Displaying publications 1 - 20 of 213 in total

Abstract:
Sort:
  1. Wei Y, Wang D, Li G, Yu H, Dong X, Jiang H
    Water Sci Technol, 2023 Nov;88(10):2566-2580.
    PMID: 38017678 DOI: 10.2166/wst.2023.365
    In recent years, chemical water treatment equipment has gained significant attention due to its environmental-friendly features, multifunctionality, and broad applicability. Recognizing the limitations of existing chemical treatment equipment, such as challenges in scale removal and the high water content in scale deposits, we propose a novel drum design for both anode and cathode, enabling simultaneous scale suction and dehydration. We constructed a small experimental platform to validate the equipment's performance based on our model. Notably, under the optimal operating parameters, the hardness removal rate for circulating water falls within the range of 19.6-24.46%. Moreover, the scale accumulation rate per unit area and unit time reaches 13.7 g h-1 m-2. Additionally, the energy consumption per unit weight of the scale remains impressively low at 0.16 kWh g-1. Furthermore, the chemical oxygen demand (COD) concentration decreased from an initial 106.0 mg L-1 to a mere 18.8 mg L-1, resulting in a remarkable total removal rate of 82.26%. In conclusion, our innovative electrochemical water treatment equipment demonstrates exceptional performance in scale removal, organic matter degradation, and water resource conservation, offering valuable insights for future research and development in chemical treatment equipment and electrochemical theory.
    Matched MeSH terms: Waste Disposal, Fluid/methods
  2. Show KY, Mao T, Lee DJ
    Water Res, 2007 Dec;41(20):4741-7.
    PMID: 17688907
    This study presents an examination on the correlation of sonication operating condition, sludge property, formation and behaviour of cavitation bubbles in sludge disruption under low-frequency ultrasound sonication. The influence of sonication time, sonication density, type of sludge and solids content on the disruption was evaluated. The most vigorous particle disruption was achieved in the initial period of sonication, which subsided subsequently. The explosive effect was likely due to the rapid cavitation arising from powerful transient bubbles generated in fractions of microseconds. A rating for the type of sludge was derived based on the finding that particles in secondary sludge were more readily disrupted than both primary sludge and mixed sludge. While sonication density exhibited the most significant role in cavitation bubble formation and behaviour, particle disruption could be optimised for energy input by sonicating at higher sonication density and shorter sonication time. Based on theoretical consideration, it was deduced that within an optimum sludge solids content ranging between 2.3% and 3.2%, superior particle disruption could be accomplished within a minute for secondary sludge sonicated at a density of 0.52 W/mL. Useful guidelines for sonication system installation, equipment protection and process reliability could be established from knowledge derived from a good understanding on the influence of solids content on sludge sonication.
    Matched MeSH terms: Waste Disposal, Fluid/methods*
  3. Rosman NH, Nor Anuar A, Chelliapan S, Md Din MF, Ujang Z
    Bioresour Technol, 2014 Jun;161:155-61.
    PMID: 24704837 DOI: 10.1016/j.biortech.2014.03.047
    The influence of hydraulic retention time (HRT, 24, 12, and 6h) on the physical characteristics of granules and performance of a sequencing batch reactor (SBR) treating rubber wastewater was investigated. Results showed larger granular sludge formation at HRT of 6h with a mean size of 2.0±0.1mm, sludge volume index of 20.1mLg(-1), settling velocity of 61mh(-1), density of 78.2gL(-1) and integrity coefficient of 9.54. Scanning electron microscope analyses revealed different morphology of microorganisms and structural features of granules when operated at various HRT. The results also demonstrated that up to 98.4% COD reduction was achieved when the reactor was operated at low HRT (6h). Around 92.7% and 89.5% removal efficiency was noted for ammonia and total nitrogen in the granular SBR system during the treatment of rubber wastewater.
    Matched MeSH terms: Waste Disposal, Fluid/methods*
  4. Alkarkhi AF, Lim HK, Yusup Y, Teng TT, Abu Bakar MA, Cheah KS
    J Environ Manage, 2013 Jun 15;122:121-9.
