Displaying publications 1 - 20 of 40 in total

Abstract:
Sort:
  1. Cheng CS, Jong WL, Ung NM, Wong JHD
    Radiat Prot Dosimetry, 2017 Jul 01;175(3):357-362.
    PMID: 27940494 DOI: 10.1093/rpd/ncw357
    This work evaluated and compared the absorbed doses to selected organs in the head and neck region from the three image guided radiotherapy systems: cone-beam computed tomography (CBCT) and kilovoltage (kV) planar imaging using the On-board Imager® (OBI) as well as the ExacTrac® X-ray system, all available on the Varian Novalis TX linear accelerator. The head and neck region of an anthropomorphic phantom was used to simulate patients' head within the imaging field. Nanodots optically stimulated luminescent dosemeters were positioned at selected sites to measure the absorbed doses. CBCT was found to be delivering the highest dose to internal organs while OBI-2D gave the highest doses to the eye lenses. The setting of half-rotation in CBCT effectively reduces the dose to the eye lenses. Daily high-quality CBCT verification was found to increase the secondary cancer risk by 0.79%.
  2. Jong WL, Ung NM, Vannyat A, Rosenfeld AB, Wong JHD
    Phys Med, 2017 Oct;42:39-46.
    PMID: 29173919 DOI: 10.1016/j.ejmp.2017.08.011
    Challenges in treating lung tumours are related to the respiratory-induced tumour motion and the accuracy of dose calculation in charged particle disequilibrium condition. The dosimetric characteristics near the interface of lung and Perspex media in a moving phantom during respiratory-gated and non-gated radiotherapy were investigated using Gafchromic EBT2 and the MOSkin detector. The MOSkin detectors showed good agreement with the EBT2 films during static and gated radiotherapy. In static radiotherapy, the penumbral widths were found to be 3.66mm and 7.22mm in Perspex and lung media, respectively. In non-gated (moving) radiotherapy with 40mm respiratory amplitude, dose smearing effect was observed and the penumbral widths were increased to 28.81mm and 26.40mm, respectively. This has been reduced to 6.85mm and 9.81mm, respectively, in gated radiotherapy with 25% gating window. There were still some dose discrepancies as compared to static radiotherapy due to the residual motion. This should be taken into account in the margin generation for the target tumour.
  3. Wahabi JM, Ung NM, Mahdiraji GA, Wong JHD
    Radiat Prot Dosimetry, 2024 Mar 02;200(3):264-273.
    PMID: 38123475 DOI: 10.1093/rpd/ncad303
    The radioluminescent (RL) dosemeter is excellent for real-time radiation measurement and can be used in various applications. A plastic scintillator is often the choice sensor because of its size and tissue equivalency. This study aims to characterise a novel plastic scintillator irradiated with high-energy photon beams. An RL dosimetry system was developed using the plastic scintillator. The RL dosimetry system was irradiated using a linear accelerator to characterise the dose linearity, dose rate, energy dependency and depth dose. The developed system showed a linear response toward the dose and dose rate. An energy dependency factor of 1.06 was observed. Depth dose measurement showed a mean deviation of 1.21% from the treatment planning system. The response and characteristics of the plastic scintillator show that it may be used as an alternative in an RL dosimetry system.
  4. Jong WL, Ung NM, Vannyat A, Jamalludin Z, Rosenfeld A, Wong JH
    Phys Med, 2017 Jan;33:127-135.
    PMID: 28089106 DOI: 10.1016/j.ejmp.2016.12.020
    Dosimetry in small radiation field is challenging and complicated because of dose volume averaging and beam perturbations in a detector. We evaluated the suitability of the "Edge-on" MOSkin (MOSFET) detector in small radiation field measurement. We also tested the feasibility for dosimetric verification in stereotactic radiosurgery (SRS) and stereotactic radiotherapy (SRT). "Edge-on" MOSkin detector was calibrated and the reproducibility and linearity were determined. Lateral dose profiles and output factors were measured using the "Edge-on" MOSkin detector, ionization chamber, SRS diode and EBT2 film. Dosimetric verification was carried out on two SRS and five SRT plans. In dose profile measurements, the "Edge-on" MOSkin measurements concurred with EBT2 film measurements. It showed full width at half maximum of the dose profile with average difference of 0.11mm and penumbral width with difference of ±0.2mm for all SRS cones as compared to EBT2 film measurement. For output factor measurements, a 1.1% difference was observed between the "Edge-on" MOSkin detector and EBT2 film for 4mm SRS cone. The "Edge-on" MOSkin detector provided reproducible measurements for dose verification in real-time. The measured doses concurred with the calculated dose for SRS (within 1%) and SRT (within 3%). A set of output correction factors for the "Edge-on" MOSkin detector for small radiation fields were derived from EBT2 film measurement and presented. This study showed that the "Edge-on" MOSkin detector is a suitable tool for dose verification in small radiation field.
  5. Chee Ee Phua V, Loo WH, Yusof MM, Wan Ishak WZ, Tho LM, Ung NM
    Asian Pac J Cancer Prev, 2013;14(8):4567-70.
    PMID: 24083703
    BACKGROUND: Nasopharyngeal carcinoma (NPC) is the commonest radiocurable cancer in Malaysia. This study aimed to determine the treatment outcomes and late effects of radiotherapy for NPC patients treated in University Malaya Medical Centre (UMMC).

