Displaying all 19 publications

Abstract:
Sort:
  1. Abdullah NR, Furuta T, Taib R, Kita K, Kojima S, Wah MJ
    Am J Trop Med Hyg, 1996 Feb;54(2):162-3.
    PMID: 8619441
    We describe here a reverse transcriptase-polymerase chain reaction method for the detection of malaria parasites. Ten in vitro-cultured isolates of Plasmodium falciparum and 16 specimens from patients infected with P. falciparum were used to examine the specificity and sensitivity of the test. The sensitivity of the test was 0.3 parasites per microliter of blood. Specificity was determined by matching the sequences of the specimens' DNA to published sequences of 18S ribosomal RNA genes in the species-specific region. The test proved to be very sensitive and specific for the detection of P. falciparum infection.
    Matched MeSH terms: Malaria, Falciparum/diagnosis*
  2. Sidhu PS, Ng SC
    Ann Acad Med Singap, 1991 May;20(3):324-7.
    PMID: 1929172
    The case records of 64 patients with malaria over a five year period admitted to the University Hospital, Kuala Lumpur were examined. There were 32 cases of P. falciparum, 26 cases of P. vivax and two cases of mixed infections. Four cases of P. malariae were recorded. The clinical findings, biochemical and haematological parameters were examined for any indication of a pernicious syndrome. A high index of suspicion of a malarial infection may be based on the findings of anaemia, thrombocytopaenia, hyponatraemia, renal failure and abnormal liver function tests in the face of a negative blood film. These pernicious syndromes occur more often in malignant tertian malaria (anaemia 50%, hyponatraemia 39.1%) but a high percentage of the other malarial species show these abnormalities (P. vivax anaemia 57.7%, hyponatraemia 19.2%). When these abnormalities are present but blood films for malaria parasites are negative, repeat blood films are warranted until a parasitological diagnosis is achieved and correct treatment may be started.
    Matched MeSH terms: Malaria, Falciparum/diagnosis
  3. Sulaiman H, Ismail MD, Jalalonmuhali M, Atiya N, Ponnampalavanar S
    Malar J, 2014;13:341.
    PMID: 25176417 DOI: 10.1186/1475-2875-13-341
    This case report describes a case of presumed acute myocardial infarction in a returned traveler who was later diagnosed to have severe malaria. Emergency coronary angiography was normal and subsequent peripheral blood film was positive for Plasmodium falciparum.
    Matched MeSH terms: Malaria, Falciparum/diagnosis*
  4. Atroosh WM, Al-Mekhlafi HM, Al-Jasari A, Sady H, Al-Delaimy AK, Nasr NA, et al.
    Parasit Vectors, 2015;8:388.
    PMID: 26198252 DOI: 10.1186/s13071-015-1008-x
    The genetic variation in the Plasmodium falciparum histidine-rich protein 2 (pfhrp2) gene that may compromise the use of pfhrp2-based rapid diagnostic tests (RDTs) for the diagnosis of malaria was assessed in P. falciparum isolates from Yemen.
    Matched MeSH terms: Malaria, Falciparum/diagnosis*
  5. Khoo A, Furuta T, Abdullah NR, Bah NA, Kojima S, Wah MJ
    Trans R Soc Trop Med Hyg, 1996 1 1;90(1):40-1.
    PMID: 8730308
    Matched MeSH terms: Malaria, Falciparum/diagnosis*
  6. Hakim SL, Furuta T, Rain AN, Normaznah Y, Zamri MR, Kojima S, et al.
    Trans R Soc Trop Med Hyg, 1995 5 1;89(3):271-2.
    PMID: 7660430
    Matched MeSH terms: Malaria, Falciparum/diagnosis
  7. Vishalkumar P, Jayaprakash NS, Desai PK, Krishnan V, Vijayalakshmi MA
    Trop Biomed, 2020 Dec 01;37(4):1050-1061.
    PMID: 33612757 DOI: 10.47665/tb.37.4.1050
    OBJECTIVE: To evaluate the sensitivity and the stability of the monoclonal antibodies (Aa3c10, b10c1), against truncated Histidine-rich protein 2 (PfHRP2), developed using smart polymer, poly N-isopropylacrylamide, as adjuvant for malarial diagnostic applications in comparison with the available commercial antibodies.

