Displaying all 15 publications

Abstract:
Sort:
  1. Yew KL
    Med J Malaysia, 2012 Dec;67(6):618-9.
    PMID: 23770958 MyJurnal
    We are seeing more implantation of cardiac device such as pacemakers and defibrillators and also cardiac implantable electronic device infection. The infection may affect just the pocket site or progress to deeper infection and bacteraemia. Inadequately treated infection may lead to right sided endocarditis, cardiotomy for pacemaker explantation and increased cost and length of stay in the hospital. We report a Staphylococcal infection of a pacemaker system, its successful medical and surgical management.
    Matched MeSH terms: Prosthesis-Related Infections*
  2. Zairul-Nizam ZF, Badaruddin BS
    J Orthop Surg (Hong Kong), 2006 Aug;14(2):216-8.
    PMID: 16914793
    Infection following total knee arthroplasty can be devastating. Even with established treatment protocols, eradication of the infection may not be feasible. We report 2 patients who required above-knee amputation to eradicate recalcitrant infection.
    Matched MeSH terms: Prosthesis-Related Infections/drug therapy*; Prosthesis-Related Infections/microbiology; Prosthesis-Related Infections/surgery
  3. Zainal Abidin I, Syed Tamin S, Huat Tan L, Chong WP, Azman W
    Pacing Clin Electrophysiol, 2007 Nov;30(11):1420-2.
    PMID: 17976112
    Infection is a relatively rare but devastating complication of intracardiac device implantation. Burkholderia pseudomallei is the organism which causes melioidosis, an endemic and lethal infection in the tropics. We describe a case of pacemaker infection secondary to Burkholderia pseudomallei, which was treated by explantation of the device and appropriate antimicrobial therapy.
    Matched MeSH terms: Prosthesis-Related Infections/diagnosis*; Prosthesis-Related Infections/etiology*
  4. Shunmugaperumal T
    Recent Pat Drug Deliv Formul, 2010 Jun;4(2):153-73.
    PMID: 20236065
    Upon implantation or insertion into patient's body for exerting the intended purpose like salvage of normal functions of vital organs, the medical devices are unfortunately becoming the sites of competition between host cell integration and microbial adhesion. Moreover, since there is an increased use of implanted medical devices, the incidence of biofilm-and medical devices-related nosocomial infections is also increasing progressively. To control microbial colonization and subsequent biofilm formation of the medical devices, different approaches either to enhance the efficiency of certain antimicrobial agents or to disrupt the basic physiology of the pathogenic microorganisms including novel small molecules and antipathogenic drugs are being explored. In addition, the various lipid-and polymer-based drug delivery carriers are also investigated for applying antibiofilm coating of the medical devices especially over catheters. The main intention of this review is therefore to summarize the major and/breakthrough inventions disclosed in patent literature as well as in research papers related to microbial colonization of medical devices and novel preventive strategies. This review starts with an overview of the preventive strategies followed by a short description about the potential of different lipidic-and polymeric-drug delivery carriers in eradicating the biofilm-associated infections from the medical devices.
    Matched MeSH terms: Prosthesis-Related Infections/microbiology; Prosthesis-Related Infections/prevention & control
  5. Ramasamy C
    J Coll Physicians Surg Pak, 2015 Aug;25(8):628.
    PMID: 26305318 DOI: 08.2015/JCPSP.628628
    Matched MeSH terms: Prosthesis-Related Infections/etiology; Prosthesis-Related Infections/prevention & control*
  6. Mittal S, Wilkoff BL, Kennergren C, Poole JE, Corey R, Bracke FA, et al.
    Heart Rhythm, 2020 07;17(7):1115-1122.
    PMID: 32087357 DOI: 10.1016/j.hrthm.2020.02.011
    BACKGROUND: The World-wide Randomized Antibiotic Envelope Infection Prevention trial reported a 40% reduction in major cardiac implantable electronic device (CIED) infections within 12 months of the procedure with the use of an antibacterial-eluting envelope (TYRX Absorbable Antibacterial Envelope, Medtronic, Mounds View, MN).

    OBJECTIVE: The purpose of this report was to describe the longer-term (>12 months) envelope effects on infection reduction and complications.

    METHODS: All trial patients who underwent CIED replacement, upgrade, revision, or initial cardiac resynchronization therapy - defibrillator implantation received standard-of-care infection prophylaxis and were randomized in a 1:1 ratio to receive the envelope or not. CIED infection incidence and procedure and system-related complications were characterized through all follow-up (36 months) by using Cox proportional hazards regression modeling.

