Displaying all 4 publications

Abstract:
Sort:
  1. Rengarajan A, Rogers BD, Wong Z, Tolone S, Sifrim D, Serra J, et al.
    Clin Gastroenterol Hepatol, 2022 Mar;20(3):e398-e406.
    PMID: 33144149 DOI: 10.1016/j.cgh.2020.10.052
    OBJECTIVE: High-resolution manometry (HRM) is the current standard for characterization of esophageal body and esophagogastric junction (EGJ) function. We aimed to examine the prevalence of abnormal esophageal motor patterns in health, and to determine optimal thresholds for software metrics across HRM systems.

    DESIGN: Manometry studies from asymptomatic adults were solicited from motility centers worldwide, and were manually analyzed using integrated relaxation pressure (IRP), distal latency (DL), and distal contractile integral (DCI) in standardized fashion. Normative thresholds were assessed using fifth and/or 95th percentile values. Chicago Classification v3.0 criteria were applied to determine motor patterns across HRM systems, study positions (upright vs supine), ages, and genders.

    RESULTS: Of 469 unique HRM studies (median age 28.0, range 18-79 years). 74.6% had a normal HRM pattern; none had achalasia. Ineffective esophageal motility (IEM) was the most frequent motor pattern identified (15.1% overall), followed by EGJ outflow obstruction (5.3%). Proportions with IEM were lower using stringent criteria (10.0%), especially in supine studies (7.1%-8.5%). Other motor patterns were rare (0.2%-4.1% overall) and did not vary by age or gender. DL thresholds were close to current norms across HRM systems, while IRP thresholds varied by HRM system and study position. Both fifth and 95th percentile DCI values were lower than current thresholds, both in upright and supine positions.

    CONCLUSIONS: Motor abnormalities are infrequent in healthy individuals and consist mainly of IEM, proportions of which are lower when using stringent criteria in the supine position. Thresholds for HRM metrics vary by HRM system and study position.

  2. Siboni S, Sozzi M, Kristo I, Boveri S, Rogers BD, De Bortoli N, et al.
    United European Gastroenterol J, 2024 Jun;12(5):552-561.
    PMID: 38536701 DOI: 10.1002/ueg2.12565
    OBJECTIVE: A definitive diagnosis of gastroesophageal reflux disease (GERD) depends on endoscopic and/or pH-study criteria. However, high resolution manometry (HRM) can identify factors predicting GERD, such as ineffective esophageal motility (IEM), esophago-gastric junction contractile integral (EGJ-CI), evaluating esophagogastric junction (EGJ) type and straight leg raise (SLR) maneuver response. We aimed to build and externally validate a manometric score (Milan Score) to stratify the risk and severity of the disease in patients undergoing HRM for suspected GERD.

    METHODS: A population of 295 consecutive patients undergoing HRM and pH-study for persistent typical or atypical GERD symptoms was prospectively enrolled to build a model and a nomogram that provides a risk score for AET > 6%. Collected HRM data included IEM, EGJ-CI, EGJ type and SLR. A supplemental cohort of patients undergoing HRM and pH-study was also prospectively enrolled in 13 high-volume esophageal function laboratories across the world in order to validate the model. Discrimination and calibration were used to assess model's accuracy. Gastroesophageal reflux disease was defined as acid exposure time >6%.

    RESULTS: Out of the analyzed variables, SLR response and EGJ subtype 3 had the highest impact on the score (odd ratio 18.20 and 3.87, respectively). The external validation cohort consisted of 233 patients. In the validation model, the corrected Harrel c-index was 0.90. The model-fitting optimism adjusted calibration slope was 0.93 and the integrated calibration index was 0.07, indicating good calibration.

    CONCLUSIONS: A novel HRM score for GERD diagnosis has been created and validated. The MS might be a useful screening tool to stratify the risk and the severity of GERD, allowing a more comprehensive pathophysiologic assessment of the anti-reflux barrier.

