Displaying all 4 publications

Abstract:
Sort:
  1. Lim CW, Cheng J, Tay ELT, Teo HY, Wong EPY, Yong VKY, et al.
    BMC Ophthalmol, 2018 Dec 10;18(1):315.
    PMID: 30526537 DOI: 10.1186/s12886-018-0976-y
    BACKGROUND: Despite the potential usefulness of optical coherence tomography angiography in retinal and optic disc conditions, the reliability of the imaging modality remains unclear. This study set out to measure the microvascular density of macula and optic disc by mean of optical coherence tomography angiography and report the repeatability of the vessel density measurements.

    METHODS: Cross sectional observational cohort study. Subjects with normal eyes were recruited. Two sets of optical coherence tomography angiography images of macula and optic nerve head were acquired during one visit. Novel in-house developed software was used to count the pixels in each images and to compute the microvessel density of the macula and optic disc. Data were analysed to determine the measurement repeatability.

    RESULTS: A total of 176 eyes from 88 consecutive normal subjects were recruited. For macular images, the mean vessel density at superficial retina, deep retina, outer retina and choriocapillaries segment was OD 0.113 and OS 0.111, OD 0.239 and OS 0.230, OD 0.179 and OS 0.164, OD 0.237 and OS 0.215 respectively. For optic disc images, mean vessel density at vitreoretinal interface, radial peripapillary capillary, superficial nerve head and disc segment at the level of choroid were OD 0.084 and OS 0.085, OD 0.140 and OS 0.138, OD 0.216 and OS 0.209, OD 0.227 and OS 0.236 respectively. The measurement repeatability tests showed that the coefficient of variation of macular scans, for right and left eyes, ranged from 6.4 to 31.1% and 5.3 to 59.4%. Likewise, the coefficient of variation of optic disc scans, for right and left eyes, ranged from 14.3 to 77.4% and 13.5 to 75.3%.

    CONCLUSIONS: Optical coherence tomography angiography is a useful modality to visualise the microvasculature plexus of macula and optic nerve head. The vessel density measurement of macular scan by mean of optical coherence tomography angiography demonstrated good repeatability. The optic disc scan, on the other hand, showed a higher coefficient of variation indicating a lower measurement repeatability than macular scan. Interpretation of optical coherence tomography angiography should take into account test-retest repeatability of the imaging system.

    TRIAL REGISTRATION: National Healthcare Group Domain Specific Review Board ( NHG DSRB ) Singapore. DSRB Reference: 2015/00301.

    Matched MeSH terms: Optic Disk/blood supply*
  2. Ismail A, Bhatti MS, Faye I, Lu CK, Laude A, Tang TB
    Graefes Arch Clin Exp Ophthalmol, 2018 Sep;256(9):1711-1721.
    PMID: 29876732 DOI: 10.1007/s00417-018-4030-9
    PURPOSE: To evaluate and compare the temporal changes in pulse waveform parameters of ocular blood flow (OBF) between non-habitual and habitual groups due to caffeine intake.

    METHOD: This study was conducted on 19 healthy subjects (non-habitual 8; habitual 11), non-smoking and between 21 and 30 years of age. Using laser speckle flowgraphy (LSFG), three areas of optical nerve head were analyzed which are vessel, tissue, and overall, each with ten pulse waveform parameters, namely mean blur rate (MBR), fluctuation, skew, blowout score (BOS), blowout time (BOT), rising rate, falling rate, flow acceleration index (FAI), acceleration time index (ATI), and resistive index (RI). Two-way mixed ANOVA was used to determine the difference between every two groups where p 

    Matched MeSH terms: Optic Disk/blood supply*
  3. Raman P, Suliman NB, Zahari M, Mohamad NF, Kook MS, Ramli N
    J Glaucoma, 2019 11;28(11):952-957.
    PMID: 31688446 DOI: 10.1097/IJG.0000000000001359
    PRECIS: This 5-year follow-up study on normal-tension glaucoma (NTG) patients demonstrated that those with baseline central visual field (VF) defect progress at a more increased rate compared with those with peripheral field defect.

