Displaying publications 1 - 20 of 36 in total

Abstract:
Sort:
  1. Chen LC, Low AL, Chien SF
    Appl Opt, 2004 Nov 10;43(32):5923-5.
    PMID: 15587718
    A novel fiber tapering shape, which is based on compound parabolic geometry, is proposed to increase the acceptance angle of a compound parabolic concentrator. The proposed design is described by use of ray optics on a step-index multimode fiber.
    Matched MeSH terms: Optics and Photonics
  2. Salleh MH, Glidle A, Sorel M, Reboud J, Cooper JM
    Chem Commun (Camb), 2013 Apr 18;49(30):3095-7.
    PMID: 23396529 DOI: 10.1039/c3cc38228a
    We demonstrate a polymer resonator microfluidic biosensor that overcomes the complex manufacturing procedures required to fabricate traditional devices. In this new format, we show that a gapless light coupling photonic configuration, fabricated in SU8 polymer, can achieve high sensitivity, label-free chemical sensing in solution and high sensitivity biological sensing, at visible wavelengths.
    Matched MeSH terms: Optics and Photonics
  3. Hosseini S, Ibrahim F, Djordjevic I, Koole LH
    Analyst, 2014 Jun 21;139(12):2933-43.
    PMID: 24769607 DOI: 10.1039/c3an01789c
    Biosensor chips for immune-based assay systems have been investigated for their application in early diagnostics. The development of such systems strongly depends on the effective protein immobilization on polymer substrates. In order to achieve this complex heterogeneous interaction the polymer surface must be functionalized with chemical groups that are reactive towards proteins in a way that surface functional groups (such as carboxyl, -COOH; amine, -NH2; and hydroxyl, -OH) chemically or physically anchor the proteins to the polymer platform. Since the proteins are very sensitive towards their environment and can easily lose their activity when brought in close proximity to the solid surface, effective surface functionalization and high level of control over surface chemistry present the most important steps in the fabrication of biosensors. This paper reviews recent developments in surface functionalization and preparation of polymethacrylates for protein immobilization. Due to their versatility and cost effectiveness, this particular group of plastic polymers is widely used both in research and in industry.
    Matched MeSH terms: Optics and Photonics*
  4. Youssouf AS, Hasbullah NF, Saidin N, Habaebi MH, Parthiban R, Bin Mohamed Zin MR, et al.
    PLoS One, 2021;16(12):e0259649.
    PMID: 34972119 DOI: 10.1371/journal.pone.0259649
    This paper provides the details of a study on the effects of electron radiation on the Performance of Inters-satellite Optical Wireless Communication (IsOWC). Academia and industry focus on solutions that can improve performance and reduce the cost of IsWOC systems. Spacecraft, space stations, satellites, and astronauts are exposed to an increased level of radiation when in space, so it is essential to evaluate the risks and performance effects associated with extended radiation exposures in missions and space travel in general. This investigation focuses on LEO, especially in the near-equatorial radiation environment. Radiation experiments supported with simulations have made it possible to obtain and evaluate the electron radiation impact on optoelectronics at the device level and system level performances. The electron radiation has induced a system degradation of 70%. This result demonstrates the importance of such an investigation to predict and take necessary and suitable reliable quality service for future space missions.
    Matched MeSH terms: Optics and Photonics*
  5. Yeong TJ, Pin Jern K, Yao LK, Hannan MA, Hoon STG
    Molecules, 2019 May 27;24(10).
    PMID: 31137897 DOI: 10.3390/molecules24102025
    The agricultural industry has made a tremendous contribution to the foundations of civilization. Basic essentials such as food, beverages, clothes and domestic materials are enriched by the agricultural industry. However, the traditional method in agriculture cultivation is labor-intensive and inadequate to meet the accelerating nature of human demands. This scenario raises the need to explore state-of-the-art crop cultivation and harvesting technologies. In this regard, optics and photonics technologies have proven to be effective solutions. This paper aims to present a comprehensive review of three photonic techniques, namely imaging, spectroscopy and spectral imaging, in a comparative manner for agriculture applications. Essentially, the spectral imaging technique is a robust solution which combines the benefits of both imaging and spectroscopy but faces the risk of underutilization. This review also comprehends the practicality of all three techniques by presenting existing examples in agricultural applications. Furthermore, the potential of these techniques is reviewed and critiqued by looking into agricultural activities involving palm oil, rubber, and agro-food crops. All the possible issues and challenges in implementing the photonic techniques in agriculture are given prominence with a few selective recommendations. The highlighted insights in this review will hopefully lead to an increased effort in the development of photonics applications for the future agricultural industry.
