Displaying publications 1 - 20 of 45 in total

Abstract:
Sort:
  1. Ujang Z, Wong CL, Manan ZA
    Water Sci Technol, 2002;46(11-12):77-84.
    PMID: 12523736
    Industrial wastewater minimization can be conducted using four main strategies: (i) reuse; (ii) regeneration-reuse; (iii) regeneration-recycling; and (iv) process changes. This study is concerned with (i) and (ii) to investigate the most suitable approach to wastewater minimization for an old textile industry plant. A systematic water networks design using water pinch analysis (WPA) was developed to minimize the water usage and wastewater generation for the textile plant. COD was chosen as the main parameter. An integrated design method has been applied, which brings the engineering insight using WPA that can determine the minimum flowrate of the water usage and then minimize the water consumption and wastewater generation as well. The overall result of this study shows that WPA has been effectively applied using both reuse and regeneration-reuse strategies for the old textile industry plant, and reduced the operating cost by 16% and 50% respectively.
  2. Ujang Z, Au YL, Nagaoka H
    Water Sci Technol, 2002;46(9):109-15.
    PMID: 12448459
    This paper describes an investigation on the effect of microbial removal using IMF for high quality drinking water production. The comparison of IMF and IMF-PAC configuration was carried out in the study to highlight the importance of PAC in the system. The specific objective of this study was to study the effect of PAC adsorption in the IMF-PAC system particularly in removing microbial substances from contaminated raw water. A bench scale IMF-PAC configuration using a flat sheet microfiltration membrane was set up for experimental purposes. Experimentally, the result has shown high removal of microbial substances with the IMF-PAC system compared to IMF. The result of E. coli removal achieved was below the detectable level due to the microbial size, which is bigger than membrane pore size. The addition of PAC has shown a direct effect on total microbial removal. The adsorption of microbial onto PAC surfaces reduced the amount of smaller microbial present in permeate samples. As a conclusion, the configuration of IMF is a promising separation process in removing microbial substances, especially when the system is combined with PAC.
  3. Ujang Z, Salim MR, Khor SL
    Water Sci Technol, 2002;46(9):193-200.
    PMID: 12448469
    A laboratory-scale membrane bioreactor (MBR) was fed with synthetic wastewater to investigate the possibility of simultaneous removal of organic, nitrogen and phosphorus by intermittent aeration. The MBR consists of two compartments using a microfiltration membrane with 0.2 microm pore size and a surface area of 0.35 m2. Hydraulic retention time was set at 24 hours and solid retention time 25 days. MLSS concentration in the reactor was in the range of 2,500-3,800 mg/L. The MLSS internal recycling ratio was maintained at 100% influent flow rate. Intermittent aeration was applied in this study to provide an aerobic-anaerobic cycle. Three stages of operations were conducted to investigate the effect of aeration and non-aeration on simultaneous organic and nutrient removal. In Stage 1, time cycles of aeration and non-aeration were set at 90/150 min and 150/90 min in the first and second compartment, the removal efficiency was 97%, 94% and 70% for COD, nitrogen and phosphorus respectively. In Stage 2, time cycles of aeration and non-aeration were set at 60/120 min and 120/60 min in the first and second compartment, the removal efficiency was 97%, 96% and 71% for COD, nitrogen and phosphorus respectively. In Stage 3, time cycles of aeration and non-aeration were set at 120/120 min and 120/120 min in compartment 1 and 2, the removal efficiency was 98%, 96% and 78% for COD, nitrogen and phosphorus respectively. Results show that longer non-aeration time in the second compartment provided better performances of biological phosphorus removal.
  4. Abdul-Talib S, Hvitved-Jacobsen T, Vollertsen J, Ujang Z
    Water Sci Technol, 2002;46(9):185-92.
    PMID: 12448468
    A significant breakthrough and progress have been made in the study of the kinetics of microbial transformation in sewers under aerobic and under changing aerobic/anaerobic conditions. Fundamental knowledge on anoxic kinetics of wastewater is still lacking, so it is not now possible to apply an integrated approach to municipal wastewater treatment incorporating sewer networks as a bio-chemical reactor. This paper presents the results of studies on determining half saturation constants for nitrate, KNO3, and nitrite, KNO2, in raw wastewater. The average values of KNO3 and KNO2, determined from experiments conducted on 7 different wastewater samples were found to be 0.76 gNO3-N/m3 and 0.33 gNO2-N/m3 respectively.
