Displaying publications 1 - 20 of 23 in total

Abstract:
Sort:
  1. Stephenson AJ, Hunter B, Shaw PN, Kassim NSA, Trengove R, Takechi R, et al.
    Anal Bioanal Chem, 2023 Mar;415(7):1357-1369.
    PMID: 36705732 DOI: 10.1007/s00216-023-04527-8
    Despite its critical role in neurodevelopment and brain function, vitamin D (vit-D) homeostasis, metabolism, and kinetics within the central nervous system remain largely undetermined. Thus, it is of critical importance to establish an accurate, highly sensitive, and reproducible method to quantitate vit-D in brain tissue. Here, we present a novel liquid chromatography tandem mass spectrometry (LC-MS/MS) method and for the first time, demonstrate detection of seven major vit-D metabolites in brain tissues of C57BL/6J wild-type mice, namely 1,25(OH)2D3, 3-epi-1,25(OH)2D3, 1,25(OH)2D2, 25(OH)D3, 25(OH)D2, 24,25(OH)2D3, and 24,25(OH)2D2. Chromatographic separation was achieved on a pentaflurophenyl column with 3 mM ammonium formate water/methanol [A] and 3 mM ammonium formate methanol/isopropanol [B] mobile phase components. Detection was by positive ion electrospray tandem mass spectrometry with the EVOQ elite triple quadrupole mass spectrometer with an Advance ultra-high-performance liquid chromatograph and online extraction system. Calibration standards of each metabolite prepared in brain matrices were used to validate the detection range, precision, accuracy, and recovery. Isotopically labelled analogues, 1,25(OH)2D3-d3, 25(OH)D3-c5, and 24,25(OH)2D3-d6, served as the internal standards for the closest molecular-related metabolite in all measurements. Standards between 1 fg/mL and 10 ng/mL were injected with a resulting linear range between 0.001 and 1 ng, with an LLOD and LLOQ of 1 pg/mL and 12.5 pg/mL, respectively. The intra-/inter-day precision and accuracy for measuring brain vit-D metabolites ranged between 0.12-11.53% and 0.28-9.11%, respectively. Recovery in acetonitrile ranged between 99.09 and 106.92% for all metabolites. Collectively, the sensitivity and efficiency of our method supersedes previously reported protocols used to measure vit-D and to our knowledge, the first protocol to reveal the abundance of 25(OH)D2, 1,25(OH)D2, and 24,25(OH)2D2, in brain tissue of any species. This technique may be important in supporting the future advancement of pre-clinical research into the function of vit-D in neurophysiological and neuropsychiatric disorders, and neurodegeneration.
  2. Mittal P, Briggs M, Klingler-Hoffmann M, Kaur G, Packer NH, Oehler MK, et al.
    Anal Bioanal Chem, 2021 Apr;413(10):2721-2733.
    PMID: 33222001 DOI: 10.1007/s00216-020-03039-z
    It is well established that cell surface glycans play a vital role in biological processes and their altered form can lead to carcinogenesis. Mass spectrometry-based techniques have become prominent for analysing N-linked glycans, for example using matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS). Additionally, MALDI MS can be used to spatially map N-linked glycans directly from cancer tissue using a technique termed MALDI MS imaging (MALDI MSI). This powerful technique combines mass spectrometry and histology to visualise the spatial distribution of N-linked glycans on a single tissue section. Here, we performed N-glycan MALDI MSI on six endometrial cancer (EC) formalin-fixed paraffin-embedded (FFPE) tissue sections and tissue microarrays (TMA) consisting of eight EC patients with lymph node metastasis (LNM) and twenty without LNM. By doing so, several putative N-linked glycan compositions were detected that could significantly distinguish normal from cancerous endometrium. Furthermore, a complex core-fucosylated N-linked glycan was detected that could discriminate a primary tumour with and without LNM. Structural identification of these putative N-linked glycans was performed using porous graphitized carbon liquid chromatography tandem mass spectrometry (PGC-LC-MS/MS). Overall, we observed higher abundance of oligomannose glycans in tumour compared to normal regions with AUC ranging from 0.85-0.99, and lower abundance of complex N-linked glycans with AUC ranges from 0.03-0.28. A comparison of N-linked glycans between primary tumours with and without LNM indicated a reduced abundance of a complex core-fucosylated N-glycan (Hex)2(HexNAc)2(Deoxyhexose)1+(Man)3(GlcNAc)2, in primary tumour with associated lymph node metastasis. In summary, N-linked glycan MALDI MSI can be used to differentiate cancerous endometrium from normal, and endometrial cancer with LNM from endometrial cancer without.