    PMID: 23570974 DOI: 10.1016/j.jenvman.2013.03.010
    The ability of aluminum coagulant extracted from red earth to treat Terasil Red R (disperse) and Cibacron Red R (reactive) synthetic dye wastewater was studied. The effects of extractant concentration, soil-to-volume of extractant ratio, and the types of extracting agents (NaOH vs. KCl) on the concentration of aluminum extracted were also investigated. In addition, the efficiency of extracted aluminum was compared with aluminum sulfate, in terms of its capability to reduce the chemical oxygen demand (COD) and to remove synthetic color. Factorial design was applied to determine the effect of selected factors on the amount of aluminum extracted from red earth (i.e., pH, dose of coagulant, type of coagulant on COD reduction, and color removal). It was found that only selected factors exhibited a significant effect on the amount of aluminum extracted from red earth. It was also determined that all factors and their interactions exhibited a significant effect on COD reduction and color removal when applying the extracted aluminum in a standard coagulation process. The results were also compared to aluminum sulfate. Furthermore, NaOH was found to be a better extractant of aluminum in red earth than KCl. Therefore, the best extracting conditions for both extractants were as follows: 2 M NaOH and in a 1:5 (soil/volume of extractant) ratio; 1 M KCl and 1:5 ratio. In treating synthetic dye wastewater, the extracted coagulant showed comparable treatment efficiency to the commercial coagulant. The extracted coagulant was able to reduce the COD of the dispersed dye by 85% and to remove 99% of the color of the dispersed dye, whereas the commercial coagulant reduced 90% of the COD and removed 99% of the color of the dispersed dye. Additionally, the extracted coagulant was able to reduce the COD of the reactive dye by 73% and to remove 99% of the color of the reactive dye. However, the commercial coagulant managed to reduce the COD of the reactive dye by 94% and to remove 96% of the color for the reactive dye.
    Matched MeSH terms: Waste Disposal, Fluid/methods*
  5. Naje AS, Ajeel MA, Ali IM, Al-Zubaidi HAM, Alaba PA
    Water Sci Technol, 2019 Aug;80(3):458-465.
    PMID: 31596257 DOI: 10.2166/wst.2019.289
    In this work, landfill leachate treatment by electrocoagulation process with a novel rotating anode reactor was studied. The influence of rotating anode speed on the removal efficiency of chemical oxygen demand (COD), total dissolved solids (TDS), and total suspended solids (TSS) of raw landfill leachate was investigated. The influence of operating parameters like leachate pH, leachate temperature, current, and inter-distance between the cathode rings and anode impellers on the electrocoagulation performance were also investigated. The results revealed the optimum rotating speed is 150 rpm and increasing the rotating speed above this value led to reducing process performance. The leachate electrocoagulation treatment process favors the neutral medium and the treatment performance increases with increasing current intensity. Furthermore, the electrocoagulation treatment performance improves with increasing leachate temperature. However, the performance reduces with increasing inter-electrode distance.
    Matched MeSH terms: Waste Disposal, Fluid/methods*
  6. Wang Y, Zhao Y, Xu L, Wang W, Doherty L, Tang C, et al.
    Water Sci Technol, 2017 Jul;76(2):471-477.
    PMID: 28726712 DOI: 10.2166/wst.2017.190
    In the last 10 years, the microbial fuel cell (MFC) has been extensively studied worldwide to extract energy from wastewater via electricity generation. More recently, a merged technique of embedding MFC into a constructed wetland (CW) has been developed and appears to be increasingly investigated. The driving force to integrate these two technologies lies in the fact that CWs naturally possess a redox gradient (depending on flow direction and wetland depth), which is required by MFCs as anaerobic anode and aerobic cathode chambers. No doubt, the integration of MFC with a CW will upgrade the CW to allow it to be used for wastewater treatment and, simultaneously, electricity generation, making CWs more sustainable and environmentally friendly. Currently, published work shows that India, China, Ireland, Spain, Germany and Malaysia are involved in the development of this technology although it is in its infant stage and many technical issues are faced on system configuration, operation and maximisation of electricity production. This paper aims to provide an updated review and analysis of the CW-MFC development. Focuses are placed on the experience gained so far from different researchers in the literature and further research directions and proposals are discussed in great detail.