  5. Abdul-Talib S, Hvitved-Jacobsen T, Vollertsen J, Ujang Z
    Water Sci Technol, 2002;45(3):53-60.
    PMID: 11902481
    The sewer is an integral part of the urban wastewater system: the sewer, the wastewater treatment plant and the local receiving waters. The sewer is a reactor for microbial changes of the wastewater during transport, affecting the quality of the wastewater and thereby the successive treatment processes or receiving water impacts during combined sewer overflows. This paper presents the results of studies on anoxic processes, namely denitrification, in the bulk water phase of wastewater as it occurs in sewers. Experiments conducted on 12 different wastewater samples have shown that the denitrification process in the bulk wastewater can be simplified by the reduction of nitrate to nitrogen with significant accumulation of nitrite in the water phase. Utilization of nitrate was observed not to be limited by nitrate for concentrations above 5 gNO3-N/m3. The denitrification rates, under conditions of excess substrate and electron acceptor, were found to be in the range of 0.8-2.0 g NO3-N/(m3h). A discussion on the interaction of the sewer processes and the effects on a downstream located wastewater treatment plant (WWTP) is provided.
  6. Ujang Z, Buckley C
    Water Sci Technol, 2002;46(9):1-9.
    PMID: 12448446
    This paper summarises the paper presentation sessions at the Conference, as well giving insights on the issues related to developing countries. It also discusses the present status of practice and research on water and wastewater management, and projected future scenario based not only on the papers presented in the Conference, but also on other sources. The strategy is presented to overcome many problems in developing countries such as rapid urbanization, industrialization, population growth, financial and institutional problems and, depleting water resources. The strategy consists of Integrated Urban Water Management (IUWM), cleaner industrial production, waste minimisation and financial arrangements.
  7. Al-Shididi S, Henze M, Ujang Z
    Water Sci Technol, 2003;48(11-12):327-35.
    PMID: 14753553
    The objective of this study was to assess the feasibility of the Sequencing Batch Reactor (SBR) system for implementation in Malaysia. Theoretical, field, laboratory investigations, and modelling simulations have been carried out. The results of the study indicated that the SBR system was robust, relatively cost-effective, and efficient under Malaysian conditions. However, the SBR system requires highly skilled operators and continuous monitoring. This paper also attempted to identify operating conditions for the SBR system, which optimise both the removal efficiencies and the removal rates. The removal efficiencies could reach 90-96% for COD, up to 92% for TN, and 95% for SS. An approach to estimate a full operational cycle time, to estimate the de-sludging rate, and to control the biomass in the sludge has also been developed. About 4 hours react time was obtained, as 2.25 hours of nitrification with aerated slow fill and 1.75 hour of denitrification with HAc addition as an additional carbon source. Inefficient settling was one of the problems that affect the SBR effluent quality. The settling time was one hour for achieving Standard B (effluent quality) and 2 hours for Standard A.
  8. Ahmad UK, Ujang Z, Woon CH, Indran S, Mian MN
    Water Sci Technol, 2004;50(9):137-44.
    PMID: 15581005
    Land application of sludge as fertilizers is a way of disposal and recycling of sludge. However, public concern has arisen due to the fact that organic contaminants in sludge may ultimately enter the food chain. Hence the need arises to analyse the organic contaminants such as PAHs and OCPs in sludge. In this study, Soxhlet was utilised as the extraction method and the extracts subjected to extensive cleanup via either silica columns or solid phase extraction cartridges prior to analysis using gas chromatography or high performance liquid chromatography. Sludge samples were collected from the drying beds of oxidation ponds in three locations in South Johore. OCPs such as heptachlor, dieldrin and pp-DDT were detected in low amounts (52-159 mg/kg) whereas PAHs such as naphthalene, phenanthrene, fluoranthene and benzo(a)pyrene were detected in the range of 0.2-5.5 mg/kg dry mass. Subcritical water extraction (SWE) recovery studies of PAHs were also performed from spiked sludge samples. Although a recovery range of 41-68% was obtained using the SWE method, the results indicated the usefulness of the technique as an alternative to Soxhlet extraction for the analysis of PAHs in sludge samples.