  3. Ariffin EY, Lee YH, Futra D, Tan LL, Karim NHA, Ibrahim NNN, et al.
    Anal Bioanal Chem, 2018 Mar;410(9):2363-2375.
    PMID: 29504083 DOI: 10.1007/s00216-018-0893-1
    A novel electrochemical DNA biosensor for ultrasensitive and selective quantitation of Escherichia coli DNA based on aminated hollow silica spheres (HSiSs) has been successfully developed. The HSiSs were synthesized with facile sonication and heating techniques. The HSiSs have an inner and an outer surface for DNA immobilization sites after they have been functionalized with 3-aminopropyltriethoxysilane. From field emission scanning electron microscopy images, the presence of pores was confirmed in the functionalized HSiSs. Furthermore, Brunauer-Emmett-Teller (BET) analysis indicated that the HSiSs have four times more surface area than silica spheres that have no pores. These aminated HSiSs were deposited onto a screen-printed carbon paste electrode containing a layer of gold nanoparticles (AuNPs) to form a AuNP/HSiS hybrid sensor membrane matrix. Aminated DNA probes were grafted onto the AuNP/HSiS-modified screen-printed electrode via imine covalent bonds with use of glutaraldehyde cross-linker. The DNA hybridization reaction was studied by differential pulse voltammetry using an anthraquinone redox intercalator as the electroactive DNA hybridization label. The DNA biosensor demonstrated a linear response over a wide target sequence concentration range of 1.0×10-12-1.0×10-2 μM, with a low detection limit of 8.17×10-14 μM (R2 = 0.99). The improved performance of the DNA biosensor appeared to be due to the hollow structure and rough surface morphology of the hollow silica particles, which greatly increased the total binding surface area for high DNA loading capacity. The HSiSs also facilitated molecule diffusion through the silica hollow structure, and substantially improved the overall DNA hybridization assay. Graphical abstract Step-by-step DNA biosensor fabrication based on aminated hollow silica spheres.
  4. Jaafar J, Watanabe Y, Ikegami T, Miyamoto K, Tanaka N
    Anal Bioanal Chem, 2008 Aug;391(7):2551-6.
    PMID: 18458888 DOI: 10.1007/s00216-008-2063-3
    An anion exchange monolithic silica capillary column was prepared by surface modification of a hybrid monolithic silica capillary column prepared from a mixture of tetramethoxysilane (TMOS) and methyltrimethoxysilane (MTMS). The surface modification was carried out by on-column copolymerization of N-[3-(dimethylamino)propyl]acrylamide methyl chloride-quaternary salt (DMAPAA-Q) with 3-methacryloxypropyl moieties bonded as an anchor to the silica surface to form a strong anion exchange stationary phase. The columns were examined for their performance in liquid chromatography (LC) and capillary electrochromatography (CEC) separations of common anions. The ions were separated using 50 mM phosphate buffer at pH 6.6. Evaluation by LC produced an average of 30,000 theoretical plates (33 cm column length) for the inorganic anions and nucleotides. Evaluation by CEC, using the same buffer, produced enhanced chromatographic performance of up to ca. 90,000 theoretical plates and a theoretical plate height of ca. 4 mum. Although reduced efficiency was observed for inorganic anions that were retained a long time, the results of this study highlight the potential utility of the DMAPAA-Q stationary phase for anion separations.