    RESULTS: In total, 6800 patients received their intended randomized treatment (3371 envelope; 3429 control; mean follow-up period 21.0 ± 8.3 months). Major CIED-related infections occurred in 32 envelope patients and 51 control patients (Kaplan-Meier [KM] estimate 1.3% vs 1.9%; hazard ratio [HR] 0.64; 95% confidence interval [CI] 0.41-0.99; P = .046). Any CIED-related infection occurred in 57 envelope patients and 84 control patients (KM estimate 2.1% vs 2.8%; HR 0.69; 95% CI 0.49-0.97; P = .030). System- or procedure-related complications occurred in 235 envelope patients and 252 control patients (KM estimate 8.0% vs 8.2%; HR 0.95; 95% CI 0.79-1.13; P < .001 for noninferiority); the most common were lead dislodgment (1.1%), device lead damage (0.5%), and implant site hematoma (0.4%). Implant site pain occurred less frequently in the envelope group (0.1% vs 0.4%; P = .067). There were no (0.0%) reports of allergic reactions to the components of the envelope (mesh, polymer, or antibiotics).

    CONCLUSION: The effects of the TYRX envelope on the reduction of the risk of CIED infection are sustained beyond the first year postprocedure, without an increased risk of complications.

    Matched MeSH terms: Prosthesis-Related Infections/epidemiology; Prosthesis-Related Infections/prevention & control*
  7. Haseeb A, Ajit Singh V, Teh CSJ, Loke MF
    J Orthop Surg (Hong Kong), 2019 5 30;27(2):2309499019850324.
    PMID: 31138005 DOI: 10.1177/2309499019850324
    BACKGROUND: Ceftaroline is a cephalosporin that is effective against methicillin-resistant Staphylococcus aureus (MRSA) infections. The objective of this study was to determine the feasibility of using ceftaroline-loaded Polymethyl methacrylate (PMMA) as antibiotic cement against MRSA versus vancomycin-loaded PMMA in an in vitro setting.

    METHODS: PMMA pellets were prepared with three separate concentrations of each of the two antibiotics tested. They were tested to determine the effect of increasing concentration of antibiotics on the biomechanical properties of PMMA and antibiotic activity by measuring the zone of inhibition and broth elution assay.

    RESULTS: Ceftaroline PMMA at 3 wt%, three-point bending was 37.17 ± 0.51 N ( p < 0.001) and axial loading was 41.95 N ± 0.51 ( p < 0.001). At 5-wt% vancomycin-PMMA, three-point bending was 41.65 ± 0.79 N ( p = 0.02) and axial loading was 49.49 ± 2.21 N ( p = 0.01). Stiffness of ceftroline-loaded PMMA in low and medium concentration was significantly higher than the vancomycin. The zone of inhibition for ceftaroline was higher than vancomycin. Ceftaroline at 3 wt% eluted up to 6 weeks (0.3 ± 0.1 μg/ml) above the minimum inhibitory concentration (MIC) and vancomycin at 2.5 wt% eluted up to 3 weeks, same as MIC, that is, 0.5 ± 0.0 μg/ml.

    CONCLUSIONS: Ceftaroline, loaded at similar concentrations as vancomycin into PMMA, is a more potent alternative based on its more favourable bioactivity and elution properties, while having a lesser effect on the mechanical properties of the cement. The use of 3-wt% ceftaroline as antibiotic laden PMMA against MRSA is recommended. It should be noted that this was an in vitro study and to determine the clinical efficacy would need prospective, controlled and randomized studies.