    Matched MeSH terms: Waste Disposal, Fluid/methods*
  7. Wurochekke AA, Mohamed RM, Al-Gheethi AA, Atiku H, Amir HM, Matias-Peralta HM
    J Water Health, 2016 Dec;14(6):914-928.
    PMID: 27959870
    Discharge of household greywater into water bodies can lead to an increase in contamination levels in terms of the reduction in dissolved oxygen resources and rapid bacterial growth. Therefore, the quality of greywater has to be improved before the disposal process. The present review aimed to present a hybrid treatment system for the greywater generated from households. The hybrid system comprised a primary stage (a natural filtration unit) with a bioreactor system as the secondary treatment combined with microalgae for greywater treatment, as well as the natural flocculation process. The review discussed the efficiency of each stage in the removal of elements and nutrients. The hybrid system reviewed here represented an effective solution for the remediation of household greywater.
    Matched MeSH terms: Waste Disposal, Fluid/methods*
  8. Som AM, Ramlee AA, Puasa SW, Hamid HAA
    Environ Sci Pollut Res Int, 2023 Feb;30(7):17108-17121.
    PMID: 34841489 DOI: 10.1007/s11356-021-17633-w
    In exploring the application of natural coagulants in industrial wastewater treatment, plant-based coagulants have been gaining more interests due to their potential such as biodegradability and easy availability. Hylocereus undatus foliage as a plant-based coagulant has been proven to be efficient during the coagulation-flocculation process; however, limited research has been reported focusing only on palm oil mill effluent (POME) and latex concentrate wastewater. In addition, no previous study has been carried out to determine the performance evaluation of Hylocereus undatus foliage in treating different types of wastewater incorporating different operating conditions using optimization techniques. Hence, this study employed response surface methodology (RSM) in an attempt to determine the performance evaluation of the coagulant in paint wastewater treatment. Four independent factors such as the pH value, coagulant dosage, rapid mixing speed and temperature were chosen as the operating conditions. Three water parameters such as turbidity, chemical oxygen demand (COD) and suspended solids (SS) were chosen as responses in this study. Results revealed that through central composite design (CCD) via Design Expert software, the optimum conditions were achieved at pH 5, coagulant dosage of 300 mg/L, rapid mixing speed of 120 rpm and temperature at 30 °C. The experimental data was observed to be close to the model predictions with the optimum turbidity, COD and SS removal efficiencies found to be at 62.81%, 59.57% and 57.23%, respectively.
    Matched MeSH terms: Waste Disposal, Fluid/methods
  9. Sharuddin SS, Ramli N, Yusoff MZM, Muhammad NAN, Ho LS, Maeda T
    J Appl Microbiol, 2023 Oct 04;134(10).
    PMID: 37757470 DOI: 10.1093/jambio/lxad219
    AIMS: This study aimed to investigate the effect of palm oil mill effluent (POME) final discharge on the active bacterial composition, gene expression, and metabolite profiles in the receiving rivers to establish a foundation for identifying potential biomarkers for monitoring POME pollution in rivers.

    METHODS AND RESULTS: The POME final discharge, upstream (unpolluted by POME), and downstream (effluent receiving point) parts of the rivers from two sites were physicochemically characterized. The taxonomic and gene profiles were then evaluated using de novo metatranscriptomics, while the metabolites were detected using qualitative metabolomics. A similar bacterial community structure in the POME final discharge samples from both sites was recorded, but their composition varied. Redundancy analysis showed that several families, particularly Comamonadaceae and Burkholderiaceae [Pr(>F) = 0.028], were positively correlated with biochemical oxygen demand (BOD5) and chemical oxygen demand (COD). The results also showed significant enrichment of genes regulating various metabolisms in the POME-receiving rivers, with methane, carbon fixation pathway, and amino acids among the predominant metabolisms identified (FDR  4, and PPDE > 0.95). This was further validated through qualitative metabolomics, whereby amino acids were detected as the predominant metabolites.

