad Hanapi NS, Sanagi MM, Ismail AK, Saim N, Wan Ibrahim WN, Wan Ibrahim WA, et al.
    J Chromatogr Sci, 2018 Feb 01;56(2):166-176.
    PMID: 29069322 DOI: 10.1093/chromsci/bmx092
    Two-phase micro-electrodriven membrane extraction (EME) procedure for the pre-concentration of selected non-steroidal anti-inflammatory drugs (NSAIDs) in aquatic matrices was investigated. Agarose film was used as interface between donor and acceptor phase in EME which allowed for selective extraction of the analytes prior to high performance liquid chromatography-ultraviolet detection. Charged analytes were transported from basic aqueous sample solution through agarose film into 1-octanol as an acceptor phase at 9 V potential. Response surface methodology in conjunction with the central composite design showed good correlations between extraction time and applied voltage (R2 > 0.9358). Under optimized extraction conditions, the method showed good linearity in the concentration range of 0.5-500 μg L-1 with coefficients of determination, r2≥ 0.9942 and good limits of detection (0.14-0.42 μg L-1) and limits of quantification (0.52-1.21 μg L-1). The results also showed high enrichment factors (62-86) and good relative recoveries (72-114%) with acceptable reproducibilities (RSDs ≤ 7.5% n = 3). The method was successfully applied to the determination of NSAIDs from tap water and river water samples. The proposed method proved to be rapid, simple and requires low voltage and minute amounts of organic solvent, thus environmentally friendly.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  17. Fong BY, Ma L, Khor GL, van der Does Y, Rowan A, McJarrow P, et al.
    J Agric Food Chem, 2016 Aug 17;64(32):6295-305.
    PMID: 27436425 DOI: 10.1021/acs.jafc.6b02200
    Gangliosides (GA) are found in animal tissues and fluids, such as blood and milk. These sialo-glycosphingolipids have bioactivities in neural development, the gastrointestinal tract, and the immune system. In this study, a high-performance liquid chromatography-mass spectrometry (HPLC-MS) method was validated to characterize and quantitate the GA in beef, chicken, pork, and fish species (turbot, snapper, king salmon, and island mackerel). For the first time, we report the concentration of GM3, the dominant GA in these foods, as ranging from 0.35 to 1.1 mg/100 g and 0.70 to 5.86 mg/100 g of meat and fish, respectively. The minor GAs measured were GD3, GD1a, GD1b, and GT1b. Molecular species distribution revealed that the GA contained long- to very-long-chain acyl fatty acids attached to the ceramide moiety. Fish GA contained only N-acetylneuraminic acid (NeuAc) sialic acid, while beef, chicken, and pork contained GD1a/b species that incorporated both NeuAc and N-glycolylneuraminic acid (NeuGc) and hydroxylated fatty acids.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  18. Chua LS, Segaran A, Wong HJ
    J Chromatogr Sci, 2021 Jun 21;59(7):659-669.
    PMID: 33876232 DOI: 10.1093/chromsci/bmab041
    The objective of the study was to fractionate the crude extract of Eurycoma longifolia (E. longifolia) roots and identify the intense peaks using HPLC-PDA-MS/MS, UPLC-MS/MS and H-NMR. Column chromatography was used to fractionate the crude extract into individual fractions using six solvent systems ranged from ethyl acetate, methanol and water in increasing polarity. Two fractions with nearly pure and intense peaks were selected for compound identification. Chromenone (coumarin) and chromone derivatives were putatively identified, besides several previously reported quassinoid glycosides (eurycomanone derived glycoside, 2,3-dehydro-4α-hydroxylongilactone glucoside, eurycomanol glycoside and eurycomanol trimer) in the fraction 11 of 100% methanol. A newly reported compound, namely hydroxyl glyyunanprosapogenin D (838 g/mol) was proposed to be the compound detected in the fraction 11 of 50% ethyl acetate and 50% methanol. This is also the first study to report the identification of chromenones and chromones in E. longifolia extract.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  19. Yap SP, Julianto T, Wong JW, Yuen KH
    J Chromatogr B Biomed Sci Appl, 1999 Dec 10;735(2):279-83.
    PMID: 10670741
    A simple high-performance liquid chromatographic method using fluorescence detection was developed for the determination of vitamin E especially delta-, gamma- and alpha-tocotrienols in human plasma. The method entailed direct injection of plasma sample after deproteinization using a 3:2 mixture of acetonitrile-tetrahydrofuran. The mobile phase comprised 0.5% (v/v) of distilled water in methanol. Analyses were run at a flow-rate of 1.5 ml/min with the detector operating at an excitation wavelength of 296 nm and emission wavelength of 330 nm. This method is specific and sensitive, with a quantification limit of approximately 40, 34 and 16 ng/ml for alpha-, gamma- and delta-tocotrienol, respectively. The mean absolute recovery values were about 98% while the within-day and between-day relative standard deviation and percent error values of the assay method were all less than 12.0% for alpha-, gamma- and delta-tocotrienol. The calibration curve was linear over a concentration range of 40-2500, 30-4000 and 16-1000 ng/ml for alpha-, gamma- and delta-tocotrienol, respectively. Application of the method in a bioavailability study for determination of the above compounds was also demonstrated.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  20. Julianto T, Yuen KH, Noor AM
    J Chromatogr B Biomed Sci Appl, 1999 Sep 10;732(1):227-31.
    PMID: 10517240
    A simple high-performance liquid chromatographic method using UV detection was developed for the determination of alpha-tocopherol in human plasma. The method entailed direct injection of the plasma sample after deproteinization using acetonitrile-tetrahydrofuran (3:2). The mobile phase comprised methanol-tetrahydrofuran (94:6) and analysis was run at a flow-rate of 1.5 ml/min with the detector operating at 292 nm. A Crestpak C18S (5 microm, 250 mm x 4.6 mm ID) was used for the chromatographic separation. The method had a mean recovery of 93%, while the within-day and between-day coefficients of variation and percentage errors were all less than 7%. The speed, specificity, sensitivity and reproducibility of this method make it particularly suitable for routine determination of alpha-tocopherol in human plasma. Moreover, only a small sample plasma volume (100 microl) is required for the analysis.