  5. Ballouze R, Ismail MN, Abu Kassim NS, Salhimi SM, Mohamad I, Abd Mutalib NS, et al.
    Anal Bioanal Chem, 2024 Jan;416(2):545-557.
    PMID: 38040942 DOI: 10.1007/s00216-023-05061-3
    Chronic rhinosinusitis with nasal polyps (CRSwNP) is a persistent inflammation of the sinonasal mucosa. CRSwNP treatments are associated with inconsistent efficacy and recurrence of symptoms. Dynorphin 1-17 (DYN 1-17) and its fragments have been shown to modulate the immune response in various inflammatory conditions. This study aimed to investigate the effect of different pH and degrees of inflammation on DYN 1-17 metabolism in human CRSwNP tissues. DYN 1-17 was incubated with grade 3 and grade 4 inflamed tissues of CRSwNP patients at pH 5.5 and pH 7.4 over a range of incubation periods. The resulting fragments were identified using an ultra-performance liquid chromatography (UPLC) system coupled to quadrupole-time of flight (QTOF) mass spectrometry based on their accurate mass. The rate of DYN 1-17 fragmentation was slower at pH 5.5 in comparison to pH 7.4. The extent and rate of metabolism of DYN 1-17 were much lower in grade 3 inflamed tissue (31-32 fragments) than in grade 4 (34-41 fragments). N-Terminal fragments (DYN 1-15, 1-11, 1-10, and 1-6) were metabolized slower at pH 5.5 as compared to pH 7.4. DYN 1-12, 1-8, 2-10, 4-10, 5-10, and 8-14 were only observed under the inflammatory pH while DYN 5-17 and 6-17 were only identified upon incubation with grade 4 CRSwNP tissues. DYN 1-17 metabolism was significantly affected by the pH level and the severity of the inflammation of CRSwNP tissues, indicating the potential roles of DYN 1-17 and its fragments in modulating the inflammatory response and their avenue as therapeutics in future studies.
  6. Azri FA, Selamat J, Sukor R, Yusof NA, Raston NHA, Eissa S, et al.
    Anal Bioanal Chem, 2021 Jun;413(15):3861-3872.
    PMID: 34021369 DOI: 10.1007/s00216-021-03336-1
    Aptamers are short single-stranded oligonucleotides (either DNA or RNA) that can fold into well-defined three-dimensional (3D) spatial structures which enable them to capture their specific target by complementary shape interactions. Aptamers are selected from large random libraries through the SELEX process and only a small fraction of the sequence is involved in direct docking with the target. In this paper, we describe the possible truncation variants of zearalenone (ZEA) aptamer which might be an effective binding region for the target. The originally selected zearalenone (ZEA) aptamer was 80-mer in length and shown to bind the target with a high affinity (Kd = 41 ± 5 nM). Herein, computational docking simulation was performed with 15 truncated variants to determine the predicted binding energy and responsible binding site of the aptamer-analyte complex. The results revealed that 5 truncated variants had binding energy lower than - 7.0 kcal/mol. Circular dichroism analysis was performed on the shortlisted aptamer and the conformational change of aptamers was observed with the presence of an analyte. Aptamer Z3IN (29-mer) was chosen as the most enhanced affinity for its target with a dissociation constant of 11.77 ± 1.44 nM. The aptamer was further applied in the electrochemical aptasensor of ZEA based on an indirect competitive format. The results demonstrated that the truncated aptamer leads to an enhancement of the sensitivity of the biosensor.
  7. Parthasarathy S, Ramanathan S, Ismail S, Adenan MI, Mansor SM, Murugaiyah V
    Anal Bioanal Chem, 2010 Jul;397(5):2023-30.