    PURPOSE: The purpose of this study was to investigate the clinical characteristics, including 24-hour ocular perfusion pressure and risk of progression in patients with baseline central VF defect, as compared with those with peripheral VF defect in NTG.

    DESIGN: This was a prospective, longitudinal study.

    METHODS: A total of 65 NTG patients who completed 5 years of follow-up were included in this study. All the enrolled patients underwent baseline 24-hour intraocular pressure and blood pressure monitoring via 2-hourly measurements in their habitual position and had ≥5 reliable VF tests during the 5-year follow-up. Patients were assigned to two groups on the basis of VF defect locations at baseline, the central 10 degrees, and the peripheral 10- to 24-degree area. Modified Anderson criteria were used to assess global VF progression over 5 years. Kaplan-Meier analyses were used to compare the elapsed time of confirmed VF progression in the two groups. Hazard ratios for the association between clinical risk factors and VF progression were obtained by using Cox proportional hazards models.

    RESULTS: There were no significant differences between the patients with baseline central and peripheral VF defects in terms of demography, clinical, ocular and systemic hemodynamic factors. Eyes with baseline defects involving the central fields progressed faster (difference: βcentral=-0.78 dB/y, 95% confidence interval=-0.22 to -1.33, P=0.007) and have 3.56 times higher hazard of progressing (95% confidence interval=1.17-10.82, P=0.025) than those with only peripheral defects.

    CONCLUSION: NTG patients with baseline central VF involvement are at increased risk of progression compared with those with peripheral VF defect.

    Matched MeSH terms: Optic Disk/blood supply
  4. Yip VCH, Wong HT, Yong VKY, Lim BA, Hee OK, Cheng J, et al.
    J Glaucoma, 2019 01;28(1):80-87.
    PMID: 30461553 DOI: 10.1097/IJG.0000000000001125
    AIM: To study the microvascular density of the macular and optic nerve head in healthy and glaucoma subjects using optical coherence tomography angiography.

    METHODOLOGY: We performed a cross-sectional cohort study on healthy subjects and patients with glaucoma. The AngioVue Enhanced Microvascular Imaging System was used to capture the optic nerve head and macula images during one visit. En face segment images of the macular and optic disc were studied in layers. Microvascular density of the optic nerve head and macula were quantified by the number of pixels measured by a novel in-house developed software. Areas under the receiver operating characteristic curves (AUROC) were used to determine the accuracy of differentiating between glaucoma and healthy subjects.

    RESULTS: A total of 24 (32 eyes) glaucoma subjects (57.5±9.5-y old) and 29 (58 eyes) age-matched controls (51.17±13.5-y old) were recruited. Optic disc and macula scans were performed showing a greater mean vessel density (VD) in healthy compared with glaucoma subjects. The control group had higher VD than the glaucoma group at the en face segmented layers of the optic disc (optic nerve head: 0.209±0.05 vs. 0.110±0.048, P<0.001; vitreoretinal interface: 0.086±0.045 vs. 0.052±0.034, P=0.001; radial peripapillary capillary: 0.146±0.040 vs. 0.053±0.036, P<0.001; and choroid: 0.228±0.074 vs. 0.165±0.062, P<0.001). Similarly, the VD at the macula was also greater in controls than glaucoma patients (superficial retina capillary plexus: 0.115±0.016 vs. 0.088±0.027, P<0.001; deep retina capillary plexus: 0.233±0.027 vs. 0.136±0.073, P<0.001; outer retinal capillary plexus: 0.190±0.057 vs. 0.136±0.105, P=0.036; and choriocapillaris: 0.225±0.053 vs. 0.153±0.068, P<0.001. The AUROC was highest for optic disc radial peripapillary capillary (0.96), followed by nerve head (0.92) and optic disc choroid (0.76). At the macula, the AUROC was highest for deep retina (0.86), followed by choroid (0.84), superficial retina (0.81), and outer retina (0.72).

    CONCLUSIONS: Microvascular density of the optic disc and macula in glaucoma patients was reduced compared with healthy controls. VD of both optic disc and macula had a high diagnostic ability in differentiating healthy and glaucoma eyes.

    Matched MeSH terms: Optic Disk/blood supply*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links