    MATERIALS AND METHODS: All newly diagnosed patients with NPC referred for treatment to the Oncology unit at UMMC from 2004-2008 were retrospectively analyzed. Treatment outcomes were 5 years overall survival (OS), disease free survival (DFS), cause-specific survival (CSS), loco- regional control (LRC) and radiotherapy-related late effects. The Kaplan-Meier method was used for survival analysis and differences in survival according to AJCC stage was compared using the log-rank test.

    RESULTS: A total of 176 patients with newly diagnosed NPC were treated in UMMC during this period. Late presentation was common, with 33.5% presenting with T3-4 disease, 84.7% with N1-3 disease and 75.6% with AJCC stage 3-4 disease. Radical RT was given to 162 patients with 22.7% having RT alone and 69.3% having CCRT. The stipulated OTT was 7 weeks and 72.2% managed to complete their RT within this time period. Neoadjuvant chemotherapy was given to 14.8% while adjuvant chemotherapy was administered to 16.5%. The 5 years OS was 51.6% with a median follow up of 58 months. The 5 years OS according to stage were 81.8% for stage I, 77.9% for stage II, 47.4% for stage III and 25.9% for stage IV. The 5 years overall CSS, DFS and LRC were 54.4%, 48.4% and 70.6%, respectively. RT related late effects were documented in 80.2%. The commonest was xerostomia (66.7%). Other documented late effects were hearing deficit (17.3%), visual deficit (3.1%), neck stiffness (3.1%) , dysphagia (3.4%), cranial nerve palsy (2.5%), pneumonitis (0.6%) and hypothyroidism (1.2%).

    CONCLUSIONS: The 5 years OS and LRC in this study are low compared to the latest studies especially those utilizing IMRT. Implementation of IMRT for NPC treatment should be strongly encouraged.

  6. Phua Chee Ee V, Tan BS, Tan AL, Eng KY, Ng BS, Ung NM
    Asian Pac J Cancer Prev, 2013;14(4):2243-8.
    PMID: 23725120
    BACKGROUND: To compare the dosimetric coverage of target volumes and organs at risk in the radical treatment of nasopharyngeal carcinoma (NPC) between intensity-modulated radiotherapy (IMRT) and three- dimensional conformal radiotherapy (3DCRT).

    MATERIALS AND METHODS: Data from 10 consecutive patients treated with IMRT from June-October 2011 in Penang General Hospital were collected retrospectively for analysis. For each patient, dose volume histograms were generated for both the IMRT and 3DCRT plans using a total dose of 70Gy. Comparison of the plans was accomplished by comparing the target volume coverage (5 measures) and sparing of organs at risk (17 organs) for each patient using both IMRT and 3DCRT. The means of each comparison target volume coverage measures and organs at risk measures were obtained and tested for statistical significance using the paired Student t-test.

    RESULTS: All 5 measures for target volume coverage showed marked dosimetric superiority of IMRT over 3DCRT. V70 and V66.5 for PTV70 showed an absolute improvement of 39.3% and 24.1% respectively. V59.4 and V56.4 for PTV59.4 showed advantages of 18.4% and 16.4%. Moreover, the mean PTV70 dose revealed a 5.1 Gy higher dose with IMRT. Only 4 out of 17 organs at risk showed statistically significant difference in their means which were clinically meaningful between the IMRT and 3DCRT techniques. IMRT was superior in sparing the spinal cord (less 5.8Gy), V30 of right parotid (less 14.3%) and V30 of the left parotid (less 13.1%). The V55 of the left cochlea was lower with 3DCRT (less 44.3%).