    PMID: 20454783 DOI: 10.1007/s00216-010-3707-7
    A new solid phase extraction method for rapid high performance liquid chromatography-UV determination of mitragynine in plasma has been developed. Optimal separation was achieved with an isocratic mobile phase consisting of acetonitrile-ammonium acetate buffer, 50 mM at pH 5.0 (50:50, v/v). The method had limits of detection and quantification of 0.025 and 0.050 microg/mL, respectively. The method was accurate and precise for the quantitative analysis of mitragynine in human and rat plasma with within-day and between-day accuracies between 84.0 and 109.6%, and their precision values were between 1.7 and 16.8%. Additional advantages over known methods are related to the solid phase extraction technique for sample preparation which yields a clean chromatogram, a short total analysis time, requires a smaller amount of plasma samples and has good assay sensitivity for bioanalytical application. The method was successfully applied in pharmacokinetic and stability studies of mitragynine. In the present study, mitragynine was found to be fairly stable during storage and sample preparation. The present study showed for the first time the detailed pharmacokinetic profiles of mitragynine. Following intravenous administration, mitragynine demonstrated a biphasic elimination from plasma. Oral absorption of the drug was slow, prolonged and was incomplete, with a calculated absolute oral bioavailability value of 3.03%. The variations observed in previous pharmacokinetic studies after oral administration of mitragynine could be attributed to its poor bioavailability rather than to the differences in assay method, metabolic saturation or mitragynine dose.
  8. Al-Qaim FF, Mussa ZH, Yuzir A
    Anal Bioanal Chem, 2018 Aug;410(20):4829-4846.
    PMID: 29806068 DOI: 10.1007/s00216-018-1120-9
    The scarcity of data about the occurrence of pharmaceuticals in water bodies in Malaysia prompted us to develop a suitable analytical method to address this issue. We therefore developed a method based on solid-phase extraction combined with liquid chromatography-time of flight/mass spectrometry (SPE-LC-TOF/MS) for the analysis of sixteen prescribed and two nonprescribed pharmaceuticals that are potentially present in water samples. The levels of these pharmaceuticals, which were among the top 50 pharmaceuticals consumed in Malaysia during the period 2011-2014, in influent and effluent of five sewage treatment plants (STPs) in Bangi, Malaysia, were then analyzed using the developed method. All of the pharmaceuticals were separated chromatographically using a 5 μm, 2.1 mm × 250 mm C18 column at a flow rate of 0.3 mL/min. Limits of quantification (LOQs) were 0.3-8.2 ng/L, 6.5-89 ng/L, and 11.1-93.8 ng/L in deionized water (DIW), STP effluent, and STP influent, respectively, for most of the pharmaceuticals. Recoveries were 51-108%, 52-118%, and 80-107% from the STP influent, STP effluent, and DIW, respectively, for most of the pharmaceuticals. The matrix effect was also evaluated. The signals from carbamazepine, diclofenac sodium, and mefenamic acid were found to be completely suppressed in the STP influent. The signals from other compounds were found to be influenced by matrix effects more strongly in STP influent (enhancement or suppression of signal ≤180%) than in effluent (≤94%). The signal from prednisolone was greatly enhanced in the STP influent, indicating a matrix effect of -134%. Twelve pharmaceuticals were frequently detected in all five STPs, and caffeine, prazosin, and theophylline presented the highest concentrations among all the pharmaceuticals monitored: up to 7611, 550, and 319 ng/L in the STP influent, respectively. To the best of our knowledge, this is the first time that prazosin has been detected in a water matrix in Malaysia. Graphical abstract ᅟ.
  9. Nekouei F, Kargarzadeh H, Nekouei S, Keshtpour F, Makhlouf AS
    Anal Bioanal Chem, 2017 Feb;409(4):1079-1092.