    METHODS: Two hybridoma clones (Aa3c10, b10c1) were used for the production of ascites in BALB/c mice. Purification of monoclonal antibodies from the ascites was carried out using affinity columns. The thermal stability study of monoclonal antibodies was done by storing it at 37°C and 45°C for thirty days. The stored antibodies were analyzed using SDS-PAGE and flow-through device where the antigenantibody interaction was visualized by Protein A colloidal gold solution. Sensitivity was determined by endpoint dilution ELISA and the dissociation constant by competitive ELISA. Sensitive pair optimization was done by sandwich ELISA using biotinylated antibodies. Prototype preparation for lateral flow assay had a colloidal gold-based detection system.

    RESULTS: Thermal stability experiments showed that both mAbs (Aa3c10; b10c1) are stable up to thirty days at 45°C while the commercially available mAbs were stable up to fifteen days only. Compared to commercial antibodies, the mAb Aa3c10, showed the highest sensitivity in end-point titre. In sensitive pair optimization, it was observed that the mAb, b10c1, as a detector and the mAb, Aa3c10, as a capture antibody showed the highest absorbance to detect 50pg/ml PfHRP2 antigen. The prototype formulation of lateral flow assay using the mAbs (Aa3c10; b10c1) showed good reactivity with WHO panel and no false-positive results were observed with twenty clinically negative samples and five P. vivax positive samples.

    CONCLUSIONS: The novel monoclonal antibodies (Aa3c10, b10c1) against truncated PfHRP2, could be a strong potential candidates that can be included in making RDTs with better sensitivity and stability.