    Matched MeSH terms: Optics and Photonics*
  6. Kausar AS, Reza AW, Latef TA, Ullah MH, Karim ME
    Sensors (Basel), 2015 Apr 15;15(4):8787-831.
    PMID: 25884787 DOI: 10.3390/s150408787
    The concept of optical antennas in physical optics is still evolving. Like the antennas used in the radio frequency (RF) regime, the aspiration of optical antennas is to localize the free propagating radiation energy, and vice versa. For this purpose, optical antennas utilize the distinctive properties of metal nanostructures, which are strong plasmonic coupling elements at the optical regime. The concept of optical antennas is being advanced technologically and they are projected to be substitute devices for detection in the millimeter, infrared, and visible regimes. At present, their potential benefits in light detection, which include polarization dependency, tunability, and quick response times have been successfully demonstrated. Optical antennas also can be seen as directionally responsive elements for point detectors. This review provides an overview of the historical background of the topic, along with the basic concepts and parameters of optical antennas. One of the major parts of this review covers the use of optical antennas in biosensing, presenting biosensing applications with a broad description using different types of data. We have also mentioned the basic challenges in the path of the universal use of optical biosensors, where we have also discussed some legal matters.
    Matched MeSH terms: Optics and Photonics/methods*
  7. Amiri IS, Alavi SE, Soltanian MR, Fisal N, Supa'at AS, Ahmad H
    Sci Rep, 2015;5:11897.
    PMID: 26153536 DOI: 10.1038/srep11897
    This paper describes a novel technique to increase the numbers of access points (APs) in a wavelength division multiplexed-passive optical network (WDM-PON) integrated in a 100 GHz radio-over-fiber (RoF). Eight multi-carriers separated by 25 GHz intervals were generated in the range of 193.025 to 193.200 THz using a microring resonator (MRR) system incorporating an add-drop filter system. All optically generated multi-carriers were utilized in an integrated system of WDM-PON-RoF for transmission of four 43.6 Gb/sec orthogonal frequency division multiplexing (OFDM) signals. Results showed that an acceptable BER variation for different path lengths up to 25 km was achievable for all four access points and thus the transmission of four OFDM channels is feasible for a 25 km standard single mode fiber (SSMF) path length.
    Matched MeSH terms: Optics and Photonics
  8. Xu LL, Zhang HF, Li M, Ng SW, Feng JH, Mao JG, et al.
    J Am Chem Soc, 2018 09 19;140(37):11569-11572.
    PMID: 30141923 DOI: 10.1021/jacs.8b06725
    Chiroptical activity is observed from an achiral adenine-containing metal-organic framework (MOF) named ZnFDCA. Such a seemingly counterintuitive phenomenon can, in fact, be predicted by the intrinsic crystal symmetry of 4̅2 m point group. Although theoretically allowed, examples of optically active achiral crystals are extremely rare. ZnFDCA is the first reported achiral MOF showing optical activity, as demonstrated by a pair of circular dichroism signals with opposite signs and enhanced intensity. Moreover, simply through adding an amino substituent to adenine, the chiroptical activity, as well as nonlinear optical activity, of the analogous MOF, namely ZnFDCA-NH2, disappears due to diverse packing pattern giving rise to centrosymmetric crystal symmetry.
    Matched MeSH terms: Optics and Photonics
  9. Qazi HH, bin Mohammad AB, Akram M
    Sensors (Basel), 2012 Nov 29;12(12):16522-56.
    PMID: 23443392 DOI: 10.3390/s121216522
    Optical chemical sensors have promoted escalating interest in the determination of various pollutants in the environment, which are creating toxicity and may cause serious health problems. This review paper focuses particularly on the recent progress and developments in this field; the working principles and basic classes of optical chemical sensors have been briefly described.
