Displaying all 14 publications

Abstract:
Sort:
  1. Ujang Z, Ng KS, Tg Hamzah TH, Roger P, Ismail MR, Shahabudin SM, et al.
    Water Sci Technol, 2007;56(9):103-8.
    PMID: 18025737
    A pilot scale membrane plant was constructed and monitored in Shah Alam, Malaysia for municipal wastewater reclamation for industrial application purposes. The aim of this study was to verify its suitability under the local conditions and environmental constraints for secondary wastewater reclamation. Immersed-type crossflow microfiltration (IMF) was selected as the pretreatment step before reverse osmosis filtration. Secondary wastewater after chlorine contact tank was selected as feed water. The results indicated that the membrane system is capable of producing a filtrate meeting the requirements of both WHO drinking water standards and Malaysian Effluent Standard A. With the application of an automatic backwash process, IMF performed well in hydraulic performance with low fouling rate being achieved. The investigations showed also that chemical cleaning is still needed because of some irreversible fouling by microorganisms always remains. RO treatment with IMF pretreatment process was significantly applicable for wastewater reuse purposes and promised good hydraulic performance.
    Matched MeSH terms: Filtration/instrumentation
  2. Jamal R, Mazeni NR, Hussin H
    Malays J Pathol, 2000 Dec;22(2):79-83.
    PMID: 16329539
    The advent of leukocyte filters has enabled effective removal of leukocytes from certain blood products thus avoiding many adverse effects of blood transfusion. Many different materials have been incorporated into these filters to achieve >95% leukocyte removal. In this study we evaluated the efficacy of leukocyte removal of two different filters, using actual bedside transfusion settings involving patients with transfusion dependent thalassaemia. Fifty-one transfusion events were randomised to use either a polyurethane filter or a non-woven polyester filter. We found that the two filters achieved 98.4% and 96.2% leukocyte removal respectively (p = 0.022). We also found no significant correlation between pre-filtration white blood cell count and the volume transfused with the efficacy of leukodepletion. No untoward events or transfusion reactions were observed during the study.
    Matched MeSH terms: Filtration/instrumentation*
  3. Hashim MA, Sen Gupta B
    Bioseparation, 1997;7(1):17-23.
    PMID: 9615610
    The effects of pump speed, cumulative permeate volume and concentration of feed (yeast cells) on the permeate flux have been studied on a batch cross-flow microfiltration process. The experiments were conducted for two different cellulose acetate membrane modules of 0.2 micron and 0.45 micron pore size. A three factor experiment was designed for this purpose and the effect of the operating parameters on the filtration rate was studied by the analysis of variance (ANOVA). It is concluded from the analysis of the experimental data that pump speed has the maximum bearing upon the permeate rate within the operating range of parameters. Fouling conditions were examined in the light of colloids deposition on membranes due to surface interactions. However this paper looks into the relationship and sensitivity of the operating parameters in a cross-flow microfiltration unit rather than exploring the theoretical principles behind the observed phenomena.
    Matched MeSH terms: Filtration/instrumentation
  4. Abu Hasan H, Abdullah SR, Kofli NT, Kamarudin SK
    Bioresour Technol, 2012 Nov;124:355-63.
    PMID: 22995166 DOI: 10.1016/j.biortech.2012.08.055
    This study determined the most effective microbes acting as ammonia-oxidising (AOB) and manganese-oxidising bacteria (MnOB) for the simultaneous removal of ammonia (NH(4)(+)-N) and manganese (Mn(2+)) from water. Two conditions of mixed culture of bacteria: an acclimatised mixed culture (mixed culture: MC) in a 5-L bioreactor and biofilm attached on a plastic medium (stages of mixed culture: SMC) in a biological aerated filter were isolated and identified using Biolog MicroSystem and 16S rRNA sequencing. A screening test for determining the most effective microbe in the removal of NH(4)(+)-N and Mn(2+) was initially performed using SMC and MC, respectively, and found that Bacillus cereus was the most effective microbe for the removal of NH(4)(+)-N and Mn(2+). Moreover, the simultaneous NH(4)(+)-N and Mn(2+) removal (above 95% removal for both NH(4)(+)-N and Mn(2+)) was achieved using a biological aerated filter under various operating conditions. Thus, the strain could act as an effective microbe of AOB and a MnOB for the simultaneous removal of NH(4)(+)-N and Mn(2+).
