Displaying all 11 publications

Abstract:
Sort:
  1. Hor, S.M., Noor Aniah, A., Mushawiahti, M., Mushawiahti, M., Bastion, M.L.C.
    MyJurnal
    Scleral buckle placement is a well-established technique for the treatment of primary rhegmatogenous retinal
    detachment. Complications associated with scleral buckle are uncommon and its presentations can be vary. We
    report a case of recurrent orbital cellulitis with anterior segment ischemia following a forgotten episode of previous
    scleral buckling surgery, presenting with blurring of vision, redness and swelling of the lids. The presence of scleral
    buckle was detected by detailed examination and confirmed by orbital imaging. Orbital infection and rubeosis iridis
    were successfully treated with scleral buckle removal, intravenous antibiotics and intracameral ranibizumab.
    However, the retinal detachment recurred and the visual acuity deteriorated to light perception. There was no further
    intervention as the family declined in view of her old age. In cases of recurrent orbital infection, detailed clinical
    examination is important to look for evidence of ocular prostheses as a source of infection. Orbital imaging is an
    adjunct for making the diagnosis especially in cases where history is unreliable. Anterior segment ischemia due to
    scleral buckle responds well to buckle removal with ranibizumab injection.
    Matched MeSH terms: Sclera; Scleral Buckling
  2. Samsudin A, Eames I, Brocchini S, Khaw PT
    J Glaucoma, 2016 07;25(7):e704-12.
    PMID: 26561421 DOI: 10.1097/IJG.0000000000000360
    PURPOSE: Intraocular pressure and aqueous humor flow direction determined by the scleral flap immediately after trabeculectomy are critical determinants of the surgical outcome. We used a large-scale model to objectively measure the influence of flap thickness and shape, and suture number and position on pressure difference across the flap and flow of fluid underneath it.

    METHODS: The model exploits the principle of dynamic and geometric similarity, so while dimensions were up to 30× greater than actual, the flow had similar properties. Scleral flaps were represented by transparent 0.8- and 1.6-mm-thick silicone sheets on an acrylic plate. Dyed 98% glycerin, representing the aqueous humor was pumped between the sheet and plate, and the equilibrium pressure measured with a pressure transducer. Image analysis based on the principle of dye dilution was performed using MATLAB software.

    RESULTS: The pressure drop across the flap was larger with thinner flaps, due to reduced rigidity and resistance. Doubling the surface area of flaps and reducing the number of sutures from 5 to 3 or 2 also resulted in larger pressure drops. Flow direction was affected mainly by suture number and position, it was less toward the sutures and more toward the nearest free edge of the flap. Posterior flow of aqueous humor was promoted by placing sutures along the sides while leaving the posterior edge free.

    CONCLUSION: We demonstrate a new physical model which shows how changes in scleral flap thickness and shape, and suture number and position affect pressure and flow in a trabeculectomy.