    Matched MeSH terms: Optics and Photonics
  10. Hanif M, Jeoti V, Ahmad MR, Aslam MZ, Qureshi S, Stojanovic G
    Sensors (Basel), 2021 Nov 26;21(23).
    PMID: 34883867 DOI: 10.3390/s21237863
    Lately, wearable applications featuring photonic on-chip sensors are on the rise. Among many ways of controlling and/or modulating, the acousto-optic technique is seen to be a popular technique. This paper undertakes the study of different multilayer structures that can be fabricated for realizing an acousto-optic device, the objective being to obtain a high acousto-optic figure of merit (AOFM). By varying the thicknesses of the layers of these materials, several properties are discussed. The study shows that the multilayer thin film structure-based devices can give a high value of electromechanical coupling coefficient (k2) and a high AOFM as compared to the bulk piezoelectric/optical materials. The study is conducted to find the optimal normalised thickness of the multilayer structures with a material possessing the best optical and piezoelectric properties for fabricating acousto-optic devices. Based on simulations and studies of SAW propagation characteristics such as the electromechanical coupling coefficient (k2) and phase velocity (v), the acousto-optic figure of merit is calculated. The maximum value of the acousto-optic figure of merit achieved is higher than the AOFM of all the individual materials used in these layer structures. The suggested SAW device has potential application in wearable and small footprint acousto-optic devices and gives better results than those made with bulk piezoelectric materials.
    Matched MeSH terms: Optics and Photonics
  11. Yusof NA, Kadir WA
    PMID: 19010723 DOI: 10.1016/j.saa.2008.07.019
    Optical test strip based on the use of Br-PADAP as a sensitive reagent immobilised into sol-gel thin film for detection of Hg(II) in aqueous solution had been thoroughly carried out. It has a square-sensing zone (1.0 cm x 1.0 cm) containing the sensitive reagent necessary to produce response to trace level of mercury. This method offer sensitivity and simplicity in detecting Hg(II) as no prior treatment or extraction is required. A linear response was attained in the Hg(II) concentration in the range of 0.5-2.5 ppm with calculated limit of detection of 6.63 ppb. This method also showed a reproducible result with relative standard deviation (R.S.D.) of 2.15% and response time of approximately 5 min. Interference studies showed that Al(III), Co(II) and Ni(II) significantly interfered during the determination. The developed sensor has been validated against Atomic Absorption Spectroscopy method and proven comparable.
    Matched MeSH terms: Optics and Photonics/instrumentation*
  12. Damulira E, Yusoff MNS, Omar AF, Mohd Taib NH
    Sensors (Basel), 2019 May 14;19(10).
    PMID: 31091779 DOI: 10.3390/s19102226
    Numerous instruments such as ionization chambers, hand-held and pocket dosimeters of various types, film badges, thermoluminescent dosimeters (TLDs) and optically stimulated luminescence dosimeters (OSLDs) are used to measure and monitor radiation in medical applications. Of recent, photonic devices have also been adopted. This article evaluates recent research and advancements in the applications of photonic devices in medical radiation detection primarily focusing on four types; photodiodes - including light-emitting diodes (LEDs), phototransistors-including metal oxide semiconductor field effect transistors (MOSFETs), photovoltaic sensors/solar cells, and charge coupled devices/charge metal oxide semiconductors (CCD/CMOS) cameras. A comprehensive analysis of the operating principles and recent technologies of these devices is performed. Further, critical evaluation and comparison of their benefits and limitations as dosimeters is done based on the available studies. Common factors barring photonic devices from being used as radiation detectors are also discussed; with suggestions on possible solutions to overcome these barriers. Finally, the potentials of these devices and the challenges of realizing their applications as quintessential dosimeters are highlighted for future research and improvements.
    Matched MeSH terms: Optics and Photonics/trends*
  13. Ali MM, Lim KS, Yang HZ, Chong WY, Lim WS, Ahmad H
    Appl Opt, 2013 Aug 1;52(22):5393-7.