    CONCLUSIONS: IMRT is superior to 3DCRT due to its dosimetric advantage in target volume coverage while delivering acceptable doses to organs at risk. A total dose of 70Gy with IMRT should be considered as a standard of care for radical treatment of NPC.

  7. Rejab M, Wong JHD, Jamalludin Z, Jong WL, Malik RA, Wan Ishak WZ, et al.
    Australas Phys Eng Sci Med, 2018 Jun;41(2):475-485.
    PMID: 29756166 DOI: 10.1007/s13246-018-0647-6
    This study investigates the characteristics and application of the optically-stimulated luminescence dosimeter (OSLD) in cobalt-60 high dose rate (HDR) brachytherapy, and compares the results with the dosage produced by the treatment planning system (TPS). The OSLD characteristics comprised linearity, reproducibility, angular dependence, depth dependence, signal depletion, bleaching rate and cumulative dose measurement. A phantom verification exercise was also conducted using the Farmer ionisation chamber and in vivo diodes. The OSLD signal indicated a supralinear response (R2 = 0.9998). It exhibited a depth-independent trend after a steep dose gradient region. The signal depletion per readout was negligible (0.02%), with expected deviation for angular dependence due to off-axis sensitive volume, ranging from 1 to 16%. The residual signal of the OSLDs after 1 day bleached was within 1.5%. The accumulated and bleached OSLD signals had a standard deviation of ± 0.78 and ± 0.18 Gy, respectively. The TPS was found to underestimate the measured doses with deviations of 5% in OSLD, 17% in the Farmer ionisation chamber, and 7 and 8% for bladder and rectal diode probes. Discrepancies can be due to the positional uncertainty in the high-dose gradient. This demonstrates a slight displacement of the organ at risk near the steep dose gradient region will result in a large dose uncertainty. This justifies the importance of in vivo measurements in cobalt-60 HDR brachytherapy.
  8. Jamalludin Z, Jong WL, Malik RA, Rosenfeld AB, Ung NM
    Phys Med, 2020 Jan;69:52-60.
    PMID: 31830631 DOI: 10.1016/j.ejmp.2019.11.025
    PURPOSE: Dose to the rectum during brachytherapy treatment may differ from an approved treatment plan which can be quantified with in vivo dosimetry (IVD). This study compares the planned with in vivo doses measured with MOSkin and PTW 9112 rectal probe in patients undergoing CT based HDR cervical brachytherapy with Co-60 source.

    METHODS: Dose measurement of a standard pear-shaped plan carried out in phantom to verify the MOSkin dose measurement accuracy. With MOSkin attached to the third diode, RP3 of the PTW 9112, both detectors were inserted into patients' rectum. The RP3 and MOSkin measured doses in 18 sessions as well as the maximum measured doses from PTW 9112, RPmax in 48 sessions were compared to the planned doses.

    RESULTS: Percentage dose differences ΔD (%) in phantom study for two MOSkin found to be 2.22 ± 0.07% and 2.5 ± 0.07%. IVD of 18 sessions resulted in ΔD(%) of -16.3% to 14.9% with MOSkin and ΔD(%) of -35.7% to -2.1% with RP3. In 48 sessions, RPmax recorded ΔD(%) of -37.1% to 11.0%. MOSkin_measured doses were higher in 44.4% (8/18) sessions, while RP3_measured were lower than planned doses in all sessions. RPmax_measured were lower in 87.5% of applications (42/47).

    CONCLUSIONS: The delivered doses proven to deviate from planned doses due to unavoidable shift between imaging and treatment as measured with MOSkin and PTW 9112 detectors. The integration of MOSkin on commercial PTW 9112 surface found to be feasible for rectal dose IVD during cervical HDR ICBT.