    Matched MeSH terms: Sclera/pathology*
  3. Loh, Ui Lyn, Nadras, Indira, Yeong, Choo Mee, Nadarajah, Gaayathri, Fazilawati Qamarruddin, Shelina Oli Mohamed, et al.
    MyJurnal
    Tuberculosis, an ancient disease, still thrives today as the leading infection caused by Mycobacterium tuberculosis. Diagnosis of ocular tuberculosis poses a great challenge due to the varied clinical presentations. We report 3 cases of primary ocular tuberculosis with varied presentations: conjunctival abscess, sclera-uveitis and occlusive vasculitis. There were no symptoms suggestive of pulmonary tuberculosis in all cases. All patients presented with acute, unilateral painful red eye. The first case had good visual acuity (VA) OD (6/9) with a swollen upper lid, localized perilimbal-hemorrhagic conjunctival swelling superiorly, keratic precipitates and mild anterior chamber reaction. The posterior segment was normal. The second case had a VA of 6/60 OD. There was presence of conjunctival injection, keratic precipitates, posterior synechiae and anterior chamber reaction of 1+. A few days later, there was a progression to vitritis OU and hyperemic optic disc OD with choroidal folds, cystoid macula edema and a positive T sign on B scan ultrasonography. The third case had VA of 6/6 OU, AC reaction of 2+ OD. There was multiple peripheral choroiditis with peripheral vasculitis seen in the posterior segment OU. Fundus fluorescein angiography (FFA) showed peripheral periphlebitis in all 4 quadrants OU. All 3 cases had positive Tuberculin Skin Test (Mantoux test) results which were more than 20mm. Anti-tuberculous treatment was promptly started and all patients showed significant clinical improvement. This case series highlights the diverse clinical presentations of ocular tuberculosis. A high clinical index of suspicion led to prompt initiation of anti-tuberculous therapy which resulted in good clinical outcomes for all cases.
    Matched MeSH terms: Sclera
  4. Ooi, Edwin I.L., Safinaz, M.K., Ropilah, A.R
    MyJurnal
    This was a 28-year-old mentally-challenged girl with underlying congenital Rubella syndrome. She was bilaterally aphakic after congenital cataract surgery. She then developed bilateral aphakic glaucoma and had to undergo multiple glaucoma filtering surgeries. The most recent procedure she had undergone for her left eye was a second Ahmed valve implantation with an overlying sclera patch. Postoperatively, intraocular pressure was well controlled. However, nine months later, slit lamp examination revealed the tube was adherent to the overlying cornea with surrounding deep and superficial cornea vascularization. Siedel test was negative and intraocular pressure was normal. Subsequently the tube was removed but the plate was left in situ.
    Matched MeSH terms: Sclera
  5. Lautrup CK, Teik KW, Unzaki A, Mizumoto S, Syx D, Sin HH, et al.
    Mol Genet Genomic Med, 2020 05;8(5):e1197.
    PMID: 32130795 DOI: 10.1002/mgg3.1197
    BACKGROUND: Musculocontractural Ehlers-Danlos Syndrome (mcEDS) is a rare connective tissue disorder caused by biallelic loss-of-function variants in CHST14 (mcEDS-CHST14) or DSE (mcEDS-DSE), both of which result in defective dermatan sulfate biosynthesis. Forty-one patients with mcEDS-CHST14 and three patients with mcEDS-DSE have been described in the literature.

    METHODS: Clinical, molecular, and glycobiological findings in three additional patients with mcEDS-DSE were investigated.

    RESULTS: Three patients from two families shared craniofacial characteristics (hypertelorism, blue sclera, midfacial hypoplasia), skeletal features (pectus and spinal deformities, characteristic finger shapes, progressive talipes deformities), skin features (fine or acrogeria-like palmar creases), and ocular refractive errors. Homozygous pathogenic variants in DSE were found: c.960T>A/p.Tyr320* in patient 1 and c.996dupT/p.Val333Cysfs*4 in patients 2 and 3. No dermatan sulfate was detected in the urine sample from patient 1, suggesting a complete depletion of DS.

    CONCLUSION: McEDS-DSE is a congenital multisystem disorder with progressive symptoms involving craniofacial, skeletal, cutaneous, and cardiovascular systems, similar to the symptoms of mcEDS-CHST14. However, the burden of symptoms seems lower in patients with mcEDS-DSE.

    Matched MeSH terms: Sclera
  6. Wahid WA, Selvaraja V, Bakiah S, Ibrahim M
    Cornea, 2008 Aug;27(7):837-9.
    PMID: 18650673 DOI: 10.1097/ICO.0b013e318169d6cc
    To describe recurrent peripheral ulcerative keratitis (PUK) on the corneoscleral graft in a young man treated successfully with oral corticosteroids.
    Matched MeSH terms: Sclera/transplantation*
  7. Samsudin A, Eames I, Brocchini S, Khaw PT
    J Glaucoma, 2016 Jan;25(1):e39-45.
    PMID: 25719236 DOI: 10.1097/IJG.0000000000000243
    PURPOSE: ExPress devices are available as P50 and P200 models, the numbers related to their luminal diameters in μm. We compared their Poiseuille's Law-based theoretical resistance values with experimental values and correlated these with their luminal dimensions derived from electron microscopy.