    CONCLUSIONS: The results suggest that genes regulating amino acid metabolism have significant potential for developing effective biomonitoring and bioremediation strategies in river water influenced by POME final discharge, fostering a sustainable palm oil industry.

    Matched MeSH terms: Waste Disposal, Fluid/methods
  10. Asrami MR, Pirouzi A, Nosrati M, Hajipour A, Zahmatkesh S
    Chemosphere, 2024 Jan;347:140652.
    PMID: 37967679 DOI: 10.1016/j.chemosphere.2023.140652
    Although algal-based membrane bioreactors (AMBRs) have been demonstrated to be effective in treating wastewater (landfill leachate), there needs to be more research into the effectiveness of these systems. This study aims to determine whether AMBR is effective in treating landfill leachate with hydraulic retention times (HRTs) of 8, 12, 14, 16, 21, and 24 h to maximize AMBR's energy efficiency, microalgal biomass production, and removal efficiency using artificial neural network (ANN) models. Experimental results and simulations indicate that biomass production in bioreactors depends heavily on HRT. A decrease in HRT increases algal (Chlorella vulgaris) biomass productivity. Results also showed that 80% of chemical oxygen demand (COD) was removed from algal biomass by bioreactors. To determine the most efficient way to process the features as mentioned above, nondominated sorting genetic algorithm II (NSGA-II) techniques were applied. A mesophilic, suspended-thermophilic, and attached-thermophilic organic loading rate (OLR) of 1.28, 1.06, and 2 kg/m3/day was obtained for each method. Compared to suspended-thermophilic growth (3.43 kg/m3.day) and mesophilic growth (1.28 kg/m3.day), attached-thermophilic growth has a critical loading rate of 10.5 kg/m3.day. An energy audit and an assessment of the system's auto-thermality were performed at the end of the calculation using the Monod equation for biomass production rate (Y) and bacteria death constant (Kd). According to the results, a high removal level of COD (at least 4000 mg COD/liter) leads to auto-thermality.
    Matched MeSH terms: Waste Disposal, Fluid/methods
  11. Khan MB, Lee XY, Nisar H, Ng CA, Yeap KH, Malik AS
    Adv Exp Med Biol, 2015;823:227-48.
    PMID: 25381111 DOI: 10.1007/978-3-319-10984-8_13
    Activated sludge system is generally used in wastewater treatment plants for processing domestic influent. Conventionally the activated sludge wastewater treatment is monitored by measuring physico-chemical parameters like total suspended solids (TSSol), sludge volume index (SVI) and chemical oxygen demand (COD) etc. For the measurement, tests are conducted in the laboratory, which take many hours to give the final measurement. Digital image processing and analysis offers a better alternative not only to monitor and characterize the current state of activated sludge but also to predict the future state. The characterization by image processing and analysis is done by correlating the time evolution of parameters extracted by image analysis of floc and filaments with the physico-chemical parameters. This chapter briefly reviews the activated sludge wastewater treatment; and, procedures of image acquisition, preprocessing, segmentation and analysis in the specific context of activated sludge wastewater treatment. In the latter part additional procedures like z-stacking, image stitching are introduced for wastewater image preprocessing, which are not previously used in the context of activated sludge. Different preprocessing and segmentation techniques are proposed, along with the survey of imaging procedures reported in the literature. Finally the image analysis based morphological parameters and correlation of the parameters with regard to monitoring and prediction of activated sludge are discussed. Hence it is observed that image analysis can play a very useful role in the monitoring of activated sludge wastewater treatment plants.
    Matched MeSH terms: Waste Disposal, Fluid/methods*
  12. Chun TS, Malek MA, Ismail AR
    Water Sci Technol, 2015;71(4):524-8.