    TRIAL REGISTRATION: ClinicalTrials.gov (Identifier: NCT05851482).

  3. Rogers BD, Rengarajan A, Abrahao L, Bhatia S, Bor S, Carlson DA, et al.
    Neurogastroenterol Motil, 2021 06;33(6):e14009.
    PMID: 33094875 DOI: 10.1111/nmo.14009
    BACKGROUND: Esophagogastric junction contractile integral (EGJ-CI) and EGJ morphology are high-resolution manometry (HRM) metrics that assess EGJ barrier function. Normative data standardized across world regions and HRM manufacturers are limited.

    METHODS: Our aim was to determine normative EGJ metrics in a large international cohort of healthy volunteers undergoing HRM (Medtronic, Laborie, and Diversatek software) acquired from 16 countries in four world regions. EGJ-CI was calculated by the same two investigators using a distal contractile integral-like measurement across the EGJ for three respiratory cycles and corrected for respiration (mm Hg cm), using manufacturer-specific software tools. EGJ morphology was designated according to Chicago Classification v3.0. Median EGJ-CI values were calculated across age, genders, HRM systems, and regions.

    RESULTS: Of 484 studies (28.0 years, 56.2% F, 60.7% Medtronic studies, 26.0% Laborie, and 13.2% Diversatek), EGJ morphology was type 1 in 97.1%. Median EGJ-CI was similar between Medtronic (37.0 mm Hg cm, IQR 23.6-53.7 mm Hg cm) and Diversatek (34.9 mm Hg cm, IQR 22.1-56.1 mm Hg cm, P = 0.87), but was significantly higher using Laborie equipment (56.5 mm Hg cm, IQR 35.0-75.3 mm Hg cm, P 

  4. Siboni S, Kristo I, Rogers BD, De Bortoli N, Hobson A, Louie B, et al.
    Clin Gastroenterol Hepatol, 2023 Jul;21(7):1761-1770.e1.
    PMID: 36270615 DOI: 10.1016/j.cgh.2022.10.008
    BACKGROUND & AIMS: The straight leg raise (SLR) maneuver during high-resolution manometry (HRM) can assess esophagogastric junction (EGJ) barrier function by measuring changes in intraesophageal pressure (IEP) when intra-abdominal pressure is increased. We aimed to determine whether increased esophageal pressure during SLR predicts pathologic esophageal acid exposure time (AET).

    METHODS: Adult patients with persistent gastroesophageal reflux disease (GERD) symptoms undergoing HRM and pH-impedance or wireless pH study off proton pump inhibitor were prospectively studied between July 2021 and March 2022. After the HRM Chicago 4.0 protocol, patients were requested to elevate 1 leg at 45º for 5 seconds while supine. The SLR maneuver was considered effective when intra-abdominal pressure increased by 50%. IEPs were recorded 5 cm above the lower esophageal sphincter at baseline and during SLR. GERD was defined as AET greater than 6%.

    RESULTS: The SLR was effective in 295 patients (81%), 115 (39%) of whom had an AET greater than 6%. Hiatal hernia (EGJ type 2 or 3) was seen in 135 (46%) patients. Compared with patients with an AET less than 6%, peak IEP during SLR was significantly higher in the GERD group (29.7 vs 13.9 mm Hg; P < .001). Using receiver operating characteristic analysis, an increase of 11 mm Hg of peak IEP from baseline during SLR was the optimal cut-off value to predict an AET greater than 6% (area under the receiver operating characteristic curve, 0.84; sensitivity, 79%; and specificity, 85%), regardless of the presence of hiatal hernia. On multivariable analysis, an IEP pressure increase during the SLR maneuver, EGJ contractile integral, EGJ subtype 2, and EGJ subtype 3, were found to be significant predictors of AET greater than 6% CONCLUSIONS: The SLR maneuver can predict abnormal an AET, thereby increasing the diagnostic value of HRM when GERD is suspected.

    CLINICALTRIALS: gov ID: NCT04813029.

Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links