    Matched MeSH terms: Filtration/instrumentation*
  5. Leo CP, Chai WK, Mohammad AW, Qi Y, Hoedley AF, Chai SP
    Water Sci Technol, 2011;64(1):199-205.
    PMID: 22053475
    A high concentration of phosphorus in wastewater may lead to excessive algae growth and deoxygenation of the water. In this work, nanofiltration (NF) of phosphorus-rich solutions is studied in order to investigate its potential in removing and recycling phosphorus. Wastewater samples from a pulp and paper plant were first analyzed. Commercial membranes (DK5, MPF34, NF90, NF270, NF200) were characterized and tested in permeability and phosphorus removal experiments. NF90 membranes offer the highest rejection of phosphorus; a rejection of more than 70% phosphorus was achieved for a feed containing 2.5 g/L of phosphorus at a pH <2. Additionally, NF90, NF200 and NF270 membranes show higher permeability than DK5 and MPF34 membranes. The separation performance of NF90 is slightly affected by phosphorus concentration and pressure, which may be due to concentration polarization and fouling. By adjusting the pH to 2 or adding sulfuric acid, the separation performance of NF90 was improved in removing phosphorus. However, the presence of acetic acid significantly impairs the rejection of phosphorus.
    Matched MeSH terms: Filtration/instrumentation
  6. Walter JK, Jin Z, Jornitz MW, Gorrschalk U
    Methods Biochem Anal, 2011;54:281-317.
    PMID: 21954783
    Matched MeSH terms: Filtration/instrumentation*
  7. Ahmad AL, Tan LS, Shukor SR
    J Hazard Mater, 2008 Feb 28;151(1):71-7.
    PMID: 17587496
    In order to produce sufficient food supply for the ever-increasing human population, pesticides usage is indispensable in the agriculture sector to control crop losses. However, the effect of pesticides on the environment is very complex as undesirable transfers occur continually among different environmental sections. This eventually leads to contamination of drinking water source especially for rivers located near active agriculture practices. This paper studied the application of nanofiltration membrane in the removal of dimethoate and atrazine in aqueous solution. Dimethoate was selected as the subject of study since it is being listed as one of the pesticides in guidelines for drinking water by World Health Organization. Nevertheless, data on effectiveness of dimethoate rejection using membranes has not been found so far. Meanwhile, atrazine is classified as one of the most commonly used pesticides in Malaysia. Separation was done using a small batch-type membrane separation cell with integrated magnetic stirrer while concentration of dimethoate and atrazine in aqueous solution was analyzed using high performance liquid chromatography (HPLC). Four nanofiltration membranes NF90, NF200, NF270 and DK were tested for their respective performance to separate dimethoate and atrazine. Of all four membranes, NF90 showed the best performance in retention of dimethoate and atrazine in water.
    Matched MeSH terms: Filtration/instrumentation
  8. Yap S, Duraisamy G
    Med J Malaysia, 1992 Jun;47(2):150-3.
    PMID: 1494336
    Matched MeSH terms: Filtration/instrumentation*
  9. Ng ML, Sazali BS, Khalid BA
    Ann. Clin. Biochem., 1991 Nov;28 ( Pt 6):613-7.