    PMID: 25746643 DOI: 10.2166/wst.2014.451
    The development of effluent removal prediction is crucial in providing a planning tool necessary for the future development and the construction of a septic sludge treatment plant (SSTP), especially in the developing countries. In order to investigate the expected functionality of the required standard, the prediction of the effluent quality, namely biological oxygen demand, chemical oxygen demand and total suspended solid of an SSTP was modelled using an artificial intelligence approach. In this paper, we adopt the clonal selection algorithm (CSA) to set up a prediction model, with a well-established method - namely the least-square support vector machine (LS-SVM) as a baseline model. The test results of the case study showed that the prediction of the CSA-based SSTP model worked well and provided model performance as satisfactory as the LS-SVM model. The CSA approach shows that fewer control and training parameters are required for model simulation as compared with the LS-SVM approach. The ability of a CSA approach in resolving limited data samples, non-linear sample function and multidimensional pattern recognition makes it a powerful tool in modelling the prediction of effluent removals in an SSTP.
    Matched MeSH terms: Waste Disposal, Fluid/methods*
  13. Tisa F, Abdul Raman AA, Wan Daud WMA
    J Environ Manage, 2014 Dec 15;146:260-275.
    PMID: 25190594 DOI: 10.1016/j.jenvman.2014.07.032
    Treatment of industrial waste water (e.g. textile waste water, phenol waste water, pharmaceutical etc) faces limitation in conventional treatment procedures. Advanced oxidation processes (AOPs) do not suffer from the limits of conventional treatment processes and consequently degrade toxic pollutants more efficiently. Complexity is faced in eradicating the restrictions of AOPs such as sludge formation, toxic intermediates formation and high requirement for oxidants. Increased mass-transfer in AOPs is an alternate solution to this problem. AOPs combined with Fluidized bed reactor (FBR) can be a potential choice compared to fixed bed or moving bed reactor, as AOP catalysts life-span last for only maximum of 5-10 cycles. Hence, FBR-AOPs require lesser operational and maintenance cost by reducing material resources. The time required for AOP can be minimized using FBR and also treatable working volume can be increased. FBR-AOP can process from 1 to 10 L of volume which is 10 times more than simple batch reaction. The mass transfer is higher thus the reaction time is lesser. For having increased mass transfer sludge production can be successfully avoided. The review study suggests that, optimum particle size, catalyst to reactor volume ratio, catalyst diameter and liquid or gas velocity is required for efficient FBR-AOP systems. However, FBR-AOPs are still under lab-scale investigation and for industrial application cost study is needed. Cost of FBR-AOPs highly depends on energy density needed and the mechanism of degradation of the pollutant. The cost of waste water treatment containing azo dyes was found to be US$ 50 to US$ 500 per 1000 gallons where, the cost for treating phenol water was US$ 50 to US$ 800 per 1000 gallons. The analysis for FBR-AOP costs has been found to depend on the targeted pollutant, degradation mechanism (zero order, 1st order and 2nd order) and energy consumptions by the AOPs.
    Matched MeSH terms: Waste Disposal, Fluid/methods
  14. Chun TS, Malek MA, Ismail AR
    Environ Sci Process Impacts, 2014 Sep 20;16(9):2208-14.
    PMID: 25005632 DOI: 10.1039/c4em00282b
    Effluent discharge from septic tanks is affecting the environment in developing countries. The most challenging issue facing these countries is the cost of inadequate sanitation, which includes significant economic, social, and environmental burdens. Although most sanitation facilities are evaluated based on their immediate costs and benefits, their long-term performance should also be investigated. In this study, effluent quality-namely, the biological oxygen demand (BOD), chemical oxygen demand (COD), and total suspended solid (TSS)-was assessed using a biomimetics engineering approach. A novel immune network algorithm (INA) approach was applied to a septic sludge treatment plant (SSTP) for effluent-removal predictive modelling. The Matang SSTP in the city of Kuching, Sarawak, on the island of Borneo, was selected as a case study. Monthly effluent discharges from 2007 to 2011 were used for training, validating, and testing purposes using MATLAB 7.10. The results showed that the BOD effluent-discharge prediction was less than 50% of the specified standard after the 97(th) month of operation. The COD and TSS effluent removals were simulated at the 85(th) and the 121(st) months, respectively. The study proved that the proposed INA-based SSTP model could be used to achieve an effective SSTP assessment and management technique.