    Matched MeSH terms: Malaria, Falciparum/diagnosis*
  8. Alareqi LM, Mahdy MA, Lau YL, Fong MY, Abdul-Ghani R, Ali AA, et al.
    Malar J, 2016 Jan 28;15:49.
    PMID: 26821911 DOI: 10.1186/s12936-016-1103-2
    Malaria is a public health threat in Yemen, with 149,451 cases being reported in 2013. Of these, Plasmodium falciparum represents 99%. Prompt diagnosis by light microscopy (LM) and rapid diagnostic tests (RTDs) is a key element in the national strategy of malaria control. The heterogeneous epidemiology of malaria in the country necessitates the field evaluation of the current diagnostic strategies, especially RDTs. Thus, the present study aimed to evaluate LM and an RDT, combining both P. falciparum histidine-rich protein-2 (PfHRP-2) and Plasmodium lactate dehydrogenase (pLDH), for falciparum malaria diagnosis and survey in a malaria-endemic area during the transmission season against nested polymerase chain reaction (PCR) as the reference method.
    Matched MeSH terms: Malaria, Falciparum/diagnosis*
  9. Boush MA, Djibrine MA, Mussa A, Talib M, Maki A, Mohammed A, et al.
    Sci Rep, 2020 07 30;10(1):12822.
    PMID: 32733079 DOI: 10.1038/s41598-020-69756-8
    In remote areas of malaria-endemic countries, rapid diagnostic tests (RDTs) have dramatically improved parasitological confirmation of suspected malaria cases, especially when skilled microscopists are not available. This study was designed to determine the frequency of Plasmodium falciparum isolates with histidine-rich protein 2 (pfhrp2) gene deletion as one of the possible factors contributing to the failure of PfHRP2-based RDTs in detecting malaria. A total of 300 blood samples were collected from several health centres in Nyala City, Western Sudan. The performance of PfHRP2-based RDTs in relation to microscopy was examined and the PCR-confirmed samples were investigated for the presence of pfhrp2 gene. A total of 113 out of 300 patients were P. falciparum positive by microscopy. Among them, 93.81% (106 out of 113) were positives by the PfHRP2 RDTs. Seven isolates were identified as false negative on the basis of the RDTs results. Only one isolate (0.9%; 1/113) potentially has pfhrp2 gene deletion. The sensitivity and specificity of PfHRP2-based RDTs were 93.81% and 100%, respectively. The results provide insights into the pfhrp2 gene deletion amongst P. falciparum population from Sudan. However, further studies with a large and systematic collection from different geographical settings across the country are needed.
    Matched MeSH terms: Malaria, Falciparum/diagnosis*
  10. Beshir KB, Grignard L, Hajissa K, Mohammed A, Nurhussein AM, Ishengoma DS, et al.
    Am J Trop Med Hyg, 2020 08;103(2):558-560.
    PMID: 32553046 DOI: 10.4269/ajtmh.20-0467
    Rapid diagnostic tests (RDTs) play a critical role in malaria diagnosis and control. The emergence of Plasmodium falciparum parasites that can evade detection by RDTs threatens control and elimination efforts. These parasites lack or have altered genes encoding histidine-rich proteins (HRPs) 2 and 3, the antigens recognized by HRP2-based RDTs. Surveillance of such parasites is dependent on identifying false-negative RDT results among suspected malaria cases, a task made more challenging during the current pandemic because of the overlap of symptoms between malaria and COVID-19, particularly in areas of low malaria transmission. Here, we share our perspective on the emergence of P. falciparum parasites lacking HRP2 and HRP3, and the surveillance needed to identify them amid the COVID-19 pandemic.
    Matched MeSH terms: Malaria, Falciparum/diagnosis*
  11. Cho SJ, Lee J, Lee HJ, Jo HY, Sinniah M, Kim HY, et al.
    Int J Biol Sci, 2016;12(7):824-35.
    PMID: 27313496 DOI: 10.7150/ijbs.14408
    Rapid diagnostic tests (RDTs) can detect anti-malaria antibodies in human blood. As they can detect parasite infection at the low parasite density, they are useful in endemic areas where light infection and/or re-infection of parasites are common. Thus, malaria antibody tests can be used for screening bloods in blood banks to prevent transfusion-transmitted malaria (TTM), an emerging problem in malaria endemic areas. However, only a few malaria antibody tests are available in the microwell-based assay format and these are not suitable for field application. A novel malaria antibody (Ab)-based RDT using a differential diagnostic marker for falciparum and vivax malaria was developed as a suitable high-throughput assay that is sensitive and practical for blood screening. The marker, merozoite surface protein 1 (MSP1) was discovered by generation of a Plasmodium-specific network and the hierarchical organization of modularity in the network. Clinical evaluation revealed that the novel Malaria Pf/Pv Ab RDT shows improved sensitivity (98%) and specificity (99.7%) compared with the performance of a commercial kit, SD BioLine Malaria P.f/P.v (95.1% sensitivity and 99.1% specificity). The novel Malaria Pf/Pv Ab RDT has potential for use as a cost-effective blood-screening tool for malaria and in turn, reduces TTM risk in endemic areas.
    Matched MeSH terms: Malaria, Falciparum/diagnosis
  12. Al-abd NM, Mahdy MA, Al-Mekhlafi AM, Snounou G, Abdul-Majid NB, Al-Mekhlafi HM, et al.
    PLoS One, 2013;8(7):e67853.
    PMID: 23861823 DOI: 10.1371/journal.pone.0067853