  9. Ujang Z, Henze M, Curtis T, Schertenleib R, Beal LL
    Water Sci Technol, 2004;49(8):1-10.
    PMID: 15193088
    This paper presents the existing philosophy, approach, criteria and delivery of environmental engineering education (E3) for developing countries. In general, environmental engineering is being taught in almost all major universities in developing countries, mostly under civil engineering degree programmes. There is an urgent need to address specific inputs that are particularly important for developing countries with respect to the reality of urbanisation and industrialisation. The main component of E3 in the near future will remain on basic sanitation in most developing countries, with special emphasis on the consumer-demand approach. In order to substantially overcome environmental problems in developing countries, E3 should include integrated urban water management, sustainable sanitation, appropriate technology, cleaner production, wastewater minimisation and financial framework.
  10. Ujang Z, Soedjono E, Salim MR, Shutes RB
    Water Sci Technol, 2005;52(12):243-50.
    PMID: 16477992
    Municipal leachate was treated in an experimental unit of constructed wetlands of subsurface flow type. The parameters studied were organics (BOD and COD), solids and heavy metals (Zn, Ni, Cu, Cr and Pb). Using two types of emergent plants of Scirpus globulosus and Eriocaulon sexangulare, more than 80% removal was achieved for all the parameters. E. sexangulare removed organics and heavy metals better than Scirpus globulosus. A higher concentration of heavy metals in the influent did not change the removal efficiency.
  11. Yusop Z, Tan LW, Ujang Z, Mohamed M, Nasir KA
    Water Sci Technol, 2005;52(9):125-32.
    PMID: 16445181
    Runoff quality draining from 17.14 km2 urban catchment in Johor Bahru, Malaysia, was analysed. The land-use consists of residential (30.3%), agricultural (27.3%), open space (27.9%), industrial (8.1%) and commercial (6.4%) areas. Three storm events were sampled in detail. These storms produced stormflow between 0.84 mm and 27.82 mm, and peakflow from 2.19 m3/s to 42.36 m3/s. Water quality showed marked variation during storms especially for TSS, BOD and COD with maximum concentrations of 778 mg/l, 135 mg/l and 358 mg/l, respectively. Concentrations of TOC, DOC, NH3-N, Fe and level of colour were also high. In general, the river quality is badly polluted and falls in Class V based on the Malaysian Interim National Water Quality Standards. Event Mean Concentrations (EMC) for various parameters varied considerably between storms. The largest storm produced higher EMC for TSS, NO3-N and SS whereas the smaller storms tend to register higher EMC for BOD, COD, NH3-N, TOC, Ca, K, Mg, Fe and Zn. Such variations could be explained in terms of pollutant availability and the effects of flushing and dilution. Based on a three-month average recurrence interval (ARI) of rainfall, the estimated event loadings (ton/ha) of TSS, BOD, COD, TOC, NH3-N and NO3-N were 0.055, 0.016, 0.012, 0.039, 0.010, 0.0007 and 0.0002, respectively. Heavy metals present in trace quantities. Storms with 3 months ARI could capture about 70% of the total annual loads of major pollutants.
  12. Abdul-Talib S, Ujang Z, Vollertsen J, Hvitved-Jacobsen T
    Water Sci Technol, 2005;52(3):181-9.
    PMID: 16206858
    A two-stage anoxic transformation process, involving growth of biomass utilizing two types of different electron acceptors, namely nitrate and nitrite, has been observed. The present water quality modules established for sewer processes cannot account for the two-stage process. This paper outlines the development of a model concept that enables the two-stage anoxic transformation process to be simulated. The proposed model is formulated in a matrix form that is similar to the Activated Sludge Models and Sewer Process Model matrices. The model was successfully applied to simulate changes in nitrate and nitrite concentrations during anoxic transformations in the bulkwater phase of municipal wastewater.
  13. Ujang Z, Ng SS, Nagaoka H
    Water Sci Technol, 2005;51(10):335-42.