    METHODS: Scanning electron microscopy was performed on P50 and P200 devices. Bench-top flow studies were performed to find the resistances of the devices. Devices were also incorporated into a perfused, ex vivo porcine sclera model to test and compare their control of pressure, with and without overlying scleral flaps, and with trabeculectomies.

    RESULTS: The luminal dimensions of the P200 device were 206.4±3.3 and 204.5±0.9 μm at the subconjunctival space and anterior chamber ends, respectively. Those of the P50 device were 205.0±5.8 and 206.9±3.7 μm, respectively. There were no significant differences between the P200 and P50 devices (all P>0.05). The resistances of the P200 and P50 devices were 0.010±0.001 and 0.054±0.002 mm Hg/μL/min, respectively (P<0.05). Equilibrium pressures with overlying scleral flaps were 17.81±3.30 mm Hg for the P50, 17.31±4.24 mm Hg for the P200, and 16.28±6.67 mm Hg for trabeculectomies (P=0.850).

    CONCLUSIONS: The luminal diameters of both devices are externally similar. The effective luminal diameter of the P50 is much larger than 50 μm. Both devices have low resistance values, making them unlikely to prevent hypotony on their own. They lead to similar equilibrium pressures as the trabeculectomy procedure when inserted under the scleral flap.

    Matched MeSH terms: Sclera
  8. Tan SY, Md Din N, Mohd Khialdin S, Wan Abdul Halim WH, Tang SF
    Cureus, 2021 Feb 12;13(2):e13320.
    PMID: 33738163 DOI: 10.7759/cureus.13320
    The hazy corneal donor-recipient interface after corneal transplant may cause difficulties when implanting the XEN gel stent via ab-interno approach. We aim to describe XEN gel stent implantation via ab-externo approach in refractory steroid-induced glaucoma after corneal lamellar keratoplasty. Under local anaesthesia, the XEN injector needle was inserted 7 mm behind the limbus with the bevel facing up, directly beneath the conjunctiva and advanced to the marked 2.5 mm scleral entry wound. The needle then pierced the sclera until the needle tip was just visible in the anterior chamber (AC). The slider was pushed until the tip of the XEN stent was seen in the AC. The needle was slowly withdrawn while still pushing the slider to complete stent deployment. Subconjunctival Mitomycin C 0.01% (30 µg/0.3 mL) was then injected posterior to the bleb. Three eyes of three patients with steroid-induced glaucoma after lamellar keratoplasty underwent XEN gel stent implantation via ab-externo approach placed at the superotemporal quadrant. Pre-operatively, all patients had uncontrolled IOP between 30-45 mmHg despite maximum medications and selective laser trabeculoplasty. After XEN gel stent implantation, IOP ranged between 10-17 mmHg with one or two topical antiglaucoma at 12 months. Complications include hypotony maculopathy, stent migration and hyphaema, all of which were successfully managed. Corneal graft remained clear at 12 months. XEN gel stent implantation via ab-externo approach is able to achieve good intraocular pressure (IOP) control without compromising cornea graft in patients with steroid-induced glaucoma after lamellar keratoplasty at 12 months.
    Matched MeSH terms: Sclera
  9. Khairidzan, M.K., Fatimah, S.S., Thangasamy, V.K.
    MyJurnal
    Pterygium is a common external eye problem. It is more frequently seen in tropical areas regions where exposure to ultraviolet sunlight is high. Clinically, a pterygium is a wing shaped fibrovascular growth arising from the bulbar conjunctiva onto the superficial cornea. Complications of pterygium include decreased in visual acuity, dryness, foreign body sensation and persistent redness. Surgical management is the mainstay of treatment for this condition. Numerous surgical techniques have been described in the treatment of pterygium. They include the bare sclera technique, simple direct conjunctival closure, rotational conjunctival graft and conjunctival autograft. Additional treatment to some of these techniques may include the use of beta particle therapy and antimetabolite therapy. Despite the wide range of surgical procedures described for its treatment, the main concern from these procedures has been the recurrence, which could be as high as 30% to 70%. Recurrent pterygium is often accompanied by increased conjunctival inflammation and accelerated corneal involvement. Repeated surgical procedures often only worsen the situation, as loss of conjunctival tissue and scarring can result in obliteration of the fornices and mechanical restriction of extraocular movements, with clinically significant diplopia. In Hospital Tengku Ampuan Afzan, pterygium excision is the most common surgical procedure after cataract extraction. We reviewed patients who had undergone pterygium surgery in HTAA in order to determine the most effective surgical method that could minimize recurrence. PURPOSE: To compare success rates of various excision techniques performed for primary and recurrent pterygium in Hospital Tengku Ampuan Afzan, Kuantan, Pahang.
    METHODS: The outcome of 47 cases of pterygia (44 primary and 3 recurrent) excised with various techniques between January 2004 to September 2004 was retrospectively reviewed. Six clinical specialists and four trainees performed the surgical procedures. Outcome was evaluated in terms of recurrence of pterygia onto the cornea. RESULTS: The mean follow up was 3.04 months (range, 1-7 months). All pterygia were morphologically graded as intermediate or fleshy type except one. Four types of pterygium excision techniques were performed. Twenty-four cases had bare sclera, seventeen cases had conjunctival autograft transplantation, six cases had direct conjunctival closure and one had amniotic membrane transplantation done. Recurrence of pterygia occurred in thirteen eyes. Twelve cases from primary pterygia group and one case from recurrent group recurred. Recurrence rate was noted to be higher in direct conjunctival closure (4 out of 6 cases) and lowest in conjunctival autograft transplantation (2 out of 17 cases). Recurrence rate for bare sclera technique was noted to rank second in this study (6 out of 24 cases). In five cases of recurrence, subconjunctival tissue invasions were more than 1 mm but further surgical interventions were not needed at the time of this review was done. CONCLUSIONS: Conjunctival autografting was found to have less recurrent rate when compared with other techniques. The bare sclera technique was quoted to be associated with higher recurrence rate in other literatures. Interestingly in our series, recurrence rate for direct conjunctival closure technique was higher when compared to the former technique. This may be related to inadequate excision of pterygia tissue, which led to direct apposition of abnormal tissue to the cornea in the direct conjunctival closure technique. Even though the bare sclera technique is associated with a higher recurrence rate, it is still the preferred excision technique. This could be because it is less time consuming and technically easier to perform. Based on this study, conjunctival autografting should be the surgical procedure of choice for pteryigum in order to minimise the risk of recurrence.
    Matched MeSH terms: Sclera
  10. Wong EY, Chew PT, Chee CK, Wong JS
    Am J Ophthalmol, 1997 Dec;124(6):797-804.
    PMID: 9402826
    PURPOSE: To evaluate the effectiveness and safety of diode laser contact transscleral cyclophotocoagulation in Asian patients with refractory glaucoma by lower energy settings with an innovative probe featuring a glass ball tip that focused the laser beam onto the ciliary body.

