  1. Yap KL
    Malays J Pathol, 1994 Jun;16(1):49-56.
    PMID: 16329576
    The aim of this study was to optimize the conditions for the passive adsorption of polyclonal antibody onto plain surface polystyrene latex particles and its performance in a slide latex agglutination test for rotavirus antigen detection. Cleaning of latex particles by washing through repetitive centrifuging, decanting and resuspending in distilled water was adequate in removing surfactants from the particles' surfaces to enable coating. A study of antibody concentration, incubation temperature and buffer pH revealed that optimum coating was achieved with a 3-fold excess of antibody to the calculated total particle surface capacity for the antibody in a glycine-saline buffer of pH 9.2 at 40 degrees C for 4 hours. The ionic strength and pH of the latex suspending buffer and the sample buffer were critical factors determining the sensitivity of the test and the appearance of non-specific agglutination. Ultrasonication, addition of glycerol and Tween 20, either individually or in combination, were able to suppress non-specific agglutination in some batches of latex reagents. Polyethylene glycol 6000 enhanced the quality of agglutination as well as reduced the time of its appearance, especially in reagents that produced poor agglutination.
    Matched MeSH terms: Latex Fixation Tests/methods*
  2. Mahat M, Abdullah WZ, Hussin CM
    J Immunol Res, 2014;2014:850810.
    PMID: 25759835 DOI: 10.1155/2014/850810
    Measurement of von Willebrand factor antigen (VWF : Ag) levels is usually performed in a specialised laboratory which limits its application in routine clinical practice. So far, no commercial rapid test kit is available for VWF : Ag estimation. This paper discusses the technical aspect of latex agglutination method which was established to suit the purpose of estimating von Willebrand factor (VWF) levels in the plasma sample. The latex agglutination test can be performed qualitatively and semiquantitatively. Reproducibility, stability, linearity, limit of detection, interference, and method comparison studies were conducted to evaluate the performance of this test. Semiquantitative latex agglutination test was strongly correlated with the reference immunoturbidimetric assay (Spearman's rho = 0.946, P < 0.001, n = 132). A substantial agreement (κ = 0.77) was found between qualitative latex agglutination test and the reference assay. Using the scoring system for the rapid latex test, no agglutination is with 0% VWF : Ag (control negative), 1+ reaction is equivalent to <20% VWF : Ag, and 4+ reaction indicates >150% VWF : Ag (when comparing with immunoturbidimetric assay). The findings from evaluation studies suggest that latex agglutination method is suitable to be used as a rapid test kit for the estimation of VWF : Ag levels in various clinical conditions associated with high levels and low levels of VWF : Ag.
    Matched MeSH terms: Latex Fixation Tests/methods*
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links