    PMID: 16104438
    Biofouling control is important for effective process of membrane bioreactor (MBR). In this study, phenomena of biofouling for immersed type extended aeration MBR with two different anti-fouling aeration intensities were studied through a laboratory set up. The objectives of this study were (a) to observe biofouling phenomena of MBR that operates under different anti-fouling bubbling intensity, and simultaneously monitors performance of the MBR in organic carbon and nutrients removal; (b) to compare effectiveness of detergent and detergent-enzyme cleaning solutions in recovering biofouled membranes that operated in the extended aeration MBR. For MBR, which operated under continuous anti-fouling aeration, deposition and accumulation of suspended biomass on membrane surface were prohibited. However, flux loss was inescapable that biofilm layer was the main problem. Membrane cleaning was successfully carried out with detergent-enzyme mixture solutions and its effectiveness was compared with result from cleaning with just detergent solution.
  14. Sari SA, Ujang Z, Ahmad UK
    Water Sci Technol, 2006;54(11-12):289-99.
    PMID: 17302332
    The objective of this study was to investigate the cycling of arsenic in the water column of a post-mining lake. This study is part of a research project to develop health risk assessment for the surrounding population. Inductively Coupled Plasma-Mass Spectrophotometer (ICP-MS) and Capillary Electrophoresis (CE) have been used to analyze the total amount and speciation, respectively. A computer program, called MINTEOA2, which was developed by the United States Environmental Protection Agency (USEPA) was used for predicting arsenic, iron, and manganese as functions of pH and solubility. Studying the pH values and cycle of arsenic shows that the percentage of bound arsenate, As(V) species in the form of HAsO4- increases with range pH from 5 to 7, as well as Fe(II) and Mn(III). As expected phases of arsenic oxides are FeAsO4 and Mn3(AsO4), as a function of solubility, however none of these phases are over saturated and not precipitated. It means that the phases of arsenic oxides have a high solubility.
  15. Din MF, Ujang Z, van Loosdrecht MC, Ahmad A, Sairan MF
    Water Sci Technol, 2006;53(6):15-20.
    PMID: 16749434
    The process for the production of biodegradable plastic material (polyhydroxyalkanoates, PHAs) from microbial cells by mixed-bacterial cultivation using readily available waste (renewable resources) is the main consideration nowadays. These observations have shown impressive results typically under high carbon fraction, COD/N and COD/P (usually described as nutrient-limiting conditions) and warmest temperature (moderate condition). Therefore, the aim of this work is predominantly to select mixed cultures under high storage responded by cultivation on a substrate - non limited in a single batch reactor with shortest period for feeding and to characterize their storage response by using specific and kinetics determination. In that case, the selected-fixed temperature is 30 degrees C to establish tropical conditions. During the accumulated steady-state period, the cell growth was inhibited by high PHA content within the cells because of the carbon reserve consumption. From the experiments, there is no doubt about the PHA accumulation even at high carbon fraction ratio. Apparently, the best accumulation occurred at carbon fraction, 160 +/- 7.97 g COD/g N (PHAmean, = 44.54% of dried cells). Unfortunately, the highest PHA productivity was achieved at the high carbon fraction, 560 +/- 1.62 g COD/g N (0.152 +/- 0.17 g/l. min). Overall results showed that with high carbon fraction induced to the cultivation, the PO4 and NO3 can remove up to 20% in single cultivation.
  16. Ujang Z, Ng KS, Tg Hamzah TH, Roger P, Ismail MR, Shahabudin SM, et al.
    Water Sci Technol, 2007;56(9):103-8.
    PMID: 18025737
    A pilot scale membrane plant was constructed and monitored in Shah Alam, Malaysia for municipal wastewater reclamation for industrial application purposes. The aim of this study was to verify its suitability under the local conditions and environmental constraints for secondary wastewater reclamation. Immersed-type crossflow microfiltration (IMF) was selected as the pretreatment step before reverse osmosis filtration. Secondary wastewater after chlorine contact tank was selected as feed water. The results indicated that the membrane system is capable of producing a filtrate meeting the requirements of both WHO drinking water standards and Malaysian Effluent Standard A. With the application of an automatic backwash process, IMF performed well in hydraulic performance with low fouling rate being achieved. The investigations showed also that chemical cleaning is still needed because of some irreversible fouling by microorganisms always remains. RO treatment with IMF pretreatment process was significantly applicable for wastewater reuse purposes and promised good hydraulic performance.
  17. Salmiati, Ujang Z, Salim MR, Md Din MF, Ahmad MA
    Water Sci Technol, 2007;56(8):179-85.