    Matched MeSH terms: Waste Disposal, Fluid/methods*
  15. Lim JX, Vadivelu VM
    J Environ Manage, 2014 Dec 15;146:217-225.
    PMID: 25173730 DOI: 10.1016/j.jenvman.2014.07.023
    A sequencing batch reactor (SBR) with a working volume of 8 L and an exchange ratio of 25% was used to enrich biomass for the treatment of the anaerobically treated low pH palm oil mill effluent (POME). The influent concentration was stepwise increased from 5000 ± 500 mg COD/L to 11,500 ± 500 mg COD/L. The performance of the reactor was monitored at different organic loading rates (OLRs). It was found that approximately 90% of the COD content of the POME wastewater was successfully removed regardless of the OLR applied to the SBR. Cycle studies of the SBR show that the oxygen uptake by the biomass while there is no COD reduction may be due to the oxidation of the storage product by the biomass. Further, the growth kinetic parameters of the biomass were determined in batch experiments using respirometer. The maximum specific growth rate (μmax) was estimated to be 1.143 day(-1) while the half saturation constant (Ks) with respect to COD was determined to be 0.429 g COD/L. The decay coefficient (bD) and biomass yield (Y) were found to be 0.131 day(-1) and 0.272 mg biomass/mg COD consumed, respectively.
    Matched MeSH terms: Waste Disposal, Fluid/methods
  16. Syafalni, Lim HK, Ismail N, Abustan I, Murshed MF, Ahmad A
    J Environ Manage, 2012 Dec 15;112:353-9.
    PMID: 22964042 DOI: 10.1016/j.jenvman.2012.08.001
    In this research, the capability of lateritic soil used as coagulant for the treatment of stabilized leachate from the Penang-Malaysia Landfill Site was investigated. The evaluation of lateritic soil coagulant in comparison with commercialized chemical coagulants, such as alum, was performed using conventional jar test experiments. The optimum pH and coagulant dosage were identified for the lateritic soil coagulant and the comparative alum coagulant. It was found that the application of lateritic soil coagulant was quite efficient in the removal of COD, color and ammoniacal-nitrogen content from the landfill leachate. The optimal pH value was 2.0, while 14 g/L of lateritic soil coagulant was sufficient in removing 65.7% COD, 81.8% color and 41.2% ammoniacal-nitrogen. Conversely, the optimal pH and coagulant dosage for the alum were pH 4.8 and 10 g/L respectively, where 85.4% COD, 96.4% color and 47.6% ammoniacal-nitrogen were removed from the same leachate sample. Additionally, the Sludge Volume Index (SVI) ratio of alum and lateritic soil coagulant was 53:1, which indicated that less sludge was produced and was an environmentally friendly product. Therefore, lateritic soil coagulant can be considered a viable alternative in the treatment of landfill leachate.
    Matched MeSH terms: Waste Disposal, Fluid/methods
  17. Al-Amri A, Salim MR, Aris A
    Water Sci Technol, 2011;64(7):1398-405.
