Displaying publications 21 - 24 of 24 in total

Abstract:
Sort:
  1. Centeno A, Xie F, Alford N
    IET Nanobiotechnol, 2013 Jun;7(2):50-8.
    PMID: 24046905
    Metal-induced fluorescence enhancement (MIFE) is a promising strategy for increasing the sensitivity of fluorophores used in biological sensors. This study uses the finite-difference time-domain technique to predict the fluorescent enhancement rate of a fluorophore molecule in close proximity to a gold or silver spherical nanoparticle. By considering commercially available fluorescent dyes the computed results are compared with the published experimental data. The results show that MIFE is a complex coupling process between the fluorophore molecule and the metal nanoparticle. Nevertheless using computational electromagnetic techniques to perform calculations it is possible to calculate, with reasonable accuracy, the fluorescent enhancement. Using this methodology it will be possible to consider different shaped metal nanoparticles and any supporting substrate material in the future, an important step in building reliable biosensors capable of detecting low levels of proteins tagged with fluorescence molecules.
  2. Hussein AS, Abdullah N, Ahmadun FR
    IET Nanobiotechnol, 2013 Jun;7(2):33-41.
    PMID: 24046903
    Linamarin-loaded poly (lactide-co-glycolide) (PLGA) nanoparticles (NPs) were prepared by the double emulsion solvent evaporation technique. The formulated PLGA (50:50) and PLGA (85:15) NPs were spherically shaped, having an average particle size < 190 nm, drug entrapment efficiency (50-52%) and zeta potentials ranging from -25 to -30 mV. Interestingly, all formulated PLGA NPs exhibited a controlled biphasic release profile. Polymer degradation was investigated in the current research to determine the major degradation products and then the polymer biocompatibility as well as safety. The PLGA NPs degradation behaviour was investigated by measuring water uptake, mass loss, change of pH of the degradation medium, morphological changes, and lactic and glycolic acid concentrations. Gravimetrical methods, pH meter, scanning electron microscope and high-performance liquid chromatography were employed, respectively. PLGA (50:50) NPs were found to degrade faster than PLGA (85:15) NPs. With regard to water uptake, mass loss and pH change, the degradation behaviour of PLGA (50:50) NPs was significantly (rho < 0.05) different from that of PLGA (85:15) NPs. A complete degradation of PLGA (50:50) NPs was achieved after 102 days, whereas, only about 60% of PLGA (85:15) NPs were degraded within the same period. Complete degradation and release of the degradation products naturally by the body ensures safety of the delivery carrier.
  3. Makhadmeh GN, Abdul Aziz A, Abdul Razak K, Abu Noqta O
    IET Nanobiotechnol, 2015 Dec;9(6):381-5.
    PMID: 26647815 DOI: 10.1049/iet-nbt.2015.0003
    This study analysed the physical effects of Cichorium Pumilum (CP), as a natural photosensitizer (PS), and Protoporphyrin IX (PpIX), as a synthetic PS, encapsulated with silica nanoparticles (SiNPs) in photodynamic therapy. The optimum concentrations of CP and PpIX, needed to destroy Red Blood Cells (RBC), were determined and the efficacy of encapsulated CP and PpIX were compared with naked CP and PpIX was verified. The results confirmed the applicability of CP and PpIX encapsulated in SiNPs on RBCs, and established a relationship between the encapsulated CP and PpIX concentration and the time required to rupture 50% of the RBCs (t50). The CP and PpIX encapsulated in SiNPs exhibited higher efficacy compared with that of naked CP and PpIX, respectively, and CP had less efficacy compared with PpIX.
  4. Ghanim MH, Najimudin N, Ibrahim K, Abdullah MZ
    IET Nanobiotechnol, 2014 Jun;8(2):77-82.
    PMID: 25014078 DOI: 10.1049/iet-nbt.2012.0044
    Miniaturisation of microchip capillary electrophoresis (MCE) is becoming an increasingly important research topic, particularly in areas related to micro total analysis systems or lab on a chip. One of the important features associated with the miniaturised MCE system is the portable power supply unit. In this work, a very low electric field MCE utilising an amperometric detection scheme was designed for use in DNA separation. The device was fabricated from a glass/polydimethylsiloxane hybrid engraved microchannel with platinum electrodes sputtered onto a glass substrate. Measurement was based on a three-electrode arrangement, and separation was achieved using a very low electric field of 12 V/cm and sample volume of 1.5 µl. The device was tested using two commercial DNA markers of different base pair sizes. The results are in agreement with conventional electrophoresis, but with improved resolution. The sensitivity consistently higher than 100 nA, and the separation time approximately 45 min, making this microchip an ideal tool for DNA analysis.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links