    PMID: 23913056 DOI: 10.1364/AO.52.005393
    This paper proposes an approach based on an optical imaging technique for the period measurement of fiber Bragg gratings (FBG). The simple, direct technique involves a differential interface contrast (DIC) microscope and a high-resolution CCD camera. Image processing is performed on the microscope images to obtain low-noise grating profiles and then the grating periods. Adopting a large image sample size in the image processing can reduce uncertainty. During the investigation, FBGs of different grating periods are fabricated by prestraining the photosensitive fibers during the UV-writing process. A good linearity between the measured Bragg wavelengths and grating periods is observed and the measured strain-optics coefficient was found to be in agreement with reported literature.
    Matched MeSH terms: Optics and Photonics
  14. Bahadoran M, Ali J, Yupapin PP
    Appl Opt, 2013 Apr 20;52(12):2866-73.
    PMID: 23669699 DOI: 10.1364/AO.52.002866
    In this paper, the bifurcation behavior of light in the PANDA ring resonator is investigated using the signal flow graph (SFG) method, where the optical transfer function for the through and drop ports of the PANDA Vernier system are derived. The optical nonlinear phenomena, such as bistability, Ikeda instability, and dynamics of light in the silicon-on-insulator (SOI) PANDA ring resonator with four couplers are studied. The transmission curves for bistability and instability as a function of the resonant mode numbers and coupling coefficients for the coupler are derived by the SFG method and simulated. The proposed system has an advantage as no optical pumping component is required. Simulated results show that closed-loop bistable switching can be generated and achieved by varying mode resonant numbers in the SOI-PANDA Vernier resonator, where a smooth and closed-loop bistable switching with low relative output/input power can be obtained and realized. The minimum through-port switching time of 1.1 ps for resonant mode numbers of 5;4;4 and minimum drop port switching time of 1.96 ps for resonant mode numbers of 9;7;7 of the PANDA Vernier resonator are achieved, which makes the PANDA Vernier resonator an operative component for optical applications, such as optical signal processing and a fast switching key in photonics integrated circuits.
    Matched MeSH terms: Optics and Photonics
  15. Ahmad H, Albaqawi HS, Yusoff N, Yi CW
    Sci Rep, 2020 Jun 17;10(1):9860.
    PMID: 32555280 DOI: 10.1038/s41598-020-66664-9
    A wide-band and tunable Q-switched erbium-doped fiber (EDF) laser operating at 1560.5 nm with a tungsten ditelluride (WTe2) saturable absorber (SA) is demonstrated. The semi-metallic nature of WTe2 as well as its small band gap and excellent nonlinear optical properties make it an excellent SA material. The laser cavity uses an 89.5 cm long EDF, pumped by a 980 nm laser diode as the linear gain while the WTe2 based SA generates the pulsed output. The WTe2 based SA has a modulation depth, non-saturable loss and saturation intensity of about 21.4%, 78.6%, and 0.35 kW/cm2 respectively. Stable pulses with a maximum repetition rate of 55.56 kHz, narrowest pulse width of 1.77 µs and highest pulse energy of 18.09 nJ are obtained at the maximum pump power of 244.5 mW. A 56 nm tuning range is obtained in the laser cavity, and the output is observed having a signal to noise ratio (SNR) of 48.5 dB. The demonstrated laser has potential for use in a large number of photonics applications.
    Matched MeSH terms: Optics and Photonics
  16. Suah FB, Ahmad M, Heng LY
    PMID: 25748985 DOI: 10.1016/j.saa.2015.02.068
    A novel approach for the determination of Al(3+) from aqueous samples was developed using an optode membrane produced by physical inclusion of Al(3+) selective reagent, which is morin into a plasticized poly(vinyl chloride). The inclusion of Triton X-100 was found to be valuable and useful for enhancing the sorption of Al(3+) ions from liquid phase into the membrane phase, thus increasing the intensity of optode's absorption. The optode showed a linear increase in the absorbance at λ(max)=425 nm over the concentration range of 1.85×10(-6)-1.1×10(-4) mol L(-1) (0.05-3 μg mL(-1)) of Al(3+) ions in aqueous solution after 5 min. The limit of detection was determined to be 1.04×10(-6) mol L(-1) (0.028 μg mL(-1)). The optode developed in the present work was easily prepared and found to be stable, has good mechanical strength, sensitive and reusable. In addition, the optode was tested for Al(3+) determination in lake water, river water and pharmaceutical samples, which the result was satisfactory.