    METHODS: This prospective clinical study included consecutive Asian patients with dark irides and confirmed for glaucoma. Only one eye of each patient was treated. Diode laser contact transscleral cyclophotocoagulation treatment was performed with the center of the probe placed 1.5 mm behind the limbus. About 30 pulses of 810-mm laser radiation (power, 1.8 to 2.0 W; duration, 0.3 to 0.5 second) were applied around the eye. Patients were examined at fixed postoperative intervals. Intraocular pressure levels and postoperative complications were recorded. The relation between patient and disease characteristics, total laser energy delivered, and intraocular pressure effects were analyzed.

    RESULTS: Thirty-three patients were studied, with a mean follow-up period of 9.4 months. An average 56% of patients showed a 30% or greater drop in intraocular pressure. About 38% of patients achieved sustained intraocular pressure lowering to below 22 mm Hg at 18 months. Complications were few and included transient hypotony and iritis.

    CONCLUSIONS: In Asian patients with refractory glaucoma or painful glaucomatous eyes with poor visual acuity (defined for this study as worse than 20/200), low-energy-setting diode laser contact transscleral cyclophotocoagulation by means of the glass ball probe is relatively effective and safe.

    Matched MeSH terms: Sclera
  11. Weerekoon L
    Br J Ophthalmol, 1972 Feb;56(2):106-13.
    PMID: 5010311
    Matched MeSH terms: Sclera
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links