    PMID: 27815609 DOI: 10.1007/s00216-016-0026-7
    A new method was developed for the efficient spectrophotometric determination of methylene blue (MB) dye in solutions. The method is based on a combined dispersive solid phase and cloud point extraction using Cu(OH)2 nanoflakes (as an adsorbent). Cu(OH)2 nanoflakes were synthesized by facile and fast methods and characterized using various techniques. The developed method is based on the adsorption of MB on the Cu(OH)2 nanoflakes and transfer into a surfactant-rich phase using Triton X-114 as a nonionic surfactant. Subsequently, MB dye is desorbed from Cu(OH)2 nanoflakes using a mixture of nitric acid and methanol solution and determined by UV-Vis spectrophotometry. The effects of pH, amount of Cu(OH)2 nanoflakes, volume (concentration of Triton X-114), and temperature were investigated by designing experiments using response surface methodology (RSM). A quadratic model was utilized to predict the variables. Analysis of variance (ANOVA) was applied for the analysis of variables and their interactions, and optimal conditions were established. The results demonstrated logical agreement between experimental and predicted values of the response owing to high F value, low P value, and low lack-of-fit. The calibration graph was linear in the range of 2.0-350.0 μg L-1 of MB dye with a correlation coefficient (R) of 0.9996. The limits of detection and quantification were found to be 0.65 and 2.05 μg L-1, respectively. The developed method was successfully applied to different water samples, thereby confirming the applicability of the approach. Graphical Abstract Proposed procedure.
  10. Ngo DB, Chaibun T, Yin LS, Lertanantawong B, Surareungchai W
    Anal Bioanal Chem, 2021 Feb;413(4):1027-1037.
    PMID: 33236225 DOI: 10.1007/s00216-020-03061-1
    The aim of this study was to develop a highly specific electrochemical DNA sensor using functionalized lead sulphide (PbS) quantum dots for hepatitis E virus genotype 3 (HEV3) DNA target detection. Functionalized-PbS quantum dots (QDs) were used as an electrochemical label for the detection of HEV3-DNA target by the technique of square wave anodic stripping voltammetry (SWASV). The functionalized-PbS quantum dots were characterized by UV-vis, FTIR, XRD, TEM and zeta potential techniques. As-prepared, functionalized-PbS quantum dots have an average size of 4.15 ± 1.35 nm. The detection platform exhibited LOD and LOQ values of 1.23 fM and 2.11 fM, respectively. HEV3-DNA target spiked serum is also reported.Graphical abstract.
  11. Abdul Aziz SFN, Hui OS, Salleh AB, Normi YM, Yusof NA, Ashari SE, et al.
    Anal Bioanal Chem, 2024 Jan;416(1):227-241.
    PMID: 37938411 DOI: 10.1007/s00216-023-05011-z
    This study aims to investigate the influence of copper(II) ions as a cofactor on the electrochemical performance of a biocomposite consisting of a mini protein mimicking uricase (mp20) and zeolitic immidazolate framework-8 (ZIF-8) for the detection of uric acid. A central composite design (CCD) was utilized to optimize the independent investigation, including pH, deposition potential, and deposition time, while the current response resulting from the electrocatalytic oxidation of uric acid was used as the response. The statistical analysis of variance (ANOVA) showed a good correlation between the experimental and predicted data, with a residual standard error percentage (RSE%) of less than 2% for predicting optimal conditions. The synergistic effect of the nanoporous ZIF-8 host, Cu(II)-activated mp20, and reduced graphene oxide (rGO) layer resulted in a highly sensitive biosensor with a limit of detection (LOD) of 0.21 μM and a reproducibility of the response (RSD = 0.63%). The Cu(II)-activated mp20@ZIF-8/rGO/SPCE was highly selective in the presence of common interferents, and the fabricated layer exhibited remarkable stability with signal changes below 4.15% after 60 days. The biosensor's reliable performance was confirmed through real sample analyses of human serum and urine, with comparable recovery values to conventional HPLC.
  12. Lim GW, Lim JK, Ahmad AL, Chan DJ
    Anal Bioanal Chem, 2016 Mar;408(8):2083-93.