  9. Jamalludin Z, Jong WL, Ho GF, Rosenfeld AB, Ung NM
    Australas Phys Eng Sci Med, 2019 Dec;42(4):1099-1107.
    PMID: 31650362 DOI: 10.1007/s13246-019-00809-7
    The MOSkin, a metal-oxide semiconductor field-effect transistor based detector, is suitable for evaluating skin dose due to its water equivalent depth (WED) of 0.07 mm. This study evaluates doses received by target area and unavoidable normal skin during a the case of skin brachytherapy. The MOSkin was evaluated for its feasibility as detector of choice for in vivo dosimetry during skin brachytherapy. A high-dose rate Cobalt-60 brachytherapy source was administered to the tumour located at the medial aspect of the right arm, complicated with huge lymphedema thus limiting the arm motion. The source was positioned in the middle of patients' right arm with supine, hands down position. A 5 mm lead and 5 mm bolus were sandwiched between the medial aspect of the arm and lateral chest to reduce skin dose to the chest. Two calibrated MOSkin detectors were placed on the target and normal skin area for five treatment sessions for in vivo dose monitoring. The mean dose to the target area ranged between 19.9 and 21.1 Gy and was higher in comparison with the calculated dose due to contribution of backscattered dose from lead. The mean measured dose at normal skin chest area was 1.6 Gy (1.3-1.9 Gy), less than 2 Gy per fraction. Total dose in EQD2 received by chest skin was much lower than the recommended skin tolerance. The MOSkin detector presents a reliable real-time dose measurement. This study has confirmed the applicability of the MOSkin detector in monitoring skin dose during brachytherapy treatment due to its small sensitive volume and WED 0.07 mm.
  10. Jamalludin Z, Jong WL, Abdul Malik R, Rosenfeld A, Ung NM
    Phys Med, 2019 Feb;58:1-7.
    PMID: 30824140 DOI: 10.1016/j.ejmp.2019.01.010
    In vivo dosimetry in high dose-rate (HDR) intracavitary brachytherapy (ICBT) is important for assessing the true dose received by surrounding organs at risk during treatment. It also serves as part of the treatment delivery quality assurance and verification program with the use of a suitable dosimeter. Such a dosimeter should be characterized under brachytherapy conditions before clinical application to ensure the accuracy of in vivo measurement. In this study, a MOSFET-based detector, MOSkin, was calibrated and characterized under HDR Cobalt-60 (Co-60) brachytherapy source. MOSkin possessed the major advantages of having small physical and dosimetric sizes of 4.8 × 10-6 mm3 with the ability to provide real-time measurements. Using solid water and polymethyl methacrylate (PMMA) phantom, the detectors' reproducibility, linearity, angular and distance dependency was tested for its suitability as an in vivo detector. Correction factors to account for differences in depth measurements were determined. The MOSkin detector showed a reliable response when tested under Co-60 brachytherapy range of doses with an excellent linearity of R2 = 0.9997 and acceptable reproducibility. A phantom verification study was also conducted to verify the differences between MOSkin responses and treatment planning (TPS) calculated doses. By taking into account several correction factors, deviations ranging between 0.01 and 0.4 Gy were found between MOSkin measured and TPS doses at measurement distance of 20-55 mm. The use of MOSkin as the dosimeter of choice for in vivo dosimetry under Co-60 brachytherapy condition is feasible.
  11. Hizam DA, Jong WL, Zin HM, Ng KH, Ung NM
    Med Dosim, 2021 04 08;46(3):310-317.
    PMID: 33838998 DOI: 10.1016/j.meddos.2021.03.003
    Intensity-modulated radiotherapy (IMRT) treatment planning for head and neck cancer is challenging and complex due to many organs at risk (OAR) in this region. The experience and skills of planners may result in substantial variability of treatment plan quality. This study assessed the performance of IMRT planning in Malaysia and observed plan quality variation among participating centers. The computed tomography dataset containing contoured target volumes and OAR was provided to participating centers. This is to control variations in contouring the target volumes and OARs by oncologists. The planner at each center was instructed to complete the treatment plan based on clinical practice with a given prescription, and the plan was analyzed against the planning goals provided. The quality of completed treatment plans was analyzed using the plan quality index (PQI), in which a score of 0 indicated that all dose objectives and constraints were achieved. A total of 23 plans were received from all participating centers comprising 14 VMAT, 7 IMRT, and 2 tomotherapy plans. The PQI indexes of these plans ranged from 0 to 0.65, indicating a wide variation of plan quality nationwide. Results also reported 5 out of 21 plans achieved all dose objectives and constraints showing more professional training is needed for planners in Malaysia. Understanding of treatment planning system and computational physics could also help in improving the quality of treatment plans for IMRT delivery.
  12. Jamalludin Z, Malik RA, Ung NM
    Phys Eng Sci Med, 2021 Sep;44(3):773-783.
    PMID: 34191272 DOI: 10.1007/s13246-021-01026-x
    Intracavitary cervical brachytherapy delivers high doses of radiation to the target tissue and a portion of these doses will also hit the rectal organs due to their close proximity. Rectal dose can be evaluated from dosimetric parameters in the treatment planning system (TPS) and in vivo (IV) dose measurement. This study analyzed the correlation between IV rectal dose with selected volume and point dose parameters from TPS. A total of 48 insertions were performed and IV dose was measured using the commercial PTW 9112 semiconductor diode probe. In 18 of 48 insertions, a single MOSkin detector was attached on the probe surface at 50 mm from the tip. Four rectal dosimetric parameters were retrospectively collected from TPS; (a) PTW 9112 diode maximum reported dose (RPmax) and MOSkin detector, (b) minimum dose to 2 cc (D2cc), (c) ICRU reference point (ICRUr), and (d) maximum dose from additional points (Rmax). The IV doses from both detectors were analyzed for correlation with these dosimetric parameters. This study found a significantly high correlation between IV measured dose from RPmax (r = 0.916) and MOSkin (r = 0.959) with TPS planned dose. The correlation between measured RPmax with both D2cc and Rmax revealed high correlation of r > 0.7, whereas moderate correlation (r = 0.525) was observed with ICRUr. There was no significant correlation between MOSkin IV measured dose with D2cc, ICRUr and Rmax. The non-significant correlation between parameters was ascribable to differences in both detector position within patients, and dosimetric volume and point location determined on TPS, rather than detector uncertainties.
  13. Mosiun JA, See MH, Teoh LY, Danaee M, Lai LL, Ng CH, et al.
    World J Surg, 2023 Jan;47(1):201-208.
    PMID: 36305952 DOI: 10.1007/s00268-022-06753-0
    BACKGROUND: There is a paucity of data on the use of intraoperative radiotherapy (IORT) with low-energy X-rays in Malaysian women with early breast cancer. The aim of this study is to evaluate the clinical, cosmetic, and patient-reported outcomes in low- and high-risk early breast cancer patients treated with breast conserving surgery (BCS) and IORT.