    Matched MeSH terms: Optics and Photonics*
  17. Bahadoran M, Noorden AF, Chaudhary K, Mohajer FS, Aziz MS, Hashim S, et al.
    Sensors (Basel), 2014;14(7):12885-99.
    PMID: 25046015 DOI: 10.3390/s140712885
    A new photonics biosensor configuration comprising a Double-side Ring Add-drop Filter microring resonator (DR-ADF) made from SiO2-TiO2 material is proposed for the detection of Salmonella bacteria (SB) in blood. The scattering matrix method using inductive calculation is used to determine the output signal's intensities in the blood with and without presence of Salmonella. The change in refractive index due to the reaction of Salmonella bacteria with its applied antibody on the flagellin layer loaded on the sensing and detecting microresonator causes the increase in through and dropper port's intensities of the output signal which leads to the detection of SB in blood. A shift in the output signal wavelength is observed with resolution of 0.01 nm. The change in intensity and shift in wavelength is analyzed with respect to the change in the refractive index which contributes toward achieving an ultra-high sensitivity of 95,500 nm/RIU which is almost two orders higher than that of reported from single ring sensors and the limit of detection is in the order of 1 × 10(-8) RIU. In applications, such a system can be employed for a high sensitive and fast detection of bacteria.
    Matched MeSH terms: Optics and Photonics/methods
  18. Teo CL, Atta M, Bukhari A, Taisir M, Yusuf AM, Idris A
    Bioresour Technol, 2014 Jun;162:38-44.
    PMID: 24736210 DOI: 10.1016/j.biortech.2014.03.113
    Wavelength of light is a crucial factor which renders microalgae as the potential biodiesel. In this study, Tetraselmis sp. and Nannochloropsis sp. as famous targets were selected. The effect of different light wavelengths on growth rate and lipid production was studied. Microalgae were cultivated for 14 days as under blue, red, red-blue LED and white fluorescent light. The growth rate of microalgae was analyzed by spectrophotometer and cell counting while oil production under improved Nile red method. Optical density result showed the microalgae exhibited better growth curve under blue wavelength. Besides, Tetraselmis sp. and Nannochloropsis sp. under blue wavelength showed the higher growth rate (1.47 and 1.64 day(-1)) and oil production (102.954 and 702.366 a.u.). Gas chromatography analysis also showed that palmitic acid and stearic acid which were compulsory components for biodiesel contribute around 49-51% of total FAME from Nannochloropsis sp. and 81-83% of total FAME from Tetraselmis sp.
    Matched MeSH terms: Optics and Photonics*
  19. Jalil MA, Abdolkarim A, Saktioto T, Ong CT, Yupapin PP
    Int J Nanomedicine, 2012;7:773-9.
    PMID: 22359455 DOI: 10.2147/IJN.S27625
    In this study, we have generated terahertz (THz) frequency by a novel design of microring resonators for medical applications. The dense wavelength-division multiplexing can be generated and obtained by using a Gaussian pulse propagating within a modified PANDA ring resonator and an add/drop filter system. Our results show that the THz frequency region can be obtained between 40-50 THz. This area of frequency provides a reliable frequency band for THz pulsed imaging.
    Matched MeSH terms: Optics and Photonics/instrumentation*
  20. Tan C, Seet G, Sluzek A, Wang X, Yuen CT, Fam CY, et al.
    Opt Express, 2010 Sep 27;18(20):21147-54.
    PMID: 20941011 DOI: 10.1364/OE.18.021147
    The range-gated imaging systems are reliable underwater imaging system with the capability to minimize backscattering effect from turbid media. The tail-gating technique has been developed to fine tune the signal to backscattering ratio and hence improve the gated image quality. However, the tail-gating technique has limited image quality enhancement in high turbidity levels. In this paper, we developed a numerical model of range-gated underwater imaging system for near target in turbid medium. The simulation results matched the experimental work favorably. Further investigation using this numerical model shows that the multiple scattering components of the backscattering noise dominate for propagation length larger than 4.2 Attenuation Length (AL). This has limited the enhancement of tail-gating technique in high turbidity conditions.
    Matched MeSH terms: Optics and Photonics*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links