    PMID: 1776812
    A filter method for collection and storage of capillary blood spots for glycated haemoglobin (gHb) has been developed. Glass fibre filters (GFB) impregnated with 0.8 M boric acid were used to collect and store capillary blood. Haemoglobin from the dried blood spots was eluted into water and determined by Drabkin's method, while gHb in the eluates was determined by the microcolorimetric method. The intraassay coefficients of variation (CVs) were 4.5, 4.5 and 3.1% at 882, 1101 and 1704 pmol HMF/mg Hb, respectively. The corresponding inter-assay CVs were 8.6, 8.6 and 6.3%, respectively. A total of 63 paired capillary and venous blood samples were measured by both the direct and GFB method. The GFB method showed excellent correlation with the direct method (r = 0.948 and r = 0.994) after 7 and 14 days' storage at room temperature. The GFB method will enable prior collection and postage of blood samples by patients.
    Matched MeSH terms: Filtration/instrumentation*
  10. Lau WJ, Gray S, Matsuura T, Emadzadeh D, Chen JP, Ismail AF
    Water Res, 2015 Sep 1;80:306-24.
    PMID: 26011136 DOI: 10.1016/j.watres.2015.04.037
    This review focuses on the development of polyamide (PA) thin film nanocomposite (TFN) membranes for various aqueous media-based separation processes such as nanofiltration, reverse osmosis and forward osmosis since the concept of TFN was introduced in year 2007. Although the total number of published TFN articles falls far short of the articles of the well-known thin film composite (TFC) membranes, its growth rate is significant, particularly since 2012. Generally, by incorporating an appropriate amount of nanofiller into a thin selective PA layer of a composite membrane, one could produce TFN membranes with enhanced separation characteristics as compared to the conventional TFC membrane. For certain cases, the resulting TFN membranes demonstrate not only excellent antifouling resistance and/or greater antibacterial effect, but also possibly overcome the trade-off effect between water permeability and solute selectivity. Furthermore, this review attempts to give the readers insights into the difficulties of incorporating inorganic nanomaterials into the organic PA layer whose thickness usually falls in a range of several-hundred nanometers. It is also intended to show new possible approaches to overcome these challenges in TFN membrane fabrication.
    Matched MeSH terms: Filtration/instrumentation
  11. Rosman N, Salleh WNW, Mohamed MA, Jaafar J, Ismail AF, Harun Z
    J Colloid Interface Sci, 2018 Dec 15;532:236-260.
    PMID: 30092507 DOI: 10.1016/j.jcis.2018.07.118
    Reports of pharmaceuticals exist in surface water and drinking water around the world, indicate they are ineffectively remove from water and wastewater using conventional treatment technologies. The potential of adverse effect of these pharmaceuticals on public health and aquatic life, also their continuos accumulation have raised the development of water treatment technologies. Hybrid treatment processes like membrane filtration and advance oxidation processes (AOPs) are likely to give rise to efficient simultaneous degradation and separation mechanisms. Conventional membrane filtration techniques can remove the majority of contaminants, but the smallest, undegraded, and stabilized pharmaceutical wastes persist in the treated water. After some 20 years, researchers have recognized the important role of AOPs in the treatment of pharmaceutical wastewater because these technologies are capable of oxidizing recalcitrant, toxic, and non-biodigradable compounds into numerous by-products and finally, inert end-products via the intermediacy of hydroxyl and other radicals. Evidently, membranes are subjected to the fouling phenomenon by the contaminants in wastewater, hence resulting in a reduction of clean water flux and increase in energy demand. In such situations, these membrane hybrid AOPs exert a complementary effect in the elimination of membrane fouling, thus enhancing the performance of the membrane. Therefore, in this review, we describe the basic aspects of the removal and transformation of certain pharmaceuticals via membranes and AOPs. In addition, information and evidences on membrane hybrid AOPs in the field of pharmaceutical wastewater treatment is also presented.
    Matched MeSH terms: Filtration/instrumentation*
  12. Tee HC, Lim PE, Seng CE, Nawi MA
    Bioresour Technol, 2012 Jan;104:235-42.
