OBJECTIVE: We investigated for geographical differences in outcomes after percutaneous coronary intervention (PCI) with the COMBO stent among Asians and Europeans.
METHODS: The COMBO Collaboration is a pooled patient-level analysis of the MASCOT and REMEDEE registries of all-comers undergoing attempted COMBO stent PCI. The primary outcome was 1-year target lesion failure (TLF), composite of cardiac death, target vessel myocardial infarction (TV-MI) and target lesion revascularization (TLR).
RESULTS: This study included 604 Asians (17.9%) and 2775 Europeans (82.1%). Asians were younger and included fewer females, with a higher prevalence of diabetes mellitus but lower prevalence of other comorbidities than Europeans. Asians had a higher prevalence of ACC/AHA C type lesions and received longer stent lengths. More Asians than Europeans were discharged on clopidogrel (86.5% vs 62.8%) rather than potent P2Y12 inhibitors. One-year TLF occurred in 4.0% Asians and 4.1% of Europeans, p = 0.93. The incidence of cardiac death was higher in Asians (2.8% vs. 1.3%, p = 0.007) with similar rates of TV-MI (1.5% vs. 1.2%, p = 0.54) and definite stent thrombosis (0.3% vs. 0.5%, p = 0.84) and lower incidence of TLR than Europeans (1.0% vs. 2.5%, p = 0.025). After adjustment, differences for cardiac death and TLR were no longer significant.
CONCLUSIONS: In the COMBO collaboration, although 1-year TLF was similar regardless of geography, Asians experienced higher rates of cardiac death and lower TLR than Europeans, while incidence of TV-MI and ST was similar in both regions. Adjusted differences did not reach statistical significance. CLINICALTRIAL.
GOV IDENTIFIER-NUMBERS: NCT01874002 (REMEDEE Registry), NCT02183454 (MASCOT registry).
METHODS AND RESULTS: We examined for sex differences in 1-year outcomes after COMBO stenting from the COMBO collaboration, a pooled patient-level dataset from the MASCOT and REMEDEE multicenter registries. The primary endpoint was 1-year target lesion failure (TLF), composite of cardiac death, target vessel-myocardial infarction (TV-MI), or clinically driven target lesion revascularization (CD-TLR). Secondary outcomes included stent thrombosis (ST). Adjusted outcomes were assessed using Cox regression methods. The study included 861 (23.8%) women and 2,753 (76.2%) men. Women were older with higher prevalence of several comorbidities including diabetes mellitus. Risk of 1-year TLF was similar in both sexes (3.8% vs. 3.9%, HR 0.92, 95% CI 0.59-1.42, p = .70), without sex differences in the incidence of cardiac death (1.6% vs. 1.5%, p = .78), TV-MI (1.5% vs. 1.1%, p = .32), or CD-TLR (2.0% vs. 2.2%, p = .67). Definite or probable ST occurred in 0.4% women and 1.0% men (HR 0.26, 95% CI 0.06-1.11, p = .069).
CONCLUSIONS: Despite greater clinical risks at baseline, women treated with COMBO stents had similarly low 1-year TLF and other ischemic outcomes compared to men.
MATERIALS AND METHODS: This was a study involving LMS PCI coronary lesions using the Synergy Megatron DES. An IVUS protocol using predefined optimisation targets to evaluate for stent malapposition, longitudinal stent deformation, optimal stent expansion >90% of reference lumen and appropriate distal landing zone was used in all cases. The primary end-point was procedural success, defined by successful stent implantation with <30% residual stenosis. The secondary end-point was in-hospital and 30-day major adverse cardiovascular event (MACE).
RESULTS: Eight patients with significant LMS stenosis were successfully treated with the Megatron stent. The primary end-point was achieved in all patients. There were no cases of stent malapposition or longitudinal stent deformation, one case did not have optimal LMS stent expansion and one case did not have an appropriate distal landing zone. IVUS optimisation criteria were met in 6 (75%) cases. There were no complications of coronary dissection, slow or no reflow, stent thrombosis or vessel perforation. None of the patients suffered in-hospital or 30-day MACE. The average LMS MLD at baseline was 2.1 ± 0.1mm and the post-PCI LMS MLD was 4.0 ± 0.5mm, with a significant acute luminal gain of 1.9 ± 0.7mm (p<0.01). A post-PCI MSA of 17 ± 3.9 mm2 was numerically superior compared to those documented in other LMS PCI trials.
CONCLUSION: This study demonstrates low rates of shortterm major adverse cardiovascular events among patients with LMS PCI using the Megatron stents. It highlights the usefulness of IVUS-guided optimisation in LMS PCI. With the use of intravascular imaging, the new generation stent technology can improve the treatment of large proximal vessels and PCI of LMS lesions.