    Matched MeSH terms: Prosthesis-Related Infections/drug therapy*; Prosthesis-Related Infections/microbiology; Prosthesis-Related Infections/physiopathology
  8. Saw A, Chua YP, Hossain G, Sengupta S
    J Orthop Surg (Hong Kong), 2012 Aug;20(2):181-4.
    PMID: 22933675
    To assess the monthly rates of infection of individual pin sites in 7 patients during distraction osteogenesis.
    Matched MeSH terms: Prosthesis-Related Infections/epidemiology*
  9. Wazir NN, Mukundala VV, Choon DS
    J Orthop Surg (Hong Kong), 2006 Apr;14(1):43-6.
    PMID: 16598086 DOI: 10.1177/230949900601400110
    PURPOSE: To evaluate the short-term clinical and functional outcomes of total hip arthroplasty performed for physiologically active elderly patients with Garden type-3 or -4 femoral neck fracture.
    METHODS: Records of 47 consecutive patients (40 female, 7 male) with type-3 or -4 femoral neck fracture (Garden classification) who underwent cemented total hip arthroplasty at our hospital during January 1999 to December 2002 were reviewed. Radiological and clinical (Harris functional hip score and Oxford hip score) assessments of 38 patients were measured with a mean follow-up period of 21 months (range, 4-48 months).
    RESULTS: The mean age of the 47 patients was 75 years (range, 62-89 years). Records of 9 patients were excluded because of death, lost to follow-up, and development of deep infection that necessitated implant removal and excision arthroplasty. The mean Harris hip score of the 38 patients was 83 (range, 59-97), whereas the mean Oxford hip score was 25.2 (range, 14-33). Pain in the hips was absent in 30 patients, 6 had slight pain occasionally, and 2 patients had mild-to-moderate hip discomfort. No signs of aseptic loosening or change in implant position were noted on radiographic assessment. Two cases of dislocation were reduced by closed reduction. Two patients had deep wound infection and were treated with debridement, implant removal, and conversion to girdle stone.
    CONCLUSION: This short-term study showed that total hip arthroplasty for femoral neck fracture had good postoperative results in functional hip and pain scores. More attention should be paid to coexisting medical illness (e.g. diabetes mellitus, hypertension, and ischaemic heart disease) and prevention of infection.
    Matched MeSH terms: Prosthesis-Related Infections/surgery
  10. Lee CK, Chua YP, Saw A
    Clin Orthop Relat Res, 2012 Feb;470(2):610-5.
    PMID: 21842299 DOI: 10.1007/s11999-011-1990-z
    Pin site infection is a common problem in external fixation. Plain gauze wetted with normal saline is commonly used for a pin site dressing owing to the simplicity and low cost. Evidence to support adding an antimicrobial agent in the dressing material is lacking.
    Matched MeSH terms: Prosthesis-Related Infections/microbiology; Prosthesis-Related Infections/prevention & control*
  11. Singh VA, Sim LH, Haseeb A, Ju CTS
    J Orthop Surg (Hong Kong), 2018 10 23;26(3):2309499018806671.
    PMID: 30343651 DOI: 10.1177/2309499018806671
    PURPOSE: Allograft infection remains the greatest challenge in orthopaedic reconstructive surgery especially methicillin-resistant Staphylococcus aureus (MRSA). This risk can be minimized with the use of antibiotic laden allograft (ALA) via iontophoresis. Ceftaroline fosamil (CF) is an advanced-generation cephalosporin, an alternative treatment for MRSA infections. Its antibacterial activity and safety profile are better than vancomycin. CF iontophoresed bone has not been used before. This study was conducted to establish the feasibility of creating a CF ALA and establish the prime conditions for its expenditure.

    METHOD: We created an iontophoresis cell; 3% CF was inserted within medullary segment of goat bone and sealed from external saline solution. The cell operated at the following voltages 30, 60 and 90 V and at the following durations 5, 10, 15, 20, 25 and 30 min. Information regarding optimal conditions for its application was then obtained. After which, correlation between voltages and time with CF concentration in the bone was analysed. A bioavailability test was also conducted to observe the optimal rate of CF elution from the graft.

    RESULT: The optimal condition for the impregnation process is 3% CF at 90 V for 10 min. Bone graft impregnated with CF at optimal conditions can elute above minimum inhibitory concentration of the CF against MRSA for 21 days.

    CONCLUSION: CF iontophoresis was found feasible for allograft impregnation. The technique is simple, inexpensive and reproducible clinically. Iontophoresis offers a novel solution to reduce the rate of perioperative infection in reconstructive surgery involving use of bone graft.