    The accuracy of the conclusions from in vivo efficacy anti-malarial drug trials depends on distinguishing between recrudescences and re-infections which is accomplished by genotyping genes coding P. falciparum merozoite surface 1 (MSP1) and MSP2. However, the reliability of the PCR analysis depends on the genetic markers' allelic diversity and variant frequency. In this study the genetic diversity of the genes coding for MSP1 and MSP2 was obtained for P. falciparum parasites circulating in Yemen.
    Matched MeSH terms: Malaria, Falciparum/diagnosis*
  13. Zainudin NS, Othman N, Muhi J, Abdu Sani AA, Noordin R
    Am J Trop Med Hyg, 2015 Dec;93(6):1268-73.
    PMID: 26392156 DOI: 10.4269/ajtmh.15-0333
    This study was performed to identify circulating Plasmodium falciparum proteins in patient serum, which may be useful as diagnostic markers. Depletion of highly abundant proteins from each pooled serum sample obtained from P. falciparum-infected patients and healthy individuals was performed using the Proteoseek Antibody-Based Albumin/IgG Removal Kit (Thermo Scientific, Rockford, IL). In analysis 1, the depleted serum was analyzed directly by NanoLC-MS/MS. In analysis 2, the depleted serum was separated by two-dimensional electrophoresis followed by western blot analysis. Subsequently, the selected band was analyzed by NanoLC-MS/MS. The result of analysis 1 revealed the presence of two mature erythrocyte surface antigen (MESA) proteins and chloroquine resistance transporter protein (PfCRT). In addition, analysis 2 revealed an antigenic 75-kDa band when the membrane was probed with purified IgG from the pooled serum obtained from P. falciparum-infected patients. MS/MS analysis of this protein band revealed fragments of P. falciparum MESA proteins. Thus, in this study, two different analyses revealed the presence of Plasmodium MESA protein in pooled serum from malaria patients; thus, this protein should be further investigated to determine its usefulness as a diagnostic marker.
    Matched MeSH terms: Malaria, Falciparum/diagnosis
  14. Lim PK, Mak JW, Yong HS
    PMID: 1298082
    Two monoclonal antibodies (MAbs), one produced against Plasmodium falciparum (PF-IG8) and the other against P. cynomolgi (PC-IE12) schizont antigens were used in a sandwich ELISA for the detection of circulating plasmodial antigens in sera of patients infected with either P. falciparum, P. vivax or P. malariae. The mean +/- SD optical density (OD) values for the normal control group using PF-108 and PC-1E12 were 0.351 +/- 0.036 and 0.205 +/- 0.044, respectively. Mean OD values for the three infected groups were found to be significantly higher than those of the normal control group for both MAbs. However, ELISA values for individual serum specimens did not correlate with the level of parasitemia in the infected blood. Using a cut-off point of mean OD +/- 3 SD of the normal control group as indicating a positive reading, the specificity of this assay with both MAbs was 100%. The sensitivity of the assay using PF-1G8 was 95% while that obtained with PC-1E12 was 98%.
    Matched MeSH terms: Malaria, Falciparum/diagnosis
  15. Cox-Singh J, Mahayet S, Abdullah MS, Singh B
    Int J Parasitol, 1997 Dec;27(12):1575-7.
    PMID: 9467744
    Malaria remains a disease of underdeveloped and remote regions of the world. The application of polymerase chain reaction (PCR) technology to malaria epidemiology has the potential for increasing our knowledge and understanding of this disease. In order to study malaria in all geographical locations it is important that specimen collection and DNA extraction for PCR be kept simple. Here we report a method for extracting DNA from dried blood spots on filter paper which is capable of detecting one Plasmodium falciparum and two Plasmodium vivax parasites/microliter of whole blood by nested PCR without compromising the simplicity of specimen collection or DNA extraction.
    Matched MeSH terms: Malaria, Falciparum/diagnosis*
  16. Gurpreet K
    Trop Biomed, 2009 Apr;26(1):57-66.
    PMID: 19696728 MyJurnal
    An epidemiological cross-sectional study was undertaken to determine the endemicity of malaria among the Orang Asli population of Raub, Pahang. Malaria endemicity was measured in terms of the prevalence of parasitaemia and splenomegaly. A total of 520 Orang Asli were examined. The point prevalence of malaria was 24.2% (95% CI 20.7-25.1), with Plasmodium falciparum (67.5%) being the predominant species. Children < 12 years were at least 3.7 times more likely to be parasitaemic compared to those older. The prevalence of malaria among children 2-<10 years was 38.1% (95% CI 31.6-50.0). Spleen rate among children 2-<10 years old was 22.3% (95% CI 17.1-28.3). The average enlarged spleen size was 1.2. These findings classify the study area as being mesoendemic. Malaria control activities among the Orang Asli should focus on protecting vulnerable subgroups like young children. Measuring the level of malaria endemicity at regular intervals is fundamental in evaluating the effectiveness of malaria control programs.
    Matched MeSH terms: Malaria, Falciparum/diagnosis
  17. Mussa A, Talib M, Mohamed Z, Hajissa K
    BMC Res Notes, 2019 Jun 11;12(1):334.
    PMID: 31186056 DOI: 10.1186/s13104-019-4361-6
    OBJECTIVE: Rapid diagnostic tests (RDTs) play a crucial role in the management and control of malaria infection. The histidine-rich protein 2 (PfHRP-2) based RDTs are the most commonly used RDTs for malaria diagnosis in Sudan. Deletion of pfhrp2 in Plasmodium falciparum genome affect the accuracy of PfHRP-2 based RDT kits. This study aimed to identify molecular variation of pfhrp2 among suspected malaria patients from different clinics in Omdurman, Sudan.