    METHODOLOGY: Patients suitable for BCS who were treated with IORT between January 2016 and June 2019 from three centres were analysed. They were divided into low-risk and high-risk groups based on the risk of recurrence according to the TARGeted Intraoperative radioTherapy (TARGIT) A and B study criteria. Outcomes of interest included local recurrence, wound complications, and radiation toxicity, with a subset analysed for cosmetic and patient-reported outcomes.

    RESULTS: Within a median follow-up of 31 months, there were 104 and 211 patients in the low- and high-risk groups, respectively. No significant difference was observed in local recurrence rates (low-risk, 1.0% vs. high-risk, 1.4%; p = 1.000). Both cohorts exhibited low frequencies of severe wound complications ranging between 1.4 and 1.9%. No major radiation toxicities were reported in either group. In the subgroup analysis, low-risk patients had significantly better mean scores in the subscales of inframammary fold and scar. Based on the BREAST-Q patient-reported outcomes questionnaire, seven out of nine parameters were scored similarly between both groups with no significant difference.

    CONCLUSION: This study showed that the use of IORT in both low- and high-risk early breast cancers is efficacious and safe with low recurrence rates and an acceptable toxicity profile.

  14. Zahir NSM, Saad M, Alip A, Rejab M, Jamalludin Z, Hizam NDA, et al.
    Phys Eng Sci Med, 2023 Mar;46(1):405-412.
    PMID: 36806157 DOI: 10.1007/s13246-023-01230-x
    Transperineal ultrasound (TPUS) is an image-guided radiotherapy system used for tracking intrafraction prostate displacements in real time. The objectives of this study are to evaluate intrafraction prostate displacements and derive planning target volume (PTV) margins for prostate radiotherapy at our institution. The ultrasound (US) data of nine prostate cancer patients referred for VMAT radiotherapy was retrieved. Prior to beam on, patient position was set up with the US probe positioned transperineally with the aid of reference images (fused US and computed tomography images). In each fraction, prostate displacements in three directions [superior/inferior (SI), left/right (LR) and anterior/posterior (AP)] were recorded. PTV margins were determined using Van Herk's formula. To assess the prostate displacement time trend, continuous displacement data were plotted in 30-s intervals for eight minutes. The intrafraction prostate monitoring found a population mean setup error (Mp) of 0.8, 0.1, - 1.7 mm, a systematic error of (∑p) 0.7, 0.4, 0.9 mm and random error (σp) of 0.2, 0.1, 0.3 mm in SI, LR and AP directions, respectively. The PTV margin was found to be the largest in the AP direction at 2.5 mm compared with 1.9 mm and 1.1 mm for SI and LR directions, respectively. The PTV margin allowed for prostate radiotherapy at our institution was 2.5 mm in all directions. The prostate displacement time trend showed an increase in intrafraction displacements, with most patients were observed to have strong positive correlation between time and intrafraction prostate displacements in SI direction. TPUS is feasible for monitoring intrafraction displacement of the prostate and may facilitate PTV margin generation to account for such displacements during radiotherapy.
  15. Yap LM, Jamalludin Z, Ng AH, Ung NM
    Phys Eng Sci Med, 2023 Sep;46(3):1331-1340.
    PMID: 37470929 DOI: 10.1007/s13246-023-01303-x
    The survey is to assess the current state of adaptive radiation therapy (ART) for head and neck (H&N) cases among radiotherapy centers in Malaysia and to identify any implementation limitations. An online questionnaire was sent to all radiotherapy centers in Malaysia. The 24-question questionnaire consists of general information about the center, ART practices, and limitations faced in implementing ART. 28 out of 36 radiotherapy centers responded, resulting in an overall response rate of 78%. About 52% of the responding centers rescanned and replanned less than 5% of their H&N patients. The majority (88.9%) of the respondents reported the use Cone Beam Computed Tomography alone or in combination with other modalities to trigger the ART process. The main reasons cited for adopting ART were weight loss, changes in the immobilization fitting, and anatomical variation. The adaptation process typically occurred during week 3 or week 4 of treatment. More than half of the respondents require three days or more from re-simulation to starting a new treatment plan. Both target and organ at risk delineation on new planning CT relied heavily on manual delineation by physicians and physicists, respectively. All centers perform patient-specific quality assurance for their new adaptive plans. Two main limitations in implementing ART are "limited financial resources or equipment" and "limitation on technical knowledge". There is a need for a common consensus to standardize the practice of ART and address these limitations to improve the implementation of ART in Malaysia.