    PMID: 17978446
    This study aimed to produce polyhydroxyalkanoates (PHAs) from organic wastes by mixed bacterial cultures using anaerobic-aerobic fermentation systems. Palm oil mill effluent (POME) was used as an organic source, which was cultivated in a two-step-process of acidogenesis and acid polymerization. POME was operated in a continuous flow anaerobic reactor to access volatile fatty acids (VFAs) for PHAs production. During fermentation, VFA concentration was produced in the range of 5 to 8 g/L and the COD concentration reduced up to 80% from 65 g/L. The VFA from anaerobic fermentation was then utilised for PHA production using a mixed culture in availability of aerobic bioreactor. Production of PHAs was recorded high when using a high volume of substrates because of the higher VFA concentration. Even though the maximum PHA content was observed at only 40% of the cell dried weight (CDW), their production and performance are significant in mixed microbial culture.
  18. Razak AR, Ujang Z, Ozaki H
    Water Sci Technol, 2007;56(8):161-8.
    PMID: 17978444
    Endocrine disrupting chemicals (EDCs) are the focus of current environmental issues, as they can cause adverse health effects to animals and human, subsequent to endocrine function. The objective of this study was to remove a specific compound of EDCs (i.e. pentachlorophenol, C(6)OCL(5)Na, molecular weight of 288 g/mol) using low pressure reverse osmosis membrane (LPROM). A cross flow module of LPROM was used to observe the effects of operating parameters, i.e. pH, operating pressure and temperature. The design of the experiment was based on MINITAB(TM) software, and the analysis of results was conducted by factorial analysis. It was found that the rejection of pentachlorophenol was higher than 80% at a recovery rate of 60 to 70%. The rejection was subjected to increase with the increase of pH. The flux was observed to be increased with the increase of operating pressure and temperature. This study also investigated the interaction effects between operating parameters involved.
  19. Nor Anuar A, Ujang Z, van Loosdrecht MC, de Kreuk MK
    Water Sci Technol, 2007;56(7):55-63.
    PMID: 17951868
    Aerobic granular sludge (AGS) technology has been extensively studied recently to improve sludge settling and behaviour in activated sludge systems. The main advantage is that aerobic granular sludge (AGS) can settle very fast in a reactor or clarifier because AGS is compact and has strong structure. It also has good settleability and a high capacity for biomass retention. Several experimental works have been conducted in this study to observe the settling behaviours of AGS. The study thus has two aims: (1) to compare the settling profile of AGS with other sludge flocs and (2) to observe the influence of mechanical mixing and design of the reactor to the settleability of AGS. The first experimental outcome shows that AGS settles after less than 5 min in a depth of 0.4 m compared to other sludge flocs (from sequencing batch reactor, conventional activated sludge and extended aeration) which takes more than 30 min. This study also shows that the turbulence from the mixing mechanism and shear in the reactor provides an insignificant effect on the AGS settling velocity.
  20. Lim CK, Halim AS, Lau HY, Ujang Z, Hazri A
    J Appl Biomater Biomech, 2007 May-Aug;5(2):82-7.
    PMID: 20799177
    Chitosan (beta-1, 4-D-glucosamine) is a deacetylated form of chitin with excellent biological properties in wound management. The natural properties of chitosan have the physical and chemical limitations to be widely used in biomedical fields. The improvement of the physical and chemical properties of chitosan with some additional chemicals will alter its biocompatibility. Therefore, the biological attribute of the modified chitosan must be evaluated. In this study, the cytotoxicity of oligo-chitosan (OC) and N, O- carboxymethyl-chitosan (NO-CMC) derivatives (O-C 1%, O-C 5%, NO-CMC 1% and NO-CMC 5%) was evaluated using primary normal human epidermal keratinocyte (pNHEK) cultures as an in vitro toxicology model at standardized cell passages (fourth passages). 3-[4, 5-dimethyl-2-thiazolyl]-2, 5-diphenyl tetrazolium bromide (MTT) was used as a cell viability assay. The O-C 1% is one of the most compatible chitosan derivatives because it steadily sustained >70% of viable cells until 72 hr post-treatment. This was followed by O-C 5%, NO-CMC 5% and NO-CMC 1%. Therefore, oligo-chitosan had the ideal properties of a biocompatible material compared to N, O- carboxymethyl-chitosan in this study.
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links