    RESULTS: A noticeable variation between the RDT (Alltest Biotech, China) and nPCR results was observed, for RDT 78% (46/59) were P. falciparum positive, 6.8% (4/59) were co-infected with both P. falciparum and Plasmodium vivax, 15.3% (9/59) were negative by the RDT. However, when the nPCR was applied only 44.1% (26/59) and 55.9% (33/59) was P. falciparum positive and negative respectively. The pfhrp2 was further amplified form all nPCR positive samples. Only 17 DNA samples were positive from the 26 positive P. falciparum, interestingly, variation in band sizes was observed and further confirmed by DNA sequencing, and sequencing analysis revealed a high-level of genetic diversity of the pfhrp2 gene in the parasite population from the study area. However, despite extreme sequence variation, diversity of PfHRP2 does not appear to affect RDT performance.

    Matched MeSH terms: Malaria, Falciparum/diagnosis*
  18. Koh KH, Chew PH, Kiyu A
    Singapore Med J, 2004 Jan;45(1):28-36.
    PMID: 14976579
    To study the clinical and demographic aspects as well as the outcomes of severe cases of malaria infections managed in the intensive care unit of the Sarawak General Hospital, Kuching from January 1996 to December 2001.
    Matched MeSH terms: Malaria, Falciparum/diagnosis
  19. Daneshvar C, Davis TM, Cox-Singh J, Rafa'ee MZ, Zakaria SK, Divis PC, et al.
    Clin Infect Dis, 2009 Sep 15;49(6):852-60.
    PMID: 19635025 DOI: 10.1086/605439
    BACKGROUND: Plasmodium knowlesi is increasingly recognized as a cause of human malaria in Southeast Asia but there are no detailed prospective clinical studies of naturally acquired infections.

    METHODS: In a systematic study of the presentation and course of patients with acute P. knowlesi infection, clinical and laboratory data were collected from previously untreated, nonpregnant adults admitted to the hospital with polymerase chain reaction-confirmed acute malaria at Kapit Hospital (Sarawak, Malaysia) from July 2006 through February 2008.

    RESULTS: Of 152 patients recruited, 107 (70%) had P. knowlesi infection, 24 (16%) had Plasmodium falciparum infection, and 21 (14%) had Plasmodium vivax. Patients with P. knowlesi infection presented with a nonspecific febrile illness, had a baseline median parasitemia value at hospital admission of 1387 parasites/microL (interquartile range, 6-222,570 parasites/microL), and all were thrombocytopenic at hospital admission or on the following day. Most (93.5%) of the patients with P. knowlesi infection had uncomplicated malaria that responded to chloroquine and primaquine treatment. Based on World Health Organization criteria for falciparum malaria, 7 patients with P. knowlesi infection (6.5%) had severe infections at hospital admission. The most frequent complication was respiratory distress, which was present at hospital admission in 4 patients and developed after admission in an additional 3 patients. P. knowlesi parasitemia at hospital admission was an independent determinant of respiratory distress, as were serum creatinine level, serum bilirubin, and platelet count at admission (p < .002 for each). Two patients with knowlesi malaria died, representing a case fatality rate of 1.8% (95% confidence interval, 0.2%-6.6%).

    CONCLUSIONS: Knowlesi malaria causes a wide spectrum of disease. Most cases are uncomplicated and respond promptly to treatment, but approximately 1 in 10 patients develop potentially fatal complications.

    Matched MeSH terms: Malaria, Falciparum/diagnosis
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links