Displaying all 5 publications

Abstract:
Sort:
  1. Nazimi AJ, Khoo SC, Nabil S, Nordin R, Lan TH, Rajandram RK, et al.
    J Craniofac Surg, 2019 Oct;30(7):2159-2162.
    PMID: 31232997 DOI: 10.1097/SCS.0000000000005667
    Orbital fractures pose specific challenge in its surgical management. One of the greatest challenges is to obtain satisfactory reconstruction by correct positioning of orbital implant. Intraoperative computed tomography (CT) scan may facilitate this procedure. The aim of this study was to describe the early use of intraoperative CT in orbital fractures repair in our center. The authors assessed the revision types and rates that have occurred with this technique. With the use of pre-surgical planning, optical intraoperative navigation, and intraoperative CT, the impact of intraoperative CT on the management of 5 cases involving a total number of 14 orbital wall fractures were described. There were 6 pure orbital blowout wall fractures reconstructed, involving both medial and inferior wall of the orbit fracturing the transition zone and 8 impure orbital wall fractures in orbitozygomaticomaxillary complex fracture. 4 patients underwent primary and 1 had delayed orbital reconstruction. Intraoperative CT resulted in intraoperative orbital implant revision, following final navigation planning position, in 40% (2/5) of patients or 14% (2/14) of the fractures. In revised cases, both implant repositioning was conducted at posterior ledge of orbit. Intraoperative CT confirmed true to original reconstruction of medial wall, inferior wall and transition zone of the orbit. Two selected cases were illustrated. In conclusion, intraoperative CT allows real-time assessment of fracture reduction and immediate orbital implant revision, especially at posterior ledge. As a result, no postoperative imaging was indicated in any of the patients. Long-term follow-ups for orbital fracture patients managed with intraoperative CT is suggested.
    Matched MeSH terms: Orbital Fractures/surgery
  2. Gunarajah DR, Samman N
    J Oral Maxillofac Surg, 2013 Mar;71(3):550-70.
    PMID: 23422151 DOI: 10.1016/j.joms.2012.10.029
    To evaluate the reported use and outcomes of implant materials used for the restoration of post-traumatic orbital floor defects in adults.
    Matched MeSH terms: Orbital Fractures/surgery*
  3. Wajih WA, Shaharuddin B, Razak NH
    J Oral Maxillofac Surg, 2011 Jun;69(6):1740-4.
    PMID: 21272979 DOI: 10.1016/j.joms.2010.07.053
    A normally restored orbital structure after reconstructive surgery would accelerate the return of orbital function. The aim of the present study was to compare the outcomes of 2 orbital implants: autogenous grafts and porous polyethylene (Medpor).
    Matched MeSH terms: Orbital Fractures/surgery*
  4. Aryasit O, Ng DS, Goh ASC, Woo KI, Kim YD
    BMC Ophthalmol, 2016 Jul 07;16:94.
    PMID: 27387333 DOI: 10.1186/s12886-016-0287-0
    BACKGROUND: Porous polyethylene implants are commonly used in orbital blowout fracture repair because of purported biocompatibility, durability, and low frequency of complications. Delayed inflammation related to porous polyethylene sheet implants is very rare and no case series of this condition have been reported.

    CASE PRESENTATION: This is a retrospective review of clinical presentations, radiographic findings, histopathological findings, treatments, and outcomes of patients who developed delayed complications in orbital blowout fracture repair using porous polyethylene sheets. Four male patients were included with a mean age of 49 years (range 35-69 years). Blowout fracture repair was complicated with implant-related inflammation 10 months, 2 years, 3 years, and 8 years after surgery. Chronic and subacute orbital inflammatory signs were noted in two patients and acute fulminant orbital inflammation was found in two patients. Three patients developed peri-implant abscesses and one patient had a soft tissue mass around the implant. All patients underwent implant removal and two of these patients with paranasal sinusitis had sinus surgery. Histopathological findings revealed chronic inflammatory changes with fibrosis, and one patient had foreign body granuloma with culture positive Staphylococcus aureus.

    CONCLUSIONS: Delayed complications with porous polyethylene sheets used in orbital blowout fracture repair may occur many years following the initial surgery in immunocompetent patients. Low-grade or fulminant inflammation could complicate blowout fracture repair related with the implant.

    Matched MeSH terms: Orbital Fractures/surgery*
  5. Ali F, Halim AS, Najihah SZ, Ibrahim M, Abdullah J
    J Craniomaxillofac Surg, 2005 Oct;33(5):326-30.
    PMID: 16125400
    A vascularized outer-table calvarial bone graft was used for repairing a Posnick type 2 traumatic orbito-frontal bone defect supported by the use of a calcium-based putty (Allomatrix) in a 7-year-old girl. Gaps between the donor and recipient sites were filled with Allomatrix containing demineralized bone matrix particles. Four years later there was a good cosmetic result using an artificial left eye.
    Matched MeSH terms: Orbital Fractures/surgery*
Filters