  16. Saberi FNM, Liew YM, Sukumaran P, Ung NM
    Photodiagnosis Photodyn Ther, 2023 Sep;43:103715.
    PMID: 37481146 DOI: 10.1016/j.pdpdt.2023.103715
    Head and neck cancer patients are prone to dental caries after radiotherapy. An ex-vivo study was conducted to assess the feasibility of optical coherence tomography (OCT) to detect tooth demineralization due to caries in irradiated teeth. Thirty-nine human molar teeth were subjected to caries lesion induction through irradiation (Group 1), pH cycling (Group 2-1), and both (Group 2-2). The OCT signal attenuation coefficient, µR was assessed and validated against microhardness test and scanning electron microscope (SEM). The µR for Group 1 increased from 10 Gy to 40 Gy, and subsequently decreased after irradiated to 50 Gy and 60 Gy due to damaged enamel microstructure. In Group 2-1, the µR decreased with duration of pH cycling from day 1 to day 14 due to the increase of porosity in enamel layer. However, the µR showed decreasing trend from day 14 to day 28 of pH cycling, resulted from mineral deposition in the enamel layer. Although no significant difference was found in the µR between Group 2-1 and 2-2, SEM of Group 2-2 demonstrated visually higher porosity and larger gaps between microstructures. Irradiation may accelerate caries damage to tooth microstructure by increasing its porosity and brittleness, but larger sample size may be needed to further prove the effect. OCT could potentially be used for early detection of tooth demineralization in vivo based on the measurable µR changes for all groups which are shown negatively correlated with microhardness value (p 
  17. Hizam DA, Tan LK, Saad M, Muaadz A, Ung NM
    Phys Eng Sci Med, 2024 Apr 22.
    PMID: 38647633 DOI: 10.1007/s13246-024-01411-2
    This study aims to assess the accuracy of automatic atlas-based contours for various key anatomical structures in prostate radiotherapy treatment planning. The evaluated structures include the bladder, rectum, prostate, seminal vesicles, femoral heads and penile bulb. CT images from 20 patients who underwent intensity-modulated radiotherapy were randomly chosen to create an atlas library. Atlas contours of the seven anatomical structures were generated using four software packages: ABAS, Eclipse, MIM, and RayStation. These contours were then compared to manual delineations performed by oncologists, which served as the ground truth. Evaluation metrics such as dice similarity coefficient (DSC), mean distance to agreement (MDA), and volume ratio (VR) were calculated to assess the accuracy of the contours. Additionally, the time taken by each software to generate the atlas contour was recorded. The mean DSC values for the bladder exhibited strong agreement (>0.8) with manual delineations for all software except for Eclipse and RayStation. Similarly, the femoral heads showed significant similarity between the atlas contours and ground truth across all software, with mean DSC values exceeding 0.9 and MDA values close to zero. On the other hand, the penile bulb displayed only moderate agreement with the ground truth, with mean DSC values ranging from 0.5 to 0.7 for all software. A similar trend was observed in the prostate atlas contours, except for MIM, which achieved a mean DSC of over 0.8. For the rectum, both ABAS and MIM atlases demonstrated strong agreement with the ground truth, resulting in mean DSC values of more than 0.8. Overall, MIM and ABAS outperformed Eclipse and RayStation in both DSC and MDA. These results indicate that the atlas-based segmentation employed in this study produces acceptable contours for the anatomical structures of interest in prostate radiotherapy treatment planning.
  18. Wong JHD, Zaili Z, Abdul Malik R, Bustam AZ, Saad M, Jamaris S, et al.
    J Appl Clin Med Phys, 2021 Aug;22(8):139-147.
    PMID: 34254425 DOI: 10.1002/acm2.13338
    PURPOSE: This study aims to evaluate in vivo skin dose delivered by intraoperative radiotherapy (IORT) and determine the factors associated with an increased risk of radiation-induced skin toxicity.