    Matched MeSH terms: Prosthesis-Related Infections/epidemiology; Prosthesis-Related Infections/prevention & control*
  12. Chendran P, Seng Fai T, Wan Abdul Halim WH, Md Din N
    J Glaucoma, 2019 10;28(10):e162-e164.
    PMID: 31368915 DOI: 10.1097/IJG.0000000000001334
    Ocular pyogenic granuloma is a benign tumor seen after ocular insult secondary to ocular surgeries, trauma or infection. Although benign, intervention is sometimes necessary. Previous authors have reported pyogenic granuloma formation following oculoplastic surgeries. We report a pyogenic granuloma after an Ahmed glaucoma valve implantation. A 65-year-old gentleman presented with right eye redness associated with pain and swelling ~2 months after Ahmed glaucoma valve implantation. Examination found a sessile growth on the tube extruding puss with signs of endophthalmitis. The glaucoma drainage device was explanted and culture results grew Staphylococcus aureus. This article discusses the formation of pyogenic granuloma on a glaucoma drainage device and its management.
    Matched MeSH terms: Prosthesis-Related Infections/diagnosis; Prosthesis-Related Infections/drug therapy; Prosthesis-Related Infections/microbiology*
  13. Pusparajah P, Letchumanan V, Law JW, Ab Mutalib NS, Ong YS, Goh BH, et al.
    Int J Mol Sci, 2021 Aug 28;22(17).
    PMID: 34502269 DOI: 10.3390/ijms22179360
    Biofilms formed by methicillin-resistant S. aureus (MRSA) are among the most frequent causes of biomedical device-related infection, which are difficult to treat and are often persistent and recurrent. Thus, new and effective antibiofilm agents are urgently needed. In this article, we review the most relevant literature of the recent years reporting on promising anti-MRSA biofilm agents derived from the genus Streptomyces bacteria, and discuss the potential contribution of these newly reported antibiofilm compounds to the current strategies in preventing biofilm formation and eradicating pre-existing biofilms of the clinically important pathogen MRSA. Many efforts are evidenced to address biofilm-related infections, and some novel strategies have been developed and demonstrated encouraging results in preclinical studies. Nevertheless, more in vivo studies with appropriate biofilm models and well-designed multicenter clinical trials are needed to assess the prospects of these strategies.
    Matched MeSH terms: Prosthesis-Related Infections/drug therapy*
  14. Zubaidah NH, Azim MI, Osama MH, Harunarashid H, Das S
    Clin Ter, 2012;163(1):27-9.
    PMID: 22362230
    The incidence of infection following TEVAR is low. To the best of our knowledge, this is the first case report of post thoracic endovascular aortic repair (TEVAR) with Streptococcus viridans graft infection. A 54-year-old male underwent TEVAR for dissecting thoracic aneurysm with spinal ischaemia. He had an eventful recovery with prolonged period of stay in intensive care unit. Three months later, he presented with persistent chest discomfort and fever. Computed tomography (CT) of the thorax revealed evidence of graft infection and the blood culture grew Streptococcus viridans. The rarity of TEVAR graft infection due to Streptococcus viridans and its management are being discussed.
    Matched MeSH terms: Prosthesis-Related Infections/drug therapy; Prosthesis-Related Infections/microbiology*; Prosthesis-Related Infections/radiography
  15. Santoso A, Yoon TR, Park KS, Anwar IB, Utomo P, Soetjahjo B, et al.
    Malays Orthop J, 2020 Mar;14(1):18-23.
    PMID: 32296477 DOI: 10.5704/MOJ.2003.003
    Introduction: Periprosthetic joint infection (PJI) of the hip due to methicillin-resistant bacteria is difficult to treat and remain a challenge for arthroplasty surgeon.

    Material and Methods: Retrospective review was done to the patients who received two-stage revisions with an antibiotic loaded cement-spacer for PJI of the hip between January 2010 to May 2015. We found 65 patients (65 hips) with positive culture findings. Eight patients were lost to follow-up and excluded from the study. Among the rest of the 57 patients, methicillin-resistant infection (MR Group) was found in 28 cases. We also evaluate the 29 other cases that caused by the other pathogen as control group. We compared all of the relevant medical records and the treatment outcomes between the two groups.

    Results: The mean of follow-up period was 33.7 months in the methicillin-resistant group and 28.4 months in the control group (p = 0.27). The causal pathogens in the methicillin-resistant group were: Methicillin-resistant Staphylococcus aureus (MRSA) in 10 cases, Methicillin-resistant Staphylococcus epidermidis (MRSE) in 16 cases and Methicillin-resistant coagulase-negative Staphylococcus (MRCNS) in two cases. The reimplantation rate was 92.8% and 89.6% in the methicillin-resistant and control group, respectively (p= 0.66). The rates of recurrent infection after reimplantation were 23.1% (6/26) in the methicillin-resistant group and 7.6% (2/26) in the control group (p= 0.12). The overall infection control rate was 71.4% (20/28) and 89.6% (26/29) in the methicillin-resistant and control group, respectively (p = 0.08). Both groups showed comparable baseline data on mean age, BMI, gender distribution, preoperative ESR/CRP/WBC and comorbidities.

    Conclusions: Two-stage revision procedure resulted in low infection control rate and high infection recurrency rate for the treatment of methicillin-resistant periprosthetic joint infection (PJI) of the hip. Development of the treatment strategy is needed to improve the outcome of methicillin-resistant periprosthetic joint infection (PJI) of the hip.

    Matched MeSH terms: Prosthesis-Related Infections