METHODS: The REDUCE trial is a prospective, multicenter, investigator-initiated study that randomized ACS patients undergoing PCI with the COMBO drug eluting stent to either 3 or 12 months of DAPT. The study population was divided according to age (
Methods: By means of propensity score (PS) matching 234 individuals with de novo CAD were identified with similar demographic characteristics. This patient population was stratified in a 1:1 fashion according to a reference vessel diameter cut-off of 2.75 mm in small and large vessel disease. The primary endpoint was the rate of clinically driven target lesion revascularization (TLR) at 9 months.
Results: Patients with small vessel disease had an average reference diameter of 2.45 ± 0.23 mm, while the large vessel group averaged 3.16 ± 0.27 mm. Regarding 9-month major adverse cardiac event (MACE), 5.7% of the patients with small and 6.1% of the patients with large vessels had MACE (p=0.903). Analysis of the individual MACE components revealed a TLR rate of 3.8% in small and 1.0% in large vessels (p=0.200). Of note, no thrombotic events in the DCB treated coronary segments occurred in either group during the 9-month follow-up.
Conclusions: Our data demonstrate for the first time that DCB-only PCI of de novo lesions in large coronary arteries (>2.75 mm) is safe and as effective. Interventional treatment for CAD without permanent or temporary scaffolding, demonstrated a similar efficacy for large and small vessels.
METHODS: An all-comer, worldwide single armed trial (ClinicalTrials.gov Identifier NCT02629575) was conducted to demonstrate the safety and efficacy of an ultra-thin strut, polymer-free sirolimus eluting stent (PF-SES). The primary endpoint was the 9-month target revascularization rate (TLR). Secondary endpoints included the rates of major adverse cardiac events (MACE), stent thrombosis (ST) and bleeding (BARC) in septuagenarians (≥70 years, <80 years), and in octogenarians (≥80 years) to be compared to the younger patient group (<70 years).
RESULTS: A total of 1607 patients were treated with PF-SES in the sub-70-year-old age group, 694 in septuagenarians, and 371 in the octogenarian patient group. At 9 months, the MACE rates were 7.2% in octogenarians, 5.3% in septuagenarians, and 3.0% in the younger patient group (P = 0.001). These were mostly driven by all-cause mortality (4.4% vs 1.9% vs 0.6%, P
METHODS: Patients who received PF-SES were investigated in an unselected large-scale international, single-armed, multicenter, 'all comers' observational study. The primary endpoint was the 9-month target lesion revascularisation (TLR) rate, whereas secondary endpoints included the 9-month major adverse cardiac events (MACE) and procedural success rates. A priori defined subgroups such as patients with ACS, diabetes, lesion subsets and procedural characteristics relative to DAPT were investigated.
RESULTS: A total of 2877 patients of whom 1084 had ACS were treated with PF-SES (1.31±0.75 stents per patient). At 9 months, the accumulated overall TLR rate was 2.3% (58/2513). There was no significant difference between ACS and stable CAD (2.6% vs 2.1%, p=0.389). However, the overall MACE rate was 4.3% (108/2513) with a higher rate in patients with ACS when compared with the stable CAD subgroup (6.1%, 58/947 vs 3.2%, 50/1566, p<0.001).
CONCLUSIONS: PF-SES angioplasty is safe and effective in the daily clinical routine with low rates of TLR and MACE in an unselected patient population. Our data are in agreement with prior clinical findings that extended DAPT duration beyond 6 months do not improve clinical outcomes in patients with stable CAD (ClinicalTrials.gov Identifier NCT02629575).
TRIAL REGISTRATION NUMBER: NCT02629575.
METHODS: Two all-comers observational studies based on the same protocol (ClinicalTrials.gov Identifiers: NCT02629575 and NCT02905214) were combined for data analysis to assure sufficient statistical power. The primary endpoint was the accumulated target lesion revascularization (TLR) rate at 9-12 months.
RESULTS: Of the total population of 7243 patients, 44.0% (3186) were recruited in the Mediterranean region and 32.0% (2317) in central Europe. The most prominent Asian region was South Korea (17.6%, 1274) followed by Malaysia (5.7%, 413). Major cardiovascular risk factors varied significantly across regions. The overall rates for accumulated TLR and MACE were low with 2.2% (140/6374) and 4.4% (279/6374), respectively. In ACS patients, there were no differences in terms of MACE, TLR, MI and accumulated mortality between the investigated regions. Moreover, dual antiplatelet therapy (DAPT) regimens were substantially longer in Asian countries even in patients with stable coronary artery disease as compared to those in Europe.
CONCLUSIONS: PF-SES angioplasty is associated with low clinical event rates in all regions. Further reductions in clinical event rates seem to be associated with longer DAPT regimens.