    PMID: 26842746 DOI: 10.1007/s00216-015-9298-6
    The direct correlation between disease and lysozyme (LYZ) levels in human body fluids makes the sensitive and convenient detection of LYZ the focus of scientific research. Fluorescent molecularly imprinted polymer has emerged as a new alternative for LYZ detection in order to resolve the limitation of immunoassays, which are expensive, unstable, require complex preparation, and are time consuming. In this study, a novel fluorescence molecularly imprinted polymer based on Navicula sp. frustules (FITC-MIP) has been synthesized via post-imprinting treatment for LYZ detection. Navicula sp. frustules were used as supported material because of their unique properties of moderate surface area, reproducibility, and biocompatibility, to address the drawbacks of nanoparticle core material with low adsorption capacity. The FITC acts as recognition signal and optical readout, whereas MIP provides LYZ selectivity. The synthesized FITC-MIP showed a response time as short as 5 min depending on the concentration of LYZ. It is found that the LYZ template can significantly quench the fluorescence intensity of FITC-MIP linearly within a concentration range of 0 to 0.025 mg mL(-1), which is well described by Stern-Volmer equation. The FITC-MIP can selectively and sensitively detect down to 0.0015 mg mL(-1) of LYZ concentration. The excellent sensing performance of FITC-MIP suggests that FITC-MIP is a potential biosensor in clinical diagnosis applications.
  13. Muniandy S, Dinshaw IJ, Teh SJ, Lai CW, Ibrahim F, Thong KL, et al.
    Anal Bioanal Chem, 2017 Nov;409(29):6893-6905.
    PMID: 29030671 DOI: 10.1007/s00216-017-0654-6
    Reduced graphene oxide (rGO) has emerged as a promising nanomaterial for reliable detection of pathogenic bacteria due to its exceptional properties such as ultrahigh electron transfer ability, large surface to volume ratio, biocompatibility, and its unique interactions with DNA bases of the aptamer. In this study, rGO-azophloxine (AP) nanocomposite aptasensor was developed for a sensitive, rapid, and robust detection of foodborne pathogens. Besides providing an excellent conductive and soluble rGO nanocomposite, the AP dye also acts as an electroactive indicator for redox reactions. The interaction of the label-free single-stranded deoxyribonucleic acid (ssDNA) aptamer with the test organism, Salmonella enterica serovar Typhimurium (S. Typhimurium), was monitored by differential pulse voltammetry analysis, and this aptasensor showed high sensitivity and selectivity for whole-cell bacteria detection. Under optimum conditions, this aptasensor exhibited a linear range of detection from 108 to 101 cfu mL-1 with good linearity (R 2 = 0.98) and a detection limit of 101 cfu mL-1. Furthermore, the developed aptasensor was evaluated with non-Salmonella bacteria and artificially spiked chicken food sample with S. Typhimurium. The results demonstrated that the rGO-AP aptasensor possesses high potential to be adapted for the effective and rapid detection of a specific foodborne pathogen by an electrochemical approach. Graphical abstract Fabrication of graphene-based nanocomposite aptasensor for detection of foodborne pathogen.
  14. Chua LS, Lee JY, Chan GF
    Anal Bioanal Chem, 2013 Apr;405(10):3063-74.
    PMID: 23292042 DOI: 10.1007/s00216-012-6630-2
    There are relatively limited studies on the protein of honey samples mainly because of the low amount of protein in honey (0.1-0.5 %), the difficulty in extracting honey protein from the sugar-rich environment, and the hindrance of protein characterization by conventional approaches. Several protein extraction methods such as mechanical (ultrafiltration and ultracentrifugation) and chemical (precipitation) techniques have been applied to different types of honey samples. Most of these studies reported the quantity and molecular size of honey protein from gel electrophoresis, but were unable to identify and characterize the protein. This limitation might be due to the low capacity of analytical equipment in those days. Although different precipitants have also been used, not all them are compatible with mass spectrometric methods during downstream analysis. As a result, the sample preparation step is essential in order to confidently characterize the low and varied amount of honey protein. Nowadays, honey protein is getting attention from researchers because of its potential activity in pharmacological applications. Therefore, honey protein extraction and determination by mass spectrometry are critically reviewed in order to stimulate further honey protein research.
  15. Syakila RN, Lim SM, Agatonovic-Kustrin S, Lim FT, Ramasamy K
    Anal Bioanal Chem, 2019 Feb;411(6):1181-1192.