    METHODOLOGY: A total of 21 breast cancer patients who underwent breast-conserving surgery and IORT, either as IORT alone or IORT boost plus external beam radiotherapy (EBRT), were recruited in this prospective study. EBT3 film was calibrated in water and used to measure skin dose during IORT at concentric circles of 5 mm and 40 mm away from the applicator. For patients who also had EBRT, the maximum skin dose was estimated using the radiotherapy treatment planning system. Mid-term skin toxicities were evaluated at 3 and 6 months post-IORT.

    RESULTS: The average skin dose at 5 mm and 40 mm away from the applicator was 3.07 ± 0.82 Gy and 0.99 ± 0.28 Gy, respectively. Patients treated with IORT boost plus EBRT received an additional skin dose of 41.07 ± 1.57 Gy from the EBRT component. At 3 months post-IORT, 86% of patients showed no evidence of skin toxicity. However, the number of patients suffering from skin toxicity increased from 15% to 38% at 6 months post-IORT. We found no association between the IORT alone or with the IORT boost plus EBRT and skin toxicity. Older age was associated with increased risk of skin toxicities. A mathematical model was derived to predict skin dose.

    CONCLUSION: EBT3 film is a suitable dosimeter for in vivo skin dosimetry in IORT, providing patient-specific skin doses. Both IORT alone and IORT boost techniques resulted in similar skin toxicity rates.

