Displaying all 2 publications

Abstract:
Sort:
  1. Wroe AJ, McAuley G, Teran AV, Wong J, Petasecca M, Lerch M, et al.
    J Appl Clin Med Phys, 2017 Sep;18(5):315-324.
    PMID: 28719019 DOI: 10.1002/acm2.12120
    As technology continues to develop, external beam radiation therapy is being employed, with increased conformity, to treat smaller targets. As this occurs, the dosimetry methods and tools employed to quantify these fields for treatment also have to evolve to provide increased spatial resolution. The team at the University of Wollongong has developed a pixelated silicon detector prototype known as the dose magnifying glass (DMG) for real-time small-field metrology. This device has been tested in photon fields and IMRT. The purpose of this work was to conduct the initial performance tests with proton radiation, using beam energies and modulations typically associated with proton radiosurgery. Depth dose and lateral beam profiles were measured and compared with those collected using a PTW parallel-plate ionization chamber, a PTW proton-specific dosimetry diode, EBT3 Gafchromic film, and Monte Carlo simulations. Measurements of the depth dose profile yielded good agreement when compared with Monte Carlo, diode and ionization chamber. Bragg peak location was measured accurately by the DMG by scanning along the depth dose profile, and the relative response of the DMG at the center of modulation was within 2.5% of that for the PTW dosimetry diode for all energy and modulation combinations tested. Real-time beam profile measurements of a 5 mm 127 MeV proton beam also yielded FWHM and FW90 within ±1 channel (0.1 mm) of the Monte Carlo and EBT3 film data across all depths tested. The DMG tested here proved to be a useful device at measuring depth dose profiles in proton therapy with a stable response across the entire proton spread-out Bragg peak. In addition, the linear array of small sensitive volumes allowed for accurate point and high spatial resolution one-dimensional profile measurements of small radiation fields in real time to be completed with minimal impact from partial volume averaging.
    Matched MeSH terms: Proton Therapy/instrumentation*
  2. Yahya N, Manan HA
    Support Care Cancer, 2021 Jun;29(6):3035-3047.
    PMID: 33040284 DOI: 10.1007/s00520-020-05808-z
    BACKGROUND: Proton therapy (PT), frequently utilised to treat paediatric brain tumour (PBT) patients, eliminates exit dose and minimises dose to healthy tissues that theoretically can mitigate treatment-related effects including cognitive deficits. As clinical outcome data are emerging, we aimed to systematically review current evidence of cognitive changes following PT of PBT.

    MATERIALS AND METHODS: We searched PubMed and Scopus electronic databases to identify eligible reports on cognitive changes following PT of PBT according to PRISMA guidelines. Reports were extracted for information on demographics and cognitive outcomes. Then, they were systematically reviewed based on three themes: (1) comparison with photon therapy, (2) comparison with baseline cognitive measures, to population normative mean or radiotherapy-naïve PBT patients and (3) effects of dose distribution to cognition.

    RESULTS: Thirteen reports (median size (range): 70 (12-144)) were included. Four reports compared the cognitive outcome between PBT patients treated with proton to photon therapy and nine compared with baseline/normative mean/radiotherapy naïve from which two reported the effects of dose distribution. Reports found significantly poorer cognitive outcome among patients treated with photon therapy compared with proton therapy especially in general cognition and working memory. Craniospinal irradiation (CSI) was consistently associated with poorer cognitive outcome while focal therapy was associated with minor cognitive change/difference. In limited reports available, higher doses to the hippocampus and temporal lobes were implicated to larger cognitive change.

    CONCLUSION: Available evidence suggests that PT causes less cognitive deficits compared with photon therapy. Children who underwent focal therapy with proton were consistently shown to have low risk of cognitive deficit suggesting the need for future studies to separate them from CSI. Evidence on the effect of dose distribution to cognition in PT is yet to mature.

    Matched MeSH terms: Proton Therapy