    PMID: 22179635 DOI: 10.2166/wst.2011.421
    A study has been carried out to define the effect of drastic temperature changes on the performance of lab-scale hollow-fibre MBR in treating municipal wastewater at a flux of 10 L m(-2) h(-1) (LMH). The objectives of the study were to estimate the activated sludge properties, the removal efficiencies of COD and NH(3)-N and the membrane fouling tendency under critical conditions of drastic temperature changes (23, 33, 42 & 33 °C) and MLSS concentration ranged between 6,382 and 8,680 mg/L. The study exhibited that the biomass reduction, the low sludge settleability and the supernatant turbidity were results of temperature increase. The temperature increase led to increase in SMP carbohydrate and protein, and to decrease in EPS carbohydrate and protein. The BRE of COD dropped from 80% at 23 °C to 47% at 42 °C, while the FRE was relatively constant at about 90%. Both removal efficiencies of NH(3)-N trended from about 100% at 33 °C to less than 50% at 42 °C. TMP and BWP ascended critically with temperature increase up to 336 and 304 mbar respectively by the end of the experiment. The values of suspended solids (SS) and the turbidity in the final effluent were negligible. The DO in the mixed liquor was varying with temperature change, while the pH was within the range of 6.7-8.3.
    Matched MeSH terms: Waste Disposal, Fluid/methods
  18. Chow MF, Yusop Z, Mohamed M
    Water Sci Technol, 2011;63(6):1211-6.
    PMID: 21436558 DOI: 10.2166/wst.2011.360
    This paper examines the storm runoff quality from a commercial area in south Johor, Malaysia. Six storm events with a total of 68 storm runoff samples were analyzed. Event Mean Concentration (EMC) for all constituents analysed showed large inter-event variation. Site mean concentrations (SMC) for total suspended solids (TSS), oil and grease (O&G), biochemical oxygen demand (BOD), chemical oxygen demand (COD), nitrate-nitrogen (NO(3)-N), nitrite-nitrogen (NO(2)-N), ammonia-nitrogen (NH(3)-N), total phosphorus (Total P) and Soluble P are 261, 4.31, 74, 192, 1.5, 0.006, 1.9, 1.12 and 0.38 mg/L, respectively. The SMCs at the studied site are higher than those reported in many urban catchments. The mean baseflow concentrations were higher than the EMCs for COD, Soluble P, NH(3)-N, NO(3)-N, Total P and NO(2)-N. However, the reverse was observed for TSS and O&G. All pollutants showed the occurrence of first flush phenomenon with the highest strength was observed for TSS, COD and NH(3)-N.
    Matched MeSH terms: Waste Disposal, Fluid/methods*
  19. Wong CL, Tan YN, Mohamed AR
    J Environ Manage, 2011 Jul;92(7):1669-80.
    PMID: 21450395 DOI: 10.1016/j.jenvman.2011.03.006
    Titania nanotubes are gaining prominence in photocatalysis, owing to their excellent physical and chemical properties such as high surface area, excellent photocatalytic activity, and widespread availability. They are easily produced by a simple and effective hydrothermal method under mild temperature and pressure conditions. This paper reviews and analyzes the mechanism of titania nanotube formation by hydrothermal treatment. It further examines the parameters that affect the formation of titania nanotubes, such as starting material, sonication pretreatment, hydrothermal temperature, washing process, and calcination process. Finally, the effects of the presence of dopants on the formation of titania nanotubes are analyzed.
    Matched MeSH terms: Waste Disposal, Fluid/methods*
  20. Ahmad T, Rafatullah M, Ghazali A, Sulaiman O, Hashim R
    PMID: 21929380 DOI: 10.1080/10590501.2011.601847
    This article presents a review on the role of oil palm biomass (trunks, fronds, leaves, empty fruit bunches, shells, etc.) as adsorbents in the removal of water pollutants such as acid and basic dyes, heavy metals, phenolic compounds, various gaseous pollutants, and so on. Numerous studies on adsorption properties of various low-cost adsorbents, such as agricultural wastes and its based activated carbons, have been reported in recent years. Studies have shown that oil palm-based adsorbent, among the low-cost adsorbents mentioned, is the most promising adsorbent for removing water pollutants. Further, these bioadsorbents can be chemically modified for better efficiency and can undergo multiple reuses to enhance their applicability at an industrial scale. It is evident from a literature survey of more than 100 recent papers that low-cost adsorbents have demonstrated outstanding removal capabilities for various pollutants. The conclusion is been drawn from the reviewed literature, and suggestions for future research are proposed.
    Matched MeSH terms: Waste Disposal, Fluid/methods*