  19. Jong WL, Wong JH, Ung NM, Ng KH, Ho GF, Cutajar DL, et al.
    J Appl Clin Med Phys, 2014 Sep 08;15(5):4869.
    PMID: 25207573 DOI: 10.1120/jacmp.v15i5.4869
    In vivo dosimetry is important during radiotherapy to ensure the accuracy of the dose delivered to the treatment volume. A dosimeter should be characterized based on its application before it is used for in vivo dosimetry. In this study, we characterize a new MOSFET-based detector, the MOSkin detector, on surface for in vivo skin dosimetry. The advantages of the MOSkin detector are its water equivalent depth of measurement of 0.07 mm, small physical size with submicron dosimetric volume, and the ability to provide real-time readout. A MOSkin detector was calibrated and the reproducibility, linearity, and response over a large dose range to different threshold voltages were determined. Surface dose on solid water phantom was measured using MOSkin detector and compared with Markus ionization chamber and GAFCHROMIC EBT2 film measurements. Dependence in the response of the MOSkin detector on the surface of solid water phantom was also tested for different (i) source to surface distances (SSDs); (ii) field sizes; (iii) surface dose; (iv) radiation incident angles; and (v) wedges. The MOSkin detector showed excellent reproducibility and linearity for dose range of 50 cGy to 300 cGy. The MOSkin detector showed reliable response to different SSDs, field sizes, surface, radiation incident angles, and wedges. The MOSkin detector is suitable for in vivo skin dosimetry.
  20. Hashim N, Jamalludin Z, Ung NM, Ho GF, Malik RA, Phua VC
    Asian Pac J Cancer Prev, 2014;15(13):5259-64.
    PMID: 25040985
    BACKGROUND: CT based brachytherapy allows 3-dimensional (3D) assessment of organs at risk (OAR) doses with dose volume histograms (DVHs). The purpose of this study was to compare computed tomography (CT) based volumetric calculations and International Commission on Radiation Units and Measurements (ICRU) reference-point estimates of radiation doses to the bladder and rectum in patients with carcinoma of the cervix treated with high-dose-rate (HDR) intracavitary brachytherapy (ICBT).

    MATERIALS AND METHODS: Between March 2011 and May 2012, 20 patients were treated with 55 fractions of brachytherapy using tandem and ovoids and underwent post-implant CT scans. The external beam radiotherapy (EBRT) dose was 48.6 Gy in 27 fractions. HDR brachytherapy was delivered to a dose of 21 Gy in three fractions. The ICRU bladder and rectum point doses along with 4 additional rectal points were recorded. The maximum dose (DMax) to rectum was the highest recorded dose at one of these five points. Using the HDR plus 2.6 brachytherapy treatment planning system, the bladder and rectum were retrospectively contoured on the 55 CT datasets. The DVHs for rectum and bladder were calculated and the minimum doses to the highest irradiated 2cc area of rectum and bladder were recorded (D2cc) for all individual fractions. The mean D2cc of rectum was compared to the means of ICRU rectal point and rectal DMax using the Student's t-test. The mean D2cc of bladder was compared with the mean ICRU bladder point using the same statistical test .The total dose, combining EBRT and HDR brachytherapy, were biologically normalized to the conventional 2 Gy/fraction using the linear-quadratic model. (α/β value of 10 Gy for target, 3 Gy for organs at risk).

    RESULTS: The total prescribed dose was 77.5 Gy α/β10. The mean dose to the rectum was 4.58 ± 1.22 Gy for D 2cc, 3.76 ± 0.65 Gy at D ICRU and 4.75 ± 1.01 Gy at DMax. The mean rectal D 2cc dose differed significantly from the mean dose calculated at the ICRU reference point (p<0.005); the mean difference was 0.82 Gy (0.48 -1.19 Gy). The mean EQD2 was 68.52 ± 7.24 Gy α/β3 for D 2cc, 61.71 ± 2.77 Gy α/β3 at D ICRU and 69.24 ± 6.02 Gy α/β3 at DMax. The mean ratio of D 2cc rectum to D ICRU rectum was 1.25 and the mean ratio of D 2cc rectum to DMax rectum was 0.98 for all individual fractions. The mean dose to the bladder was 6.00 ± 1.90 Gy for D 2cc and 5.10 ± 2.03 Gy at D ICRU. However, the mean D 2cc dose did not differ significantly from the mean dose calculated at the ICRU reference point (p=0.307); the mean difference was 0.90 Gy (0.49-1.25 Gy). The mean EQD2 was 81.85 ± 13.03 Gy α/β3 for D 2cc and 74.11 ± 19.39 Gy α/β3 at D ICRU. The mean ratio of D 2cc bladder to D ICRU bladder was 1.24. In the majority of applications, the maximum dose point was not the ICRU point. On average, the rectum received 77% and bladder received 92% of the prescribed dose.

    CONCLUSIONS: OARs doses assessed by DVH criteria were higher than ICRU point doses. Our data suggest that the estimated dose to the ICRU bladder point may be a reasonable surrogate for the D 2cc and rectal DMax for D 2cc. However, the dose to the ICRU rectal point does not appear to be a reasonable surrogate for the D 2cc.

Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links