    PMID: 30680424 DOI: 10.1007/s00216-018-1544-2
    The cholesterol-lowering properties of 12 lactic acid bacteria (LAB) in the absence or presence of 0.3% bile salts were assessed and compared quantitatively and qualitatively in vitro. A new, more sensitive and cost-effective high-performance thin-layer chromatography method combined with digital image evaluation of derivatised chromatographic plates was developed and validated to quantify cholesterol in LAB culture media. The performance of the method was compared with that of the o-phthalaldehyde method. For qualitative assessment, assimilated fluorescently tagged cholesterol was visualised by confocal microscopy. All LAB strains exhibited a cholesterol-lowering effect of various degrees (19-59% in the absence and 14-69% in the presence of bile salts). Lactobacillus plantarum LAB12 and Pentosaceus pentosaceus LAB6 were the two best strains of lactobacilli and pediococci. They lowered cholesterol levels by 59% and 54%, respectively, in the absence and by 69% and 58%, respectively, in the presence of bile salts. Confocal microscopy showed that cholesterol was localised at the outermost cell membranes of LAB12 and LAB6. The present findings warrant in-depth in vivo study. Graphical abstract (A) 3D plots based on scan at 525 nm of (B) derivatized HPTLC plate of separated cholesterol and (C) confocal microscopic image showing the localisation of NBD-cholesterol assimilated by LAB.
  16. Mahmoudian MR, Basirun WJ, Woi PM, Yousefi R, Alias Y
    Anal Bioanal Chem, 2019 Jan;411(2):517-526.
    PMID: 30498983 DOI: 10.1007/s00216-018-1476-x
    We report a green synthesis of oatmeal ZnO/silver composites in the presence of L-glutamine as an electrochemical sensor for Pb2+ detection. The synthesis was performed via the direct reduction of Ag+ in the presence of L-glutamine in NaOH. X-ray diffraction indicated that the Ag+ was completely reduced to metallic Ag. The field emission scanning electron microscopy (FESEM) and energy dispersive X-ray results confirmed an oatmeal-like morphology of the ZnO with the presence of Ag. The FESEM images showed the effect of L-glutamine on the ZnO morphology. The EIS results confirmed a significant decrease in the charge transfer resistance of the modified glassy carbon electrode due to the presence of Ag. From the differential pulse voltammetry results, a linear working range for the concentration of Pb2+ between 5 and 6 nM with LOD of 0.078 nM (S/N = 3) was obtained. The sensitivity of the linear segment is 1.42 μA nM-1 cm-2. The presence of L-glutamine as the capping agent and stabilizer decreases the size of Ag nanoparticles and prevents the agglomeration of ZnO, respectively. Graphical abstract ᅟ.
  17. Philipp AA, Wissenbach DK, Weber AA, Zapp J, Maurer HH
    Anal Bioanal Chem, 2011 Mar;399(8):2747-53.
    PMID: 21249338 DOI: 10.1007/s00216-011-4660-9
    Mitragyna speciosa (Kratom) is currently used as a drug of abuse. When monitoring its abuse in urine, several alkaloids and their metabolites must be considered. In former studies, mitragynine (MG), its diastereomer speciogynine (SG), and paynantheine and their metabolites could be identified in rat and human urine using LC-MS(n). In Kratom users' urines, besides MG and SG, further isomeric compounds were detected. To elucidate whether the MG and SG diastereomer speciociliatine (SC) and its metabolites represent further compounds, the phase I and II metabolites of SC were identified first in rat urine after the administration of the pure alkaloid. Then, the identified rat metabolites were screened for in the urine of Kratom users using the above-mentioned LC-MS(n) procedure. Considering the mass spectra and retention times, it could be confirmed that SC and its metabolites are so far the unidentified isomers in human urine. In conclusion, SC and its metabolites can be used as further markers for Kratom use, especially by consumption of raw material or products that contain a high amount of fruits of the Malaysian plant M. speciosa.
  18. Safian MF, Zinn N, Seidler J, Lehmann WD
    Anal Bioanal Chem, 2016 Nov;408(27):7663-7667.