    PMID: 22130081 DOI: 10.1016/j.biortech.2011.11.032
    The objectives of this study are to compare the performance of newly developed baffled and conventional horizontal subsurface-flow (HSF) constructed wetlands in the removal of nitrogen at the hydraulic retention times (HRT) of 2, 3 and 5 days and to evaluate the potential of rice husk as wetland media for wastewater treatment. The results show that the planted baffled unit achieved 74%, 84% and 99% ammonia nitrogen (NH(4)(+)-N) removal versus 55%, 70% and 96% for the conventional unit at HRT of 2, 3 and 5 days, respectively. The better performance of the baffled unit was explained by the longer pathway due to the up-flow and down-flow conditions sequentially thus allowing more contact of the wastewater with the rhizomes and micro-aerobic zones. Near complete total oxidized nitrogen was observed due to the use of rice husk as wetland media which provided the COD as the electron donor in the denitrification process.
    Matched MeSH terms: Filtration/instrumentation*
  13. Tan KK, Lee WS, Liaw LC, Oh A
    Singapore Med J, 1993 Apr;34(2):109-11.
    PMID: 8266145
    Two hundred and eleven blood transfusions were administered to 26 multi-transfused thalassemic children (aged 9 months-13 years) over a 6-month period. Eighteen children were receiving buffy coat-poor packed red cells (PRC) prepared by centrifuge while 8 children received filtered blood through a leucocyte-filter (Sepacell R-500A). Transfusion reactions occurred in 8.5% (n = 18) of transfusions and in 42.3% (n = 11) of patients. 11.9% (n = 16) and 2.6% (n = 2) of reactions occurred in 50% (n = 9) and 25% (n = 2) of patients receiving buffy coat-poor PRC and filtered blood respectively. Transfusion reactions in toto were significantly reduced in the group receiving filtered blood (p < 0.05). However, febrile reaction alone was not significantly reduced (p > 0.1). The median onset and duration of reaction were 2 hours (range 10 minutes-18 hours) and 4 hours (range 1/2-24 hours) respectively. 72.2% (n = 13) of the reactions occurred occurred during transfusion. 88.8% (n = 16) of the reactions caused only one symptom. 19.2% (n = 5) of all patients had recurrent reactions, all of them receiving buffy coat-poor PRC. The commonest clinical manifestation was fever (n = 7), followed by urticaria (n = 5) and petechial rash (n = 2). The outcome was good, with no patient experiencing symptoms exceeding 24 hours. Only 0.9% (n = 2) of the transfusions were discontinued.
    Matched MeSH terms: Filtration/instrumentation*
  14. Abdullah N, Yusof N, Abu Shah MH, Wan Ikhsan SN, Ng ZC, Maji S, et al.
    Environ Sci Pollut Res Int, 2019 Jul;26(20):20386-20399.
    PMID: 31102226 DOI: 10.1007/s11356-019-05208-9
    In this present study, adsorptive membranes for Cr(VI) ion removal were prepared by blending polyethersulfone (PES) with hydrous ferric oxide (HFO) nanoparticles (NPs). The effects of HFO NPs to PES weight ratio (0-1.5) on the physicochemical properties of the resultant HFO/PES adsorptive membranes were investigated with respect to the surface chemistry and roughness as well as structural morphologies using different analytical instruments. The adsorptive performance of the HFO NPs/PES membranes was studied via batch adsorption experiments under various conditions by varying solution pH, initial concentration of Cr(VI), and contact time. The results showed that the membrane made of HFO/PES at a weight ratio of 1.0 exhibited the highest adsorption capacity which is 13.5 mg/g. Isotherm and kinetic studies revealed that the mechanism is best fitted to the Langmuir model and pseudo-second-order model. For filtration of Cr(VI), the best promising membranes showed improved water flux (629.3 L/m2 h) with Cr(VI) ion removal of 75%. More importantly, the newly developed membrane maintained the Cr(VI) concentration below the maximum contamination level (MCL) for up to 9 h.
    Matched MeSH terms: Filtration/instrumentation
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links