This study aimed to determine the role of surfactant protein A (SP-A) in the formation of stable microbubble in tracheal aspirates. Our results showed that as the concentration of anti SP-A antibodies added to tracheal aspirate specimens increased, the number of stable microbubble formed in the specimen decreased. The correlation between stable microbubble counts and the SP-A levels in the tracheal aspirates was good, r = 0.85, p < 0.05. This study suggests that SP-A plays an important role in stable microbubble formation. Measurement of small stable microbubbles is thus a useful bedside test for predicting the SP-A activity in the tracheal aspirates and in indirect measurement of lung maturity.
An in-house enzyme-linked immunoabsorbant assay (ELISA) for SP-A was successfully developed using in-house polyclonal anti SP-A and a commercial polyclonal anti-rabbit immunoglobulin horseradish peroxidase conjugate system. The standard curve, generated by using 50 ng of SP-A to coat the plate and 1:500 dilution of polyclonal anti SP-A as a primary antibody, was linear for concentrations of SP-A ranging from 4 micrograms/l to 4000 micrograms/l and reproducible. Results of recovery study of SP-A from a known sample of tracheal aspirate ranged from 94%-114%. Intra- and inter-assay coefficients of variations were 2.7% and 5.6% respectively for a known sample of tracheal aspirate. Interference study showed that tracheal aspirate did not interfere with the assay. The assay developed was intended to be used for SP-A measurement in tracheal aspirates obtained from neonates with and without respiratory distress syndrome.