    PMID: 27515797
    A new method for microquantification of phospholipid classes by nanoelectrospray mass spectrometry and stable isotope dilution is presented. The method covers the sum of phosphatidylcholine and sphingomyelin and in addition selectively quantifies phosphatidylethanolamine, phosphatidylserine, and phosphatidylinositol. A phospholipid class is quantified together with its corresponding lyso-species due to the presence of a common head group. Phospholipids are extracted from tissue lysates, hydrolysed by hydrofluoric acid, and the liberated polar head groups choline, ethanolamine, serine, and inositol are quantified by nanoelectrospray mass spectrometry using deuterium-labeled analogs of the head groups as internal standards. The method is applied to tissue samples of a gastrointestinal tumor and of corresponding non-affected control tissue. In the tumor sample, the abovementioned phospholipids were found at roughly threefold elevated concentrations with a virtually unaltered relative abundance profile.
  19. Ang QY, Low SC
    Anal Bioanal Chem, 2015 Sep;407(22):6747-58.
    PMID: 26163132 DOI: 10.1007/s00216-015-8841-9
    Molecular imprinting is an emerging technique to create imprinted polymers that can be applied in affinity-based separation, in particular, biomimetic sensors. In this study, the matrix of siloxane bonds prepared from the polycondensation of hydrolyzed tetraethoxysilane (TEOS) was employed as the inorganic monomer for the formation of a creatinine (Cre)-based molecularly imprinted polymer (MIP). Doped aluminium ion (Al(3+)) was used as the functional cross-linker that generated Lewis acid sites in the confined silica matrix to interact with Cre via sharing of lone pair electrons. Surface morphologies and pore characteristics of the synthesized MIP were determined by field emission scanning electron microscopy (FESEM) and Brunauer-Emmet-Teller (BET) analyses, respectively. The imprinting efficiency of MIPs was then evaluated through the adsorption of Cre with regard to molar ratios of Al(3+). A Cre adsorption capacity of up to 17.40 mg Cre g(-1) MIP was obtained and adsorption selectivity of Cre to its analogues creatine (Cr) and N-hydroxysuccinimide (N-hyd) were found to be 3.90 ± 0.61 and 4.17 ± 3.09, respectively. Of all the studied MIP systems, chemisorption was predicted as the rate-limiting step in the binding of Cre. The pseudo-second-order chemical reaction kinetic provides the best correlation of the experimental data. Furthermore, the equilibrium adsorption capacity of MIP fit well with a Freundlich isotherm (R (2) = 0.98) in which the heterogeneous surface was defined.
  20. Agyei D, Acquah C, Tan KX, Hii HK, Rajendran SRCK, Udenigwe CC, et al.
    Anal Bioanal Chem, 2018 Jan;410(2):297-306.
    PMID: 28884330 DOI: 10.1007/s00216-017-0599-9
    Food-derived bioactive proteins and peptides have gained acceptance among researchers, food manufacturers and consumers as health-enhancing functional food components that also serve as natural alternatives for disease prevention and/or management. Bioactivity in food proteins and peptides is determined by their conformations and binding characteristics, which in turn depend on their primary and secondary structures. To maintain their bioactivities, the molecular integrity of bioactive peptides must remain intact, and this warrants the study of peptide form and structure, ideally with robust, highly specific and sensitive techniques. Short single-stranded nucleic acids (i.e. aptamers) are known to have high affinity for cognate targets such as proteins and peptides. Aptamers can be produced cost-effectively and chemically derivatized to increase their stability and shelf life. Their improved binding characteristics and minimal modification of the target molecular signature suggests their suitability for real-time detection of conformational changes in both proteins and peptides. This review discusses the developmental progress of systematic evolution of ligands by exponential enrichment (SELEX), an iterative technology for generating cost-effective aptamers with low dissociation constants (Kd) for monitoring the form and structure of bioactive proteins and peptides. The review also presents case studies of this technique in monitoring the structural stability of bioactive peptide formulations to encourage applications in functional foods. The challenges and potential of aptamers in this research field are also discussed. Graphical abstract Advancing bioactive proteins and peptide functionality via aptameric ligands.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links